Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 17.553
Filter
1.
PLoS One ; 19(5): e0302000, 2024.
Article in English | MEDLINE | ID: mdl-38709720

ABSTRACT

Wastewater surveillance represents an alternative approach to regulating contamination and the early detection of infectious agents and outbreaks of diseases of public health importance. This study evaluated domestic wastewater effects on recreational waters in estuarine and seawater bodies in Guayas and Santa Elena provinces in Ecuador, South America. Fecal indicator bacteria (thermotolerant coliforms) served as key indicators for evaluation. Physical, chemical, and microbiological quality markers following the Ecuadorian environmental quality standard and the discharge of effluents to the water resource were analyzed. Samples were collected from 44 coastal sites and 2 oxidation lagoons during the dry and rainy seasons of 2020 and 2021, respectively. SARS-CoV-2 RNA was detected in samples with higher E. coli concentrations using reverse transcription quantitative PCR to detect the genes N and ORF1ab. All samples analyzed for SARS-CoV-2 showed Ct ˂ 40 for at least one gene. Four samples showed at least 20 genome copies of gene N per reaction. These were at an artisanal fishing port, an estuarine area (Palmar), a recreational bay, and an oxidation lagoon. A moderate correlation was found between SARS-CoV-2 RNA, thermotolerant coliform and E. coli (p-value ≤ 0.0037), and a strong and positive correlation between thermotolerant coliform and E. coli. (p-value ≤ 0.00001), highlighting the utility of these established parameters as a proxy of the virus. Significant differences were found in the concentrations of thermotolerant coliforms between seasons (p-value = 0.016) and sites (p-value = 0.005). The highest levels of coliforms were found in the dry season (63000 MPN/100 mL) in Anconcito and during the rainy season (14000 MPN/100 mL) at Esterillo in Playas County. It is recommended that the decentralized autonomous governments of the surveyed provinces in Ecuador implement urgent corrective actions and establish medium-term mechanisms to minimize a potential contamination route. Additional parameters must be included in the monitoring, such as Enterococcus and intestinal parasites, due to their public health implications. In the oxidation lagoons, maintenance actions must be carried out, including the dissolution of sediments, an increase in water retention times, and in situ treatment of the sludge, to improve the system's performance.


Subject(s)
COVID-19 , RNA, Viral , SARS-CoV-2 , Sewage , Water Quality , Ecuador , Sewage/virology , Sewage/microbiology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , RNA, Viral/genetics , RNA, Viral/isolation & purification , RNA, Viral/analysis , COVID-19/epidemiology , COVID-19/virology , Humans , Enterobacteriaceae/isolation & purification , Enterobacteriaceae/genetics , Water Microbiology , Environmental Monitoring/methods , Seawater/virology , Seawater/microbiology , Escherichia coli/genetics , Escherichia coli/isolation & purification , Wastewater/virology , Wastewater/microbiology
2.
Mikrochim Acta ; 191(6): 333, 2024 05 16.
Article in English | MEDLINE | ID: mdl-38753167

ABSTRACT

The COVID-19 pandemic has underscored the urgent need for rapid and reliable strategies for early detection of SARS-CoV-2. In this study, we propose a DNA nanosphere-based crosslinking catalytic hairpin assembly (CCHA) system for the rapid and sensitive SARS-CoV-2 RNA detection. The CCHA system employs two DNA nanospheres functionalized with catalytic hairpin assembly (CHA) hairpins. The presence of target SARS-CoV-2 RNA initiated the crosslinking of DNA nanospheres via CHA process, leading to the amplification of fluorescence signals. As a result, the speed of SARS-CoV-2 diagnosis was enhanced by significantly increasing the local concentration of the reagents in a crosslinked DNA product, leading to a detection limit of 363 fM within 5 min. The robustness of this system has been validated in complex environments, such as fetal bovine serum and saliva. Hence, the proposed CCHA system offers an efficient and simple approach for rapid detection of SARS-CoV-2 RNA, holding substantial promise for enhancing COVID-19 diagnosis.


