Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.553
Filter
1.
Turk Kardiyol Dern Ars ; 52(4): 260-268, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38829631

ABSTRACT

OBJECTIVE: Ionizing radiation has long been used in the medical field. Catheter laboratories (cath labs) are recognized as areas where radiation exposure is notably high. This study aims to examine the levels of radiation exposure during various interventional procedures to raise awareness of this issue in Türkiye. METHODS: This study evaluated the procedure radiation doses (n = 2804) in the cath labs of four public hospitals with distinct characteristics. Radiation dose evaluation was conducted using Cumulative Air Kerma (CAK). The Kolmogorov-Smirnov test, Kruskal-Wallis H test, independent T-test, and Pearson correlation coefficient were utilized to analyze the data. A p-value of < 0.05 was considered statistically significant. Data were analyzed using IBM® Statistical Package for the Social Sciences (SPSS®) STATISTICS Version 26.0.0.0 (IBM Corporation, Armonk, New York, USA). RESULTS: The procedure radiation doses in the cath labs were documented. The findings are largely consistent with the literature. Notably, several outlier cases with extremely high radiation doses were identified [CAK (min-max) = 0.12 - 9.9 Gy]. Procedures such as chronic total occlusion (CTO) [Mean CAK: 3.8 (± 1.5) Gy] and percutaneous coronary interventions (PCI) [Mean CAK: 1.5 (± 1.4) Gy] were associated with high doses. Additionally, personnel attitudes toward radiation optimization in cath labs were found to be inadequate. CONCLUSION: The incidence of high radiation exposure during interventional procedures may be higher than expected in Türkiye. Further research is necessary to identify predictors and implement preventive measures to reduce these rates. For this purpose, establishing diagnostic radiation reference levels (DRLs) could help monitor national radiation levels.


Subject(s)
Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/prevention & control , Radiation Exposure/prevention & control , Turkey , Cardiology , Attitude of Health Personnel , Female , Male
2.
J Urol ; 211(6): 735-742, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38721932

ABSTRACT

PURPOSE: Fluoroscopy is usually required during retrograde intrarenal surgery (RIRS). Although fluoroscopy is considered necessary for effective and safe RIRS, there is growing awareness regarding radiation exposure risk to patients and surgeons. We conducted a multicenter-based, randomized, controlled trial to compare the safety and effectiveness of radiation-free (RF) RIRS with radiation-usage (RU) RIRS for kidney stone management. MATERIALS AND METHODS: From August 2020 to April 2022, patients with a unilateral kidney stone (≤20 mm) eligible for RIRS were prospectively enrolled in 5 tertiary medical centers after randomization and divided into the RF and RU groups. RIRS was performed using a flexible ureteroscope with a holmium:YAG laser. The primary end point of this study was the success rate, defined as complete stone-free or residual fragments with asymptomatic kidney stones ≤ 3 mm. The secondary end point of this study was ascertaining the safety of RF RIRS. The success rates were analyzed using a noninferiority test. RESULTS: Of the 140 consecutive randomized participants, 128 patients completed this study (RF: 63; RU: 65). The success rates (78% vs 80%, P = .8) were not significantly different between the groups. The rate of high-grade (grade 2-4) ureter injury was not significantly higher in the RF group compared to the RU group (RF = 3 [4.8%] vs RU = 2 [3.1%], P = .6). In RF RIRS, the success rate was noninferior compared to RU RIRS (the difference was 2.2% [95% CI, 0.16-0.12]). CONCLUSIONS: This study demonstrated that the surgical outcomes of RF RIRS were noninferior to RU RIRS.


Subject(s)
Kidney Calculi , Humans , Female , Male , Middle Aged , Prospective Studies , Kidney Calculi/surgery , Treatment Outcome , Fluoroscopy , Aged , Adult , Ureteroscopy/methods , Ureteroscopy/adverse effects , Lasers, Solid-State/therapeutic use , Radiation Exposure/prevention & control , Kidney/surgery
3.
World J Urol ; 42(1): 310, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722553

ABSTRACT

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Subject(s)
Occupational Exposure , Radiation Exposure , Urologists , Humans , Urology , Urologic Surgical Procedures
4.
J Radiol Prot ; 44(2)2024 May 28.
Article in English | MEDLINE | ID: mdl-38722296

ABSTRACT

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.


