Results 1 - 20 de 14.136
Filter
1.
BMC Oral Health ; 24(1): 619, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807138

ABSTRACT

PURPOSE: The aim of this in vitro study was to evaluate the changes the rheological properties of some soft lining materials, to compare the rheological properties and viscoelastic behaviour at different temperatures. MATERIALS AND METHODS: Five soft lining materials (acrylic and silicone based) were used. the storage modulus (G'), loss modulus (G"), tan delta (tan δ) and complex viscosity (η') were chosen and for each material, measurements were repeated at 23, 33 and 37  °C, using an oscillating rheometer. All data were statistically analyzed using the Mann Whitney U test, Kruskal Wallis test and Conover's Multiple Comparison test at the significance level of 0.05. RESULTS: Soft lining materials had different viscoelastic properties and most of the materials showed different rheological behavior at 23, 33 and 37  °C. At the end of the test (t¹5), at all the temperatures, Sofreliner Tough M had the highest storage modulus values while Visco Gel had the highest loss Tan delta values. CONCLUSIONS: There were significant changes in the rheological parameters of all the materials. Also temperature affected the initial rheological properties, and polymerization reaction of all the materials, depending on temperature increase. CLINICAL IMPLICATIONS: Temperature affected the initial rheological properties, and polymerization reaction of soft denture liner materials, and clinical inferences should be drawn from such studies conducted. It can be recommended to utilize viscoelastic acrylic-based temporary soft lining materials with lower storage modulus, higher tan delta value, and high viscosity in situations where pain complaint persists and tissue stress is extremely significant, provided that they are replaced often.


Subject(s)
Acrylic Resins , Materials Testing , Rheology , Temperature , Viscosity , Acrylic Resins/chemistry , Elasticity , Denture Liners , Elastic Modulus , Dental Cavity Lining , Silicones/chemistry , Polymerization , Humans , Oscillometry
2.
Molecules ; 29(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792087

ABSTRACT

In this work, we present the modification of a medical-grade silicone catheter with the N-vinylimidazole monomer using the grafting-from method at room temperature and induced by gamma rays. The catheters were modified by varying the monomer concentration (20-100 vol%) and the irradiation dose (20-100 kGy). Unlike the pristine material, the grafted poly(N-vinylimidazole) chains provided the catheter with hydrophilicity and pH response. This change allowed for the functionalization of the catheters to endow it with antimicrobial features. Thus, the quaternization of amines with iodomethane and bromoethane was performed, as well as the immobilization of silver and ampicillin. The inhibitory capacity of these materials, functionalized with antimicrobial agents, was challenged against Escherichia coli and Staphylococcus aureus strains, showing variable results, where loaded ampicillin was amply better at eliminating bacteria.


Subject(s)
Escherichia coli , Imidazoles , Silicones , Staphylococcus aureus , Escherichia coli/drug effects , Staphylococcus aureus/drug effects , Silicones/chemistry , Imidazoles/chemistry , Imidazoles/pharmacology , Catheters/microbiology , Microbial Sensitivity Tests , Polyvinyls/chemistry , Anti-Infective Agents/chemistry , Anti-Infective Agents/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Ampicillin/chemistry , Ampicillin/pharmacology , Gamma Rays
3.
Ther Adv Respir Dis ; 18: 17534666241254901, 2024.
Article in English | MEDLINE | ID: mdl-38785036

ABSTRACT

The two patients included in the study had mixed and refractory post-tuberculosis tracheobronchial stenosis (PTTS), having experienced unsuccessful interventional therapies such as balloon dilation and V-shaped stent placement before the operation. Following the secure placement of L-shaped silicone stents, examinations with a fiberbronchoscope during the first and third months post-operation revealed a significant reduction in bronchial mucosa inflammation for both patients. Additionally, the opening diameter of the upper and lower branch segments increased, and chest CT scans indicated a noticeable absorption of left pulmonary lesions. Three months post-operation, fiberbronchoscopy confirmed the stable fixation of the stent without any movement. The patients exhibited substantial improvements in pulmonary function, dyspnea index, and blood gas analysis, with no reported adverse complications. After 7 months, a follow-up fiberbronchoscope for one case revealed excellent stent fixation. Simultaneously, the chest CT scan indicated favorable re-expansion. The placement of L-shaped silicone stents proves effective in preventing displacement, alleviating airway stenosis or obstruction, and ensuring the safety and efficacy of PTTS treatment - particularly in cases where V-shaped silicone stent placement has failed. To our knowledge, this is the first study describing the L-shaped silicone stent in two patients with PTTS.


