Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.871
Filter
1.
Kyobu Geka ; 77(5): 394-398, 2024 May.
Article in Japanese | MEDLINE | ID: mdl-38720610

ABSTRACT

A 73-year-old woman presented with left anterior chest pain and back pain. Computed tomography (CT) scan showed an anterior mediastinal tumor. It also showed partial anomalous pulmonary venous drainage (left superior pulmonary vein draining into the left brachiocephalic vein), and the tumor was located near the left brachiocephalic vein. The operation was performed through a median sternotomy to resect the thymus and tumor with partial resection of the left upper lobe due to the tumor's adhesion to the left upper lobe. One of the vascular anomalies encountered in adult thoracic surgery is partial anomalous pulmonary venous drainage. It is important to recognize the presence of such an anomaly on imaging and to anticipate the surgical procedure with a preoperative surgical technique.


Subject(s)
Pulmonary Veins , Thymoma , Thymus Neoplasms , Tomography, X-Ray Computed , Humans , Female , Aged , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Thymoma/surgery , Thymoma/diagnostic imaging , Thymoma/complications , Thymus Neoplasms/surgery , Thymus Neoplasms/diagnostic imaging , Thymus Neoplasms/complications
2.
Curr Probl Cardiol ; 49(7): 102613, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38692446

ABSTRACT

Catheter ablation has become an accepted first line therapy for paroxysmal atrial fibrillation (PAF), with pulmonary vein isolation (PVI) being the key element of ablation strategies. Catheter ablation of AF has been proven to be superior to antiarrhythmic drug (AAD) therapy regarding efficacy and improvement of survival in patients with heart failure. PVI has become a routine treatment procedure in recent decades especially for patients with symptomatic PAF. Recent research investigations have shown that AF recurrence still occurs in a significant number of patients after ablation. AF recurrence leads to a decrease in patients' quality of life and is related to an increased risk of cardiovascular events and mortality. As most arrhythmia recurrences take place within the first 3 months after the initial procedure, this time period is seen as a so-called "blanking period", in which ablation is not recommended, since up to 50 % of patients can become arrhythmia free in the long run. Ablation therapy, however, is less successful in patients suffering from long standing persistent AF, with a 20.3 % success rate after a single procedure and a 45 % success rate after multiple RFA procedures. Several scores have been established and validated to predict cardiac rhythm outcomes after catheter ablation. However, due to the lack of external validation of most of the scores, their efficacy in predicting recurrence of atrial fibrillation needs to be further evaluated in independent external studies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnosis , Humans , Catheter Ablation/methods , Anti-Arrhythmia Agents/therapeutic use , Recurrence , Pulmonary Veins/surgery , Treatment Outcome , Patient Care Team/organization & administration , Quality of Life
3.
J Am Coll Cardiol ; 83(20): 2015-2027, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749620

ABSTRACT

The identification of the pulmonary veins as a trigger source for atrial fibrillation (AF) has established pulmonary vein isolation (PVI) as a key target for AF ablation. However, PVI alone does not prevent recurrent AF in many patients, and numerous additional ablation strategies have failed to improve on PVI outcomes. This therapeutic limitation may be due, in part, to a failure to identify and intervene specifically on the pro-fibrillatory substrate within the atria and pulmonary veins. In this review paper, we highlight several emerging approaches with clinical potential that target atrial cardiomyopathy-the underlying anatomic, electrical, and/or autonomic disease affecting the atrium-in various stages of practice and investigation. In particular, we consider the evolving roles of risk factor modification, targeting of epicardial adipose tissue, tissue fibrosis, oxidative stress, and the inflammasome, along with aggressive early anti-AF therapy in AF management. Attention to combatting substrate development promises to improve outcomes in AF.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Humans , Catheter Ablation/methods , Pulmonary Veins/surgery
4.
Med Sci Monit ; 30: e943526, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734884

ABSTRACT

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Workflow , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Male , Middle Aged , Treatment Outcome , Pulmonary Veins/surgery , Aged , Propensity Score , Recurrence
5.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38701222

ABSTRACT

AIMS: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS: The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION: The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Feasibility Studies , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Catheter Ablation/methods , Catheter Ablation/instrumentation , Aged , Equipment Design , Phrenic Nerve/injuries , Time Factors
6.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
7.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709062

ABSTRACT

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Atrial Fibrillation/surgery , Esophagus/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/instrumentation , Pulmonary Veins/surgery
8.
Medicine (Baltimore) ; 103(21): e38285, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788033

