Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.956
Filter
1.
Zhonghua Nei Ke Za Zhi ; 63(6): 550-559, 2024 Jun 01.
Article in Chinese | MEDLINE | ID: mdl-38825924

ABSTRACT

Thyroid nodule and cervical lymph node biopsy is the main clinical method for evaluating the condition and determining the follow-up treatment plan. The literature on thyroid nodule puncture predominantly focuses on thyroid fine needle puncture, and there are limited systematic articles on coarse needle aspiration for thyroid-related diseases and needle biopsy of thyroid-related cervical lymph node diseases. However, this shortage of articles does not reflect the diagnostic value of coarse needle aspiration in thyroid biopsy and cervical lymph node-related diseases. Currently, different departments of many hospitals in China are conducting or planning to perform needle biopsy of thyroid and cervical lymph node-related diseases to improve the standardization and safety of related operations. Standardization is needed for the indications, contraindications, perioperative period, postoperative complications management, puncture specimen processing, and related genetic analysis of thyroid and cervical lymph node puncture. For this purpose, Interventional Ultrasound Committee of Chinese College of Interventionalists organized a panel of domestic experts in the field of thyroid diseases to discuss and formulate a consensus. Based on the latest research progress, combined with the clinical realities in China, this Expert Consensus on Ultrasound Guided Thyroid and Neck Lymph Node Puncture (2023 edition) is released.


Subject(s)
Lymph Nodes , Neck , Thyroid Gland , Humans , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Thyroid Gland/diagnostic imaging , Thyroid Gland/pathology , China , Biopsy, Fine-Needle/methods , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Consensus , Ultrasonography, Interventional/methods , Punctures/methods
2.
J Craniofac Surg ; 35(4): 1201-1204, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38829146

ABSTRACT

OBJECTIVE: This study aimed to investigate the feasibility, safety, and efficacy of the neuroendoscopy-assisted entire-process visualization technique (NEAEVT) of ventricular puncture for external ventricular drainage. METHODS: Eighty-eight patients with cerebral hemorrhage who underwent unilateral ventricular puncture for external ventricular drainage in our hospital from June 2021 to June 2023 were analyzed. Patients were grouped according to puncture technique: NEAEVT (30 patients), freehand (30 patients), and laser-navigation-assisted (28 patients). Operation time, drainage tube placement, and catheter-related hemorrhage incidence were compared between the groups. RESULTS: Mean operation time significantly differed between the freehand, NEAEVT, and laser-assisted groups (17.07, 18.37, and 34.04 min, respectively; P <0.0001). The position of the drainage tube was optimal or adequate in all patients of the NEAEVT group; optimal/adequate positioning was achieved in 80% of the freehand group. No catheter-related hemorrhage occurred in the NEAEVT group. Three freehand group patients and 2 laser-assisted group patients experienced catheter-related hemorrhage. CONCLUSION: The NEAEVT of ventricular puncture is accurate and achieves ventricular drainage without significantly increasing surgical trauma, operation time, or incidence of hemorrhage.


Subject(s)
Cerebral Ventricles , Drainage , Neuroendoscopy , Operative Time , Punctures , Humans , Male , Female , Drainage/methods , Middle Aged , Neuroendoscopy/methods , Aged , Cerebral Ventricles/surgery , Cerebral Ventricles/diagnostic imaging , Adult , Cerebral Hemorrhage/surgery , Feasibility Studies , Ventriculostomy/methods , Retrospective Studies , Treatment Outcome
3.
Ann Card Anaesth ; 27(1): 58-60, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722123

ABSTRACT

ABSTRACT: The transversus thoracic muscle plane (TTP) block is gaining widespread recognition in cardiac surgery, particularly in facilitating fast-tracking. Here, we report a case of inadvertent puncture of the right ventricle (RV) during the administration of ultra sound-guided (USG) TTP block in a 3-year-old child posted for atrial septal defect (ASD) closure and mitral valve repair. We also discuss the care that should be taken to avoid such complications and such cases require extra caution during TTP block.