Subject(s)
Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/analysis , Child , Cardiac Catheterization , Radiation Protection , Lens, Crystalline/radiation effects , Radiography, Interventional , Radiation Exposure/analysis
5.
Acta Odontol Scand ; 83: 296-301, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38745537

ABSTRACT

OBJECTIVES: To estimate radiation risk to children and adolescents during orthodontic treatment by retrieving number and type of radiographs from the patient records. MATERIAL AND METHODS: Radiographs, along with justifications for radiation exposure, were obtained retrospectively from the patient records of 1,790 children and adolescents referred to two Swedish orthodontic clinics. Data were grouped according to treatment stage: treatment planning, treatment, and follow-up. Estimated risk was calculated using the concept of effective dose. RESULTS: Each patient had received around seven radiographs for orthodontic purposes. The most common exposures during treatment planning were one panoramic, one lateral, and three intraoral periapical radiographs. A small number of patients received a tomographic examination (8.2%). Few justifications for treatment planning and follow-up, but more in the actual treatment stage, had been recorded. The most common examinations were to assess root resorption and the positions of unerupted teeth, or simply carry out an unspecified control. The estimated risk of developing fatal cancer was considered low. The radiation risk from orthodontic treatment was equivalent to about 5-10 days of natural background radiation. CONCLUSIONS: Children and adolescents sometimes undergo multiple radiographic examinations, but despite the low radiation burden, accumulated radiation exposure should be considered and justified in young patients.


Subject(s)
Radiation Exposure , Humans , Adolescent , Child , Male , Female , Retrospective Studies , Radiation Exposure/adverse effects , Sweden , Orthodontics , Radiation Dosage , Radiography, Dental/adverse effects
7.
Ital J Pediatr ; 50(1): 100, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760836

ABSTRACT

BACKGROUND: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project aims to improve knowledge on the effects of medical exposure to ionizing radiation (IR) received during childhood. One of its objectives is to build a consolidated European cohort of pediatric patients who have undergone cardiac catheterization (Cath) procedures, with the goal of enhancing the assessment of long-term radiation-associated cancer risk. The purpose of our study is to provide a detailed description of the Italian cohort contributing to the HARMONIC project, including an analysis of cumulative IR exposure, reduction trend over the years and an overview of the prospective collection of biological samples for research in this vulnerable population. METHODS: In a single-center retrospective cohort study, a total of 584 patients (323 males) with a median age of 6 (2-13) years, referred at the Pediatric Cardiology in Niguarda Hospital from January 2015 to October 2023, were included. Biological specimens from a subset of 60 patients were prospectively collected for biobanking at baseline, immediately post-procedure and after 12 months. RESULTS: Two hundred fifty-nine (44%) patients were under 1 year old at their first procedure. The median KAP/weight was 0.09 Gy·cm2/kg (IQR: 0.03-0.20), and the median fluoroscopy time was 8.10 min (IQR: 4.00-16.25). KAP/weight ratio showed a positive correlation with the fluoroscopy time (Spearman's rho = 0.679, p < 0.001). Significant dose reduction was observed either after implementation of an upgraded technology system and a radiation training among staff. The Italian cohort includes 1858 different types of specimens for Harmonic biobank, including blood, plasma, serum, clot, cell pellet/lymphocytes, saliva. CONCLUSIONS: In the Italian Harmonic cohort, radiation dose in cardiac catheterization varies by age and procedure type. An institution's radiological protection strategy has contributed to a reduction in radiation dose over time. Biological samples provide a valuable resource for future research, offering an opportunity to identify potential early biomarkers for health surveillance and personalized risk assessment.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Radiation Exposure , Humans , Italy , Male , Child , Female , Child, Preschool , Adolescent , Retrospective Studies , Radiation Exposure/adverse effects , Fluoroscopy/adverse effects , Radiation Dosage , Cohort Studies
8.
BMC Gastroenterol ; 24(1): 173, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762503