Subject(s)
COVID-19 , Limit of Detection , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Humans , COVID-19/diagnosis , COVID-19/virology , Nanospheres/chemistry , DNA/chemistry , Inverted Repeat Sequences , Animals , COVID-19 Nucleic Acid Testing/methods , Cattle , Cross-Linking Reagents/chemistry , Saliva/virology
3.
Methods Mol Biol ; 2804: 195-206, 2024.
Article in English | MEDLINE | ID: mdl-38753149

ABSTRACT

Clinical diagnostics of infectious diseases via nucleic acid amplification tests (NAATs) depend on a separate step of isolation of nucleic acids from cells/viruses embedded in complex biological matrices. The most recent example has been reverse transcription polymerase chain reaction (RT-PCR) for amplification and detection of SARS-CoV-2 RNA for COVID-19 diagnostics. Kits for RNA extraction and purification are commercially available; however, their integration with amplification systems is generally lacking, resulting in two separate steps, i.e., sample preparation and amplification. This makes NAATs more time-consuming, requiring skilled personnel, and can increase the likelihood of contamination. Here, we describe a setup and methodology to perform the quick extraction and detection of nucleic acids in an integrated manner. In particular, we focus on the use of an immiscible filtration device for capture, isolation, concentration, amplification, and colorimetric detection of SARS-CoV-2 RNA.


Subject(s)
COVID-19 , Filtration , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , RNA, Viral/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/instrumentation , COVID-19/diagnosis , COVID-19/virology , Filtration/instrumentation , Filtration/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Colorimetry/methods , Colorimetry/instrumentation
4.
Clin Lab ; 70(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38747914

ABSTRACT

BACKGROUND: Nucleic acid amplification testing is the gold standard for SARS-CoV-2 diagnostics, although it may produce a certain number of false positive results. There has not been much published about the characteristics of false positive results. In this study, based on retesting, specimens that initially tested positive for SARS-CoV-2 were classified as true or false positive groups to characterize the distribution of cycle threshold (CT) values for N1 and N2 targets and number of targets detected for each group. METHODS: Specimens that were positive for N-gene on retesting and accompanied with S-gene were identified as true positives (true positive based on retesting, rTP), while specimens that retested negative were classified as false positives (false positive based on retesting, rFP). RESULTS: Of the specimens retested, 85/127 (66.9%) were rFP, 16/47 (34.0%) specimens with both N1 and N2 targets initially detected were rFP, and the CT values for each target was higher in rFP than in rTP. ROC curve analysis showed that optimal cutoff values of CT to differentiate between rTP and rFP were 34.8 for N1 and 33.0 for N2. With the optimal cutoff values of CT for each target, out of the 24 specimens that were positive for both N1 and N2 targets and classified as rTP, 23 (95.8%) were correctly identified as true positives. rFP specimens had a single N1 target in 52/61 (85.2%) and a single N2 target in 17/19 (89.5%). Notably, no true positive results were obtained from any specimens with only N2 target detected. CONCLUSIONS: These results suggest that retesting should be performed for positive results with a CT value greater than optimal cutoff value for each target or with a single N1 target amplified, considering the possibility of a false positive. This may provide guidance on indications to perform retesting to minimize the number of false positives.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , SARS-CoV-2 , Humans , False Positive Reactions , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/virology , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/standards , ROC Curve , Spike Glycoprotein, Coronavirus/genetics , Sensitivity and Specificity , Coronavirus Nucleocapsid Proteins/genetics , RNA, Viral/genetics , RNA, Viral/analysis
5.
Biosensors (Basel) ; 14(5)2024 May 13.
Article in English | MEDLINE | ID: mdl-38785719

ABSTRACT

Since SARS-CoV-2 is a highly transmissible virus, alternative reliable, fast, and cost-effective methods are still needed to prevent virus spread that can be applied in the laboratory and for point-of-care testing. Reverse transcription real-time fluorescence quantitative PCR (RT-qPCR) is currently the gold criteria for detecting RNA viruses, which requires reverse transcriptase to reverse transcribe viral RNA into cDNA, and fluorescence quantitative PCR detection was subsequently performed. The frequently used reverse transcriptase is thermolabile; the detection process is composed of two steps: the reverse transcription reaction at a relatively low temperature, and the qPCR performed at a relatively high temperature, moreover, the RNA to be detected needs to pretreated if they had advanced structure. Here, we develop a fast and sensitive one-tube SARS-CoV-2 detection platform based on Ultra-fast RTX-PCR and Pyrococcus furiosus Argonaute-mediated Nucleic acid Detection (PAND) technology (URPAND). URPAND was achieved ultra-fast RTX-PCR process based on a thermostable RTX (exo-) with both reverse transcriptase and DNA polymerase activity. The URPAND can be completed RT-PCR and PAND to detect nucleic acid in one tube within 30 min. This method can specifically detect SARS-CoV-2 with a low detection limit of 100 copies/mL. The diagnostic results of clinical samples with one-tube URPAND displayed 100% consistence with RT-qPCR test. Moreover, URPAND was also applied to identify SARS-CoV-2 D614G mutant due to its single-nucleotide specificity. The URPAND platform is rapid, accurate, tube closed, one-tube, easy-to-operate and free of large instruments, which provides a new strategy to the detection of SARS-CoV-2 and other RNA viruses.


