Vestn Oftalmol ; 135(5. Vyp. 2): 199-203, 2019.
Article in Russian | MEDLINE | ID: mdl-31691660

ABSTRACT

At present, installation of punctal plugs (tear duct occluders) draws attention of ophthalmologists, but this method of treating dry eye syndrome (DES) is not without complications. Considering the rise of DES occurrence - the tendency anticipated to continue - as well as expansion of indications for installation of tear duct occluders, their usage can be expected to rise. The article describes a relatively rare clinical case that involved intracanalicular migration of silicone punctal plug. A female patient of 36 years old sought medical help in Research Institute of Eye Diseases (Moscow) to treat a lump in the area of lower lacrimal punctum in the left eye that was growing in size; the lump had appeared around 2 months prior to the visit. Patient's medical history read that around 2 years ago she had a silicone occluder installed in the lower lacrimal punctum of the left eye. On examination, in the area of lower lacrimal punctum, a body with a nutrient vascular pedicle deriving from lower lacrimal duct could be found. The occluder was absent in the opening of the lacrimal punctum. A revision of lower tear duct cavity was performed to remove its contents. The body filling tear duct opening was removed with forceps. Substance was then sent for histological examination. Tear duct was scraped out, the silicone occluder removed and sent to laboratory for scanning electron microscopy. The patient had no complaints 6 months after the procedure. CONCLUSION: The study showed that the forming body was granuloma resulting from aseptic inflammation. Surface of the silicone occluder in retention of lacrimal pathways remained unchanged. Described surgical tactic is suitable for treating patients with intracanalicular punctal plug migration.


Subject(s)
Granuloma , Lacrimal Apparatus , Punctal Plugs , Adult , Dry Eye Syndromes , Female , Granuloma/etiology , Humans , Prosthesis Implantation , Punctal Plugs/adverse effects , Silicone Elastomers
3.
Arq. bras. oftalmol ; 82(5): 394-399, Sept.-Oct. 2019. graf
Article in English | LILACS | ID: biblio-1019429

ABSTRACT

ABSTRACT Purpose: Punctal stenosis can result in symptoms such as epiphora and can significantly reduce the quality of life of patients. Perforated punctal plug insertion is an easy procedure that is commonly used as the first step of treatment for punctal stenosis. Methods: Clinical, demographic, and outcome data were retrospectively collected for 54 eyes of 21 males and 11 females who consecutively presented to our Oculoplastic Clinic and underwent silicone Micro Flow perforated punctal plug insertion. All patients had epiphora with punctal stenosis. Results: Of the 54 plugs, 26 plugs (48.1%) were lost and 28 (51.8%) stayed in place. Of the latter, eight were explanted because of the occlusion of the plug with secretions and recurrent conjunctivitis; moreover, two plugs migrated deep into the vertical canaliculus. Of the 54 plugs, only 18 (33.3%) were well-tolerated with significant symptomatic improvement. Conclusion: Plug loss is a prominent problem in patients implanted with perforated punctal plugs. Silicone punctal plugs failed in 66.7% of our patients over a mean follow-up of 14.2 months.


RESUMO Objetivo: A estenose punctal pode resultar em sintomas como a epífora e diminuir significativamente a qua­lidade de vida dos pacientes. A inserção de um tampão perfurado é um procedimento fácil que é comumente usado como o primeiro passo do tratamento para a estenose punctal. Métodos: Dados clínicos, demográficos e de resultado foram coletados retrospectivamente de 54 olhos de 21 homens e 11 mulheres que consecutivamente se apresentaram em nossa Clínica de Oculoplástica e foram submetidos a inserção de um tampão de silicone perfurado Micro Flow. Todos os pacientes tinham epífora com estenose punctal. Resultados: Dos 54 tampões, 26 (48,1%) foram perdidos e 28 (51,8%) permaneceram no local. Destes últimos, 8 foram removidos devido a oclusão do tampão com secreção e conjuntivite recorrente, além disso, 2 migraram profundamente no canalículo vertical. Dos 54 tampões, apenas 18 (33,3%) foram bem tolerados com significativa melhora dos sintomas. Conclusão: A perda de tampões é um problema de destaque em pacientes implantados com tampões perfurados. Tampões de silicone falharam em 66,7% dos pacientes durante um seguimento médio de 14,2 meses.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Silicones/administration & dosage , Dry Eye Syndromes/surgery , Punctal Plugs/adverse effects , Lacrimal Apparatus/surgery , Lacrimal Duct Obstruction/therapy , Prostheses and Implants , Tears , Dry Eye Syndromes/complications , Prosthesis Implantation , Lacrimal Duct Obstruction/etiology
4.
Arq Bras Oftalmol ; 82(5): 394-399, 2019 06 27.
Article in English | MEDLINE | ID: mdl-31271571

ABSTRACT

PURPOSE: Punctal stenosis can result in symptoms such as epiphora and can significantly reduce the quality of life of patients. Perforated punctal plug insertion is an easy procedure that is commonly used as the first step of treatment for punctal stenosis. METHODS: Clinical, demographic, and outcome data were retrospectively collected for 54 eyes of 21 males and 11 females who consecutively presented to our Oculoplastic Clinic and underwent silicone Micro Flow perforated punctal plug insertion. All patients had epiphora with punctal stenosis. RESULTS: Of the 54 plugs, 26 plugs (48.1%) were lost and 28 (51.8%) stayed in place. Of the latter, eight were explanted because of the occlusion of the plug with secretions and recurrent conjunctivitis; moreover, two plugs migrated deep into the vertical canaliculus. Of the 54 plugs, only 18 (33.3%) were well-tolerated with significant symptomatic improvement. CONCLUSION: Plug loss is a prominent problem in patients implanted with perforated punctal plugs. Silicone punctal plugs failed in 66.7% of our patients over a mean follow-up of 14.2 months.