ABSTRACT

BACKGROUND: There have been previous studies and earlier systematic review on the relationship between inflammatory bowel disease (IBD) and radiation exposure. With the diversification of current test methods, this study intended to conduct a meta-analysis to evaluate the IBD radiation exposure in recent years. METHODS: Three databases (PUBMED, EMBASE, and MEDICINE) for relevant literature up to May 1, 2023 were searched. The statistical data meeting requirements were collated and extracted. RESULTS: 20 papers were enrolled. The overall high radiation exposure rate was 15% (95% CI = [12%, 19%]) for CD and 5% (95% CI = [3%, 7%]) for UC. The pooled result found that high radiation exposure rate was 3.44 times higher in CD than in UC (OR = 3.44, 95% CI = [2.35, 5.02]). Moreover, the average radiation exposure level in CD was 12.77 mSv higher than that in UC (WMD = 12.77, 95% CI = [9.93, 15.62] mSv). Furthermore, radiation exposure level of CD after 2012 was higher than those before 2012 (26.42 ± 39.61vs. 23.76 ± 38.46 mSv, P = 0.016), while UC did not show similar result (11.99 ± 27.66 vs. 10.01 ± 30.76 mSv, P = 0.1). Through subgroup analysis, it was found that disease duration (WMD = 2.75, 95% CI = [0.10, 5.40] mSv), complications (OR = 5.09, 95% CI = [1.50, 17.29]), and surgical history (OR = 5.46, 95% CI = [1.51, 19.69]) significantly increased the proportion of high radiation exposure. CONCLUSION: This study found that radiation exposure level of IBD patients was high, which revealed the radiation risk in the process of diagnosis and treatment of IBD patients. In the future, longer follow-up and prospective studies are needed to reveal the relationship between high radiation exposure and solid tumorigenesis.


Subject(s)
Radiation Exposure , Humans , Radiation Exposure/adverse effects , Colitis, Ulcerative , Inflammatory Bowel Diseases , Crohn Disease , Radiation Dosage
9.
J Environ Radioact ; 276: 107444, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38723324

ABSTRACT

The conceptual dynamic ecosystem model was developed to evaluate the self-organization of trophic structure in ecosystems during the course of biogenic succession. This model was applied to analyze the possible changes in the ecosystem under impact of the anthropogenic physical stressor - chronic exposure to ionizing irradiation. The model predicts that amount of the limiting biogenic nutrient in the environment can modify the ecological effects of ionizing radiation. Negative effects of the chronic exposure are less significant in ecosystems with high food supply. The model does not show presence of any ecological effect of radiation at the exposure rates less than the derived consideration reference levels, obtained by International Commission on Radiological Protection for individual nature organisms. If the dose rates are higher than those levels, radiation exposure can affect ecological interactions between species. The model shows that environmental hormesis can exist in the ecosystems, impacted by the chronic radiation exposure. The reason of this effect is change of the ecological coefficients (for example, decrease of the predation rate), which in the certain range of parameters leads to the increase of biomasses of all species at the same amount of the limiting biogenic nutrient in ecosystem. Trigger regimes exist in the model ecosystem with mixed-feeding consumers. Within the trigger area, the realization of a particular trophic structure depends on initial species biomasses. A hysteresis phenomenon exists in such ecosystems, which means that the successive changes in the trophic structures realized following the increase of the influencing factor are not reproduced in the same order if the influencing factor was gradually decreased back to its previous values. The model predicts for this case, that the radioactively contaminated ecosystem does not necessarily return to its initial trophic structure, despite the dose rate decreases to the initial levels.