Successful treatment of severe airway narrowing due to tuberculosis using special L-shaped silicone stentsThis article tells the story of two patients who suffered from a complex lung condition called post-tuberculosis tracheobronchial stenosis (PTTS). Imagine your airways - the tubes that carry air to your lungs - getting severely scarred and narrowed due to a past bout with tuberculosis. These two patients had tried previous treatments like balloon dilation (where a small balloon is inflated inside the narrowed airway to widen it) and using V-shaped stents (flexible supports placed in the airway to keep it open), but these methods didn't provide lasting relief. In this innovative approach, doctors used L-shaped silicone stents specifically designed to fit in the affected parts of the patients' airways. After placing these stents, regular checks showed remarkable improvements. The swelling in the airway lining reduced significantly, and the openings leading to the upper and lower parts of the lungs got wider. Chest X-rays (CT scans) even showed that the patient's left lung was healing well. Three months later, the stents stayed firmly in place, and neither patient experienced any problems. Breathing became easier, lung function tests improved, and blood tests showed better oxygen levels. Seven months down the line, one patient continued to do extremely well, with the stent securely fixed and the chest scan showing good lung expansion. This groundbreaking study shows that using L-shaped silicone stents can effectively treat PTTS when other methods fail. Not only do they stay in place, preventing blockages, but they also safely and effectively alleviate narrowing of the airways. It's the first time such L-shaped stents have been used successfully in PTTS patients, offering new hope for those facing similar challenges.


Subject(s)
Bronchial Diseases , Bronchoscopy , Silicones , Stents , Tracheal Stenosis , Humans , Bronchial Diseases/etiology , Bronchial Diseases/therapy , Bronchial Diseases/physiopathology , Tracheal Stenosis/therapy , Tracheal Stenosis/etiology , Bronchoscopy/instrumentation , Male , Constriction, Pathologic , Female , Treatment Outcome , Adult , Middle Aged , Prosthesis Design , Tuberculosis, Pulmonary/complications , Tomography, X-Ray Computed
4.
Ecotoxicol Environ Saf ; 278: 116349, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38714081

ABSTRACT

BACKGROUND: Exposures to polyaromatic hydrocarbons (PAHs) contribute to cancer in the fire service. Fire investigators are involved in evaluations of post-fire scenes. In the US, it is estimated that there are up to 9000 fire investigators, compared to approximately 1.1 million total firefighting personnel. This exploratory study contributes initial evidence of PAH exposures sustained by this understudied group using worn silicone passive samplers. OBJECTIVES: Evaluate PAH exposures sustained by fire investigators at post-fire scenes using worn silicone passive samplers. Assess explanatory factors and health risks of PAH exposure at post-fire scenes. METHODS: As part of a cross-sectional study design, silicone wristbands were distributed to 16 North Carolina fire investigators, including eight public, seven private, and one public and private. Wristbands were worn during 46 post-fire scene investigations. Fire investigators completed pre- and post-surveys providing sociodemographic, occupational, and post-fire scene characteristics. Solvent extracts from wristbands were analyzed via gas chromatography-mass spectrometry (GC-MS). Results were used to estimate vapor-phase PAH concentration in the air at post-fire scenes. RESULTS: Fire investigations lasted an average of 148 minutes, standard deviation ± 93 minutes. A significant positive correlation (r=0.455, p<.001) was found between investigation duration and PAH concentrations on wristbands. Significantly greater time-normalized PAH exposures (p=0.039) were observed for investigations of newer post-fire scenes compared to older post-fire scenes. Regulatory airborne PAH exposure limits were exceeded in six investigations, based on exposure to estimated vapor-phase PAH concentrations in the air at post-fire scenes. DISCUSSION: Higher levels of off-gassing and suspended particulates at younger post-fire scenes may explain greater PAH exposure. Weaker correlations are found between wristband PAH concentration and investigation duration at older post-fire scenes, suggesting reduction of off-gassing PAHs over time. Exceedances of regulatory PAH limits indicate a need for protection against vapor-phase contaminants, especially at more recent post-fire scenes.


