Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 128.077
Filter
1.
Carbohydr Polym ; 339: 122288, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38823936

ABSTRACT

This paper reports on biofunctionalisation of a poly(lactic acid) (PLA) film by surface activation through cold plasma treatment followed by coating with a chitosan-gelatin xerogel. The UV cross-linking of the xerogel precursor was simultaneously performed with the fixation onto the PLA support. This has a strong effect on surface properties, in terms of wettability, surface free energy, morphology and micromechanical features. The hydrophilic - hydrophobic character of the surface, determined by contact angle measurements, was tuned along the process, passing from moderate hydrophobic PLA to enhanced hydrophilic plasma activated surface, which favors coating adhesion, then to moderate hydrophobic chitosan-gelatin coating. The coating has a Lewis amphoteric surface, with a porous xerogel-like morphology, as revealed by scanning electron microscopy images. By riboflavin mediated UV cross-linking the chitosan-gelatin coating becomes high adhesive and with a more pronounced plasticity, as shown by AFM force-distance spectroscopy. Thus prepared surface-coated PLA supports were successfully tested for growth of dermal fibroblasts, which are known for their induction potential of chondrogenic cells, which is very important in cartilage tissue engineering.


Subject(s)
Chitosan , Fibroblasts , Gelatin , Polyesters , Chitosan/chemistry , Gelatin/chemistry , Polyesters/chemistry , Fibroblasts/drug effects , Fibroblasts/cytology , Humans , Surface Properties , Gels/chemistry , Ultraviolet Rays , Plasma Gases/chemistry , Hydrophobic and Hydrophilic Interactions , Coated Materials, Biocompatible/chemistry , Cross-Linking Reagents/chemistry , Wettability
2.
Med Sci Monit ; 30: e943353, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38825814

ABSTRACT

BACKGROUND Dentin contamination with hemostatic agents before bonding indirect restorations negatively affects the bond strength. However, the consensus on which materials could be used to clean contamination of hemostatic agents has not been explored. The aim of this study was to assess the effect of Katana Cleaner applied on the surface of dentin contaminated with hemostatic agents on the shear bond strength (SBS) of self-adhesive resin cement by comparing it with three other surface cleaners. MATERIAL AND METHODS Ninety dentin specimens were divided into a no contamination group (control) (n=10), 4 groups contaminated with 25% aluminum chloride (Viscostat Clear) (n=40), and 4 groups contaminated with 20% ferric sulfate (Viscostat) (n=40). Subsequently, 4 different cleaners were used for each contamination group (water rinse, phosphoric acid, chlorhexidine, and Katana Cleaner). Then, self-adhesive resin cement was directly bonded to the treated surfaces. All specimens were subjected to 5000 thermal cycles of artificial aging. The shear bond strength was measured using a universal testing machine. RESULTS Two-way analysis of variance showed that the contaminant type as the main factor was statistically non-significant (p=0.655), cleaner type as the main factor was highly significant (p<0.001), and interaction between the contaminant and cleaner was non-significant (p=0.51). The cleaner type was the main factor influencing the bond strength. Phosphoric acid and chlorhexidine showed better performance than Katana Cleaner. CONCLUSIONS Cleaning dentin surface contamination with phosphoric acid and chlorhexidine had better performance than with Katana Cleaner.


Subject(s)
Dental Bonding , Dentin , Hemostatics , Resin Cements , Shear Strength , Humans , Dentin/drug effects , Hemostatics/pharmacology , Dental Bonding/methods , Chlorhexidine/analogs & derivatives , Chlorhexidine/pharmacology , Materials Testing/methods , Surface Properties/drug effects , Dentin-Bonding Agents , Ferric Compounds/chemistry
4.
J Vis Exp ; (207)2024 May 17.
Article in English | MEDLINE | ID: mdl-38829127