Subject(s)
Ecosystem , Food Chain , Radiation Monitoring , Radiation Exposure , Models, Theoretical
11.
Article in English | MEDLINE | ID: mdl-38814258

ABSTRACT

Surgical ankle fractures pose a unique situation because both podiatrists and orthopaedic surgeons manage these injuries. Intraoperative fluoroscopy is routinely used; however, excessive radiation can be harmful to both the patient and the surgical team. The primary goal of this study was to determine whether there is a difference in the amount of intraoperative radiation exposure during ankle fracture open reduction and internal fixation (ORIF) when performed by orthopaedic surgeons versus podiatrists. This is a retrospective review of patients who underwent ankle fracture ORIF at an urban level I trauma center between January 1st, 2018, and April 1st, 2023. The electronic health record was queried using International Classification of Diseases nine and 10 codes associated with ankle fractures. Patients aged older than 18 years with an ankle fracture managed surgically were included. Subjects were then stratified by procedure. The mean total radiation dose (mRad) and mean total fluoroscopic time (seconds) were then compared between those performed by orthopaedic surgeons and podiatrists. Of the 333 included procedures, 186 were done by orthopaedic surgeons and 147 were done by podiatrists. Using multiple linear regression analysis to control for age, sex, race, ethnicity, and body mass index, patients undergoing isolated malleolus ORIF with syndesmosis repair performed by orthopaedic surgery were found to have a significantly lower mean fluoroscopic time compared with those performed by podiatry (68.4 s versus 104.8 s; P = 0.028). In addition, trimalleolar ORIF with syndesmotic repair performed by orthopaedic surgery had a significantly lower mean total radiation dose compared with those performed by podiatry (244.6 mRad v 565.6 mRad; P = 0.009). Patients and surgical teams are exposed to markedly less radiation in isolated malleolar and trimalleolar fracture ORIF with syndesmosis repair when performed by an orthopaedic surgeon as compared with those performed by a podiatrist.


Subject(s)
Ankle Fractures , Fracture Fixation, Internal , Open Fracture Reduction , Radiation Exposure , Humans , Fluoroscopy , Ankle Fractures/surgery , Ankle Fractures/diagnostic imaging , Retrospective Studies , Male , Female , Fracture Fixation, Internal/methods , Middle Aged , Adult , Podiatry , Aged , Radiation Dosage , Intraoperative Period , Orthopedics
12.
PLoS One ; 19(5): e0300883, 2024.
Article in English | MEDLINE | ID: mdl-38758927

ABSTRACT

Development of novel biodosimetry assays and medical countermeasures is needed to obtain a level of radiation preparedness in the event of malicious or accidental mass exposures to ionizing radiation (IR). For biodosimetry, metabolic profiling with mass spectrometry (MS) platforms has identified several small molecules in easily accessible biofluids that are promising for dose reconstruction. As our microbiome has profound effects on biofluid metabolite composition, it is of interest how variation in the host microbiome may affect metabolomics based biodosimetry. Here, we 'knocked out' the microbiome of male and female C57BL/6 mice (Abx mice) using antibiotics and then irradiated (0, 3, or 8 Gy) them to determine the role of the host microbiome on biofluid radiation signatures (1 and 3 d urine, 3 d serum). Biofluid metabolite levels were compared to a sham and irradiated group of mice with a normal microbiome (Abx-con mice). To compare post-irradiation effects in urine, we calculated the Spearman's correlation coefficients of metabolite levels with radiation dose. For selected metabolites of interest, we performed more detailed analyses using linear mixed effect models to determine the effects of radiation dose, time, and microbiome depletion. Serum metabolite levels were compared using an ANOVA. Several metabolites were affected after antibiotic administration in the tryptophan and amino acid pathways, sterol hormone, xenobiotic and bile acid pathways (urine) and lipid metabolism (serum), with a post-irradiation attenuative effect observed for Abx mice. In urine, dose×time interactions were supported for a defined radiation metabolite panel (carnitine, hexosamine-valine-isoleucine [Hex-V-I], creatine, citric acid, and Nε,Nε,Nε-trimethyllysine [TML]) and dose for N1-acetylspermidine, which also provided excellent (AUROC ≥ 0.90) to good (AUROC ≥ 0.80) sensitivity and specificity according to the area under the receiver operator characteristic curve (AUROC) analysis. In serum, a panel consisting of carnitine, citric acid, lysophosphatidylcholine (LysoPC) (14:0), LysoPC (20:3), and LysoPC (22:5) also gave excellent to good sensitivity and specificity for identifying post-irradiated individuals at 3 d. Although the microbiome affected the basal levels and/or post-irradiation levels of these metabolites, their utility in dose reconstruction irrespective of microbiome status is encouraging for the use of metabolomics as a novel biodosimetry assay.