ABSTRACT

Total anomalous pulmonary venous connection (TAPVC) is a rare congenital defect where pulmonary venous plexus fails to connect with the left atrium (LA). Surgical repair is the primary treatment for TAPVC, but factors influencing outcomes are not fully understood. This study investigates the early outcomes of surgical repair for TAPVC and associated factors. A retrospective cohort analysis was conducted on TAPVC patients who underwent surgical repair between 2012 and 2022. Data were collected from medical records and supplemented with phone call validation. Demographic characteristics, surgical data, diagnostic tests, and outcomes were analyzed. Statistical analysis included chi-square, t-tests, and multivariate logistic regression using SPSS. A total of 88 patients underwent surgical repair for TAPVC, resulting in a mortality rate of 21.6%. Weight and bypass time were significantly associated with patient survival. Female patients had a higher likelihood of death. The anatomic type did not significantly influence mortality. Patients with pulmonary venous obstruction (PVO) experienced a higher mortality rate. Notably, ligation of the vertical vein in supracardiac and infracardiac types was associated with lower mortality. In conclusion, our study identifies several key factors contributing to higher mortality rates following TAPVC surgery, including low weight, female gender, prolonged bypass time, and preoperative vein obstruction. Highlighting the significance of surgical technique, particularly the sutureless approach, we advocate for its meticulous consideration to achieve improved outcomes. Furthermore, our findings indicate a potential decrease in mortality associated with vertical vein ligation, which may mitigate the risk of post-repair heart failure. We suggest further rigorous studies to gain comprehensive insights into TAPVC surgical interventions.


Subject(s)
Scimitar Syndrome , Humans , Female , Male , Retrospective Studies , Scimitar Syndrome/surgery , Scimitar Syndrome/mortality , Infant , Postoperative Complications/mortality , Postoperative Complications/epidemiology , Infant, Newborn , Risk Factors , Pulmonary Veins/surgery , Pulmonary Veins/abnormalities , Sex Factors
9.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793000

ABSTRACT

Pulsed Field Ablation (PFA) is the latest and most intriguing technology for catheter ablation of atrial fibrillation, due to its capability to generate irreversible and cardiomyocytes-selective electroporation of cell membranes by delivering microsecond-lasting high-voltage electrical fields, leading to high expectations. The first trials to assess the clinical success of PFA, reported an arrhythmia-free survival at 1-year of 78.5%, while other trials showed less enthusiastic results: 66.2% in paroxysmal and 55.1% in persistent AF. Nevertheless, real world data are encouraging. The isolation of pulmonary veins with PFA is easily achieved with 100% acute success. Systematic invasive remapping showed a high prevalence of durable pulmonary vein isolation at 75 and 90 days (range 84-96%), which were significatively lower in redo procedures (64.3%). The advent of PFA is prompting a reconsideration of the role of the autonomic nervous system in AF ablation, as PFA-related sparing of the ganglionated plexi could lead to the still undetermined effect on late arrhythmias' recurrences. Moreover, a new concept of a blanking period could be formulated with PFA, according to its different mechanism of myocardial injury, with less inflammation and less chronic fibrosis. Finally, in this review, we also compare PFA with thermal energy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Recurrence , Atrial Fibrillation/surgery , Humans , Catheter Ablation/methods , Catheter Ablation/statistics & numerical data , Incidence , Pulmonary Veins/surgery
10.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Article in English | MEDLINE | ID: mdl-38655693

ABSTRACT

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/adverse effects , Prospective Studies , Aged , Time Factors , Heart Rate , Action Potentials , Electrocardiography, Ambulatory/instrumentation , Recurrence , Cardiac Catheters , Predictive Value of Tests , Treatment Outcome , Imaging, Three-Dimensional , Risk Factors , Equipment Design , Electrophysiologic Techniques, Cardiac
12.
JACC Clin Electrophysiol ; 10(4): 685-694, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38658060

ABSTRACT

BACKGROUND: Reconnection after mitral isthmus (MI) block with radiofrequency ablation is common. OBJECTIVES: The aim of this study was to investigate the effects of ethanol infusion in the vein of Marshall (EIVOM) on acute reconnection after MI bidirectional block. METHODS: Patients with persistent atrial fibrillation who were scheduled to receive radiofrequency ablation for the first time were randomly assigned to the radiofrequency catheter ablation (RFCA) group (n = 44) or the EIVOM group (n = 45). The RFCA group's strategy was bilateral pulmonary vein ablation and linear ablation; in the EIVOM group, EIVOM was performed first. The primary endpoint was acute reconnection 30 minutes after MI bidirectional block. RESULTS: A total of 89 patients (average age 62.9 years; 57.3% male) were enrolled. The average duration for persistent atrial fibrillation was 2.3 years. Before observation, all patients in the EIVOM group achieved MI bidirectional block (45 of 45 [100%]), compared with 84.1% (37 of 44) in the RFCA group. After the observation, 3 cases of MI reconnection occurred in the EIVOM group and 13 cases in the RFCA group (6.7% vs 35.1%; P < 0.05). After additional ablation, the final MI block rates in the EIVOM and RFCA groups were 97.8% (44 of 45) and 72.7% (32 of 44), respectively. During a 1-year follow-up, 8 of 45 patients who underwent EIVOM had recurrent atrial fibrillation, compared with 14 of 44 in the RFCA group (17.8% vs 31.8%; P < 0.01). CONCLUSIONS: EIVOM can reduce acute reconnection after MI bidirectional block and significantly increase first-pass MI block.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Mitral Valve , Pulmonary Veins , Humans , Male , Female , Middle Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Aged , Mitral Valve/surgery , Pulmonary Veins/surgery , Ethanol/administration & dosage , Recurrence , Treatment Outcome
13.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Article in English | MEDLINE | ID: mdl-38682420