Subject(s)
Argonaute Proteins , COVID-19 , Pyrococcus furiosus , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , RNA, Viral/analysis , COVID-19/diagnosis , COVID-19/virology , Humans , Real-Time Polymerase Chain Reaction/methods , Biosensing Techniques/methods , COVID-19 Nucleic Acid Testing/methods
6.
PLoS One ; 19(5): e0304158, 2024.
Article in English | MEDLINE | ID: mdl-38787865

ABSTRACT

During the SARS-CoV-2 pandemic, many countries established wastewater (WW) surveillance to objectively monitor the level of infection within the population. As new variants continue to emerge, it has become clear that WW surveillance is an essential tool for the early detection of variants. The EU Commission published a recommendation suggesting an approach to establish surveillance of SARS-CoV-2 and its variants in WW, besides specifying the methodology for WW concentration and RNA extraction. Therefore, different groups have approached the issue with different strategies, mainly focusing on WW concentration methods, but only a few groups highlighted the importance of prefiltering WW samples and/or purification of RNA samples. Aiming to obtain high-quality sequencing data allowing variants detection, we compared four experimental conditions generated from the treatment of: i) WW samples by WW filtration and ii) the extracted RNA by DNase treatment, purification and concentration of the extracted RNA. To evaluate the best condition, the results were assessed by focusing on several sequencing parameters, as the outcome of SARS-CoV-2 sequencing from WW is crucial for variant detection. Overall, the best sequencing result was obtained by filtering the WW sample. Moreover, the present study provides an overview of some sequencing parameters to consider when optimizing a method for monitoring SARS-CoV-2 variants from WW samples, which can also be applied to any sample preparation methodology.


Subject(s)
COVID-19 , Filtration , RNA, Viral , SARS-CoV-2 , Wastewater , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Wastewater/virology , Humans , COVID-19/virology , COVID-19/diagnosis , RNA, Viral/genetics , RNA, Viral/isolation & purification , RNA, Viral/analysis , Filtration/methods
7.
Anal Methods ; 16(20): 3249-3255, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38726641

ABSTRACT

The past and present scenario of COVID-19 has revealed the necessity of simple point-of-care tests. When combined with the great advantages of amplification, lateral flow assay nucleic acid analysis represents a more sensitive molecular diagnostic technique compared to universal protein analysis. Room temperature operation, an enzyme-free nature, and in situ elongation make hybrid chain reaction amplification (HCR) a good candidate for amplified combined lateral flow assays (LFAs). Since dual modes of detection can not only satisfy different application scenarios, but also reduce the false-negative rate, in this paper, visual and fluorescent detection based on labelling with colloidal gold nanoparticles and fluorescence labelling were incorporated into a HCR integrated with a LFA. The detection assay was finished in 30 minutes. The linear relationship between the signal and the concentration of the characteristic segment in the COVID-19 ORF gene was demonstrated. The obtained detection limits of as low as 10 fM (6.02 × 103 copies per mL) and 1 fM (6.02 × 102 copies per mL), respectively, were comparable with those in the literature. The multi-site HCR amplification integrated with LFA of a 1053 bp nucleic acid chain was also preliminarily studied, and tri-site amplification was found to exhibit higher signal intensity than single-site amplification. This study provides a promising strategy for simple, sensitive, and wide-ranging detection of pathogenic bacteria.