ABSTRACT

In recent years, solution processes have gained considerable traction as a cost-effective and scalable method to produce high-performance thermoelectric materials. The process entails a series of critical steps: synthesis, purification, thermal treatments, and consolidation, each playing a pivotal role in determining performance, stability, and reproducibility. We have noticed a need for more comprehensive details for each of the described steps in most published works. Recognizing the significance of detailed synthetic protocols, we describe here the approach used to synthesize and characterize one of the highest-performing polycrystalline p-type SnSe. In particular, we report the synthesis of SnSe particles in water and the subsequent surface treatment with CdSe molecular complexes that yields CdSe-SnSe nanocomposites upon consolidation. Moreover, the surface treatment inhibits grain growth through Zenner pinning of secondary phase CdSe nanoparticles and enhances defect formation at different length scales. The enhanced complexity in the CdSe-SnSe nanocomposite microstructure with respect to SnSe promotes phonon scattering and thereby significantly reduces the thermal conductivity. Such surface engineering provides opportunities in solution processing for introducing and controlling defects, making it possible to optimize the transport properties and attain a high thermoelectric figure of merit.


Subject(s)
Cadmium Compounds , Selenium Compounds , Thermal Conductivity , Selenium Compounds/chemistry , Cadmium Compounds/chemistry , Tin/chemistry , Solutions/chemistry , Surface Properties , Crystallization/methods
5.
Int J Nanomedicine ; 19: 4835-4856, 2024.
Article in English | MEDLINE | ID: mdl-38828200

ABSTRACT

Metallic dental implants have been extensively used in clinical practice due to their superior mechanical properties, biocompatibility, and aesthetic outcomes. However, their integration with the surrounding soft tissue at the mucosal region remains challenging and can cause implant failure due to the peri-implant immune microenvironment. The soft tissue integration of dental implants can be ameliorated through different surface modifications. This review discussed and summarized the current knowledge of topography-mediated immune response and topography-mediated antibacterial activity in Ti dental implants which enhance soft tissue integration and their clinical performance. For example, nanopillar-like topographies such as spinules, and spikes showed effective antibacterial activity in human salivary biofilm which was due to the lethal stretching of bacterial membrane between the nanopillars. The key findings of this review were (I) cross-talk between surface nanotopography and soft tissue integration in which the surface nanotopography can guide the perpendicular orientation of collagen fibers into connective tissue which leads to the stability of soft tissue, (II) nanotubular array could shift the macrophage phenotype from pro-inflammatory (M1) to anti-inflammatory (M2) and manipulate the balance of osteogenesis/osteoclasia, and (III) surface nanotopography can provide specific sites for the loading of antibacterial agents and metallic nanoparticles of clinical interest functionalizing the implant surface. Silver-containing nanotubular topography significantly decreased the formation of fibrous encapsulation in per-implant soft tissue and showed synergistic antifungal and antibacterial properties. Although the Ti implants with surface nanotopography have shown promising in targeting soft tissue healing in vitro and in vivo through their immunomodulatory and antibacterial properties, however, long-term in vivo studies need to be conducted particularly in osteoporotic, and diabetic patients to ensure their desired performance with immunomodulatory and antibacterial properties. The optimization of product development is another challenging issue for its clinical translation, as the dental implant with surface nanotopography must endure implantation and operation inside the dental microenvironment. Finally, the sustainable release of metallic nanoparticles could be challenging to reduce cytotoxicity while augmenting the therapeutic effects.


Subject(s)
Anti-Bacterial Agents , Dental Implants , Surface Properties , Titanium , Titanium/chemistry , Titanium/pharmacology , Humans , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Metal Nanoparticles/chemistry , Animals , Biofilms/drug effects
6.
Sci Rep ; 14(1): 12721, 2024 06 03.
Article in English | MEDLINE | ID: mdl-38830871