Subject(s)
Mice, Inbred C57BL , Animals , Mice , Female , Male , Radiation Exposure , Microbiota/radiation effects , Metabolomics/methods , Metabolome/radiation effects , Radiation, Ionizing
13.
J Radiol Prot ; 44(2)2024 May 17.
Article in English | MEDLINE | ID: mdl-38722292

ABSTRACT

According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr-1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant's lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant's lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: 'assisted ventilation,' 'head holding,' 'body holding,' and 'raising patient's arm.' The air kerma of lens position was not significantly different for each assistance type (p< 0.05, Kruskal-Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. 'Raising patient's arm' and 'head holding' exhibited stronger correlations, which required less table movement during the CT scan than 'assisted ventilation' and 'body holding'.


Subject(s)
Lens, Crystalline , Occupational Exposure , Radiation Dosage , Tomography, X-Ray Computed , Lens, Crystalline/radiation effects , Humans , Occupational Exposure/analysis , Radiation Protection , Radiation Exposure/analysis
14.
Radiat Prot Dosimetry ; 200(8): 745-754, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38702838

ABSTRACT

This study analysed the occupational dose in Korean pressurized heavy-water reactors (PHWRs) and identified tasks involving high radiation exposure. The average individual dose was sufficiently low to be below the annual effective dose limit for radiation workers and is even lower than the dose limit for the general public. However, some workers received relatively higher doses than others. Furthermore, most PHWR workers are exposed to radiation during planned maintenance periods. In this study, the radiation dose was normalized (radiation dose per unit time) to determine the high-radiation-exposure tasks in Korean PHWRs. Consequently, end-fitting lapping, delayed neutron tube work and fuel channel fixed-end change tasks were identified as high-radiation-exposure tasks in Korean PHWRs. If appropriate radiation protection measures are prioritized for the identified high-dose exposure tasks, optimization of radiological protection will be effectively achieved by reducing the dose that is relatively higher than the average.


Subject(s)
Occupational Exposure , Radiation Dosage , Radiation Monitoring , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Humans , Republic of Korea , Radiation Monitoring/methods , Radiation Monitoring/instrumentation , Radiation Protection/instrumentation , Radiation Exposure/analysis , Nuclear Reactors , Water
15.
Radiat Prot Dosimetry ; 200(8): 755-762, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38702851

ABSTRACT

This study focuses on patient radiation exposure in interventional neuroradiology (INR) procedures, a field that has advanced significantly since its inception in the 1980s. INR employs minimally invasive techniques to treat complex cerebrovascular diseases in the head, neck, and spine. The study establishes diagnostic reference levels (DRLs) for three clinical indications (CIs): stroke (S), brain aneurysms (ANs), and brain arteriovenous malformation (AVM). Data from 209 adult patients were analyzed, and DRLs were determined in terms of various dosimetric and technical quantities. For stroke, the established DRLs median values were found to be 78 Gy cm2, 378 mGy, 118 mGy, 12 min, 442 images, and 15 runs. Similarly, DRLs for brain AN are 85 Gy cm2, 611 mGy, 95.5 mGy, 19.5, 717 images, and 26 runs. For brain AVM, the DRL's are 180 Gy cm2, 1144 mGy, 537 mGy, 36 min, 1375 images, and 31 runs. Notably, this study is unique in reporting DRLs for specific CIs within INR procedures, providing valuable insights for optimizing patient safety and radiation exposure management.


