Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.242
Filter
1.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770579

ABSTRACT

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Subject(s)
Endodontics , Finite Element Analysis , Nickel , Titanium , Humans , Dental Alloys/chemistry , Dental Instruments , Endodontics/instrumentation , Endodontics/methods , Materials Testing , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Stress, Mechanical
2.
Braz Dent J ; 35: e245883, 2024.
Article in English | MEDLINE | ID: mdl-38775594

ABSTRACT

This study assessed the intratubular antibacterial ability of different activated irrigations after chemical mechanical preparation. Seventy-two palatal root canals of upper molars were infected with Enterococcus faecalis for 4 weeks, and then initial bacterial collection from the main root canal was performed. The root canals were prepared by using a WaveOne Gold large (45/.05) and distributed into 6 groups according to the activation of the final irrigation: ultrasonic activation (UA), XP-Endo Finisher (25/.00), XP Clean (25/.02), EasyClean (25/.04) in reciprocating motion and continuous rotary motion (ECRot), and conventional irrigation. After final irrigation, another bacterial collection from the main root canal was performed, and the root was sectioned transversely in three-thirds and stained for analysis by confocal laser microscopy. Intratubular bacteria were collected through dentin powder and plated for bacterial viability analysis. Intergroup and intragroup comparisons were performed by using analysis of variance and repeated measures analysis of variance, respectively, both at 5% significance. ECRot had higher antibacterial ability than UA (p<0.05), and both were superior to the other groups (p<0.05) in both methodologies. It can be concluded that activation of final irrigation enhances the disinfection of the root canal system, and activators have different efficacies.


Subject(s)
Anti-Bacterial Agents , Enterococcus faecalis , Root Canal Irrigants , Root Canal Preparation , Humans , Root Canal Irrigants/pharmacology , Root Canal Preparation/methods , Anti-Bacterial Agents/pharmacology , Dental Pulp Cavity/microbiology , Microscopy, Confocal , Therapeutic Irrigation/methods , Molar
3.
BMC Oral Health ; 24(1): 595, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778321

ABSTRACT

INTRODUCTION: Transforming Growth Factor-Beta 1 (TGF-ß1) plays a crucial role in the success of Regenerative Endodontic Procedures (REPs) as they directly impact the proliferation and differentiation of stem cells. TGF-ß1 is released by conditioning of the dentin matrix using 17% EDTA. EDTA was found to have deleterious effects on dentin especially in immature teeth with fragile dentin walls. Decreasing the irrigation time was reported to decrease these effects. Accordingly, enhancement and activation of the EDTA solution to maintain its efficiency in TGF-ß1 release from dentin and thus compensating the reduction in irrigation time was employed. EDTA solution was enhanced by adding Nanobubble (NB) water which contains oxygen filled cavities less than 200 nm in diameter. Additionally, EDTA was activated with XP-endo Finisher rotary file. The aim of this study was to assess the impact of NB enhancement and/or XP-endo Finisher activation of the EDTA solution on the TGF-ß1 release from dentin. METHODS: Fifty standardized root segments with open apex were allocated to two main groups according to whether EDTA was enhanced with NB water or not, and within each group whether XP-endo Finisher activation was used or not in addition to a Negative Control group. The concentration of the released TGF-ß1 in the root canal was measured using enzyme-linked immunosorbent assay (ELISA). The statistical analysis was done using the Shapiro- Wilk, Kolmogorov Smirnov, ANOVA and Post-hoc Tukey tests. RESULTS: All groups released a considerable amount of TGF-ß1 with the highest values in the EDTA/NB/XP group, followed by EDTA/NB, EDTA/DW/XP, EDTA/DW and Negative Control groups respectively. CONCLUSIONS: The results of this study suggest that NBs can promote the success of REPs since it revealed a significant increase in the TGF-ß1 release following its use in the enhancement of the EDTA solution. A comparable effect was obtained by XP-endo finisher activation of the EDTA solution. The combined use of NBs and XP-endo Finisher can be a promising addition in REPs. Accordingly, Enhancement and activation of the EDTA solution may compensate decreasing the EDTA irrigation time attempted to avoid the deleterious effect of EDTA on dentin.


