Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.642
Filter
1.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770579

ABSTRACT

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Subject(s)
Endodontics , Finite Element Analysis , Nickel , Titanium , Humans , Dental Alloys/chemistry , Dental Instruments , Endodontics/instrumentation , Endodontics/methods , Materials Testing , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Stress, Mechanical
2.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
3.
PLoS One ; 19(5): e0302551, 2024.
Article in English | MEDLINE | ID: mdl-38696475

ABSTRACT

Recently developed Nickel-Titanium (NiTi) instruments with practical changes have resulted in safer instrumentation. In addition, topographical features on the file surface are a contributing factor to clinical durability. Therefore, this study aimed to investigate both the cyclic fatigue resistance and the roughness change of MTwo and Rotate instruments (VDW, Munich, Germany). Each instrument (n = 6/each group) was scanned with an atomic force microscopy prior to and after instrumentation. In addition, cyclic fatigue testing was conducted for each instrument (n = 11/each group) with stainless-steel blocks, including 45°-60°-90° degrees of curvature milled to the instruments' size. The roughness parameters increased for both systems after instrumentation (p<0.05). Both systems presented an increased roughness following instrumentation (p<0.05). The cyclic fatigue resistance was lowest at 90° for both systems (p<0.05), whereas the Rotate files presented a higher resistance than that of the Mtwo files (p<0.05). Compared to the Mtwo files, Rotate files presented better resistance, while the resistance decreased as the curvature increased.


Subject(s)
Nickel , Surface Properties , Titanium , Titanium/chemistry , Nickel/chemistry , Microscopy, Atomic Force , Materials Testing , Root Canal Preparation/instrumentation
4.
Clin Oral Investig ; 28(6): 340, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801642

ABSTRACT

BACKGROUND: Pediatric rotary file systems were developed to solve manual file limitations. With many systems available, it may be tricky to select the most appropriate one. AIM: to assess & compare Kedo-S Square, Fanta-AF™-Baby rotary files with manual K-file concerning removed dentin amount, canal transportation, centric ability & root canal taper using CBCT in primary anterior teeth. DESIGN: Extracted Seventy-five upper primary anterior teeth with intact 2/3 root length were collected and divided into three groups based on root canal instrumentation, group-I: prepared using K-file, group-II: prepared using Kedo-S Square, and group-III: prepared using Fanta AF™ Baby file. The teeth were imaged with CBCT before & following canal instrumentation. Then, the removed dentin amount was calculated at each root-canal level. The Kruskal-Wallis test was utilized to statistically analyze study data. RESULT: The difference among the three groups was highly statistically significant at cervical & apical thirds concerning dentin thickness changes on both mesial & distal sides following canal preparation with the least removed dentin in the Kedo-S Square group(P < 0.0001). Regarding transportation & centering ability, a non-significant difference between the three groups was found. 80% of the Fanta AF™ Baby group had good-tapered preparation compared to the Kedo-S Square (72%) and K-file (40%) groups(P < 0.05). CONCLUSION: Kedo-S Square was preferable to Fanta-AFTM-Baby & manual K-files in primary root canal preparation.


Subject(s)
Cone-Beam Computed Tomography , Equipment Design , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cone-Beam Computed Tomography/methods , In Vitro Techniques , Tooth, Deciduous/diagnostic imaging , Incisor/diagnostic imaging , Dental Instruments , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/surgery
5.
PeerJ ; 12: e17418, 2024.
Article in English | MEDLINE | ID: mdl-38799069

ABSTRACT

Aim: Assess the effect of simulated clinical use and sterilization on the cyclic fatigue resistance of Race Evo and Tia Tornado Blue nickel titanium (NiTi) files. Materials and Methods: For this study, a total of sixty-four NiTi files were selected, with thirty-two files each from two different manufacturers. Files from each manufacturer were subdivided into four subgroups (n = 8) based on the test parameters. The control groups included files that were neither used nor sterilized. Files from the test groups were used to prepare the root canals of extracted mandibular premolars and then sterilized. This procedure was repeated once, twice, or thrice, depending on the test group. All files were then subjected to a cyclic fatigue test. Data was statistically analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: No significant difference was observed in the number of cycles to failure (NCF) among the subgroups for both types of files (P = 0.869 for Tia Tornado Blue, P = 0.626 for Race Evo). Tia Tornado Blue files displayed significantly higher NCF values in the control (P = 0.021), once (P = 0.027), and thrice (P = 0.031) usage groups when compared to Race Evo files. Conclusions: Repeated clinical use and sterilization for up to three cycles did not affect the cyclic fatigue resistance of Race Evo and Tia Tornado Blue files.