Subject(s)
Radiation Dosage , Humans , Adult , Male , Middle Aged , Female , Aged , Radiation Exposure/analysis , Intracranial Arteriovenous Malformations/radiotherapy , Intracranial Arteriovenous Malformations/diagnostic imaging , Stroke/diagnostic imaging , Intracranial Aneurysm/diagnostic imaging , Diagnostic Reference Levels , Neuroradiography/methods , Aged, 80 and over , Young Adult
16.
Radiat Prot Dosimetry ; 200(8): 763-769, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38712384

ABSTRACT

Veterinary practitioners and other personnel involved in the examination are exposed to ionizing radiation while performing portable radiographs on horses. An online survey was distributed to all Veterinary Council of Ireland-registered practices where the self-reported practice profile is at least 20% equine work. The survey contained questions relating to radiation safety training, protocols, personal dosimetry and lead protection usage, repeat exposures, sedation, and personnel roles during the examination. The aim of the survey was to document the current radiation safety practices of equine veterinary practitioners during portable radiography. The results showed that although adherence to guidance set out by the Environmental Protection Agency (EPA) is reasonably good, compliance rates can be improved. Personal dosemeter usage and repeat rate reduction could particularly benefit from further improvement. This is of the utmost importance in ensuring that occupational radiation exposure to veterinary practitioners is kept to an absolute minimum during their daily practice.


Subject(s)
Occupational Exposure , Radiation Protection , Ireland , Horses , Animals , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Humans , Surveys and Questionnaires , Radiography/statistics & numerical data , Radiography/standards , Radiography/adverse effects , Veterinarians , Radiation Dosage , Radiation Exposure/analysis
17.
Article in English | MEDLINE | ID: mdl-38791808

ABSTRACT

This study clarified the negative aspects of the self-imposed evacuation of mothers of small children seeking to avoid radiation exposure from the Fukushima Daiichi Nuclear Power Station accident on 11 March 2011. We conducted semi-structured interviews with 27 mothers, employing open-ended inquiries based on an interview guide. Our analysis of their responses using the Ka-Wakita-Jiro (KJ) method categorized the results into eight distinct groups comprising 142 labels. These categories included continued anxiety about the health effects of radiation, differences in risk perception, changes in spousal relationships, the inability to make friends and find support, living as a single parent, financial concerns, the unfamiliar feel of the area to which they evacuated, and uncertainty about the future. Despite their hardships, the mothers continued their self-imposed evacuation to avoid radioactivity. Our findings underscore that their anxieties about radiation exposure persisted even after self-imposed evacuation, leading to deteriorated relationships with key individuals who would have been involved in raising their children. These results offer valuable insights into the challenges experienced by the indirect victims of the nuclear accident, such as the mothers of small children.


Subject(s)
Fukushima Nuclear Accident , Mothers , Humans , Female , Japan , Mothers/psychology , Adult , Radiation Exposure , Child, Preschool , Infant
18.
J Gastroenterol ; 59(6): 437-441, 2024 06.
Article in English | MEDLINE | ID: mdl-38703187

ABSTRACT

Fluoroscopy-guided gastrointestinal procedures, including gastrointestinal stenting, balloon-assisted endoscopy (BAE), endoscopic retrograde cholangiopancreatography (ERCP), and endoscopic ultrasound (EUS), are essential for diagnosis and treatment in gastroenterology. Such procedures involve radiation exposure that necessitates strict safety measures to protect patients, doctors, and medical staff. The April 2020 update to Japan's Ionizing Radiation Injury Prevention Regulations for occupational exposure reduced the lens exposure dose limit to approximately one-seventh of its previous level. This change highlights the need for improved safety protocols. Without adaptation, the sustainability of fluoroscopy-based endoscopic techniques could be at risk due to the potential to exceed these new limits. This review examines the current state of medical radiation exposure in the field of gastroenterology in Japan and discusses the findings of the REX-GI study.