Subject(s)
Dentin , Edetic Acid , Regenerative Endodontics , Transforming Growth Factor beta1 , Edetic Acid/pharmacology , Transforming Growth Factor beta1/metabolism , Humans , Dentin/drug effects , Regenerative Endodontics/methods , Root Canal Irrigants/pharmacology , Water , Root Canal Preparation/methods , Enzyme-Linked Immunosorbent Assay
4.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
5.
Clin Oral Investig ; 28(6): 340, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801642

ABSTRACT

BACKGROUND: Pediatric rotary file systems were developed to solve manual file limitations. With many systems available, it may be tricky to select the most appropriate one. AIM: to assess & compare Kedo-S Square, Fanta-AF™-Baby rotary files with manual K-file concerning removed dentin amount, canal transportation, centric ability & root canal taper using CBCT in primary anterior teeth. DESIGN: Extracted Seventy-five upper primary anterior teeth with intact 2/3 root length were collected and divided into three groups based on root canal instrumentation, group-I: prepared using K-file, group-II: prepared using Kedo-S Square, and group-III: prepared using Fanta AF™ Baby file. The teeth were imaged with CBCT before & following canal instrumentation. Then, the removed dentin amount was calculated at each root-canal level. The Kruskal-Wallis test was utilized to statistically analyze study data. RESULT: The difference among the three groups was highly statistically significant at cervical & apical thirds concerning dentin thickness changes on both mesial & distal sides following canal preparation with the least removed dentin in the Kedo-S Square group(P < 0.0001). Regarding transportation & centering ability, a non-significant difference between the three groups was found. 80% of the Fanta AF™ Baby group had good-tapered preparation compared to the Kedo-S Square (72%) and K-file (40%) groups(P < 0.05). CONCLUSION: Kedo-S Square was preferable to Fanta-AFTM-Baby & manual K-files in primary root canal preparation.


Subject(s)
Cone-Beam Computed Tomography , Equipment Design , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cone-Beam Computed Tomography/methods , In Vitro Techniques , Tooth, Deciduous/diagnostic imaging , Incisor/diagnostic imaging , Dental Instruments , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/surgery
6.
J Clin Pediatr Dent ; 48(3): 156-165, 2024 May.
Article in English | MEDLINE | ID: mdl-38755994

ABSTRACT

There is currently a lack of research on the application of newly developed irrigation techniques in root canal treatment of primary teeth. This study aimed to evaluate the effects of various irrigation activation techniques on two key parameters: apical debris extrusion (ADE) and dentinal tubule penetration depth (DTPD) of the root canal filling material. A total of 96 primary mandibular second molars were randomly divided into 4 groups: Group 1-Conventional Needle Irrigation (CNI), Group 2-XP-Endo Finisher (XPF), Group 3-EndoActivator (EA), and Group 4-Passive Ultrasonic Irrigation (PUI). In all groups, the One Reci single-file system was used for root canal preparation. For ADE measurement, each group was rinsed with distilled water. For DTPD assessment, sodium hypochlorite (NaOCl) was applied. ADE quantification was performed by collecting debris in pre-weighed Eppendorf tubes. A combination of fluorescent dye and root canal filling material (DiaPex Plus) was used for root canal filling. In order to examine DTPD, horizontal cross-sections of the coronal and apical regions of the teeth were taken with a thickness of 1 mm. The maximum and mean DTPD was examined by confocal laser scanning microscopy. Data were analyzed using the Kruskal-Wallis, One-way ANOVA, and Mann-Whitney U tests (p = 0.05). As a result, PUI had the highest mean ADE and CNI had the lowest mean ADE, while CNI had the highest mean DTPD in both the coronal and apical regions, whereas PUI had the lowest mean DTPD in the coronal region, and EA had the lowest mean DTPD in the apical region. There were no statistically significant differences in DTPD and ADE among the four groups. Comparing intragroup maximum DTPD across all groups, it was significantly higher in the coronal region than in the apical region (p < 0.05). ADE and DTPD of root canal filling materials in primary teeth did not differ significantly among CNI, XPF, EA and PUI irrigation activation techniques.