Subject(s)
COVID-19 , Nucleic Acid Amplification Techniques , SARS-CoV-2 , SARS-CoV-2/genetics , Humans , COVID-19/diagnosis , Nucleic Acid Amplification Techniques/methods , Limit of Detection , Molecular Diagnostic Techniques/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Metal Nanoparticles/chemistry , RNA, Viral/analysis , RNA, Viral/genetics
8.
Sci Rep ; 14(1): 10612, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38719936

ABSTRACT

Molecular diagnostics involving nucleic acids (DNA and RNA) are regarded as extremely functional tools. During the 2020 global health crisis, efforts intensified to optimize the production and delivery of molecular diagnostic kits for detecting SARS-CoV-2. During this period, RT-LAMP emerged as a significant focus. However, the thermolability of the reagents used in this technique necessitates special low-temperature infrastructure for transport, storage, and conservation. These requirements limit distribution capacity and necessitate cost-increasing adaptations. Consequently, this report details the development of a lyophilization protocol for reagents in a colorimetric RT-LAMP diagnostic kit to detect SARS-CoV-2, facilitating room-temperature transport and storage. We conducted tests to identify the ideal excipients that maintain the molecular integrity of the reagents and ensure their stability during room-temperature storage and transport. The optimal condition identified involved adding 5% PEG 8000 and 75 mM trehalose to the RT-LAMP reaction, which enabled stability at room temperature for up to 28 days and yielded an analytical and diagnostic sensitivity and specificity of 83.33% and 90%, respectively, for detecting SARS-CoV-2. This study presents the results of a lyophilized colorimetric RT-LAMP COVID-19 detection assay with diagnostic sensitivity and specificity comparable to RT-qPCR, particularly in samples with high viral load.


Subject(s)
COVID-19 , Colorimetry , Freeze Drying , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Colorimetry/methods , Nucleic Acid Amplification Techniques/methods , Molecular Diagnostic Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , COVID-19 Nucleic Acid Testing/methods
9.
Anal Chem ; 96(19): 7479-7486, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38689560

ABSTRACT

In the pathogenesis of microglia, brain immune cells promote nitrergic stress by overproducing nitric oxide (NO), leading to neuroinflammation. Furthermore, NO has been linked to COVID-19 progression, which has caused significant morbidity and mortality. SARS-CoV-2 infection activates inflammation by releasing excess NO and causing cell death in human microglial clone 3 (HMC3). In addition, NO regulates lysosomal functions and complex machinery to neutralize pathogens through phagocytosis. Therefore, developing lysosome-specific NO probes to monitor phagocytosis in microglia during the COVID-19 infection would be a significant study. Herein, a unique synthetic strategy was adopted to develop a NO selective fluorescent probe, PDM-NO, which can discriminate activated microglia from their resting state. The nonfluorescent PDM-NO exhibits a turn-on response toward NO only at lysosomal pH (4.5-5.5). Quantum chemical calculations (DFT/TD-DFT/PCM) and photophysical study revealed that the photoinduced electron transfer (PET) process is pivotal in tuning optical properties. PDM-NO demonstrated good biocompatibility and lysosomal specificity in activated HMC3 cells. Moreover, it can effectively map the dynamics of lysosomal NO against SARS-CoV-2 RNA-induced neuroinflammation in HMC3. Thus, PDM-NO is a potential fluorescent marker for detecting RNA virus infection and monitoring phagocytosis in HMC3.


Subject(s)
COVID-19 , Fluorescent Dyes , Lysosomes , Microglia , Nitric Oxide , Phagocytosis , SARS-CoV-2 , Microglia/virology , Microglia/metabolism , SARS-CoV-2/isolation & purification , Humans , Lysosomes/metabolism , Nitric Oxide/metabolism , Nitric Oxide/analysis , COVID-19/virology , COVID-19/diagnosis , COVID-19/metabolism , Fluorescent Dyes/chemistry , RNA, Viral/analysis , RNA, Viral/metabolism , Neuroinflammatory Diseases , Cell Line , Phenotype
10.
Langmuir ; 40(22): 11534-11540, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38758706

ABSTRACT

Viral infections, such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), are some of the most dangerous threats to humans. SARS-CoV-2 has caused a global pandemic, highlighting the unprecedented demand for rapid and portable diagnostic methods. To meet these requirements, we designed a label-free colorimetric platform that combines the clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated proteins (Cas) 12a system for naked-eye detection (named LFP). This method utilizes reverse transcription loop-mediated isothermal amplification (RT-LAMP) and the trans-cleavage activity of the CRISPR/Cas12a system to increase the sensitivity and specificity of the reaction. This platform can detect as few as 4 copies/µL of RNA and produces no false positive results when tested against the influenza virus. To better meet the requirements of point-of-care (POC) detection, we developed a portable device that can be applied in resource-poor and densely populated regions. The LFP assay holds great potential for application in resource-limited settings, and the label-free gold nanoparticle (AuNPs) probe can reduce costs, making it suitable for large-scale screening. We expect that the LFP assay will be promising for the POC screening of COVID-19.