Subject(s)
Gastroenterology , Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , Japan , Gastroenterology/methods , Gastroenterology/standards , Occupational Exposure/prevention & control , Occupational Exposure/adverse effects , Radiation Protection/methods , Radiation Exposure/prevention & control , Radiation Exposure/adverse effects , Fluoroscopy/adverse effects , Fluoroscopy/methods , Radiation Injuries/prevention & control , Radiation Dosage
19.
J Environ Radioact ; 275: 107429, 2024 May.
Article in English | MEDLINE | ID: mdl-38614066

ABSTRACT

The potential establishment of a nuclear power plant (NPP) in the West Kalimantan is under consideration to address low electrification rates. This research assesses the demographic characteristics and population growth in the vicinity of the proposed NPP site in West Kalimantan. The investigation focuses on demographic aspects, population density, and anticipated growth during the operational phase of the reactor. The study area encompasses districts within a 25 km radius of the site. Employing a descriptive quantitative approach, this research integrates verified population data and utilizes spatial and temporal analysis. The exponential method is employed to forecast population growth throughout the operational lifespan of the reactor, to anticipate population increases in around NPP site. Reactor operation has potential radiological consequences. Results reveal that the suggested NPP site adheres to regulations concerning population density away from densely populated areas. Projected population growth is notable in specific regions, necessitating monitoring and policy attention. A gender-specific analysis highlights the higher female populations, with sensitivity to radiation exposure. These findings offer essential information for evaluating the radiological impact of the NPP on the population, so meeting NPP siting requirements. The study contributes valuable insights for decision-making regarding NPP development and safety considerations in West Kalimantan.


Subject(s)
Nuclear Power Plants , Radiation Monitoring , Humans , Radiation Exposure/statistics & numerical data
20.
Eur J Med Res ; 29(1): 222, 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38581075

ABSTRACT

BACKGROUND: Pneumonia is a major public health problem with an impact on morbidity and mortality. Its management still represents a challenge. The aim was to determine whether a new diagnostic algorithm combining lung ultrasound (LUS) and procalcitonin (PCT) improved pneumonia management regarding antibiotic use, radiation exposure, and associated costs, in critically ill pediatric patients with suspected bacterial pneumonia (BP). METHODS: Randomized, blinded, comparative effectiveness clinical trial. Children < 18y with suspected BP admitted to the PICU from September 2017 to December 2019, were included. PCT was determined at admission. Patients were randomized into the experimental group (EG) and control group (CG) if LUS or chest X-ray (CXR) were done as the first image test, respectively. Patients were classified: 1.LUS/CXR not suggestive of BP and PCT < 1 ng/mL, no antibiotics were recommended; 2.LUS/CXR suggestive of BP, regardless of the PCT value, antibiotics were recommended; 3.LUS/CXR not suggestive of BP and PCT > 1 ng/mL, antibiotics were recommended. RESULTS: 194 children were enrolled, 113 (58.2%) females, median age of 134 (IQR 39-554) days. 96 randomized into EG and 98 into CG. 1. In 75/194 patients the image test was not suggestive of BP with PCT < 1 ng/ml; 29/52 in the EG and 11/23 in the CG did not receive antibiotics. 2. In 101 patients, the image was suggestive of BP; 34/34 in the EG and 57/67 in the CG received antibiotics. Statistically significant differences between groups were observed when PCT resulted < 1 ng/ml (p = 0.01). 3. In 18 patients the image test was not suggestive of BP but PCT resulted > 1 ng/ml, all of them received antibiotics. A total of 0.035 mSv radiation/patient was eluded. A reduction of 77% CXR/patient was observed. LUS did not significantly increase costs. CONCLUSIONS: Combination of LUS and PCT showed no risk of mistreating BP, avoided radiation and did not increase costs. The algorithm could be a reliable tool for improving pneumonia management. CLINICAL TRIAL REGISTRATION: NCT04217980.


Subject(s)
Pneumonia, Bacterial , Pneumonia , Radiation Exposure , Female , Humans , Child , Male , Procalcitonin , Lung/diagnostic imaging , Pneumonia/diagnostic imaging , Pneumonia/drug therapy , Pneumonia, Bacterial/diagnostic imaging , Pneumonia, Bacterial/drug therapy , Ultrasonography/methods , Anti-Bacterial Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...