Subject(s)
Heart Ventricles , Humans , Heart Ventricles/diagnostic imaging , Child, Preschool , Heart Septal Defects, Atrial/surgery , Male , Ultrasonography, Interventional/methods , Nerve Block/methods , Nerve Block/adverse effects , Punctures/adverse effects
4.
Urolithiasis ; 52(1): 75, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38753168

ABSTRACT

This study was designed to evaluate the non-inferiority of ultrasound puncture followed by endoscopically guided tract dilatation compared to the standard fluoroscopy-guided PCNL. Forty patients with non-opaque kidney stones eligible for PCNL were randomly divided into two groups. The standard fluoroscopy-guided PCNL using the Amplatz dilator was performed in the XRAY group. In the SONO group, the Kidney was punctured under an ultrasound guide followed by tract dilatation using a combination of the Amplatz dilator based on the tract length and an endoscopically guided tract dilatation using a bi-prong forceps in cases of short-advancement. The primary outcome was successful access. In 90% of cases in the XRAY and 95% in the SONO group access dilatation process was performed uneventfully at the first attempt (p = 0.5). In 45% of cases in the SONO group, bi-prong forceps were used as salvage for short-advancement. In one case in the X-ray group over-advancement occurred. One month after surgery, the stone-free rate on the CT-scan was 75% for the X-ray group and 85% for the SONO group (p = 0.4). There were no significant differences in operation time, hospitalization duration, transfusion, or complication rates between the two groups. We conclude that ultrasound-guided renal puncture, followed by endoscopically guided tract dilatation can achieve a high success rate similar to X-ray-guided PCNL while avoiding the harmful effects of radiation exposure and the risk of over-advancement.


Subject(s)
Dilatation , Kidney Calculi , Nephrolithotomy, Percutaneous , Punctures , Ultrasonography, Interventional , Humans , Fluoroscopy/methods , Kidney Calculi/surgery , Kidney Calculi/diagnostic imaging , Nephrolithotomy, Percutaneous/methods , Nephrolithotomy, Percutaneous/adverse effects , Nephrolithotomy, Percutaneous/instrumentation , Male , Female , Middle Aged , Punctures/methods , Dilatation/methods , Dilatation/instrumentation , Adult , Kidney/surgery , Kidney/diagnostic imaging , Treatment Outcome , Aged
5.
Vestn Otorinolaringol ; 89(2): 15-20, 2024.
Article in Russian | MEDLINE | ID: mdl-38805458

ABSTRACT

OBJECTIVE: Optimization of the method of puncture treatment of acute bacterial maxillary sinusitis (ABMS) through the development of original devices for drainage of the maxillary sinus (MS). MATERIAL AND METHODS: Registration and comparative analysis of the results of puncture methods of treatment of 120 patients with ABMS using developed new original devices for drainage of MS with one channels and with two channels in comparison with the Kulikovsky's needle (KN) was carried out. Based on the results of the analysis, the effectiveness of the original devices was assessed. During the clinical study, patients were divided into two groups: in group I, patients underwent of the MS puncture using KN, in group II, using original devices. Groups I and II, depending on the absence or presence of a block of the natural anastomosis MS, was divided into subgroups A and B, respectively. After puncture of the MS, the pain syndrome was assessed by patients using Visual Analogue Scale (VAS) and by doctors - using Touch Visual Pain (TVP) scale. RESULTS: Our study showed that when puncturing the upper jaw with an original needle with one channels and with two channels, compared with the use of KN, there is a decrease in pain (the average VAS score was 1.5±0.3 and 1.7±0.3 points, respectively; the average TVP scale score was 0.9±0.2 and 1.8±0.3 points, respectively, the difference is significant, p≤0.05). Patients of subgroup IB were manipulated with two KN, patients of subgroup IIB manipulated using the original device with two channels without an additional needle (the average VAS score was 3.0±0.4 and 1.3±0.3 points, respectively; the average TVP scale score was 2.7±0.4 and 1.0±0.2 points, respectively, the difference is significant, p≤0.05). The doctors also assessed the devices used for puncture of the upper jaw. As a result of the study, the high efficiency and safety of using new original devices was established.