Subject(s)
Colorimetry , Gold , Metal Nanoparticles , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Gold/chemistry , Colorimetry/methods , Colorimetry/instrumentation , Metal Nanoparticles/chemistry , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/instrumentation , Humans , COVID-19/diagnosis , COVID-19/virology , CRISPR-Cas Systems , Clustered Regularly Interspaced Short Palindromic Repeats , Molecular Diagnostic Techniques
11.
Anal Chem ; 96(22): 9167-9176, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38761141

ABSTRACT

The detection of virus RNA in wastewater has been established as a valuable method for monitoring Coronavirus disease 2019. Carbon nanomaterials hold potential application in separating virus RNA owing to their effective adsorption and extraction capabilities. However, carbon nanomaterials have limited separability under homogeneous aqueous conditions. Due to the stabilities in their nanostructure, it is a challenge to efficiently immobilize them onto magnetic beads for separation. Here, we develop a porous agarose layered magnetic graphene oxide (GO) nanocomposite that is prepared by agglutinating ferroferric oxide (Fe3O4) beads and GO with agarose into a cohesive whole. With an average porous size of approximately 500 nm, the porous structure enables the unhindered entry of virus RNA, facilitating its interaction with the surface of GO. Upon the application of a magnetic field, the nucleic acid can be separated from the solution within a few minutes, achieving adsorption efficiency and recovery rate exceeding 90% under optimized conditions. The adsorbed nucleic acid can then be preserved against complex sample matrix for 3 days, and quantitatively released for subsequent quantitative reverse transcription polymerase chain reaction (RT-qPCR) detection. The developed method was successfully utilized to analyze wastewater samples obtained from a wastewater treatment plant, detecting as few as 10 copies of RNA molecules per sample. The developed aMGO-RT-qPCR provides an efficient approach for monitoring viruses and will contribute to wastewater-based surveillance of community infections.


Subject(s)
Graphite , Nanocomposites , RNA, Viral , Sepharose , Wastewater , Graphite/chemistry , Wastewater/virology , Wastewater/chemistry , RNA, Viral/analysis , RNA, Viral/isolation & purification , Sepharose/chemistry , Nanocomposites/chemistry , Porosity , Adsorption
12.
Biosens Bioelectron ; 259: 116400, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38776799

ABSTRACT

CRISPR based nucleic acid detection technology provides a deployable approach to point of care testing. While, there remain challenges limiting its practical applications, such as the need for pre-amplification and the long turnaround time. Here, we present a self-cascade signal amplification method with LwaCas13a and an artificially designed "U" rich RNA of stem-loop structure (URH) for pre-amplification-free ultra-fast and ultra-sensitive point-of-care testing (PASSPORT). The PASSPORT system contains: URH, crRNA targeted the URH, crRNA targeted the interesting RNA, fluorescent RNA reporter and LwaCas13a. The assay realized the detection of 100 copies/mL, within 5 min. The PASSPORT platform was further adopted for the detection of marker gene from SASR-CoV-2 and Severe fever with thrombocytopenia syndrome virus (SFTSV), respectively, and 100% accuracy for the analysis of clinical specimens (100 SASR-CoV-2 specimens and 16 SFTSV specimens) was obtained. Integrated with a lateral flow assay device, this assay could provide an alternative platform for the development of point of care testing (POCT) biosensors. PASSPORT has the potential to enable sensitive, specific, user-friendly, rapid, affordable, equipment-free and point-of-care testing for the purpose of large-scale screening and in case of epidemic outbreak.


Subject(s)
Biosensing Techniques , COVID-19 , CRISPR-Cas Systems , Point-of-Care Testing , SARS-CoV-2 , Biosensing Techniques/methods , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , COVID-19/virology , COVID-19/diagnosis , RNA, Viral/genetics , RNA, Viral/analysis , RNA, Viral/isolation & purification , Nucleic Acid Amplification Techniques/methods , Point-of-Care Systems , Limit of Detection
13.
Sci Rep ; 14(1): 12187, 2024 05 28.
Article in English | MEDLINE | ID: mdl-38806581