Subject(s)
Dry Eye Syndromes/surgery , Lacrimal Apparatus/surgery , Lacrimal Duct Obstruction/therapy , Punctal Plugs , Silicones/administration & dosage , Adolescent , Adult , Aged , Aged, 80 and over , Dry Eye Syndromes/complications , Female , Humans , Lacrimal Duct Obstruction/etiology , Male , Middle Aged , Prostheses and Implants , Prosthesis Implantation , Punctal Plugs/adverse effects , Tears , Young Adult
5.
J Fr Ophtalmol ; 42(4): 404-414, 2019 Apr.
Article in French | MEDLINE | ID: mdl-30879835

ABSTRACT

Lacrimal occlusion with punctal or canalicular plugs have been used to treat dry eye disease for more than 40 years. Indeed, punctal plugs constitute a safe and effective tool to retain the natural tear film and prolong the effect of tear substitutes. A wide variety of plugs is available, differing in their design, location (punctal versus canalicular) and their resorbability. There indications have increasingly broadened, and they are now one of the treatment options for numerous ocular surface diseases. Current research focuses on using punctal plugs for extended delivery of drugs to the ocular surface. This review addresses physiology of lacrimal drainage, available models of punctal plugs, their indications, practical details of prescribing and placing punctal and canalicular plugs, and possible complications.


Subject(s)
Punctal Plugs , Dry Eye Syndromes/complications , Dry Eye Syndromes/epidemiology , Dry Eye Syndromes/surgery , Humans , Keratoconjunctivitis/complications , Keratoconjunctivitis/epidemiology , Keratoconjunctivitis/surgery , Lacrimal Apparatus/physiopathology , Lacrimal Apparatus/surgery , Prosthesis Implantation , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Punctal Plugs/adverse effects , Punctal Plugs/classification , Punctal Plugs/standards , Silicone Elastomers , Tears
6.
J Fr Ophtalmol ; 42(3): e95-e104, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30692031

ABSTRACT

Lacrimal occlusion with punctal or canalicular plugs have been used to treat dry eye disease for more than 40 years. Indeed, punctal plugs constitute a safe and effective tool to retain the natural tear film and prolong the effect of tear substitutes. A wide variety of plugs is available, differing in their design, location (punctal versus canalicular) and their resorbability. There indications have increasingly broadened, and they are now one of the treatment options for numerous ocular surface diseases. Current research focuses on using punctal plugs for extended delivery of drugs to the ocular surface. This review addresses physiology of lacrimal drainage, available models of punctal plugs, their indications, practical details of prescribing and placing punctal and canalicular plugs, and possible complications.


Subject(s)
Dry Eye Syndromes/therapy , Lacrimal Apparatus , Punctal Plugs , Therapeutic Occlusion , Humans , Lacrimal Apparatus/surgery , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Punctal Plugs/adverse effects , Silicone Elastomers/adverse effects , Therapeutic Occlusion/adverse effects , Therapeutic Occlusion/instrumentation , Therapeutic Occlusion/methods , Treatment Outcome
7.
Cornea ; 37 Suppl 1: S58-S61, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30211751

ABSTRACT

Punctal plugs are an effective treatment option for patients with aqueous-deficient dry eye refractory to topical medications. However, punctal plugs are not commonly used in clinical practice mainly because of various misconceptions, rather than clinical complications. We analyzed previous studies and present 5 misconceptions related to punctal plugs. The first and most important misconception is that ocular surface inflammation should be sufficiently controlled before punctal plug insertion. However, it is unclear how ocular surface inflammation can be sufficiently controlled in patients refractory to conventional topical medications. The second misconception is that silicone punctal plugs are made of nonabsorbable materials and, therefore, permanent. In fact, silicone plugs are reversible and can be easily removed if necessary. Therefore, depending on the specific type, nonabsorbable plugs may be classified as reversible or permanent. The third misconception is that punctal plugs disrupt normal tear drainage. However, punctal plugs maintain natural tears on the ocular surface for extended periods and reduce the frequency of artificial tear use. The fourth is that all punctal and canalicular plugs have similar effects. The efficacy and complication rates differ depending on plug types. The fifth misconception about punctal plugs is that they are effective only in aqueous-deficient dry eye disease. Many studies have reported that plugs are effective in a variety of ocular diseases and conditions. Understanding these 5 misconceptions may provide an opportunity to rethink the use of silicone punctal plugs in clinical practice.


Subject(s)
Dry Eye Syndromes/surgery , Lacrimal Apparatus/surgery , Ophthalmologic Surgical Procedures/methods , Punctal Plugs , Device Removal , Humans , Punctal Plugs/adverse effects , Silicone Elastomers , Tears/metabolism