Subject(s)
Nickel , Sterilization , Titanium , Sterilization/methods , Humans , Equipment Failure , Materials Testing , Root Canal Preparation/instrumentation
6.
Dent Med Probl ; 61(2): 269-278, 2024.
Article in English | MEDLINE | ID: mdl-38686969

ABSTRACT

Nickel-titanium (NiTi) file separation during endodontic treatment is an undesirable event. This phenomenon needs to be understood by knowing the factors influencing fracture in endodontic files. There is a large amount of literature where these factors and their influence have been studied, increasing the knowledge about the mechanisms involved, mainly related to wire technology, file shapes and geometry, operator manipulation, the anatomy of the root canal, and the irrigation and sterilization processes. As many factors are involved, the complexity of the fracture phenomena increases and the isolated correlation of one factor with the file fracture becomes a small part of comprehending the separation phenomena. This thematic review aims to compile important reports from 2014 to 2022 on the factors influencing NiTi file separation. The information obtained was classified into wire technology, file geometry, operational aspects, irrigation and sterilization, and anatomy. For this purpose, the Scopus, Web of Science and ScienceDirect databases were consulted using a search string. Filters were applied to consolidate the final set of relevant papers covering the subject of factors influencing endodontic file separation. It was found that the fracture of NiTi files incorporates different mechanisms that operate simultaneously during the endodontic procedure and strongly affect the instrument performance. The collected information promotes good practices to prevent file separation.


Subject(s)
Nickel , Root Canal Preparation , Titanium , Humans , Root Canal Preparation/instrumentation , Equipment Failure , Equipment Design , Sterilization , Dental Instruments
7.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656634

ABSTRACT

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Subject(s)
Rheology , Humans , Dental Pulp Cavity/radiation effects , Therapeutic Irrigation/methods , Therapeutic Irrigation/instrumentation , Lasers , Root Canal Irrigants , Photoacoustic Techniques/methods , Root Canal Preparation/methods , Root Canal Preparation/instrumentation
9.
Eur Arch Paediatr Dent ; 25(2): 181-189, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38461490

ABSTRACT

PURPOSE: Pulpectomy can be used for the management of deep dentinal carious lesions in primary teeth which can be restored. Mechanical preparation of root canals can be performed using hand or NiTi rotary files. However, this may cause dentinal stress and consequently dentinal microcracks. Hence, the aim was comparative evaluation of hand and rotary file systems on dentinal microcrack formation during pulpectomy procedure in primary teeth. METHODS: 60 extracted primary molar teeth were selected comprising of 80 root canals. Simple random sampling was used to divide root canals into four groups (n = 20): Group A-Hedstrom file, Group B-Pro AF Baby Gold rotary, Group C-ProTaper Next rotary, and Group D-unprepared group. Assessment was conducted on presence or absence of microcracks using Chi square test (p < 0.05). RESULTS: The total number of microcracks in Group A: one (5%), Group B: four (20%), Group C: nine (45%) and Group D: zero (0%) which was statistically significant (p = 0.002). At cervical third, the number of microcracks seen with Group A: one (5%), Group B: zero (0%), Group C: five (25%) and Group D: zero (0%) (p = 0.005). At the middle third, the number of microcracks seen in Group A: zero (0%), Group B: four (20%), Group C: four (20%) and Group D: zero (0%) (p = 0.029). CONCLUSION: The study concluded that dentinal microcracks are formed with both hand and rotary file systems in primary teeth. ProTaper Next showed significantly higher number of microcracks, followed by ProAF Baby Gold and H files.


