Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 13.599
Filter
1.
Pediatr Dent ; 46(3): 199-203, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38822496

ABSTRACT

Purpose: The purposes of this in vitro study were to evaluate the effect of three isolation methods to mitigate bioaerosols during stainless steel crown (SSC) preparations and assess the distribution of Streptococcus mutans by aerosolization in closed-room operatories. Methods: Melamine teeth coated in laboratory-grown S. mutans biofilm were prepared for SSCs using three different isolation methods. Agar plates were placed in five locations throughout the operatory and opened during each preparation as well as for 10 minutes immediately following to collect aerosolized S. mutans. Bacterial colonies were counted after incubating plates for 48 hours. Data were analyzed for differences between the isolation method and plate locations. Results: Bacterial colony counts for teeth prepared using high-volume evacuation suction (HVE) with dental dam (DD) isolation were statistically significantly higher than for those prepared using HVE with a DryShield®(DS) and HVE with no isolation at the assistant (A) (P<0.001), operator face shield (FS) (P<0.001), and patient (Pt) (P=0.002) locations. No significant differences were found among isolation methods for parent (Pa) or rear delivery (RD) locations. The location that produced the most bacterial colony counts using HVE with DD isolation was FS (P<0.001), followed by A (P=0.04), Pt (P<0.001), and RD and Pa (P<0.001). Counts produced from teeth prepared with DS isolation were significantly higher at the Pt location than the A (P<0.001), FS (P=0.002), RD (P<0.001), and Pa (P=0.008) locations. Conclusion: The use of dental dam with high-volume evacuation suction during stainless steel crown preparations increased bioaerosols near the procedure, while dental evacuation systems (DryShield®) may effectively limit their spread.


Subject(s)
Aerosols , Streptococcus mutans , Humans , Streptococcus mutans/isolation & purification , Stainless Steel , Crowns , In Vitro Techniques , Air Microbiology , Colony Count, Microbial , Biofilms , Bacterial Load , Suction/instrumentation , Infection Control, Dental/methods
2.
Arch Dermatol Res ; 316(7): 344, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38847979

ABSTRACT

Therapeutic options for acne scars include subcision and suction with microdermabrasion, but these treatment modalities have not been studied in conjunction. To compare effectiveness of subcision alone versus subcision with suction for the treatment of facial acne scars. Randomized, split-faced, evaluator-blinded control trial. Participants underwent one subcision treatment on both sides of the face followed by 10 sessions of suction to one side. Photographs at baseline, 1-month, and 4-months were assessed. Primary outcome measures were the validated Acne Scar Severity Scale (ASSS) (0 = no acne scarring, 4 = severe), Acne Scar Improvement Grading Scale (ASIGS) (-100 to 100%), and modified Quantitative Global Scarring Grades (QGSG) (point-based questionnaire instrument), as well as subject preference. Twenty-eight treatment areas and 154 treatments were analyzed. Dermatologist raters found no differences between subcision alone and subcision-suction at 1-month or 4-months. Mean subject-assessed percent improvement for subcision-suction was higher than that for subcision alone at 1-month (37% versus 24%, p = 0.04) but not at 4-months (p = 0.37). Subjects preferred combination therapy to monotherapy at 1-month (50% vs. 21%) and 4-months (43% vs. 21%). While blinded raters did not detect significant differences, subjects perceived combination treatment as working more quickly than monotherapy, and preferred combination treatment at all time points.Clinical trial registration NCT01696513 on Clinicaltrials.gov.


Subject(s)
Acne Vulgaris , Cicatrix , Humans , Acne Vulgaris/complications , Cicatrix/etiology , Cicatrix/diagnosis , Cicatrix/therapy , Female , Male , Adult , Suction/methods , Young Adult , Treatment Outcome , Adolescent , Severity of Illness Index , Combined Modality Therapy/methods , Single-Blind Method , Face
3.
Acta Chir Plast ; 66(1): 6-9, 2024.
Article in English | MEDLINE | ID: mdl-38704230