ABSTRACT

This was the first longitudinal study to analyze dental clinic wastewater to estimate asymptomatic SARS-CoV-2 infection trends in children. We monitored wastewater over a 14-month period, spanning three major COVID-19 waves driven by the Alpha, Delta, and Omicron variants. Each Saturday, wastewater was sampled at the Pediatric Dental Clinic of the only dental hospital in Japan's Saitama Prefecture. The relationship between the weekly number of cases in Saitama Prefecture among residents aged < 10 years (exposure) and wastewater SARS-CoV-2 RNA detection (outcome) was examined. The number of cases was significantly associated with wastewater SARS-CoV-2 RNA positivity (risk ratio, 5.36; 95% confidence interval, 1.72-16.67; Fisher's exact test, p = 0.0005). A sample from Week 8 of 2022 harbored the Omicron variant. Compared to sporadic individual testing, this approach allows continuous population-level surveillance, which is less affected by healthcare seeking and test availability. Since wastewater from pediatric dental clinics originates from the oral cavities of asymptomatic children, such testing can provide important information regarding asymptomatic COVID-19 in children, complementing clinical pediatric data.


Subject(s)
COVID-19 , Dental Clinics , SARS-CoV-2 , Wastewater , Humans , COVID-19/epidemiology , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Wastewater/virology , Child , Child, Preschool , Japan/epidemiology , Female , Male , Longitudinal Studies , RNA, Viral/genetics , RNA, Viral/analysis , Infant
14.
Mikrochim Acta ; 191(6): 339, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789855

ABSTRACT

Loop-mediated isothermal amplification (LAMP) is a molecular diagnosis technology with the advantages of isothermal reaction conditions and high sensitivity. However, the LAMP reactions are prone to producing false-positive results and thus are usually less reliable. This study demonstrates a gold nanoparticle (AuNP)-assisted colorimetric LAMP technique for diagnosing SARS-CoV-2, which aims to overcome the false-positive results. The AuNPs were functionalized with E gene probes, specifically tailored to bind to the amplified E-gene LAMP product, using the freezing method. Varied salt concentration and AuNP/probe combinations were tested for the highest visual performance. The experiments were conducted on synthetic SARS-CoV-2 RNA (Omicron variant), as well as on clinical samples. The assay showed an exceptional sensitivity of 8.05 fg of LAMP amplicon mixture (0.537 fg/µL). The average reaction time was ~ 30 min. In conclusion, AuNP-assisted LAMP detection will not identify any potential unspecific amplification, which helps to improve the efficiency and reliability of LAMP assays in point-of-care applications. The freezing method to functionalize the AuNPs with probes simplifies the assay, which can be utilized in further diagnostic studies.


Subject(s)
COVID-19 , Colorimetry , Gold , Metal Nanoparticles , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Gold/chemistry , Metal Nanoparticles/chemistry , Colorimetry/methods , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/genetics , Humans , COVID-19/diagnosis , COVID-19/virology , RNA, Viral/genetics , RNA, Viral/analysis , Freezing , Molecular Diagnostic Techniques/methods , Limit of Detection
15.
Sci Rep ; 14(1): 12125, 2024 05 27.
Article in English | MEDLINE | ID: mdl-38802360

ABSTRACT

Emergence of Coronavirus disease 2019 (COVID-19) pandemic has posed a huge threat to public health. Rapid and reliable test to diagnose infected subjects is crucial for disease spread control. We developed a colorimetric test for COVID-19 detection using a Colorimetric Assay based on thiol-linked RNA modified gold nanoparticles (AuNPs) and oligonucleotide probes. This method was conducted on RNA from 200 pharyngeal swab samples initially tested by Real-Time polymerase chain reaction (RT-PCR) as gold standard. A specific oligonucleotide probe designed based on ORF1ab of COVID-19 was functionalized with AuNPs-probe conjugate. The exposure of AuNP-probe to isolated RNA samples was tested using hybridization. In this comparative study, the colorimetric functionalized AuNPs assay exhibited a detection limit of 25 copies/µL. It was higher in comparison to the RT-PCR method, which could only detect 15 copies/µL. The results demonstrated 100% specificity and 96% sensitivity for the developed method. Herein, we developed an incredibly rapid, simple and cost-effective Colorimetric Assay lasting approximately 30 min which could process considerably higher number of COVID-19 samples compared to the RT-PCR. This AuNP-probe conjugate colorimetric method could be considered the optimum alternatives for conventional diagnostic tools especially in over-populated and/or low-income countries.