Subject(s)
Maxillary Sinusitis , Punctures , Humans , Maxillary Sinusitis/microbiology , Maxillary Sinusitis/therapy , Maxillary Sinusitis/diagnosis , Female , Male , Adult , Punctures/methods , Punctures/instrumentation , Middle Aged , Treatment Outcome , Drainage/methods , Drainage/instrumentation , Pain Measurement/methods , Maxillary Sinus/microbiology , Maxillary Sinus/surgery , Acute Disease , Bacterial Infections/therapy , Bacterial Infections/diagnosis
6.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38697398

ABSTRACT

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Subject(s)
Axillary Vein , Defibrillators, Implantable , Punctures , Humans , Defibrillators, Implantable/adverse effects , Male , Female , Retrospective Studies , Aged , Middle Aged , Axillary Vein/diagnostic imaging , Prosthesis Implantation/methods , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Treatment Outcome , Time Factors
7.
BMJ Case Rep ; 17(5)2024 May 13.
Article in English | MEDLINE | ID: mdl-38740444

ABSTRACT

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Subject(s)
Laryngeal Neoplasms , Laryngectomy , Punctures , Trachea , Humans , Male , Laryngectomy/methods , Laryngectomy/adverse effects , Laryngeal Neoplasms/surgery , Punctures/methods , Trachea/surgery , Esophagus/surgery , Surgical Staplers , Aged , Middle Aged , Larynx/surgery , Surgical Stapling/methods , Larynx, Artificial
8.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Treatment Outcome , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis
10.
Biomed Environ Sci ; 37(2): 170-177, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38582979

ABSTRACT

Objective: To evaluate the diagnostic value of histopathological examination of ultrasound-guided puncture biopsy samples in extrapulmonary tuberculosis (EPTB). Methods: This study was conducted at the Shanghai Public Health Clinical Center. A total of 115 patients underwent ultrasound-guided puncture biopsy, followed by MGIT 960 culture (culture), smear, GeneXpert MTB/RIF (Xpert), and histopathological examination. These assays were performed to evaluate their effectiveness in diagnosing EPTB in comparison to two different diagnostic criteria: liquid culture and composite reference standard (CRS). Results: When CRS was used as the reference standard, the sensitivity and specificity of culture, smear, Xpert, and histopathological examination were (44.83%, 89.29%), (51.72%, 89.29%), (70.11%, 96.43%), and (85.06%, 82.14%), respectively. Based on liquid culture tests, the sensitivity and specificity of smear, Xpert, and pathological examination were (66.67%, 72.60%), (83.33%, 63.01%), and (92.86%, 45.21%), respectively. Histopathological examination showed the highest sensitivity but lowest specificity. Further, we found that the combination of Xpert and histopathological examination showed a sensitivity of 90.80% and a specificity of 89.29%. Conclusion: Ultrasound-guided puncture sampling is safe and effective for the diagnosis of EPTB. Compared with culture, smear, and Xpert, histopathological examination showed higher sensitivity but lower specificity. The combination of histopathology with Xpert showed the best performance characteristics.