ABSTRACT

Breast reduction mammaplasty is the only effective therapeutic intervention for patients with symptomatic breast hypertrophy. In this procedure, closed suction drains have become a standard of care, while the literature supporting use of drains is lacking. In fact, with emerging data we found out that drains might not be so necessary. This review aimed to systematically compare the number of complications in drained and undrained breasts and to evaluate the safety of omitting drains in reduction mammaplasty in clinical practice. A systematic review of literature was conducted identifying all studies on drainage in reduction mammaplasty. The analysed databases revealed 13 eligible studies to be included in this review. There were 308 drained breasts and 859 undrained breasts in total in patients from 16 to 73 years of age. The resected tissue weight per side fluctuated from 108 to 1,296 grams. In total, there was only 2.4% incidence of haematoma complications in undrained breasts and 3.9% in drained breasts. Closed suction drains are still being routinely used in reduction mammaplasty, although aborting drain use is proven to be not only safe, but advantageous. The clear benefit is increased patient comfort, shortened hospital stay, decreased cost of the procedure and nurse care, and decreased rate of complications.


Subject(s)
Drainage , Mammaplasty , Humans , Mammaplasty/methods , Female , Drainage/instrumentation , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Suction , Breast/surgery , Middle Aged , Adult , Hypertrophy/surgery
4.
Vestn Oftalmol ; 140(2. Vyp. 2): 109-115, 2024.
Article in Russian | MEDLINE | ID: mdl-38739139

ABSTRACT

Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser. PURPOSE: This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation. MATERIAL AND METHODS: The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed. RESULTS: The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a "grid" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density. CONCLUSIONS: Femtosecond laser-assisted fragmentation of the lens nucleus with a "grid" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.


Subject(s)
Phacoemulsification , Humans , Adult , Male , Female , Phacoemulsification/methods , Laser Therapy/methods , Cataract , Treatment Outcome , Lens Nucleus, Crystalline/surgery , Suction/methods , Visual Acuity
5.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(4): 422-424, 2024 Apr.
Article in Chinese | MEDLINE | ID: mdl-38813639

ABSTRACT

Sputum suction is a necessary measure to remove respiratory secretions and collect sputum specimens, and the traditional sputum suction device includes open and closed methods. However, the open sputum suction device can easily cause sputum splashing during operation, polluting the operator and the surrounding environment. The closed sputum suction device is more expensive than the open sputum suction device. Although it can be used repeatedly, the friction between the protective sleeve and the wall of the suction tube increases after repeated uses, which in turn affects the operation. In addition, the two sputum suction methods need to be connected to a sputum collector when the sputum specimen is collected. This process can easily lead to leakage and contamination of specimens, and at the same time increase the infection risk for patients. In order to overcome the above problems, the medical staff from the department of critical care medicine of the First Affiliated Hospital of Dalian Medical University invented a new type of switchable semi-closed sputum suction device, and obtained the National Utility Model Patent of China (ZL 2020 2 1564712.3). The device is composed of a suction device connection port, a sliding negative pressure switch, an adapter interface, a pipe body, a transparent film protective sleeve, a clip-on connection joint, and a sputum collector. The sliding negative pressure switch at the connection port of the suction device can realize one-person one-handed operation. The sputum collector is connected with the sputum suction device to ensure that the specimen is not exposed. The transparent film protective sleeve covers the sputum suction tube body to ensure that the whole process of sputum suction operation is pollution-free. The clip-on connection joint is connected with the artificial airway interface to avoid sputum splashing during sputum suction, and it is clamped immediately after operation to reduce environmental pollution. Compared with the existing sputum suction device, the new switchable semi-closed sputum suction device has a more reasonable design and lower cost, which is worthy of clinical promotion.


Subject(s)
Equipment Design , Sputum , Suction/instrumentation , Humans
6.
J Hist Dent ; 72(1): 74-88, 2024.
Article in English | MEDLINE | ID: mdl-38642384

ABSTRACT

The modern theory of complete denture retention using suction was applied to wooden plate dentures in Japan from the first half of the 16th century, which is an astonishing achievement since it was clinically applied in North America and Europe in the latter half of the 19th century nearly 300 years later. Wooden dentures are unique to Japan resulting from skilled Japanese craftsmanship and are not found in other countries. We comprehensively reviewed reports on wooden plate dentures, analyzed 145 complete and partial dentures, and discussed their history. Japanese wooden plate dentures are mainly made of box wood, and artificial teeth are made of pagodite, ivory, and natural teeth. Small nails were driven into the molar region. Many existing dentures revealed attrition on the occlusal faces, thereby indicating that the wearers were able to masticate sufficiently. Wooden plate dentures have been used for 400 years in the early 20th century. Although Japanese wooden dentures have not been mentioned in the history of dentistry in Western literature, they comprise an important part of the history of denture development.