ABSTRACT

Surface structure plays a crucial role in determining cell behavior on biomaterials, influencing cell adhesion, proliferation, differentiation, as well as immune cells and macrophage polarization. While grooves and ridges stimulate M2 polarization and pits and bumps promote M1 polarization, these structures do not accurately mimic the real bone surface. Consequently, the impact of mimicking bone surface topography on macrophage polarization remains unknown. Understanding the synergistic sequential roles of M1 and M2 macrophages in osteoimmunomodulation is crucial for effective bone tissue engineering. Thus, exploring the impact of bone surface microstructure mimicking biomaterials on macrophage polarization is critical. In this study, we aimed to sequentially activate M1 and M2 macrophages using Poly-L-Lactic acid (PLA) membranes with bone surface topographical features mimicked through the soft lithography technique. To mimic the bone surface topography, a bovine femur was used as a model surface, and the membranes were further modified with collagen type-I and hydroxyapatite to mimic the bone surface microenvironment. To determine the effect of these biomaterials on macrophage polarization, we conducted experimental analysis that contained estimating cytokine release profiles and characterizing cell morphology. Our results demonstrated the potential of the hydroxyapatite-deposited bone surface-mimicked PLA membranes to trigger sequential and synergistic M1 and M2 macrophage polarizations, suggesting their ability to achieve osteoimmunomodulatory macrophage polarization for bone tissue engineering applications. Although further experimental studies are required to completely investigate the osteoimmunomodulatory effects of these biomaterials, our results provide valuable insights into the potential advantages of biomaterials that mimic the complex microenvironment of bone surfaces.


Subject(s)
Macrophages , Polyesters , Surface Properties , Animals , Macrophages/metabolism , Macrophages/drug effects , Macrophages/immunology , Cattle , Polyesters/chemistry , Mice , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Tissue Engineering/methods , Durapatite/chemistry , Cytokines/metabolism , Bone and Bones/cytology , Cell Differentiation/drug effects , Macrophage Activation/drug effects , Cell Adhesion/drug effects , RAW 264.7 Cells , Cell Polarity/drug effects , Femur , Collagen Type I/metabolism
7.
Anal Chim Acta ; 1312: 342778, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834257

ABSTRACT

BACKGROUND: The technology of capturing circulating tumor cells (CTCs) plays a crucial role in the diagnosis, evaluation of therapeutic efficacy, and prediction of prognosis in lung cancer. However, the presence of complex blood environment often results in severe nonspecific protein adsorption and interferences from blood cells, which negatively impacts the specificity of CTCs capture. There is a great need for development of novel nanomaterials for CTCs capture with prominent anti-nonspecific adsorptions from proteins or blood cells. RESULTS: We present a novel immune magnetic probe Fe3O4@(PEI/AA)4@Apt. The surface of Fe3O4 particles was modified with four layers of PEI/AA composite by layer-by-layer assembly. Furthermore, aptamers targeting epithelial marker EpCAM (SYL3C) and mesenchymal marker CSV (ZY5C) were simultaneously connected on Fe3O4@(PEI/AA)4 to improve the detection of different phenotypic CTCs and reduce false negatives. The results demonstrated that the (PEI/AA)4 coatings not only minimized non-specific protein adsorptions, but also significantly reduced the adsorption rate of red blood cells to a mere 1 %, as a result of which, the Fe3O4@(PEI/AA)4@Apt probe achieved a remarkably high capture efficiency toward CTCs (95.9 %). In the subsequent validation of clinical samples, the probe was also effective in capturing rare CTCs from lung cancer patients. SIGNIFICANCE AND NOVELTY: A (PEI/AA) polymerized composite with controllable layers was fabricated by layer-by-layer self-assembly technique, which displayed remarkable anti-nonspecific adsorption capabilities toward proteins and cells. Importantly, Fe3O4@(PEI/AA)4@Apt probe significantly improved CTCs capture purity in lung cancer patients to 89.36 %. For the first time, this study combined controllable (PEI/AA) layers with magnetic separation to innovatively build a resistant interface that significantly improves the specific capture performances of CTCs, broadening the application of this polymerized composite.