Subject(s)
Firefighters , Occupational Exposure , Polycyclic Aromatic Hydrocarbons , Silicones , Humans , Polycyclic Aromatic Hydrocarbons/analysis , Occupational Exposure/analysis , Cross-Sectional Studies , North Carolina , Adult , Male , Female , Middle Aged , Environmental Monitoring/methods , Air Pollutants, Occupational/analysis , Gas Chromatography-Mass Spectrometry , Wrist
5.
World J Pediatr Congenit Heart Surg ; 15(3): 332-339, 2024 May.
Article in English | MEDLINE | ID: mdl-38646823

ABSTRACT

Objective: Hands-on surgical training (HOST) for congenital heart surgery (CHS), utilizing silicone-molded models created from 3D-printing of patients' imaging data, was shown to improve surgical skills. However, the impact of repetition and frequency of repetition in retaining skills has not been previously investigated. We aimed to longitudinally evaluate the outcome for HOST on two example procedures of different technical difficulties with repeated attempts over a 15-week period. Methods: Five CHS trainees were prospectively recruited. Repair of coarctation of the aorta (CoA) and arterial switch operation (ASO) were selected as example procedures of relatively low and high technical difficulty. Procedural time and technical performance (using procedure-specific assessment tools by the participant, a peer-reviewer, and the proctor) were measured. Results: Coarctation repair performance scores improved after the first repetition but remained unchanged at the follow-up session. Likewise, CoA procedural time showed an early reduction but then remained stable (mean [standard deviation]: 29[14] vs 25[15] vs 23[9] min at 0, 1, and 4 weeks). Conversely, ASO performance scores improved during the first repetitions, but decreased after a longer time delay (>9 weeks). Arterial switch operation procedural time showed modest improvements across simulations but significantly reduced from the first to the last attempt: 119[20] versus 106[28] min at 0 and 15 weeks, P = .049. Conclusions: Complex procedures require multiple HOST repetitions, without excessive time delay to maintain long-term skills improvement. Conversely, a single session may be planned for simple procedures to achieve satisfactory medium-term results. Importantly, a consistent reduction in procedural times was recorded, supporting increased surgical efficiency.


Subject(s)
Cardiac Surgical Procedures , Clinical Competence , Humans , Prospective Studies , Cardiac Surgical Procedures/methods , Models, Anatomic , Heart Defects, Congenital/surgery , Silicones , Printing, Three-Dimensional , Male , Female , Longitudinal Studies , Aortic Coarctation/surgery , Education, Medical, Graduate/methods
6.
Environ Pollut ; 349: 123877, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38574945

ABSTRACT

Silicone wristbands are a noninvasive personal exposure assessment tool. However, despite their utility, questions remain about the rate at which chemicals accumulate on wristbands when worn, as validation studies utilizing wristbands worn by human participants are limited. This study evaluated the chemical uptake rates of 113 organic pollutants from several chemical classes (i.e., polychlorinated biphenyls (PCB), organophosphate esters (OPEs), alkyl OPEs, polybrominated diphenyl ethers (PBDEs), brominated flame retardants (BFR), phthalates, pesticides, and polycyclic aromatic hydrocarbons (PAHs) over a five-day period. Adult participants (n = 10) were asked to wear five silicone wristbands and then remove one wristband each day. Several compounds were detected in all participants' wristbands after only one day. The number of chemicals detected frequently (i.e. in at least seven participants wristbands) increased from 20% of target compounds to 26% after three days and more substantially increased to 34% of target compounds after four days of wear. Chemicals detected in at least seven participants' day five wristbands (n = 24 chemicals) underwent further statistical analysis, including estimating the chemical uptake rates over time. Some chemicals, including pesticides and phthalates, had postive and significant correlations between concentrations on wristbands worn five days and concentrations of wristbands worn fewer days suggesting chronic exposure. For 23 of the 24 compounds evaluated there was a statistically significant and positive linear association between the length of time wristbands were worn and chemical concentrations in wristbands. Despite the differences that exist between laboratory studies using polydimethylsiloxane (PDMS) environmental samplers and worn wristbands, these results indicate that worn wristbands are primarily acting as first-order kinetic samplers. These results suggest that studies using different deployment lengths should be comparable when results are normalized to the length of the deployment period. In addition, a shorter deployment period could be utilized for compounds that were commonly detected in as little as one day.