Subject(s)
Mycobacterium tuberculosis , Tuberculosis, Extrapulmonary , Humans , China , Sensitivity and Specificity , Punctures , Ultrasonography, Interventional , Biopsy, Needle
11.
Medicine (Baltimore) ; 103(15): e37623, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38608084

ABSTRACT

OBJECTIVE: To emphasize preventive measures and outline management strategies for inadvertent ureteral cannulation. METHODS: We present a case report and conduct a literature review of 39 case reports on ureteral cannulation, examining a total of 48 patients. RESULTS: About 67% of the cases were female, and long-term catheterization was observed in 67% of the cases. Neurological conditions such as spinal cord injury (SCI), stroke, dementia, multiple sclerosis, and myasthenia gravis were the primary factors (48%) in ureteral cannulation. Symptoms included flank pain (46%), fever (31%), oliguria (27%), non-deflatable balloon issues (25%), hematuria (21%), abdominal pain (17%), urine leak (12.5%), and nausea/vomiting (8%). Complications varied, including acute pyelonephritis (35%), acute kidney injury (27%), urosepsis (21%), and ureter rupture (17%). Despite inadvertent catheter placement, 25% of patients had no complications. More than half of the patients (58%) were managed through catheter change, while 27% underwent cysto-ureteroscopy with or without balloon puncture or ureteral stenting. Additionally, 10% received interventional radiology procedures, 6.25% underwent surgical repair, and 4% underwent ultrasound-guided balloon puncture. CONCLUSIONS: Female gender, neurologic conditions, and long-term catheterization were identified as predominant risk factors. Early detection of ureteral cannulation can prevent severe complications, particularly in certain special populations such as patients with neurogenic bladder or SCI, who may have reduced sensation and expression capabilities.


Subject(s)
Ureter , Humans , Female , Male , Urinary Catheters/adverse effects , Punctures , Ureteroscopy , Hematuria
12.
BMC Musculoskelet Disord ; 25(1): 294, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627655

ABSTRACT

PURPOSE: To assess the clinical safety, accuracy, and efficacy of percutaneous kyphoplasty (PKP) surgery using an enhanced method of unilateral puncture on the convex side for the treatment of painful osteoporotic vertebral compression fractures (P-OVCF) with scoliosis. METHODS: Clinical and radiographic data of P-OVCF patients with scoliosis who underwent PKP via unilateral puncture on the convex side from January 2018 to December 2021 were retrospectively analyzed. This technique's detailed surgical steps and tips were described. The local kyphosis angle (LKA), scoliosis Cobb angle (SCA), and local scoliosis Cobb angle (LSCA) were measured using X-ray and compared at pre-operation, post-operation, and the last follow-up. The width of pedicle (POW), inner inclination angle (IIA), lateral distance (LD), and puncture course length (PCL) were measured on the axial computed tomography image and compared between two sides. Postoperative computed tomography was employed to evaluate the condition of cement distribution and puncture. Clinical outcomes were evaluated using the Oswestry Disability Index (ODI) and Visual Analog Scale (VAS) for back pain (BP). RESULTS: Thirty-six patients, 23 women and 13 men, with an average age of 76.31 ± 6.28 years were monitored for 17.69 ± 4.70 months. The median surgical duration of single vertebrae was 35 min. The volume of bone cement for single vertebrae was 3.81 ± 0.87 ml and the proportion of sufficient cement distribution of the patients was 97.22. LKA was considerably improved from pre-operation to post-operation and sustained at the last follow-up. SCA and LSCA were not significantly modified between these three-time points. IIA, PCL, and LD were lower on the convex side than on the concave side. POW was considerably wider on the convex side. The ODI and VAS-BP scores were significantly improved after surgery and sustained during the follow-up. CONCLUSIONS: Combining with the proper assessment of the pre-injured life status of patients, PKP surgery using unilateral puncture on the convex side for the treatment of P-OVCF with scoliosis can achieve safe, excellent clinical, and radiographic outcomes.