Subject(s)
Alginates , Neoplastic Cells, Circulating , Polyethyleneimine , Humans , Neoplastic Cells, Circulating/pathology , Polyethyleneimine/chemistry , Alginates/chemistry , Magnetite Nanoparticles/chemistry , Lung Neoplasms/pathology , Aptamers, Nucleotide/chemistry , Adsorption , Surface Properties , Epithelial Cell Adhesion Molecule/immunology
8.
Anal Chim Acta ; 1312: 342767, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834270

ABSTRACT

BACKGROUND: Surface-enhanced Raman spectroscopy (SERS) has gained increasing importance in molecular detection due to its high specificity and sensitivity. Complex biofluids (e.g., cell lysates and serums) typically contain large numbers of different bio-molecules with various concentrations, making it extremely challenging to be reliably and comprehensively characterized via conventional single SERS spectra due to uncontrollable electromagnetic hot spots and irregular molecular motions. The traditional approach of directly reading out the single SERS spectra or calculating the average of multiple spectra is less likely to take advantage of the full information of complex biofluid systems. RESULTS: Herein, we propose to construct a spectral set with unordered multiple SERS spectra as a novel representation strategy to characterize full molecular information of complex biofluids. This new SERS representation not only contains details from each single spectra but captures the temporal/spatial distribution characteristics. To address the ordering-independent property of traditional chemometric methods (e.g., the Euclidean distance and the Pearson correlation coefficient), we introduce Wasserstein distance (WD) to quantitatively and comprehensively assess the quality of spectral sets on biofluids. WD performs its superiority for the quantitative assessment of the spectral sets. Additionally, WD benefits from its independence of the ordering of spectra in a spectral set, which is undesirable for traditional chemometric methods. With experiments on cell lysates and human serums, we successfully achieve the verification for the reproducibility between parallel samples, the uniformity at different positions in the same sample, the repeatability from multiple tests at one location of the same sample, and the cardinality effect of the spectral set. SERS spectral sets also manage to distinguish different classes of human serums and achieve higher accuracy than the traditional prostate-specific antigen in prostate cancer classification. SIGNIFICANCE: The proposed SERS spectral set is a robust representation approach in accessing full information of biological samples compared to relying on a single or averaged spectra in terms of reproducibility, uniformity, repeatability, and cardinality effect. The application of WD further demonstrates the effectiveness and robustness of spectral sets in characterizing complex biofluid samples, which extends and consolidates the role of SERS.


Subject(s)
Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Humans , Surface Properties , Metal Nanoparticles/chemistry , Male
9.
AAPS PharmSciTech ; 25(5): 126, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38834910

ABSTRACT

In the dynamic landscape of pharmaceutical advancements, the strategic application of active pharmaceutical ingredients to the skin through topical and transdermal routes has emerged as a compelling avenue for therapeutic interventions. This non-invasive approach has garnered considerable attention in recent decades, with numerous attempts yielding approaches and demonstrating substantial clinical potential. However, the formidable barrier function of the skin, mainly the confinement of drugs on the upper layers of the stratum corneum, poses a substantial hurdle, impeding successful drug delivery via this route. Ultradeformable vesicles/carriers (UDVs), positioned within the expansive realm of nanomedicine, have emerged as a promising tool for developing advanced dermal and transdermal therapies. The current review focuses on improving the passive dermal and transdermal targeting capacity by integrating functionalization groups by strategic surface modification of drug-loaded UDV nanocarriers. The present review discusses the details of case studies of different surface-modified UDVs with their bonding strategies and covers the recent patents and clinical trials. The design of surface modifications holds promise for overcoming existing challenges in drug delivery by marking a significant leap forward in the field of pharmaceutical sciences.


Subject(s)
Administration, Cutaneous , Drug Carriers , Drug Delivery Systems , Skin Absorption , Skin , Humans , Drug Delivery Systems/methods , Skin/metabolism , Skin Absorption/physiology , Skin Absorption/drug effects , Drug Carriers/chemistry , Animals , Nanoparticles/chemistry , Surface Properties , Pharmaceutical Preparations/administration & dosage , Pharmaceutical Preparations/chemistry , Nanomedicine/methods
10.
BMC Oral Health ; 24(1): 651, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831398