Subject(s)
Molar , Root Canal Irrigants , Root Canal Preparation , Therapeutic Irrigation , Tooth, Deciduous , Humans , Therapeutic Irrigation/methods , Root Canal Irrigants/therapeutic use , Root Canal Preparation/methods , Sodium Hypochlorite/therapeutic use , Microscopy, Confocal , Root Canal Filling Materials/therapeutic use , Dental Pulp Cavity/drug effects , Needles
7.
BMC Oral Health ; 24(1): 612, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802852

ABSTRACT

BACKGROUND: Growth factors embedded in the extracellular matrix of the dentin play an important role in the migration, proliferation, and differentiation of dental pulp stem cells in regenerative endodontics. In regenerative endodontic treatments, the type of irrigation solution used is crucial for the release of growth factors (GFs) from the dentin matrix. This study evaluated the effectiveness of different irrigant activation techniques (IAT) using two different chelating agents, 17% ethylenediaminetetraacetic acid (EDTA) and 9% etidronic acid (HEDP), in terms of their GF release. METHODS: Seventy-two mandibular premolar teeth were prepared to simulate an open apex. The root fragments were irrigated with 20 ml of 1.5% sodium hypochlorite and 20 ml of saline solution. Eight root fragments were randomly separated for the control group, and the remaining 64 fragments were randomly separated into eight groups based on two different chelating agents (17% EDTA and 9% HEDP) and four different IAT ((conventional needle irrigation (CNI), passive ultrasonic irrigation (PUI), sonic activation with EDDY, and XP-endo Finisher (XPF)). TGF-ß1, VEGF-A, BMP-7 and IGF-1 release levels were determined using an ELISA, and statistical analysis was performed using the Kolmogorov-Smirnov test, ANOVA, and the Tukey test (p < .05). RESULTS: Compared to the control group, the experimental groups showed significantly higher GF release when using EDTA or HEDP. Among the activation groups, the EDDY group triggered the highest GF release, and the CNI group triggered the lowest. CONCLUSIONS: IAT with EDTA and HEDP can increase GF release, with EDDY being the most effective IAT method. Using chelating agents with IAT may be beneficial in regenerative endodontic treatments.


Subject(s)
Chelating Agents , Dentin , Edetic Acid , Etidronic Acid , Root Canal Irrigants , Humans , Root Canal Irrigants/pharmacology , Dentin/drug effects , Etidronic Acid/pharmacology , Chelating Agents/pharmacology , In Vitro Techniques , Intercellular Signaling Peptides and Proteins , Regenerative Endodontics/methods , Bicuspid , Root Canal Preparation/methods
8.
BMC Oral Health ; 24(1): 476, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38643094

ABSTRACT

OBJECTIVES: This study aimed to design a modified passive-deflation sealer injection needle and investigate its ability to improve obturation quality of single-cone technique through assessing the distribution of voids in root canals using micro-computed tomography (micro-CT). MATERIALS AND METHODS: Forty-eight mandibular incisors were divided into eight groups (n = 6), according to the taper of root canal preparation (0.06 or 0.04), the needle used for sealer injection (modified or commercial iRoot SP injection needle), and the obturation method (iRoot SP sealer-only or single-cone obturation). After obturation, each specimen was scanned by micro-CT. The volumetric percentage and distribution of all voids were first analyzed and compared among groups, then the open and closed voids were separately analyzed and compared among single-cone obturation groups. RESULTS: Compared to commercial needle groups, modified needle groups showed much less voids, especially in the apical root canal part (P < 0.05). Besides, the modified needle groups produced much less open voids than commercial needle groups despite the root canal taper (P < 0.05). CONCLUSIONS: The modified passive deflation sealer injection needle could effectively improve the quality of single-cone obturation through reducing intra-canal voids, especially open voids throughout the root canal, thus might possibly be developed as an effective intra-canal sealer delivering instrument.


Subject(s)
Dental Pulp Cavity , Root Canal Filling Materials , Silicates , Humans , X-Ray Microtomography , Dental Pulp Cavity/diagnostic imaging , Root Canal Obturation/methods , Root Canal Preparation/methods , Gutta-Percha
9.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656634

ABSTRACT

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Subject(s)
Rheology , Humans , Dental Pulp Cavity/radiation effects , Therapeutic Irrigation/methods , Therapeutic Irrigation/instrumentation , Lasers , Root Canal Irrigants , Photoacoustic Techniques/methods , Root Canal Preparation/methods , Root Canal Preparation/instrumentation
10.
PLoS One ; 19(4): e0299896, 2024.
Article in English | MEDLINE | ID: mdl-38568900