Subject(s)
Denture, Complete , Mouth, Edentulous , Humans , Japan , Suction , Denture, Partial
7.
PLoS One ; 19(4): e0300192, 2024.
Article in English | MEDLINE | ID: mdl-38578725

ABSTRACT

The current bag filter system used by railway ballast bed coal suction vehicles for cleaning coal dust from railway tunnels has low operational efficiency and generates significant volumes of dust. This paper describes a simulation test unit designed to enhance the dust removal performance in railway tunnels. The flow field inside the simulation test unit is investigated under different operating conditions through numerical simulations, and the variations in air volume and working resistance, total dust collection efficiency, and optimal operating parameters of a pulse cleaning system are identified through a series of experiments. The numerical results show that the pulse cleaning system does not significantly affect the uniformity of the flow field distribution at the bottom of the filter cartridge during the process of operation. The experimental research indicates that the simulation test unit satisfies the design requirements, achieving an average total dust removal efficiency of 99.93%. A field application shows that the total dust mass concentration at the operator position can be reduced from 335.8 mg∙m-3 to 4.2 mg∙m-3, effectively improving the operating environment within the tunnel.


Subject(s)
Coal Mining , Coal , Coal/analysis , Suction , Dust/analysis
8.
Ann Ital Chir ; 95(2): 213-219, 2024.
Article in English | MEDLINE | ID: mdl-38684490

ABSTRACT

BACKGROUND: Hydatid cyst of the liver induced by Echinococcus granulosus is a pervasive zoonotic disease in our region. Its incidence varies across age groups, contingent on community lifespans and hygiene standards. Therapeutic modalities include Puncture, Aspiration, Injection, Re-aspiration (PAIR), and surgery. Due the limited feasability of PAIR, we suggest that surgery represents the optimal treatment in all stages, especially in endemic regions, depending on patient-specific variables. METHOD: Patients with hydatid cyst of the liver treated with PAIR and surgery in our center between January 2016 and January 2022 were analyzed retrospectively. PAIR or cystectomy were applied in treatment. These were then compared in terms of efficacy, feasibility, and complications. RESULTS: A single hydatid cyst of the liver was detected in 184 of the 225 cases, two cysts in 33, and three or more cysts in eight. The largest cyst diameter was 233 × 124 mm in the surgery group and 100 × 90 mm in the PAIR group. One hundred thirty-three of the 225 patients underwent open surgery, and no recurrence was encountered in these. However, recurrence was observed 19 patients treated with PAIR. Allergic reaction developed in one case during surgery, postoperative abscess in two cases, biliary fistula in five, and pneumonia in one. CONCLUSION: Surgical treatment should represent the standard procedure since it is safe and effective, ensures complete elimination of the parasite, involves no intraoperative shedding, preserves healthy tissues, and minimizes the risk of long-term recurrence and cavity-related complications.


Subject(s)
Echinococcosis, Hepatic , Endemic Diseases , Humans , Echinococcosis, Hepatic/surgery , Echinococcosis, Hepatic/complications , Retrospective Studies , Male , Female , Adult , Middle Aged , Aged , Postoperative Complications/epidemiology , Young Adult , Adolescent , Recurrence , Suction , Treatment Outcome
9.
Proc Natl Acad Sci U S A ; 121(16): e2314359121, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38557166

ABSTRACT

Suction is a highly evolved biological adhesion strategy for soft-body organisms to achieve strong grasping on various objects. Biological suckers can adaptively attach to dry complex surfaces such as rocks and shells, which are extremely challenging for current artificial suction cups. Although the adaptive suction of biological suckers is believed to be the result of their soft body's mechanical deformation, some studies imply that in-sucker mucus secretion may be another critical factor in helping attach to complex surfaces, thanks to its high viscosity. Inspired by the combined action of biological suckers' soft bodies and mucus secretion, we propose a multiscale suction mechanism which successfully achieves strong adaptive suction on dry complex surfaces which are both highly curved and rough, such as a stone. The proposed multiscale suction mechanism is an organic combination of mechanical conformation and regulated water seal. Multilayer soft materials first generate a rough mechanical conformation to the substrate, reducing leaking apertures to micrometres (~10 µm). The remaining micron-sized apertures are then sealed by regulated water secretion from an artificial fluidic system based on the physical model, thereby the suction cup achieves long suction longevity on complex surfaces but minimal overflow. We discuss its physical principles and demonstrate its practical application as a robotic gripper on a wide range of complex dry surfaces. We believe the presented multiscale adaptive suction mechanism is a powerful unique adaptive suction strategy which may be instrumental in the development of versatile soft adhesion.