ABSTRACT

BACKGROUND: Carious/Non-carious cervical lesions with gingival recessions may require both dental and periodontal reconstructive therapy, where flaps/grafts may be placed in contact with a dental filling material. Human Gingival Fibroblasts (HGF-1) response during the early phase of healing could vary according to the procedures employed to cure the dental composite. Moreover, oxygen diffusion into dental composite inhibits the polymerization reaction, creating an oxygen-inhibited layer (OIL) that presents residual unreacted monomers. The aim of this study was to assess the effect of different polishing techniques and OIL on HGF-1. METHODS: Composite discs polished with different techniques (diamond rubber, abrasive discs and tungsten carbide burr) were used. An additional not polished smooth group obtained with and without OIL was used as control. Samples were physically characterized through the analysis of their hydrophilicity and surface topography through contact angle measurement and SEM, respectively; afterwards the biologic response of HGF-1 when cultured on the different substrates was analyzed in terms of cytotoxicity and gene expression. RESULTS: The finishing systems caused alterations to the wettability, even if without a proportional relation towards the results of the proliferation essay, from which emerges a greater proliferation on surfaces polished with one-step diamond rubber and with abrasive discs as well as a direct effect of the glycerin layer, confirming that surface roughness can heavily influence the biological response of HGF-1. CONCLUSIONS: Surfaces wettability as well as cellular behavior seem to be affected by the selection of the finishing system used to lastly shape the restoration. Especially, the presence of OIL act as a negative factor in the regards of human gingival fibroblasts. The present study may provide the first clinical instruction regarding the best polishing system of composite material when the restoration is placed directly in contact with soft tissue cells. Understanding HGF-1 behavior can help identifying the polishing treatment for direct restoration of carious/non-carious cervical lesions associated with gingival recessions.


Subject(s)
Composite Resins , Dental Polishing , Fibroblasts , Gingiva , Surface Properties , Humans , Gingiva/cytology , Dental Polishing/methods , Microscopy, Electron, Scanning , Cell Proliferation , Wettability , Dental Restoration, Permanent/methods , Tungsten Compounds/pharmacology , Cells, Cultured
11.
Int J Nanomedicine ; 19: 5011-5020, 2024.
Article in English | MEDLINE | ID: mdl-38832337

ABSTRACT

Purpose: Atomic layer deposition (ALD) is a method that can deposit zirconia uniformly on an atomic basis. The effect of deposited zirconia on titanium implants using ALD was evaluated in vivo. Methods: Machined titanium implants (MTIs) were used as the Control. MTIs treated by sandblasting with large grit and acid etching (SA) and MTIs deposited with zirconia using ALD are referred to as Groups S and Z, respectively. Twelve implants were prepared for each group. Six rabbits were used as experimental animals. To evaluate the osteogenesis and osteocyte aspects around the implants, radiological and histological analyses were performed. The bone-to-implant contact (BIC) ratio was measured and statistically analyzed to evaluate the osseointegration capabilities. Results: In the micro-CT analysis, more radiopaque bone tissues were observed around the implants in Groups S and Z. Histological observation found that Groups S and Z had more and denser mature bone tissues around the implants in the cortical bone area. Many new and mature bone tissues were also observed in the medullary cavity area. For the BIC ratio, Groups S and Z were significantly higher than the Control in the cortical bone area (P < 0.017), but there was no significant difference between Groups S and Z. Conclusion: MTIs deposited with zirconia using ALD (Group Z) radiologically and histologically showed more mature bone formation and activated osteocytes compared with MTIs (Control). Group Z also had a significantly higher BIC ratio than the Control. Within the limitations of this study, depositing zirconia on the surface of MTIs using ALD can improve osseointegration in vivo.