ABSTRACT

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Echocardiography, Transesophageal , Pulmonary Veins , Thrombosis , Humans , Echocardiography, Transesophageal/methods , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/methods , Retrospective Studies , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Prevalence , Middle Aged , Aged , Anticoagulants/therapeutic use , Heart Diseases/diagnostic imaging , Heart Diseases/epidemiology
14.
World J Pediatr Congenit Heart Surg ; 15(3): 319-324, 2024 May.
Article in English | MEDLINE | ID: mdl-38654425

ABSTRACT

Background: We aim to determine the surgical outcomes of adult patients with total anomalous pulmonary venous connection (TAPVC) and examine the regression of pulmonary artery (PA) pressures after the procedure. Methods: We reviewed the hospital records from 2003 to 2022 and identified 49 adult patients with TAPVC. We assessed their surgical outcomes and the trend of PA pressures after the procedure. Continuous data are presented as mean ± SD or median (interquartile range) and categorical variables are presented as percentages. Results: The median age of the patients was 23 years (range 18-42) and 31 (63.3%) were male. Thirty-six patients (73.5%) had supracardiac TAPVC. The mean systolic PA pressure was 65.8 ± 16.4 mm Hg and it decreased by 47.9% (34%, 61.8%) after surgery. Moderate or more tricuspid regurgitation was seen in 27 (55.1%) patients before surgery; however, it was present in only 3 (6.1%) patients during early follow-up. There was no intraoperative or 30-day mortality, and the median hospital length of stay was six days. Long-term follow-up data were available for 29 patients with the average duration of follow-up being 5.6 years (range 6 months to 15 years) and the mean systolic PA pressures of this cohort was 29.8±7.9 mm Hg. Forty-six (93.1%) patients were asymptomatic; four women had uneventful pregnancies and delivered healthy children. Conclusion: Surgical repair of the naturally selected group of adult TAPVC patients can be performed safely with good results. Regression in flow-related pulmonary hypertension and an improvement in functional quality of life are seen in nearly all patients.


Subject(s)
Scimitar Syndrome , Humans , Female , Male , Adult , Adolescent , Scimitar Syndrome/surgery , Young Adult , Retrospective Studies , Pulmonary Artery/surgery , Pulmonary Artery/abnormalities , Treatment Outcome , Follow-Up Studies , Cardiac Surgical Procedures/methods , Pulmonary Veins/surgery , Pulmonary Veins/abnormalities
15.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646926

ABSTRACT

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Catheter Ablation/methods , Treatment Outcome , Pulmonary Veins/surgery , Female , Male , Recurrence , Europe , Middle Aged
16.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646922

ABSTRACT

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Vagus Nerve Injuries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Male , Female , Esophagus/injuries , Esophagus/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Middle Aged , Vagus Nerve Injuries/etiology , Vagus Nerve Injuries/epidemiology , Incidence , Aged , Machine Learning , Risk Factors , Germany/epidemiology , Burns/epidemiology , Burns/etiology , Time Factors , Treatment Outcome , Pulmonary Veins/surgery , Vagus Nerve
17.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584395

ABSTRACT

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Treatment Outcome , Prospective Studies , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Magnetic Phenomena , Recurrence
18.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38682165

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Machine Learning , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Prospective Studies , Aged , Electrophysiologic Techniques, Cardiac/methods , Treatment Outcome , Reproducibility of Results , Predictive Value of Tests , Action Potentials , Heart Rate , Algorithms , Signal Processing, Computer-Assisted
19.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584468

ABSTRACT

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Subject(s)
Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Catheter Ablation/instrumentation , Male , Female , Middle Aged , Aged , Treatment Outcome , Equipment Design , Electrophysiologic Techniques, Cardiac , Time Factors , Heart Rate , Action Potentials
20.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38624037

ABSTRACT

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Subject(s)
Atrial Fibrillation , Body Mass Index , Cryosurgery , Obesity , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Male , Female , Middle Aged , Republic of Korea/epidemiology , Aged , Treatment Outcome , Risk Factors , Pulmonary Veins/surgery , Obesity/complications , Thinness/complications , Time Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology
SELECTION OF CITATIONS