Subject(s)
Environmental Monitoring , Environmental Pollutants , Flame Retardants , Silicones , Humans , Adult , Flame Retardants/analysis , Environmental Pollutants/analysis , Environmental Monitoring/methods , Male , Female , Environmental Exposure/statistics & numerical data , Environmental Exposure/analysis , Halogenated Diphenyl Ethers/analysis , Polychlorinated Biphenyls/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Pesticides/analysis , Young Adult , Wrist , Phthalic Acids/analysis
7.
Article in Chinese | MEDLINE | ID: mdl-38664028

ABSTRACT

Objective: To explore the effect of early eschar dermabrasion combined with antimicrobial soft silicone foam dressing (hereinafter referred to as foam dressing) in treating the deep partial-thickness burn wounds in children. Methods: This study was a randomized controlled trial. From June 2021 to December 2022, 78 pediatric patients with deep partial-thickness burns who met the inclusion criteria were admitted to the Department of Burns in Guiyang Steel Plant Employees Hospital. According to the random number table, the pediatric patients were divided into two groups, with 38 cases left in combined treatment group (with 20 males and 18 females, aged 26.00 (16.75, 39.75) months) and 39 cases in foam dressing group (with 21 males and 18 females, aged 19.00 (14.00, 31.00) months) after the exclusion of one dropped-out child in follow-up. The pediatric patients in combined treatment group underwent eschar dermabrasion of the wound within 48 hours after injury, the wound was covered with foam dressing after operation, and the dressing was replaced once every 7 days; for the pediatric patients in foam dressing group, the wound was sterilized within 48 hours after injury and covered with foam dressing, and the dressing was replaced once every 2 to 3 days. After the wound healing, the children in both groups were routinely applied with silicone gel twice a day for 3 weeks before started wearing elastic sleeves for more than 18 hours a day, and continuously for over than 6 months. The degree of pain during dressing change was evaluated using the children's pain behavior inventory FLACC. The adverse reactions during the treatment period, number of dressing changes, and wound healing time were observed and recorded. Six months after wound healing, the Vancouver scar scale (VSS) was used to evaluate the condition of the wound scar. Results: When changing dressing, the FLACC score for pain of pediatric patients in combined treatment group was 3.5 (2.0, 5.0), which was significantly lower than 6.0 (5.0, 8.0) in foam dressing group (Z=-5.40, P<0.05). During the treatment period, no adverse reactions such as wound edema, fluid accumulation, or peripheral skin rash allergies occurred in any pediatric patient in both groups. The number of dressing changes of pediatric patients in combined treatment group was 3 (3, 4) times, which was significantly less than 8 (7, 10) times in foam dressing group (Z=-7.58, P<0.05). The wound healing time of pediatric patients in combined treatment group was (19±5) days, which was significantly shorter than (25±6) days in foam dressing group (t=-4.48, P<0.05). Six months after wound healing, the VSS score for scar of pediatric patients in combined treatment group was 5 (2, 8), which was significantly lower than 7 (5, 10) in foam dressing group (Z=-3.05, P<0.05). Conclusions: Compared with using foam dressings alone, early eschar dermabrasion combined with foam dressings can reduce the number of dressing changes, alleviate the pain during dressing changes, and shorten the wound healing time in treating children with deep partial-thickness burns, and effectively alleviate scar hyperplasia by combining with anti-scar treatment post burns.