Subject(s)
Dentin , Pulpectomy , Root Canal Preparation , Tooth, Deciduous , Humans , Tooth, Deciduous/surgery , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Pulpectomy/methods , Dentin/injuries , In Vitro Techniques , Dental Instruments/adverse effects , Molar/surgery , Equipment Design , Dental Pulp Cavity/surgery , Nickel
10.
Eur Arch Paediatr Dent ; 25(2): 227-235, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38472709

ABSTRACT

PURPOSE: To evaluate the volumetric changes of two recently introduced paediatric rotary file systems in comparison with conventional hand file systems in primary maxillary canines using an ultra-high-resolution nano-computed tomography. METHODS: This in vitro study was performed in extracted primary maxillary canines based on certain inclusion and exclusion criteria. Samples were prepared, and working length was determined after the pre-operative scan using a high-resolution nano-CT device (SkyScan 2214, Bruker, Kontich, Belgium). A single well-experienced paediatric dentist prepared the canals using three file systems: Kedo-S plus, Kedo-SG blue and hand K-files. All samples were subjected to post-operative scans performed similar to pre-operative scans. Image reconstruction was performed with NRecon software for 3D volumetric visualisation and analysis of the root canals. RESULTS: Kedo-SG blue file systems had the highest mean difference in the canal volume (4.05%). Hand K-files had the least difference at (3.71%) of canal volume. Kedo-S plus file system had a moderate mean canal volume difference (3.82%) which is closer to hand K-files. Intergroup comparison between the three groups showed that the mean difference in canal volume was statistically significant between all three file systems (p = 0.000). CONCLUSION: Within the limitations of the current study, rotary file systems produced a significant enlargement of canals as compared to hand files. Kedo-SG blue created a uniform preparation of the canal cervico-apically. Kedo-S plus files were prepared more coronally with minimal preparation apically as close to the preparation of hand files. TRIAL REGISTRATION: Trial registration number: IHEC/SDC/PEDO-2103/22/651, Date of registration: 2022.


Subject(s)
Cuspid , Dental Pulp Cavity , Maxilla , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cuspid/diagnostic imaging , Cuspid/anatomy & histology , Tooth, Deciduous/diagnostic imaging , Tooth, Deciduous/anatomy & histology , Maxilla/diagnostic imaging , In Vitro Techniques , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Instruments , Equipment Design
11.
J Dent ; 144: 104928, 2024 May.
Article in English | MEDLINE | ID: mdl-38484867

ABSTRACT

OBJECTIVES: Synthesise evidence on post-endodontic pain (PEP) in adult teeth undergoing primary root canal treatment with the adjunctive use of laser-activated irrigation (LAI) as compared with conventional needle irrigation (CNI) during the first post-operative week. DATA: An electronic search was performed; no language constraints or restriction on the year of publication were applied. SOURCES: Medline, Scopus, Cochrane and PubMed on 04 June 2023 STUDY SELECTION: Randomised clinical trials (RaCTs) that evaluated PEP after LAI of endodontic irrgants were included. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were used. PEP was analysed at various time intervals until 1 week after treatment, related to the type of LAI used and the need for analgesia. REULTS: Of the 793 articles identified through the electronic database search, 6 RaCTs were included. Qualitative review was favoured over meta-analysis due to substantial methodological heterogeneity between studies. Five studies were at high risk for bias determined by the Cochrane Risk-of-Bias 2 tool. Diode LAI demonstrated superior efficacy to needle irrigation in reducing pain 6-48 h post-treatment. The impact of LAI by photon-induced photoacoustic streaming (PIPS) was unclear and no difference was observed between PIPS and needle irrigation. However, PIPS mitigated PEP better than manual dynamic activation, sonic and ultrasonic activation. There was no difference in analgesia intake between LAI and needle irrigation groups. CONCLUSIONS: LAI may help reduce PEP in the first 48 h. Methodological standardisation of future RaCTs on LAI would be beneficial in allowing a more accurate review with the possibility of quantitative synthesis. CLINICAL SIGNIFICANCE: This unique synthesis used stringent criteria to reduce confounding factors and provided valuable evidence regarding PEP with different types of LAI. It helps clinicians choose an appropriate LAI technique as compared with CNI and predicts a time frame for reducing PEP.