ABSTRACT

The objective was to evaluate the effect of glide path and coronal flaring on the dentin volume removal and percentage of touched walls in curved canals using two heat-treated rotary files. The mesiobuccal canal of forty-eight, randomly selected, extracted mandibular molars was divided into two groups of 24 each, according to the type of instrument used (RACE EVO and EdgeSequel rotary files). Each group was further divided into three subgroups; Group (A): Control using one file shaped to 04/30, Group (B) with a glide path (EdgeGlidePath (EGP)), and Group (C): with a glide path and coronal flaring (EGP and EdgeTaper Platinum (ETP) SX file respectively). The root canals were then instrumented using the assigned instruments. The assessment was carried out using micro-CT. The comparison of the mean values of the tested groups about dentin volume removal and percentage of untouched walls did not reach statistical significance (p<0.05). Glide path and coronal flaring had an insignificant effect on the dentin volume removal and percentage of untouched walls in curved canals.


Subject(s)
Hot Temperature , Nickel , Root Canal Preparation , X-Ray Microtomography/methods , Root Canal Preparation/methods , Alloys , Titanium , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/surgery , Equipment Design
12.
Shanghai Kou Qiang Yi Xue ; 33(1): 54-58, 2024 Feb.
Article in Chinese | MEDLINE | ID: mdl-38583025

ABSTRACT

PURPOSE: To compare the forming ability of four kinds of nickel-titanium instrument preparation resin for simulated curved root canal. METHODS: A total of 40 single bend resin simulated root canals were randomly divided into 4 groups with 10 in each group. Four kinds of nickel-titanium instruments (ProTaper, HyFlex EDM, WaveOne Gold and Reciproc Blue) were used for root canal preparation, and divided into group A, group B, group C and group D. The preparation time of the four groups was compared, the root canal images before and after preparation were analyzed by computer image analysis software, and the changes of the preparation time, curvature and curvature radius of the four groups were recorded. With the root tip as the center of the circle, the radius of 1-10 mm was selected as concentric circle arcs. The detection points were overlapping root canal intersection points. The resin removal amount and center positioning force of the inner and outer walls of the root canal at different detection points were recorded. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: The root canal preparation time in group A was significant longer than that in group B, C and D(P<0.05), but there was no significant difference in the curvature and curvature radius of the root canal among the four groups (P>0.05). The removal amount of resin from the root canal wall in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 8, 9 and 10 mm, respectively. The removal amount of resin from the outer wall of the root canal in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 7, 9 and 10 mm, respectively. The root tip offset of group A from the detection point to the apical hole of 1, 2, 3, 4, 6, 7, 8, 9 and 10 mm was significant greater than that of group B, C and D(P<0.05). CONCLUSIONS: Among the four instruments, ProTaper has the largest apical deviation, HyFlex EDM, WaveOne Gold and Reciproc Blue have better ability of root canal forming.


Subject(s)
Dental Pulp Cavity , Titanium , Nickel , Dental Instruments , Root Canal Preparation/methods , Equipment Design
13.
Am J Dent ; 37(1): 39-46, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38458982

ABSTRACT

PURPOSE: To investigate the differences between irrigant propagation and temperature changes using laser-activated irrigation (LAI) at different settings in an artificial root canal model. METHODS: Using an artificial resin root canal model, irrigant activation was achieved in 19 experimental groups with eight samples each. A 9,300 nm CO2 laser, two diode lasers with different settings (wavelengths 455, 808, 970, and 980 nm) were compared to 2,940 nm Er:YAG laser and traditional needle irrigation. Er:YAG and CO2 laser were activated in the pulpal chamber only, while diode lasers and needles were inserted into the main root canal. Lasers were activated for 5x 20 seconds resulting in 100 seconds of activation or rinsing for each sample. After each activation of 20 seconds, a photo was taken of the side canals and the propagation of the dye was measured with a digital measuring tool after calibration. Further, the temperature of the irrigant was reported after activation of 20 seconds and repeated 5 times. Data were checked for normality and statistically compared. RESULTS: All lasers increased the irrigant propagation compared to conventional irrigation. Significant differences were found between groups regarding propagation and temperature (P< 0.0027). Er:YAG and CO2 laser had similar effects on irrigant propagation in middle and apical located side-canals with specific power parameters and were superior to diode lasers and syringe irrigation. The irrigant's temperature increased significantly with the diode and CO2 lasers. CLINICAL SIGNIFICANCE: Diode lasers and CO2 lasers have not been established for irrigant activation. 9,300 nm CO2 lasers absorb well in water and were shown to introduce vapor bubble formation and streaming in water. Diode lasers are highly accepted in periodontics. The laser light is not absorbed in water but interacts with bacteria as well as soft tissues and contributes therefore to infection control. With a modified laser tip it was however possible to introduce cavitation and streaming in irrigants.