Subject(s)
Fractures, Compression , Kyphoplasty , Kyphosis , Osteoporotic Fractures , Scoliosis , Spinal Fractures , Male , Humans , Female , Aged , Aged, 80 and over , Kyphoplasty/methods , Fractures, Compression/diagnostic imaging , Fractures, Compression/etiology , Fractures, Compression/surgery , Scoliosis/complications , Scoliosis/diagnostic imaging , Retrospective Studies , Spinal Fractures/complications , Spinal Fractures/diagnostic imaging , Spinal Fractures/surgery , Treatment Outcome , Spine , Bone Cements/therapeutic use , Punctures , Kyphosis/diagnostic imaging , Kyphosis/etiology , Kyphosis/surgery , Osteoporotic Fractures/complications , Osteoporotic Fractures/diagnostic imaging , Osteoporotic Fractures/surgery
16.
Catheter Cardiovasc Interv ; 103(6): 982-994, 2024 May.
Article in English | MEDLINE | ID: mdl-38584518

ABSTRACT

Endovascular aortic repair is an emerging novel intervention for the management of abdominal aortic aneurysms. It is crucial to compare the effectiveness of different access sites, such as transfemoral access (TFA) and upper extremity access (UEA). An electronic literature search was conducted using PubMed, EMBASE, and Google Scholar databases. The primary endpoint was the incidence of stroke/transient ischemic attack (TIA), while the secondary endpoints included technical success, access-site complications, mortality, myocardial infarction (MI), spinal cord ischemia, among others. Forest plots were constructed for the pooled analysis of data using the random-effects model in Review Manager, version 5.4. Statistical significance was set at p < 0.05. Our findings in 9403 study participants (6228 in the TFA group and 3175 in the UEA group) indicate that TFA is associated with a lower risk of stroke/TIA [RR: 0.55; 95% CI: 0.40-0.75; p = 0.0002], MI [RR: 0.51; 95% CI: 0.38-0.69; p < 0.0001], spinal cord ischemia [RR: 0.41; 95% CI: 0.32-0.53, p < 0.00001], and shortens fluoroscopy time [SMD: -0.62; 95% CI: -1.00 to -0.24; p = 0.001]. Moreover, TFA required less contrast agent [SMD: -0.33; 95% CI: -0.61 to -0.06; p = 0.02], contributing to its appeal. However, no significant differences emerged in technical success [p = 0.23], 30-day mortality [p = 0.48], ICU stay duration [p = 0.09], or overall hospital stay length [p = 0.22]. Patients with TFA had a lower risk of stroke, MI, and spinal cord ischemia, shorter fluoroscopy time, and lower use of contrast agents. Future large-scale randomized controlled trials are warranted to confirm and strengthen these findings.


Subject(s)
Blood Vessel Prosthesis Implantation , Catheterization, Peripheral , Endovascular Aneurysm Repair , Femoral Artery , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/methods , Catheterization, Peripheral/methods , Endovascular Aneurysm Repair/methods , Femoral Artery/diagnostic imaging , Pilot Projects , Punctures , Risk Assessment , Risk Factors , Stroke/etiology , Stroke/mortality , Stroke/prevention & control , Time Factors , Treatment Outcome , Upper Extremity/blood supply
18.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658126

ABSTRACT

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
19.
Front Immunol ; 15: 1366955, 2024.
Article in English | MEDLINE | ID: mdl-38562928