Subject(s)
Robotics , Water , Suction , Equipment Design
11.
AJNR Am J Neuroradiol ; 45(6): 727-730, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38575321

ABSTRACT

A novel swine model was developed to investigate the underlying reasons for the failure of aspiration thrombectomy. The model allows direct visualization of the target artery during thrombectomy in vessels of different sizes. The behavior of the target artery undergoing aspiration thrombectomy was recorded with high-resolution digital microscopy and fluoroscopic visualization, providing valuable insight into how the different sizes of treated arteries affect the effectiveness of mechanical thrombectomy.


Subject(s)
Thrombectomy , Animals , Swine , Thrombectomy/methods , Fluoroscopy , Disease Models, Animal , Suction/methods
12.
Anaesthesiologie ; 73(5): 340-347, 2024 May.
Article in German | MEDLINE | ID: mdl-38625537

ABSTRACT

BACKGROUND: Endotracheal suctioning in intubated or tracheotomized critically ill patients is a daily task of various professional groups in intensive and emergency medicine; however, a German language summary of current evidence is lacking. OBJECTIVE: The aim is to develop a narrative overview of current evidence on endotracheal suctioning of intubated or tracheotomized patients in the clinical setting. MATERIAL AND METHODS: A literature search was conducted in the databases Cinahl, Cochrane Library, Livivo, and Medline via PubMed by nurses with an academic degree. In addition, a hand search and applying the snowball principle were performed. Following a successful critical appraisal, all English and German language publications addressing endotracheal suctioning in the context of hospital care were included. RESULTS: A total of 23 full texts were included. After developing 6 main topics on endotracheal suction 19 articles were considered in the reporting. The results showed, among others, that routine deep suctioning once per shift is contraindicated and that the catheter should be advanced no more than 0.5-1 cm beyond the distal end of the tube or tracheal cannula. Closed suction catheters offer advantages, especially for staff protection, although studies are heterogeneous. Further training of staff is obligatory. CONCLUSION: Few conclusive studies on endotracheal suction could be found; however, with the available evidence initial conclusions can be drawn which should be considered in, for example, internal standard operating procedures. Further research is needed.


Subject(s)
Intubation, Intratracheal , Tracheotomy , Suction , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/methods , Humans , Tracheotomy/adverse effects , Tracheotomy/methods
13.
World J Urol ; 42(1): 257, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658395

ABSTRACT

PURPOSE: To assess the safety and efficacy of super-mini PCNL (SMP, 14 Fr) when compared to standard PCNL (sPCNL, 24-30 Fr) in the management of renal calculi of size ranging from 1.5 to 3 cm. METHODS: From February 2021 to January 2022, a total of 100 patients were randomized to either SMP group or sPCNL group in a 1:1 ratio (50 in each group) using computer-generated simple randomization. Demographic data, stone characteristics, operative times, perioperative complications, blood transfusions, postoperative drop in haemoglobin, postoperative pain, duration of hospital stay and stone-free rates were compared between the two groups. RESULTS: Mean stone volume (2.41 cm2 vs 2.61 cm2) and stone-free rates (98% vs 94%, p = 0.14) were similar in both the SMP and sPCNL groups, respectively. The SMP group had significantly longer mean operative times (51.62 ± 10.17 min vs 35.6 ± 6.8 min, p = 0.03). Intraoperative calyceal injury (1/50 vs 7/50, p = 0.42) and mean postoperative drop in haemoglobin (0.8 ± 0.7 g/dl vs 1.2 ± 0.81, p = 0.21) were lower in the SMP group, but not statistically significant. SMP group showed significantly lower mean postoperative pain VAS scores (5.4 ± 0.7 vs 5.9 ± 0.9, p = 0.03) and mean duration of hospital stay (28.38 ± 3.6 h vs 39.84 ± 3.7 h, p = 0.0001). Complications up to Clavien grade 2 were comparable, with grade ≥ 3 complications higher in the standard group, but not statistically significant. CONCLUSION: Super-mini PCNL is equally effective as standard PCNL in treating renal calculi up to 3 cm, with significantly reduced postoperative pain and duration of hospital stay and lower risk of Clavien grade ≥ 3 complications, although with higher operative times.