Subject(s)
Carbon Dioxide , Lasers, Solid-State , Lasers, Semiconductor , Proof of Concept Study , Root Canal Irrigants , Dental Pulp Cavity/microbiology , Water , Root Canal Preparation/methods
14.
J Contemp Dent Pract ; 25(2): 180-185, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38514417

ABSTRACT

AIM: To evaluate the intensity of postendodontic pain (PEP) using final irrigation with side-vented needle (SV), EndoActivator (EA), and Ultra X (UX) in single-visit endodontics (SVE) with F-One rotary files. MATERIALS AND METHODS: A total 150 patients indicated for endodontic treatment were selected. Single-visit endodontics treatment was performed under local anesthesia. For the final irrigation protocol, they were divided into three groups: group I (SV), group II (EA), and group III (UX). The severity of PEP was assessed using visual analogue scale (VAS) score after 6, 12, 24, and 48 hours. Analgesics taken by patients, for pain, were also recorded. Finally, the data were tabulated and statistically analyzed using SPSS 20.0 software at a level of significance being 0.05. RESULTS: Postendodontic pain was less in group III (UX) and group II (EA) compared with group I (SV) at 6 and 12 hours, which is statistically significant (p < 0.05). There was no statistically significant difference found after 24 hours and 48 hours. CONCLUSION: The intensity of PEP was minimum in patients treated with EndoActivator and ultrasonic along with single rotary file systems. The incidence of analgesic intake was similar in all three groups. How to cite this article: Kathiria NV, Attur K, Bagda KM, et al. Postendodontic Pain Using Single File System with Different Irrigation Protocols in Single-visit Root Canal Treatment: A Randomized Control Trial. J Contemp Dent Pract 2024;25(2):180-185.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Humans , Pain, Postoperative , Randomized Controlled Trials as Topic , Root Canal Preparation/methods , Root Canal Therapy/methods , Ultrasonics , Double-Blind Method
15.
Braz Dent J ; 35: e245611, 2024.
Article in English | MEDLINE | ID: mdl-38537014

ABSTRACT

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Humans , Root Canal Preparation/methods , Ultrasonics , Root Canal Irrigants , Therapeutic Irrigation/methods , X-Ray Microtomography , Dentin
16.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 75-81, 2024 Feb 01.
Article in English, Chinese | MEDLINE | ID: mdl-38475954

ABSTRACT

OBJECTIVES: This study aimed to compare the differences among four kinds of mechanical Ni-Ti files including T-Flex, Reciproc Blue (RB), ProTaper Gold (PTG), and ProTaper Universal (PTU) in dentinal microcrack generation after root canal preparation in vitro by using micro-computed tomography (micro-CT) analysis. METHODS: A total of 32 freshly extracted double-root-canal premolars with an angle not exceeding 10° were selected and established as root canal preparation models in vitro. Then, the specimens were randomly assigned to four experimental groups (n=8) according to the different Ni-Ti systems used for root canal preparation: group T-Flex, group RB, group PTG, and group PTU. The voxel size of the micro-CT was set at 17.18 µm. Pre- and post-operative cross-sectional images of roots (n=56 940) were scanned and analyzed to identify the presence of dentinal microcracks. The results of each group were expressed by the quantity and percentage of sectional images with microcracks. McNemar test was used to determine whether a significant difference existed in the existence of dentinal microcracks before and after instrumentation. The level of significance was set at P<0.05. RESULTS: Overall, 11.04% of the images presented dentinal defects (n=6 288). Dentinal microcracks were observed in 9.82%, 10.79%, 12.27%, and 11.25% of the post-instrumentation images from groups T-Flex, RB, PTG, and PTU, respectively. However, all these dentinal microcracks were already present in the corresponding pre-operative images. No new microcrack of premolars were generated after the root canal preparation utilizing the aforementioned systems. CONCLUSIONS: Denti-nal microcracks already existed in advance in extracted teeth before root canal preparation. Root canal preparation using the T-Flex, RB, PTG, and PTU systems did not induce the formation of new dentinal microcracks on the straight root canals of premolars.