Subject(s)
Pain, Postoperative , Root Canal Therapy , Therapeutic Irrigation , Humans , Pain, Postoperative/prevention & control , Pain, Postoperative/etiology , Therapeutic Irrigation/methods , Root Canal Therapy/methods , Root Canal Irrigants/therapeutic use , Root Canal Preparation/methods , Root Canal Preparation/instrumentation , Randomized Controlled Trials as Topic , Lasers , Adult , Pain Measurement
12.
J Endod ; 50(5): 619-626, 2024 May.
Article in English | MEDLINE | ID: mdl-38311114

ABSTRACT

INTRODUCTION: Determination of the glide path is recommended before using rotary instruments. This study aimed to evaluate the dynamic cyclic fatigue resistance of new and used glider rotary instruments in up to 6 root canals. METHODS: Seventy-two TruNatomy Glider files were used for the preparation of root canals of extracted lower molars, which were then submitted to the dynamic cyclic fatigue test carried out in a curved metallic artificial canal. The instruments were divided into 4 groups (n = 18): Control group, new instruments without any use in the root canal; Group 2U, instruments used in 2 mesial canals; Group 4U, instruments used in 4 mesial canals; Group 6U, instruments used in 6 mesial canals. The time to failure (TF) of the instrument was recorded, and the number of cycles to failure (NCF) was calculated. The data were submitted to 1-way analysis of variance and to the Games-Howell test for multiple comparisons, adopting a significance level of 5%. RESULTS: TF and NCF were significantly affected by the number of file uses. The Games-Howell test revealed that TF and NCF were significantly greater in the control group than in Group 4U. In Group 2U, TF and NCF were intermediate and not significantly different from the control group. Group 6U had significantly lower TF and NCF than all other groups. CONCLUSION: The TruNatomy Glider can be used as a glide path for up to 2 mesial canals of mandibular molars, whereas its use on 4 or 6 root canals is not suggested.


Subject(s)
Equipment Failure , Root Canal Preparation , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Humans , Dental Instruments , Equipment Design , In Vitro Techniques , Molar , Dental Stress Analysis , Dental Pulp Cavity , Materials Testing
13.
J Endod ; 50(5): 644-650.e1, 2024 May.
Article in English | MEDLINE | ID: mdl-38382735

ABSTRACT

INTRODUCTION: This study aimed to evaluate the removal of a biofilm-mimicking hydrogel from isthmus structures in a simulated complex root canal system consisting of 2 curved root canals by Laser-activated irrigation (LAI, AdvErl Evo, Morita) and mechanical activation techniques. METHODS: A 3D-printed root canal model with 2 parallel root canals (60°-curvature, radius 5 mm, dimension 25/.06) with a total length of 20 mm connected via isthmuses (2.5 × 0.4 × 0.2 mm) at 5 mm and 8 mm from the apical endpoint and with lateral canals (diameter 0.2 mm) in all directions at 2, 5, and 8 mm from the apex was filled with a colored biofilm-mimicking hydrogel. Irrigation protocols under continuous irrigation with distilled water (3 × 20s per root canal; 3 ml/20s; n = 20) included conventional needle irrigation (=NI); manual agitation (=MA, gutta-percha point 25/.06); EndoActivator (=SAI-EA, 25/.04); EDDY (=SAI-E, 25/.04); ultrasonically-activated irrigation (=UAI) and LAI (Er:YAG-laser; P400FL tip at canal entrance; 25pps, 50 mJ, 300µs). Removal of the hydrogel was determined as a percentage via standardized photos through a microscope. Statistical analysis was performed using Kruskal-Wallis and Conover tests (P = .05). RESULTS: Laser-activated irrigation (LAI) was associated with the greatest removal of hydrogel from the entire root canal system (P < .05), followed by SAI-E. No significant differences were reported for the coronal isthmus between LAI, SAI-E, NI, and MA (P > .05), but inferior results for SAI-EA and UAI (P < .05). In the apical isthmus, all techniques outperformed UAI (P < .05), with LAI, SAI-E, and NI showing the best results (P < .05). CONCLUSIONS: Laser-activated irrigation (LAI) was superior to other irrigation techniques in the entire root canal system. SAI-E and NI performed comparable to LAI in the isthmuses.