Subject(s)
COVID-19 , Colorimetry , Gold , Metal Nanoparticles , Nasopharynx , RNA, Viral , SARS-CoV-2 , Sensitivity and Specificity , Colorimetry/methods , Humans , COVID-19/diagnosis , COVID-19/virology , Metal Nanoparticles/chemistry , Gold/chemistry , Nasopharynx/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , RNA, Viral/analysis , RNA, Viral/genetics , RNA, Viral/isolation & purification , Limit of Detection , Oligonucleotide Probes/genetics , COVID-19 Nucleic Acid Testing/methods , Real-Time Polymerase Chain Reaction/methods , COVID-19 Testing/methods
16.
Anal Chim Acta ; 1309: 342693, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772660

ABSTRACT

BACKGROUND: CRISPR-Cas12a based one-step assays are widely used for nucleic acid detection, particularly for pathogen detection. However, the detection capability of the one-step assay is reduced because the Cas12a protein competes with the isothermal amplification enzymes for the target DNA and cleaves it. Therefore, the key to improving the sensitivity of the one-step assay is to address the imbalance between isothermal amplification and CRISPR detection. In previous study, we developed a Cas12a one-step assay using single-stranded DNA (ssDNA)-modified crRNA (mD-crRNA) and applied this method for the detection of pathogenic DNA. RESULTS: Here, we utilized mD-crRNA to establish a sensitive one-step assay that enables the visual detection of SARS-CoV-2 under ultraviolet light, achieving a detection limit of 5 aM without cross-reactivity. The sensitivity of mD-crRNA in the one-step assay was 100-fold higher than that of wild-type crRNA. Mechanistic studies revealed that the addition of ssDNA at the 3' end of mD-crRNA attenuates the binding affinity between the Cas12a-mD-crRNA complex and the target DNA. Consequently, this reduction in binding affinity decreases the cis-cleavage activity of Cas12a, mitigating its cleavage of the target DNA in the one-step assay. As a result, there is an augmentation in the amplification and accumulation of target DNA, thereby enhancing detection sensitivity. In the clinical testing of 40 SARS-CoV-2 RNA samples, the concordance between the results of the one-step assay and known qPCR results was 97.5 %. SIGNIFICANCE: The one-step assay using mD-crRNA proves to be highly sensitive and specificity and visually effective for the detection of SARS-CoV-2. Our study delves into the application of the mD-crRNA-mediated one-step assay in nucleic acid detection and its associated reaction mechanism. This holds great significance in addressing the inherent incompatibility issues between isothermal amplification and CRISPR detection.


Subject(s)
COVID-19 , DNA, Single-Stranded , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , DNA, Single-Stranded/chemistry , DNA, Single-Stranded/genetics , Nucleic Acid Amplification Techniques/methods , Humans , RNA, Viral/analysis , RNA, Viral/genetics , COVID-19/diagnosis , COVID-19/virology , Limit of Detection , CRISPR-Cas Systems/genetics , Endodeoxyribonucleases/chemistry , Endodeoxyribonucleases/metabolism , Endodeoxyribonucleases/genetics , CRISPR-Associated Proteins/metabolism , CRISPR-Associated Proteins/genetics , Bacterial Proteins
17.
Viruses ; 16(5)2024 05 04.
Article in English | MEDLINE | ID: mdl-38793611

ABSTRACT

Coronaviruses (CoVs), a subfamily of Orthocoronavirinae, are viruses that sometimes present a zoonotic character. Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) is responsible for the recent outbreak of COVID-19, which, since its outbreak in 2019, has caused about 774,593,066 confirmed cases and 7,028,881 deaths. Aereosols are the main route of transmission among people; however, viral droplets can contaminate surfaces and fomites as well as particulate matter (PM) in suspensions of natural and human origin. Honey bees are well known bioindicators of the presence of pollutants and PMs in the environment as they can collect a great variety of substances during their foraging activities. The aim of this study was to evaluate the possible role of honey bees as bioindicators of the prevalence SARS-CoV-2. In this regard, 91 samples of honey bees and 6 of honey were collected from different apiaries of Campania region (Southern Italy) in four time periods from September 2020 to June 2022 and were analyzed with Droplet Digital RT-PCR for SARS-CoV-2 target genes Orf1b and N. The screening revealed the presence of SARS-CoV-2 in 12/91 in honey bee samples and in 2/6 honey samples. These results suggest that honey bees could also be used as indicators of outbreaks of airborne pathogens such as SARS-CoV-2.