Subject(s)
Alloys , Nickel , Root Canal Preparation , Root Canal Preparation/methods , Titanium , X-Ray Microtomography , Dentin , Dental Pulp Cavity
17.
J Endod ; 50(5): 659-666, 2024 May.
Article in English | MEDLINE | ID: mdl-38431198

ABSTRACT

INTRODUCTION: To evaluate the push-out bond strength (POBS) of AH Plus sealer to root dentin and the adhesive interface quality after calcium hydroxide (Ca(OH)2) intracanal dressing removal with different final irrigation protocols. METHOD: After root canal instrumentation and irrigation, 40 root canals were filled with Ca(OH)2 and sealed. After 14 days, the specimens were randomly distributed according to the irrigation protocols for Ca(OH)2 removal (n = 10): GH2O (control) - distilled water; GNaOCl - 1% NaOCl; GEDTA - 17% EDTA; GEDTA + NaOCl - 17% EDTA + 1% NaOCl. The root canals were filled with AH Plus sealer and gutta-percha. After 7 days, the roots were sectioned into dentin slices and submitted to POBS test and analysis of the adhesive interface under scanning electron microscope. The POBS data were statistically evaluated (analysis of variance and Tukey test). The Kruskal-Wallis and Mann-Whitney tests were used to analyze the adhesive interface (α = 0.05). RESULTS: GH2O, GNaOCl, and GEDTA + NaOCl had similar POBS values, with higher values on the apical third, in comparison with other thirds (P < .05). A homogeneous and free-of-gaps adhesive interface was observed for GH2O, GNaOCl, and GEDTA + NaOCl, with difference between GH2O and GEDTA (P < .05). GH2O and GEDTA + NaOCl presented higher sealer tags formation (P < .05). CONCLUSION: The final rinse with EDTA for Ca(OH)2 dressing removal had a negative effect on the POBS of the filling material to root dentin. The use of EDTA followed by NaOCl had results similar to the distilled water, providing uniform and free-of-gaps adhesive interface, and a higher number of sealer tags.


Subject(s)
Calcium Hydroxide , Dental Bonding , Dentin , Epoxy Resins , Root Canal Filling Materials , Root Canal Irrigants , Therapeutic Irrigation , Calcium Hydroxide/chemistry , Humans , Dentin/drug effects , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Dental Bonding/methods , Therapeutic Irrigation/methods , Dental Pulp Cavity/drug effects , Microscopy, Electron, Scanning , Sodium Hypochlorite/chemistry , Edetic Acid , Root Canal Preparation/methods , Dental Stress Analysis , Materials Testing
18.
J Endod ; 50(6): 827-834, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38431197

ABSTRACT

INTRODUCTION: This study aimed to investigate the effect of radiotherapy and taper of root canal preparation on the biomechanical behavior of mesial roots of mandibular molars. METHODS: Eighty mandibular molars with 2 canals in the mesial root were randomly allocated into 2 groups (n = 40): one group underwent irradiation (60 Gy), while the other did not. Subsequently, the mesial roots were sectioned and each group was subdivided into 5 subgroups (n = 8), according to the preparation taper: no preparation (control); 25.03; 25.04; 25.06; and 25.08. All groups were considered homogeneous regarding their dimensions, weight, and morphology. The prepared specimens were embedded in cylindrical plastic molds and subjected to a cyclic fatigue test. A failure analysis was performed according to the extension and course of the fractures. Two-way ANOVA, Tukey's post-hoc, Fisher's exact, and Kaplan-Meier tests were conducted to evaluate the obtained data (α = 5%). RESULTS: Fatigue resistance decreased as the taper of the preparation increased (P < .05). Preparation 25.03 presented significantly higher values only than 25.08 (P < .05), while 25.04, 25.06, and 25.08 were considered similar (P > .05). Irradiation significantly reduced the biomechanical performance (P < .05). Survival analysis corroborated these findings. There were no differences in the distribution of fracture types among the groups (P > .05). CONCLUSION: The biomechanical behavior of the mesial roots of the mandibular molars decreased significantly in the face of irradiation and as the taper of the preparation increased.