Subject(s)
Bandages , Burns , Dermabrasion , Wound Healing , Humans , Male , Female , Burns/therapy , Burns/drug therapy , Child, Preschool , Infant , Wound Healing/drug effects , Dermabrasion/methods , Silicones/administration & dosage , Anti-Infective Agents/therapeutic use , Anti-Infective Agents/administration & dosage
8.
J Am Soc Mass Spectrom ; 35(5): 829-833, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38564189

ABSTRACT

A new approach using orthogonal analytical techniques is developed for chemical identification. High resolution mass spectrometry and infrared ion spectroscopy are applied through a 5-level confidence paradigm to demonstrate the effectiveness of nontargeted workflow for the identification of hazardous organophosphates. Triphenyl phosphate is used as a surrogate organophosphate for occupational exposure, and silicone wristbands are used to represent personal samplers. Spectral data of a target compound is combined with spectral data of the sodium adduct and quantum chemical calculations to achieve a confirmed identification. Here, we demonstrate a nontargeted workflow that identifies organophosphate exposure and provides a mechanism for selecting validated methods for quantitative analyses.


Subject(s)
Occupational Exposure , Silicones , Spectrophotometry, Infrared , Workflow , Occupational Exposure/analysis , Silicones/chemistry , Humans , Spectrophotometry, Infrared/methods , Mass Spectrometry/methods , Environmental Monitoring/methods , Organophosphates/analysis , Organophosphates/chemistry
9.
ACS Biomater Sci Eng ; 10(5): 3006-3016, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38640484

ABSTRACT

Soft implantable devices are crucial to optimizing form and function for many patients. However, periprosthetic capsule fibrosis is one of the major challenges limiting the use of implants. Currently, little is understood about how spatial and temporal factors influence capsule physiology and how the local capsule environment affects the implant structure. In this work, we analyzed breast implant capsule specimens with staining, immunohistochemistry, and real-time polymerase chain reaction to investigate spatiotemporal differences in inflammation and fibrosis. We demonstrated that in comparison to the anterior capsule against the convex surface of breast implants, the posterior capsule against the flat surface of the breast implant displays several features of a dysregulated foreign body reaction including increased capsule thickness, abnormal extracellular remodeling, and infiltration of macrophages. Furthermore, the expression of pro-inflammatory cytokines increased in the posterior capsule across the lifespan of the device, but not in the anterior capsule. We also analyzed the surface oxidation of breast explant samples with XPS analysis. No significant differences in surface oxidation were identified either spatially or temporally. Collectively, our results support spatiotemporal heterogeneity in inflammation and fibrosis within the breast implant capsule. These findings presented here provide a more detailed picture of the complexity of the foreign body reaction surrounding implants destined for human use and could lead to key research avenues and clinical applications to treat periprosthetic fibrosis and improve device longevity.


Subject(s)
Breast Implants , Fibrosis , Foreign-Body Reaction , Surface Properties , Breast Implants/adverse effects , Humans , Foreign-Body Reaction/pathology , Foreign-Body Reaction/metabolism , Foreign-Body Reaction/immunology , Female , Silicones/chemistry , Silicone Gels/adverse effects , Cytokines/metabolism , Inflammation/pathology , Inflammation/metabolism , Macrophages/metabolism , Macrophages/immunology
10.
Top Curr Chem (Cham) ; 382(2): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38589726

ABSTRACT

Silicone surfactants have garnered significant research attention owing to their superior properties, such as wettability, ductility, and permeability. Small-molecular silicone surfactants with simple molecular structures outperform polymeric silicone surfactants in terms of surface activity, emulsification, wetting, foaming, and other areas. Moreover, silicone surfactants with small molecules exhibit a diverse and rich molecular structure. This review discusses various synthetic routes for the synthesis of different classes of surfactants, including single-chain, "umbrella" structure, double chain, bolaform, Gemini, and stimulus-responsive surfactants. The fundamental surface/interface properties of the synthesized surfactants are also highlighted. Additionally, these surfactants have demonstrated enormous potential in agricultural synergism, drug delivery, mineral flotation, enhanced oil recovery, separation, and extraction, and foam fire-fighting.