Subject(s)
Dental Pulp Cavity , Root Canal Irrigants , Root Canal Preparation , Therapeutic Irrigation , Therapeutic Irrigation/methods , Therapeutic Irrigation/instrumentation , Root Canal Preparation/methods , Root Canal Preparation/instrumentation , Root Canal Irrigants/administration & dosage , Humans , Biofilms , Printing, Three-Dimensional
14.
J Endod ; 50(5): 651-658, 2024 May.
Article in English | MEDLINE | ID: mdl-38387796

ABSTRACT

INTRODUCTION: This study assessed the effect of intentional foraminal enlargement on the foramen and the apical root canal morphology. METHOD: Sixty mesial roots of mandibular molars were scanned by micro-computed tomography. Their apical foramina were photographed with a stereomicroscope before and after preparation. Three groups were formed (n = 20) according to the working length (WL). G-1: foramen - 1 mm; G0: foramen; and G+1: foramen + 1 mm. Each group originated 2 subgroups (n = 10): G-1: Buchanan's patency (size 10 K-type file) and foraminal debridement (sizes 20, 25 and 30 K-type files); G0 and G+1: rotary foraminal enlargement (ProDesign S size 25/.08) or reciprocating foraminal enlargement (R25). The area, perimeter, transportation, and noninstrumented walls of the foramen were evaluated. The root canal transportation and the centering index of preparation at 1, 3 and 5 mm from the foramen were also assessed. Data were compared statistically (α = 5%). RESULTS: The instruments used at the foramen and 1 mm beyond promoted foraminal enlargement and transportation. Regarding NIW, there was no difference between mechanized foraminal enlargements performed at the foramen or 1 mm beyond, similar to the manual foraminal debridement group (P > .05). There was no difference in transportation and centralization at 1-, 3-, and 5-mm apical levels, regardless of the instrumentation systems. CONCLUSION: Mechanical preparation at the foramen, or 1 mm beyond, resulted in foraminal enlargement, transportation and were not able to touch all root canal walls that delimit the foramen.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Preparation , Tooth Apex , X-Ray Microtomography , Humans , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Molar/diagnostic imaging , Tooth Apex/diagnostic imaging , Tooth Apex/anatomy & histology , Mandible/diagnostic imaging , Mandible/anatomy & histology
15.
Int Endod J ; 57(6): 700-712, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38404175

ABSTRACT

AIM: To evaluate the influence of different preparation tapers on the reduction in planktonic bacteria and biofilms of Enterococcus faecalis and Candida albicans in the apical third (4 mm) of the mesial roots of mandibular molars, correlating decontamination with canal shape. METHODOLOGY: After microtomography analysis for morphological standardization of the canals, 48 mandibular molar roots, each containing two canals (96 canals), were contaminated with E. faecalis and C. albicans and divided into four groups (n = 11) for canal instrumentation using ProDesign Logic 2 files with different tapers G (.03): # 25.03; G (.04): # 25.04; G (.05): # 25.05; and G (.06): # 25.06 and irrigation with 2.5% sodium hypochlorite. Four roots were examined under a scanning electron microscope (SEM) to qualitatively assess biofilm formation. Eight roots were used as the negative control group (samples were not contaminated). Bacteriological samples were taken exclusively from the apical third of the roots before and after chemical-mechanical preparation and bacterial counts were determined (CFU/mL). The final micro-CT scan was used to quantify the volume variation and unprepared canal area in the apical third. Statistical analysis was performed using the Kruskal-Wallis, Student-Newman-Keuls and Wilcoxon tests for analysis of microbiological data. anova and the Tukey or Games-Howell test were used for analysis of micro-CT data and Spearman's test for correlations (α = 5%). RESULTS: All groups showed a significant reduction in bacteria (p < .05), with no statistically significant difference between groups. There was no significant difference in per cent volume increase between groups. The unprepared area (Δ%) was affected by the file used (p = .026) and was significantly lower for G (.06) compared to G (.03). There was no statistically significant correlation among bacterial reduction, volume and unprepared area (p > .05). CONCLUSION: The different preparation tapers influenced root canal shaping in the apical third but did not improve decontamination in this region.