Subject(s)
Mandible , Molar , Root Canal Preparation , Tooth Root , Humans , Biomechanical Phenomena , Root Canal Preparation/methods , Tooth Root/radiation effects , Dental Stress Analysis
19.
Eur Arch Paediatr Dent ; 25(2): 181-189, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38461490

ABSTRACT

PURPOSE: Pulpectomy can be used for the management of deep dentinal carious lesions in primary teeth which can be restored. Mechanical preparation of root canals can be performed using hand or NiTi rotary files. However, this may cause dentinal stress and consequently dentinal microcracks. Hence, the aim was comparative evaluation of hand and rotary file systems on dentinal microcrack formation during pulpectomy procedure in primary teeth. METHODS: 60 extracted primary molar teeth were selected comprising of 80 root canals. Simple random sampling was used to divide root canals into four groups (n = 20): Group A-Hedstrom file, Group B-Pro AF Baby Gold rotary, Group C-ProTaper Next rotary, and Group D-unprepared group. Assessment was conducted on presence or absence of microcracks using Chi square test (p < 0.05). RESULTS: The total number of microcracks in Group A: one (5%), Group B: four (20%), Group C: nine (45%) and Group D: zero (0%) which was statistically significant (p = 0.002). At cervical third, the number of microcracks seen with Group A: one (5%), Group B: zero (0%), Group C: five (25%) and Group D: zero (0%) (p = 0.005). At the middle third, the number of microcracks seen in Group A: zero (0%), Group B: four (20%), Group C: four (20%) and Group D: zero (0%) (p = 0.029). CONCLUSION: The study concluded that dentinal microcracks are formed with both hand and rotary file systems in primary teeth. ProTaper Next showed significantly higher number of microcracks, followed by ProAF Baby Gold and H files.


Subject(s)
Dentin , Pulpectomy , Root Canal Preparation , Tooth, Deciduous , Humans , Tooth, Deciduous/surgery , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Pulpectomy/methods , Dentin/injuries , In Vitro Techniques , Dental Instruments/adverse effects , Molar/surgery , Equipment Design , Dental Pulp Cavity/surgery , Nickel
20.
Eur Arch Paediatr Dent ; 25(2): 227-235, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38472709

ABSTRACT

PURPOSE: To evaluate the volumetric changes of two recently introduced paediatric rotary file systems in comparison with conventional hand file systems in primary maxillary canines using an ultra-high-resolution nano-computed tomography. METHODS: This in vitro study was performed in extracted primary maxillary canines based on certain inclusion and exclusion criteria. Samples were prepared, and working length was determined after the pre-operative scan using a high-resolution nano-CT device (SkyScan 2214, Bruker, Kontich, Belgium). A single well-experienced paediatric dentist prepared the canals using three file systems: Kedo-S plus, Kedo-SG blue and hand K-files. All samples were subjected to post-operative scans performed similar to pre-operative scans. Image reconstruction was performed with NRecon software for 3D volumetric visualisation and analysis of the root canals. RESULTS: Kedo-SG blue file systems had the highest mean difference in the canal volume (4.05%). Hand K-files had the least difference at (3.71%) of canal volume. Kedo-S plus file system had a moderate mean canal volume difference (3.82%) which is closer to hand K-files. Intergroup comparison between the three groups showed that the mean difference in canal volume was statistically significant between all three file systems (p = 0.000). CONCLUSION: Within the limitations of the current study, rotary file systems produced a significant enlargement of canals as compared to hand files. Kedo-SG blue created a uniform preparation of the canal cervico-apically. Kedo-S plus files were prepared more coronally with minimal preparation apically as close to the preparation of hand files. TRIAL REGISTRATION: Trial registration number: IHEC/SDC/PEDO-2103/22/651, Date of registration: 2022.


Subject(s)
Cuspid , Dental Pulp Cavity , Maxilla , Root Canal Preparation , Tooth, Deciduous , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Cuspid/diagnostic imaging , Cuspid/anatomy & histology , Tooth, Deciduous/diagnostic imaging , Tooth, Deciduous/anatomy & histology , Maxilla/diagnostic imaging , In Vitro Techniques , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Dental Instruments , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...