Subject(s)
Silicones , Surface-Active Agents , Surface-Active Agents/chemistry , Surface Properties , Molecular Structure
11.
Front Immunol ; 15: 1342895, 2024.
Article in English | MEDLINE | ID: mdl-38566997

ABSTRACT

Excessive fibrous capsule formation around silicone mammary implants (SMI) involves immune reactions to silicone. Capsular fibrosis, a common SMI complication linked to host responses, worsens with specific implant topographies. Our study with 10 patients investigated intra- and inter-individually, reduced surface roughness effects on disease progression, wound responses, chronic inflammation, and capsular composition. The results illuminate the significant impact of surface roughness on acute inflammatory responses, fibrinogen accumulation, and the subsequent fibrotic cascade. The reduction of surface roughness to an average roughness of 4 µm emerges as a promising approach for mitigating detrimental immune reactions, promoting healthy wound healing, and curbing excessive fibrosis. The identified proteins adhering to rougher surfaces shed light on potential mediators of pro-inflammatory and pro-fibrotic processes, further emphasizing the need for meticulous consideration of surface design. The composition of the implant capsule and the discovery of intracapsular HSP60 expression highlight the intricate web of stress responses and immune activation that can impact long-term tissue outcomes.


Subject(s)
Inflammation , Prostheses and Implants , Humans , Silicones , Fibrosis , Wound Healing
12.
Gan To Kagaku Ryoho ; 51(4): 460-462, 2024 Apr.
Article in Japanese | MEDLINE | ID: mdl-38644322

ABSTRACT

Recently, the cases of breast augmentation for cosmetic purposes are rapidly increasing, there are more opportunities to examine for patient with breast augmentation history than before. In some cases, breast cancer screening is difficult due to the effects of breast augmentation. At our clinic, even in cases diagnosed with breast cancer after breast augmentation, we actively perform immediate breast reconstruction using silicone implant. However, it is necessary to consider the condition and type of breast augmentation at the time of diagnosis and also treatment. We will share our algorithm for immediate breast reconstruction using silicone implant for breast cancer after augmentation mammaplasty.


Subject(s)
Algorithms , Breast Implants , Breast Neoplasms , Mammaplasty , Humans , Breast Neoplasms/surgery , Female , Mammaplasty/methods , Silicones
13.
Environ Sci Technol ; 58(15): 6772-6780, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38577774

ABSTRACT

The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments.


Subject(s)
Polyethylene , Water Pollutants, Chemical , Polyethylene/analysis , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Organic Chemicals , Silicones
14.
J Adhes Dent ; 26(1): 93-102, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38602286

ABSTRACT

PURPOSE: To investigate the influence of contamination and different cleaning methods on resin bonding to cobalt-chro- mium (CoCr) alloy disks. MATERIALS AND METHODS: A total of 160 CoCr disks were divided into 3 groups. The first group (N = 64) was air abraded with alumina particles and contaminated with a silicone disclosing agent and saliva; the second group (N = 64) was air abraded but not contaminated; the third group (N = 32) was neither air abraded nor contaminated. The first two groups were di- vided into 4 subgroups (N = 16) according to the cleaning method: ultrasonic bath in 99% isopropanol, use of a cleaning suspension of zirconium oxide particles, use of a cleaning suspension based on 10-MDP salt, and treatment with atmo- spheric plasma. The third group was divided into 2 subgroups (N = 16): treatment with atmospheric plasma and no treat- ment. All CoCr specimens were bonded to plexiglas tubes filled with a bonding resin that contained phosphate monomer. Tensile bond strength (TBS) was examined by tensile testing after 3 and 150 days of water storage plus 37,500 thermal cy- cles (N = 8). RESULTS: After contamination, TBS was significantly reduced after 150 days of water storage. Groups without air abrasion showed initially low TBS and debonded spontaneously after 150 days of water storage. CONCLUSION: None of the cleaning methods was able to remove saliva and silicone disclosing agent on CoCr-alloy sur- faces. Surface activation by plasma treatment has no long-term effect on the bond strength.