Subject(s)
Biofilms , Candida albicans , Dental Pulp Cavity , Enterococcus faecalis , Root Canal Preparation , X-Ray Microtomography , X-Ray Microtomography/methods , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Candida albicans/isolation & purification , Candida albicans/physiology , Dental Pulp Cavity/microbiology , Dental Pulp Cavity/diagnostic imaging , Sodium Hypochlorite/therapeutic use , Sodium Hypochlorite/pharmacology , Microscopy, Electron, Scanning , Molar/microbiology , Plankton , Root Canal Irrigants/administration & dosage , Root Canal Irrigants/therapeutic use , In Vitro Techniques , Tooth Apex/microbiology , Tooth Apex/diagnostic imaging
16.
J Endod ; 50(5): 612-618, 2024 May.
Article in English | MEDLINE | ID: mdl-38278319

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the effectiveness of the XP-endo Finisher R (XPFR; FKG Dentaire, La Chaux-de-Fonds, Switzerland) or the Flatsonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, SP, Brazil) in removing remaining filling material after the retreatment of flattened root canals using micro-computed tomographic imaging. METHODS: Twenty-four flattened distal root canals of mandibular molars with a buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with Reciproc Blue (RB) R40 (VDW GmbH, Munich, Germany) and filled using the Tagger hybrid technique. All canals were retreated with RB R40, and apical enlargement was performed with RB R50 (VDW GmbH). The specimens were randomly distributed into 2 groups: XPFR or Flatsonic (n = 12). The percentage of remaining filling material after retreatment and centralization ability was evaluated. Data were submitted to Mann-Whitney, Wilcoxon, and unpaired t tests (α = 5%). RESULTS: Greater capacity to remove remaining filling material in the entire canal and the cervical and middle thirds was observed for the Flatsonic compared with the XPFR (P < .05). However, both supplementary cleaning techniques showed a similar percentage of residual filling material in the apical third (P > .05). No difference was observed in the centralization ability between the techniques (P > .05). CONCLUSIONS: The Flatsonic promotes greater removal of remaining filling material than the XPFR in the retreatment of flattened root canals. However, both supplementary cleaning approaches were similar in the apical third. The XPFR and Flatsonic were able to maintain root canal centralization.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Preparation , X-Ray Microtomography , X-Ray Microtomography/methods , Humans , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Root Canal Filling Materials/therapeutic use , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Molar/diagnostic imaging , Retreatment , Root Canal Obturation/methods , Ultrasonic Therapy/methods
17.
PeerJ ; 11: e15830, 2023.
Article in English | MEDLINE | ID: mdl-37576504

ABSTRACT

Background: This study compared the ability of thermally treated files in shaping simulated canals with double curvature. Fifty-six canals were enlarged to a final size of 25 with ProTaper Next (PTN) or ZenFlex (ZF). Materials: Half of the samples were shaped with cooled files (n = 14 each). The amount of removed resin was measured and canal deviation was determined at eight levels. Shaping time and maximum shaping torque values were also recorded. Data were statistically analyzed using analysis of variance and LSD, Kruskal-Wallis, and chi-square tests at a 0.05 significance level. Results: Compared to PTN and cooled PTN, ZF and cooled ZF required lesser time to shape the canals. The maximum torques were found comparable between the groups. All the groups generated negligible deviations at every canal level evaluated and maintained the canal geometry. Although not significant, the cooled PTN and ZF files exhibited lesser canal deviations than their counterparts. Conclusion: All groups demonstrated similar shaping ability whilst maintaining the original curvature of the canal in simulated canals with double curvature. However, ZF groups were able to shape the canals faster than PTN groups. There was a trend that cooled files made lesser canal deviations compared to their counterparts.


Subject(s)
Cold Temperature , Dental Equipment , Root Canal Preparation , Equipment Design , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Root Canal Preparation/standards , Torque , Analysis of Variance , Dental Equipment/standards
18.
Rev. Asoc. Odontol. Argent ; 111(2): 1110871, mayo-ago. 2023. ilus
Article in Spanish | LILACS | ID: biblio-1537147

ABSTRACT

El objetivo de esta comunicación es describir y analizar el sistema BlueShaper para la preparación quirúrgica mecaniza- da de los conductos radiculares. El sistema dispone de un set básico de 4 limas: Z1, Z2, Z3 y Z4, con un D0 de 0,14 mm, 0,17 mm, 0,19 mm y 0,25 mm respectivamente y conicidad variable que oscila entre el 2 y 10 %. La lima Z1 posee una aleación Pink, que le confiere mayor resistencia a la torsión y una gran capacidad de corte. Las limas Z2, Z3 y Z4 presentan una aleación Blue que aumenta la resistencia a la fatiga cíclica e incrementa su flexibilidad. Para conductos radiculares más amplios se incluyen, además, las limas Z5, Z6 y Z7. La empresa comer- cializa conos de gutapercha BlueShaper que se corresponden con las limas Z3, Z4, Z5, Z6 y Z7. El sistema de limas mul- tialeación Blue Shaper podría considerarse como un nuevo aporte clínico para la preparación mecánica de los conductos radiculares (AU)