Subject(s)
COVID-19 , Honey , SARS-CoV-2 , Animals , Bees/virology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Honey/analysis , COVID-19/virology , COVID-19/epidemiology , COVID-19/transmission , COVID-19/diagnosis , Italy/epidemiology , RNA, Viral/genetics , RNA, Viral/analysis , Humans , Reverse Transcriptase Polymerase Chain Reaction/methods
18.
Sci Rep ; 14(1): 8700, 2024 04 15.
Article in English | MEDLINE | ID: mdl-38622191

ABSTRACT

HIV infection has been a global public health threat and overall reported ~ 40 million deaths. Acquired immunodeficiency syndrome (AIDS) is attributed to the retroviruses (HIV-1/2), disseminated through various body fluids. The temporal progression of AIDS is in context to the rate of HIV-1 infection, which is twice as protracted in HIV-2 transmission. Q-PCR is the only available method that requires a well-developed lab infrastructure and trained personnel. Micro-PCR, a portable Q-PCR device, was developed by Bigtec Labs, Bangalore, India. It is simple, accurate, fast, and operationalised in remote places where diagnostic services are inaccessible in developing countries. This novel micro-PCR determines HIV-1 and HIV-2 viral load using a TruePrep™ extractor device for RNA isolation. Five ml blood samples were collected at the blood collection centre at AIIMS, New Delhi, India. Samples were screened for serology, and a comparison of HIV-1/2 RNA was done between qPCR and micro-PCR in the samples. The micro-PCR assay of HIV-RNA has compared well with those from real-time PCR (r = 0.99, i < 0.002). Micro-PCR has good inter and intra-assay reproducibility over a wide dynamic range (1.0 × 102-1.0 × 108 IU/ml). The linear dynamic range was 102-108 IU/ml. The clinical and analytical specificity of the assay was comparable, i.e., 100%. Intra-assay and inter-assay coefficients of variation ranged from 1.17% to 3.15% and from 0.02% to 0.46%, respectively. Moreover, due to the robust, simple, and empirical method, the Probit analysis has also been done for qPCR LODs to avoid uncertainties in target recoveries. The micro-PCR is reliable, accurate, and reproducible for early detection of HIV-1 and HIV-2 viral loads simultaneously. Thus, it can easily be used in the field and in remote places where quantification of both HIV-1/2 is not reachable.


Subject(s)
Acquired Immunodeficiency Syndrome , HIV Infections , HIV Seropositivity , HIV-1 , Humans , HIV-1/genetics , Reproducibility of Results , Sensitivity and Specificity , RNA, Viral/analysis , India , Real-Time Polymerase Chain Reaction/methods , HIV-2/genetics , Viral Load/methods
19.
JAMA ; 331(16): 1418-1419, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38557893
20.
J Appl Microbiol ; 135(4)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38637309

ABSTRACT

AIMS: To monitor severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) RNA contamination in vehicles operating in England during the pandemic, to better understand transmission risk of SARS-CoV-2 on public transport. METHODS AND RESULTS: We collected 1314 surface samples between December 2020 and April 2022 on trains and buses managed by five different transport operators. The presence of SARS-CoV-2 RNA was investigated through reverse transcription polymerase chain reaction (RT-PCR). SARS-CoV-2 RNA was found on 197 (15%) of the 1314 surfaces sampled, including seat head rests, handholds, and air extract grilles, but the levels of RNA recovered on those samples (median value of 23.4, interquartile range: 14.3-35.4, N gene copies per extraction) made the presence of infectious virus at the time of sampling extremely unlikely. However, detection rates varied over time with peaks broadly coinciding with times of high community transmission, when it was more likely that people infected with SARS-CoV-2 were travelling on public transport. CONCLUSION: During the pandemic, and as in other public spaces, low levels of SARS-CoV-2 RNA were found on surfaces associated with public transport.


Subject(s)
COVID-19 , RNA, Viral , SARS-CoV-2 , COVID-19/transmission , COVID-19/virology , COVID-19/epidemiology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , England/epidemiology , RNA, Viral/genetics , RNA, Viral/analysis , RNA, Viral/isolation & purification , Humans , Longitudinal Studies , Motor Vehicles , Transportation
SELECTION OF CITATIONS
SEARCH DETAIL
...