Subject(s)
Composite Resins , Dental Bonding , Resin Cements , Alloys , Air Abrasion, Dental , Surface Properties , Water , Tensile Strength , Silicones , Materials Testing , Zirconium , Dental Stress Analysis
15.
Environ Sci Technol ; 58(15): 6499-6508, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38572580

ABSTRACT

A social housing estate in Denmark was designated for demolition due to exceedance of guidance values for polychlorinated biphenyls (PCBs) in indoor air. Here, we deployed precleaned silicone wristbands (n = 46) among demolition workers of these contaminated buildings during single workdays while conducting various work tasks. We established a method to analyze all 209 PCBs in wristbands to identify prominent congeners of exposure and evaluate differences between tasks. Wristbands were extracted using microwave-assisted extraction and then concentrated for gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. Twenty-nine chromatographic peaks representing 37 congeners were detected in every wristband, and tetra-CBs were the dominant homologue group. PCB-66, -44, and -70 were the most abundant congeners measured in worker wristbands, none of which are included within the typical seven indicator or WHO 12 PCBs. Workers who cut PCB-containing sealants had wristbands with the highest PCB concentrations (geometric mean ∑209PCBs = 1963 ng/g wristband), which were followed by those handling concrete elements on the building roof. Additionally, wristbands captured a broader range of PCBs than has been previously measured in air and serum samples. Taken together, our results highlight the importance of total congener analysis in assessing current PCB exposure in demolition work and the utility of wristbands for assessing these exposures.


Subject(s)
Polychlorinated Biphenyls , Humans , Polychlorinated Biphenyls/analysis , Environmental Monitoring , Tandem Mass Spectrometry , Silicones
16.
Sci Total Environ ; 927: 172187, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38582107

ABSTRACT

Plasticizers (PLs) and organophosphate flame retardants (OPFRs) are ubiquitous in the environment due to their widespread use and potential for leaching from consumer products. Environmental exposure is a critical aspect of the human exposome, revealing complex interactions between environmental contaminants and potential health effects. Silicone wristbands (SWBs) have emerged as a novel and non-invasive sampling device for assessing personal external exposure. In this study, SWBs were used as a proxy to estimate personal dermal adsorption (EDdermal) to PLs and OPFRs in Belgian participants for one week; four morning urine samples were also collected and analyzed for estimated daily intake (EDI). The results of the SWBs samples showed that all the participants were exposed to these chemicals, and the exposure was found to be highest for the legacy and alternative plasticizers (LP and AP), followed by the legacy and emerging OPFRs (LOPFR and EOPFR). In urine samples, the highest levels were observed for metabolites of diethyl phthalate (DEP), di-isobutyl phthalate (DiBP) and di-n-butyl phthalate (DnBP) among LPs and di(2-ethylhexyl) terephthalate (DEHT) for APs. Outliers among the participants indicated that there were other sources of exposure that were not identified. Results showed a significant correlation between EDdermal and EDI for DiBP, tris (2-butoxyethyl) phosphate (TBOEP) and triphenyl phosphate (TPhP). These correlations indicated their suitability for predicting exposure via SWB monitoring for total chemical exposure. The results of this pilot study advance our understanding of SWB sampling and its relevance for predicting aggregate environmental chemical exposures, while highlighting the potential of SWBs as low-cost, non-invasive personal samplers for future research. This innovative approach has the potential to advance the assessment of environmental exposures and their impact on public health.


Subject(s)
Environmental Exposure , Environmental Monitoring , Flame Retardants , Organophosphates , Plasticizers , Silicones , Flame Retardants/analysis , Plasticizers/analysis , Humans , Environmental Exposure/statistics & numerical data , Environmental Exposure/analysis , Organophosphates/urine , Belgium , Adult , Environmental Pollutants/urine , Male , Female
17.
Eur Radiol Exp ; 8(1): 40, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38565836

ABSTRACT

BACKGROUND: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. METHODS: The study involved 42 Sprague-Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. RESULTS: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. CONCLUSIONS: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. RELEVANCE STATEMENT: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. KEY POINTS: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis.