Subject(s)
Kidney Calculi , Nephrolithotomy, Percutaneous , Humans , Kidney Calculi/surgery , Male , Female , Middle Aged , Nephrolithotomy, Percutaneous/methods , Adult , Treatment Outcome , Suction/methods , Hospitals, University , Hospitals, Teaching , Nephrostomy, Percutaneous/methods
14.
Pediatr Dent ; 46(1): 58-62, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38449042

ABSTRACT

Purpose: Intraoral oxygen pooling during dental sedation, especially using supplemental oxygen, is associated with an increased risk of spontaneous perioperative fire. The purpose of this in vitro study was to examine the effectiveness of intraoral suctioning for reducing oxygen pooling to safe levels during a simulated dental procedure. Methods: Phase one: Twenty trials were completed for each of the three suctioning devices: high-volume evacuation (HVE), fixed tip saliva ejector (SE), and Yankauer suction (YS). Phase two: Twenty trials were completed for each of three suctioning scenarios: no suctioning and continuous suctioning for the HVE and SE. Results: In phase one, the slope for change (decrease) in oxygen during suction was significantly larger for SE than HVE (P<0.001) and YS (P<0.001), but for HVE and YS were not significantly different. Mean oxygen levels during suction were significantly higher for SE than HVE (P<0.001) and YS (P<0.001). In phase two, oxygen increased faster for no suction than for SE and HVE (P<0.001) and increased faster for SE than HVE (P<0.001). Mean oxygen levels were significantly lower for HVE than for SE (P<0.001) and no suction (P<0.001), and significantly lower for SE than no suction (P<0.001). Conclusion: All three devices were effective for reducing intraoral oxygen concentration to acceptable levels during the procedure. The HVE was the most effective suction device for rapidly evacuating pooled intraoral oxygen.


Subject(s)
Oral Surgical Procedures , Humans , Suction , Oxygen
15.
J Cardiothorac Surg ; 19(1): 157, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38539171

ABSTRACT

The minimally invasive extracorporeal circulation (MiECC) system was developed to minimize the contact of blood with air and foreign surfaces during conventional cardiopulmonary bypass (CPB). It is also aimed to reduce the inflammatory response by further increasing the biocompatibility of the components that make up the MiECC circuits. The Minithoracotomy (MTH) approach for mitral valve disease remains associated with prolonged operative times, but it is beneficial in terms of reduced postoperative complications (renal failure, atrial fibrillation, blood transfusion, wound infection), length of stay in intensive care unit (ICU) and in hospitalization, with finally a reduction in global cost. Combining the use of the MiECC technique with minimally invasive mitral valve surgery (MIMVS) could open up new research scenarios. Although considerable progress has been made in the standardization of the surgical technique, limitations remain to be filled in the setting of Endo-cavitary aspiration for the association of MiECC with MIMVS. In this paper we introduce invention refers to a device and an air-closed endocavitary aspiration system for cardiac chamber surgery, as well as a method aimed at eliminating gaseous micro-embolic activity, hemolysis and CO2 aspiration and alteration of carbon dioxide production (VCO2) the parameters for goal directed perfusion. The system allows the surgery of the cardiac chambers to be associated with a minimally invasive extra-corporeal circulation circuit.


Subject(s)
Cardiac Surgical Procedures , Mitral Valve , Humans , Mitral Valve/surgery , Suction , Treatment Outcome , Extracorporeal Circulation/methods , Cardiac Surgical Procedures/methods , Minimally Invasive Surgical Procedures/methods
16.
Ultrasonics ; 138: 107223, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38553135