The aim of this communication was to describe and analyze the BlueShaper system for the mechanized surgical preparation of root canals. The system has a basic set of 4 files: Z1, Z2, Z3 and Z4, with 0.14 mm, 0.17 mm, 0.19 mm and 0.25 mm DO respective- ly, and variable conicity ranging between 2 and 10 %. Z1 file has a Pink alloy, which gives it greater resistance to torsion and great cutting capacity. The Z2, Z3 and Z4 files feature a Blue alloy that increases resistance to cyclic fatigue and increases their flexibility. For larger root canals, the Z5, Z6 and Z7 files are also included. The company supplies specific BlueShaper ́s gutta-percha cones for Z3, Z4, Z5, Z6 and Z7 files. The BlueShaper multialloy file system could be consid- ered as a new clinical contribution for the mechanical prepa- ration of root canals (AU)


Subject(s)
Root Canal Preparation/instrumentation , Dental Alloys , Dental Instruments , Rotation , Thermodynamics , Torsion, Mechanical
19.
Eur Rev Med Pharmacol Sci ; 27(6): 2241-2249, 2023 03.
Article in English | MEDLINE | ID: mdl-37013742

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate and compare the effect of different laser prototypes [Er, Cr: YSGG laser (ECYL), potassium titanyl phosphate laser (KTP), and Femtosecond laser (FSL)]and curcumin photosensitizer (CP) activated by Photodynamic therapy (PDT) on the bond strength of Pre-fabricated fiber reinforced composite (PFRC) post-bonded to radicular dentin. MATERIALS AND METHODS: A total of fifty mandibular single-rooted closed apex teeth were extracted carefully, assembled, and decoronated up to the cementoenamel junction. The working length of all specimens was determined by using a 10 K patency file and later, were cleaned and shaped with Protaper NiTi system using the crown down approach, dried, and obturated with gutta-percha using an AH Plus sealer. Post space was prepared by guiding peeso-reamer. Based on the method of disinfection, the samples were allocated to five groups (n=10) at random: samples in group 1: curcumin photosensitizer (CP) activated by PDT, samples in group 2 disinfected using 5.25% NaOCl+17% EDTA, samples in group 3 disinfected using 5.25% NaOCl+17% EDTA+FSL, specimens in group 4 sterilized using 5.25% NaOCl+17% EDTA+KTP and samples in group 5 cleaned with 5.25% NaOCl+17% EDTA+ECYL. The fiber post was cemented via self-etch resin cement into the post space. All specimens with posts were dissected perpendicularly into apical, middle, and coronal dentin and subjected to the universal testing machine for push-out bond strength (PBS) testing. Statistical analysis was performed using a One-Way analysis of variance and Post Hoc Tukey multiple comparison tests. RESULTS: The highest PBS was corroborated when the radicular canal was disinfected with 5.25% NaOCl +17% EDTA+ ECYL at all three root levels (coronal, middle, and apical) and the lowest was adjudicated by decontamination with CP activated by PDT at all inspected root levels. Intergroup comparison presented that specimens in group 2: 5.25% NaOCl+17% EDTA (control) and group 4: 5.25% NaOCl+17% EDTA+KTP revealed comparable PBS outcome to group 5 (p>0.05) while samples in group 3 revealed the equivalent PBS values to group 1 (p<0.05) at all three root levels. CONCLUSIONS: Er, Cr: YSGG laser and potassium titanyl phosphate laser when used in combination with the conventional canal disinfection 5.25% NaOCl and 17% EDTA demonstrated the highest push-out bond strength values at coronal, middle, and apical levels of the root.


Subject(s)
Curcumin , Disinfection , Lasers, Solid-State , Photochemotherapy , Root Canal Preparation , Dental Pulp Cavity , Dentin , Disinfection/instrumentation , Disinfection/methods , Edetic Acid , Lasers, Solid-State/therapeutic use , Materials Testing , Photochemotherapy/methods , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Tooth Apex/drug effects , Tooth Apex/radiation effects , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...