Subject(s)
Hyperthermia, Induced , Metal Nanoparticles , Rats , Animals , Gold , Silicones , Feasibility Studies , Rats, Sprague-Dawley , Esophagus , Stents
18.
Sci Adv ; 10(14): eadk5949, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578991

ABSTRACT

The transplantation of engineered cells that secrete therapeutic proteins presents a promising method for addressing a range of chronic diseases. However, hydrogels used to encase and protect non-autologous cells from immune rejection often suffer from poor mechanical properties, insufficient oxygenation, and fibrotic encapsulation. Here, we introduce a composite encapsulation system comprising an oxygen-permeable silicone cryogel skeleton, a hydrogel matrix, and a fibrosis-resistant polymer coating. Cryogel skeletons enhance the fracture toughness of conventional alginate hydrogels by 23-fold and oxygen diffusion by 2.8-fold, effectively mitigating both implant fracture and hypoxia of encapsulated cells. Composite implants containing xenogeneic cells engineered to secrete erythropoietin significantly outperform unsupported alginate implants in therapeutic delivery over 8 weeks in immunocompetent mice. By improving mechanical resiliency and sustaining denser cell populations, silicone cryogel skeletons enable more durable and miniaturized therapeutic implants.


Subject(s)
Cryogels , Hydrogels , Mice , Animals , Silicones , Alginates , Oxygen , Skeleton , Cell Survival
19.
Vet Surg ; 53(4): 761-768, 2024 May.
Article in English | MEDLINE | ID: mdl-38525897

ABSTRACT

OBJECTIVE: To report the long-term outcome of utilization of a silicone stent to support the management of a permanent tracheostomy. STUDY DESIGN: Short case series. ANIMALS: Two client-owned brachycephalic dogs. METHODS: Two brachycephalic dogs with stage III laryngeal collapse underwent permanent tracheostomy. After the tracheostomy had healed, a silicone stent was inserted to support the stoma and facilitate home care. One dog wore a commercially available silicone stent for the follow-up period of 2 years. For the dog in Case 2, a 3D-printed, medical-grade silicone stent with an increased length was designed, as the dog had developed skin sores from the commercial device. RESULTS: Both dogs tolerated the silicone stent well. Stent care was managed by the owners without need for assistance. They reported that the silicone stent facilitated cleaning of the stoma surroundings and that they felt an increased confidence in airway patency, as the device prevented the tracheal stoma from collapsing. In Case 1, tracheoscopy 1 year after first stent insertion revealed minimal visible changes to the tracheal stoma. In Case 2, the 3D printed silicone stent led to a remission of skin sores and the dog wore the device comfortably until succumbing to an unrelated disease 13 months later. CONCLUSION: The insertion of a silicone stent is a simple and cost-effective method to improve home care of dogs with permanent tracheostomy. Larger dogs, as in Case 2, may benefit from custom-designed 3D-printed stents.


Subject(s)
Dog Diseases , Printing, Three-Dimensional , Silicones , Stents , Tracheostomy , Animals , Dogs , Tracheostomy/veterinary , Tracheostomy/instrumentation , Tracheostomy/methods , Stents/veterinary , Dog Diseases/surgery , Male , Female , Treatment Outcome
20.
Bioengineering (Basel) ; 11(3): 1-12, mar.2024.
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1537704

ABSTRACT

Cilia are biological structures essential to drive the mobility of secretions and maintain the proper function of the respiratory airways. However, this motile self-cleaning process is significantly compromised in the presence of silicone tracheal prosthesis, leading to biofilm growth and impeding effective treatment. To address this challenge and enhance the performance of these devices, we propose the fabrication of magnetic silicone cilia, with the prospect of their integration onto silicone prostheses. The present study presents a fabrication method based on magnetic self-assembly and assesses the interaction behavior of the cilia array with biological mucus. This protocol allows for the customization of cilia dimensions across a wide range of aspect ratios (from 6 to 85) and array densities (from 10 to 80 cilia/mm2) by adjusting the fabrication parameters, offering flexibility for adjustments according to their required characteristics. Furthermore, we evaluated the suitability of different cilia arrays for biomedical applications by analyzing their interaction with bullfrog mucus, simulating the airways environment. Our findings demonstrate that the fabricated cilia are mechanically resistant to the viscous fluid and still exhibit controlled movement under the influence of an external moving magnet. A correlation between cilia dimensions and mucus wettability profile suggests a potential role in facilitating mucus depuration, paving the way for further advancements aimed at enhancing the performance of silicone prostheses in clinical settings.


Subject(s)
Silicones , Bioprosthesis , Trachea