ABSTRACT

Background: Individual T cell responses vary significantly based on the microenvironment present at the time of immune response and on prior induced T cell memory. While the cecal ligation and puncture (CLP) model is the most commonly used murine sepsis model, the contribution of diverse T cell responses has not been explored. We defined T cell subset responses to CLP using single-cell RNA sequencing and examined the effects of prior induced T cell memory (Immune Education) on these responses. We hypothesized that Immune Education prior to CLP would alter T cell responses at the single cell level at a single, early post-CLP time point. Methods: Splenic T cells were isolated from C57BL/6 mice. Four cohorts were studied: Control, Immune-Educated, CLP, and Immune-Educated CLP. At age 8 weeks, Immune-Educated and Immune-Educated CLP mice received anti-CD3ϵ antibody; Control and CLP mice were administered an isotype control. CLP (two punctures with a 22-gauge needle) was performed at 12-13 weeks of life. Mice were sacrificed at baseline or 24-hours post-CLP. Unsupervised clustering of the transcriptome library identified six distinct T cell subsets: quiescent naïve CD4+, primed naïve CD4+, memory CD4+, naïve CD8+, activated CD8+, and CD8+ cytotoxic T cell subsets. T cell subset specific gene set enrichment analysis and Hurdle analysis for differentially expressed genes (DEGs) were performed. Results: T cell responses to CLP were not uniform - subsets of activated and suppressed T cells were identified. Immune Education augmented specific T cell subsets and led to genomic signatures favoring T cell survival in unoperated and CLP mice. Additionally, the combination of Immune Education and CLP effected the expression of genes related to T cell activity in ways that differed from CLP alone. Validating our finding that IL7R pathway markers were upregulated in Immune-Educated CLP mice, we found that Immune Education increased T cell surface IL7R expression in post-CLP mice. Conclusion: Immune Education enhanced the expression of genes associated with T cell survival in unoperated and CLP mice. Induction of memory T cell compartments via Immune Education combined with CLP may increase the model's concordance to human sepsis.


Subject(s)
Punctures , Sepsis , Mice , Humans , Animals , Infant , Cell Survival , Mice, Inbred C57BL , Sequence Analysis, RNA
20.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38587311

ABSTRACT

AIMS: Pericardiocentesis is usually completed under fluoroscopy. The electroanatomic mapping (EAM) system allows visualizing puncture needle tip (NT) while displaying the electrogram recorded from NT, making it possible to obtain epicardial access (EA) independent of fluoroscopy. This study was designed to establish and validate a technique by which EA is obtained under guidance of three-dimensional (3D) EAM combined with NT electrogram. METHODS AND RESULTS: 3D shell of the heart was generated, and the NT was made trackable in the EAM system. Unipolar NT electrogram was continuously monitored. Penetration into pericardial sac was determined by an increase in NT potential amplitude and an injury current. A long guidewire of which the tip was also visible in the EAM system was advanced to confirm EA. Epicardial access was successfully obtained without complication in 13 pigs and 22 patients. In the animals, NT potential amplitude was 3.2 ± 1.0 mV when it was located in mediastinum, 5.2 ± 1.6 mV when in contact with fibrous pericardium, and 9.8 ± 2.8 mV after penetrating into pericardial sac (all P ≤ 0.001). In human subjects, it measured 1.54 ± 0.40 mV, 3.61 ± 1.08 mV, and 7.15 ± 2.88 mV, respectively (all P < 0.001). Fluoroscopy time decreased in every 4-5 cases (64 ± 15, 23 ± 17, and 0 s for animals 1-4, 5-8, 9-13, respectively, P = 0.01; 44 ± 23, 31 ± 18, 4±7 s for patients 1-7, 8-14, 15-22, respectively, P < 0.001). In five pigs and seven patients, EA was obtained without X-ray exposure. CONCLUSION: By tracking NT in the 3D EAM system and continuously monitoring the NT electrogram, it is feasible and safe to obtain EA with minimum or no fluoroscopic guidance.


Subject(s)
Electrophysiologic Techniques, Cardiac , Epicardial Mapping , Imaging, Three-Dimensional , Needles , Pericardium , Humans , Male , Female , Animals , Pericardium/diagnostic imaging , Pericardium/surgery , Middle Aged , Imaging, Three-Dimensional/methods , Aged , Electrophysiologic Techniques, Cardiac/instrumentation , Electrophysiologic Techniques, Cardiac/methods , Epicardial Mapping/methods , Pericardiocentesis/methods , Punctures , Predictive Value of Tests , Adult , Swine , Models, Animal , Action Potentials , Sus scrofa , Fluoroscopy
SELECTION OF CITATIONS
SEARCH DETAIL
...