ABSTRACT

Thrombotic occlusions of large blood vessels are increasingly treated with catheter based mechanical approaches, one of the most prominent being to employ aspiration to extract clots through a hollow catheter lumen. A central technical challenge for aspiration catheters is to achieve sufficient suction force to overcome the resistance of clot material entering into the distal tip. In this study, we examine the feasibility of inducing cavitation within hollow cylindrical transducers with a view to ultimately using them to degrade the mechanical integrity of thrombus within the tip of an aspiration catheter. Hollow cylindrical radially polarized PZT transducers with 3.3/2.5 mm outer/inner diameters were assessed. Finite element simulations and hydrophone experiments were used to investigate the pressure field distribution as a function of element length and resonant mode (thickness, length). Operating in thickness mode (∼5 MHz) was found to be associated with the highest internal pressures, estimated to exceed 23 MPa. Cavitation was demonstrated to be achievable within the transducer under degassed water (10 %) conditions using hydrophone detection and high-frequency ultrasound imaging (40 MHz). Cavitation clouds occupied a substantial portion of the transducer lumen, in a manner that was dependent on the pulsing scheme employed (10 and 100 µs pulse lengths; 1.1, 11, and 110 ms pulse intervals). Collectively the results support the feasibility of achieving cavitation within a transducer compatible with mounting in the tip of an aspiration format catheter.


Subject(s)
High-Intensity Focused Ultrasound Ablation , High-Intensity Focused Ultrasound Ablation/methods , Transducers , Suction , Catheters , Water
17.
Bioinspir Biomim ; 19(3)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38528733

ABSTRACT

Aquatic organisms utilizing attachment often contend with unpredictable environments that can dislodge them from substrates. To counter these forces, many organisms (e.g. fish, cephalopods) have evolved suction-based organs for adhesion. Morphology is diverse, with some disc shapes deviating from a circle to more ovate designs. Inspired by the diversity of multiple aquatic species, we investigated how bioinspired cups with different disc shapes performed in shear loading conditions. These experiments highlighted pertinent physical characteristics found in biological discs (regions of stiffness, flattened margins, a sealing rim), as well as ecologically relevant shearing conditions. Disc shapes of fabricated cups included a standard circle, ellipses, and other bioinspired designs. To consider the effects of sealing, these stiff silicone cups were produced with and without a soft rim. Cups were tested using a force-sensing robotic arm, which directionally sheared them across surfaces of varying roughness and compliance in wet conditions while measuring force. In multiple surface and shearing conditions, elliptical and teardrop shapes outperformed the circle, which suggests that disc shape and distribution of stiffness may play an important role in resisting shear. Additionally, incorporating a soft rim increased cup performance on rougher substrates, highlighting interactions between the cup materials and surfaces asperities. To better understand how these cup designs may resist shear, we also utilized a visualization technique (frustrated total internal reflection; FTIR) to quantify how contact area evolves as the cup is sheared.


Subject(s)
Cephalopoda , Fishes , Animals , Suction , Physical Phenomena
19.
Medicine (Baltimore) ; 103(11): e37412, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38489721

ABSTRACT

BACKGROUND: The value of prophylactic closed-suction drainage in totally extraperitoneal inguinal hernia repair (TEP) is still a matter of controversy. We conducted a meta-analysis of studies examining postoperative seroma rates in patients with or without routine placement of closed-suction drainage tubes. METHODS: A systematic literature search was conducted for trials comparing the outcome of TEP with or without routine drainage placement. Data regarding postoperative outcomes were extracted and compared by meta-analysis. The odds ratio and standardized mean differences with 95% confidence intervals were calculated. RESULTS: Four studies were identified, involving a total of 1626 cases (Drain: n = 1251, no Drain: n = 375). There was a statistically significant difference noted between the 2 groups regarding postoperative seroma formation favoring the Drain group (odds ratio = 0.12; 95% confidence intervals [0.05, 0.29]; P < .001; 4 studies; I2 = 72%). For the remaining secondary endpoints postoperative urinary retention, recurrence, mesh infection and in-hospital length of stay no statistically significant difference was noted between the 2 study groups. CONCLUSION: Current evidence suggests that patients who underwent TEP with routine closed-suction drain placement developed significantly fewer seromas without any additional morbidity or prolongation of in-hospital stay.


Subject(s)
Hernia, Inguinal , Laparoscopy , Humans , Suction , Hernia, Inguinal/surgery , Seroma/epidemiology , Seroma/etiology , Seroma/prevention & control , Herniorrhaphy/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Postoperative Complications/surgery , Pain, Postoperative/surgery , Surgical Mesh , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...