Subject(s)
Osseointegration , Titanium , Zirconium , Animals , Zirconium/chemistry , Zirconium/pharmacology , Rabbits , Titanium/chemistry , Titanium/pharmacology , Osseointegration/drug effects , Surface Properties , X-Ray Microtomography , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Bone-Implant Interface , Osteogenesis/drug effects , Dental Implants , Prostheses and Implants
12.
Clin Oral Investig ; 28(6): 355, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38833072

ABSTRACT

OBJECTIVES: Clinical trials testing new devices require prior training on dummies to minimize the "learning curve" for patients. Dentists were trained using a novel water jet device for mechanical cleaning of dental implants and with a novel cold plasma device for surface functionalisation during a simulated open flap peri-implantitis therapy. The hypothesis was that there would be a learning curve for both devices. MATERIALS AND METHODS: 11 dentists instrumented 44 implants in a dummy-fixed jaw model. The effect of the water jet treatment was assessed as stain removal and the effect of cold plasma treatment as surface wettability. Both results were analysed using photographs. To improve treatment skills, each dentist treated four implants and checked the results immediately after the treatment as feedback. RESULTS: Water jet treatment significantly improved from the first to the second implant from 62.7% to 75.3% stain removal, with no further improvement up to the fourth implant. The wettability with cold plasma application reached immediately a high level at the first implant and was unchanged to the 4th implant (mean scores 2.7 out of 3). CONCLUSION: A moderate learning curve was found for handling of the water jet but none for handling of the cold plasma. CLINICAL RELEVANCE: Scientific rational for study: Two new devices were developed for peri-implantitis treatment (Dental water jet, cold plasma). Dentists were trained in the use of these devices prior to the trial to minimize learning effects. PRINCIPAL FINDINGS: Experienced dentists learn the handling of the water jet very rapidly and for cold plasma they do not need much training. PRACTICAL IMPLICATIONS: A clinical study is in process. When the planned clinical study will be finished, we will find out, if this dummy head exercise really minimised the learning curve for these devices.


Subject(s)
Decontamination , Dental Implants , Plasma Gases , Water , Humans , Decontamination/methods , Peri-Implantitis/prevention & control , Surface Properties , Wettability
13.
PLoS One ; 19(6): e0303340, 2024.
Article in English | MEDLINE | ID: mdl-38829856

ABSTRACT

The subject matter of surfaces in computer aided geometric design (CAGD) is the depiction and design of surfaces in the computer graphics arena. Due to their geometric features, modeling of Bézier curves and surfaces with their shape parameters is the most well-liked topic of research in CAGD/computer-aided manufacturing (CAM). The primary challenges in industries such as automotive, shipbuilding, and aerospace are the design of complex surfaces. In order to address this issue, the continuity constraints between surfaces are utilized to generate complex surfaces. The parametric and geometric continuities are the two metrics commonly used for establishing connections among surfaces. This paper proposes continuity constraints between two generalized Bézier-like surfaces (gBS) with different shape parameters to address the issue of modeling and designing surfaces. Initially, the generalized form of C3 and G3 of generalized Bézier-like curves (gBC) are developed. To check the validity of these constraints, some numerical examples are also analyzed with graphical representations. Furthermore, for a continuous connection among these gBS, the necessary and sufficient G1 and G2 continuity constraints are also developed. It is shown through the use of several geometric designs of gBS that the recommended basis can resolve the shape and position adjustment problems associated with Bézier surfaces more effectively than any other basis. As a result, the proposed scheme not only incorporates all of the geometric features of curve design schemes but also improves upon their faults, which are typically encountered in engineering. Mainly, by changing the values of shape parameters, we can alter the shape of the curve by our choice which is not present in the standard Bézier model. This is the main drawback of traditional Bézier model.


Subject(s)
Models, Theoretical , Computer-Aided Design , Algorithms , Computer Simulation , Computer Graphics , Surface Properties
14.
Biointerphases ; 19(3)2024 May 01.
Article in English | MEDLINE | ID: mdl-38836787

ABSTRACT

Titanium (Ti) is widely utilized as an implant material; nonetheless, its integration with bone tissue faces limitations due to a patient's comorbidities. To address this challenge, we employed a strategic approach involving the growth of thin films by spin-coating and surface functionalization with etidronate (ETI), alendronate (ALE), and risedronate (RIS). Our methodology involved coating of Ti cp IV disks with thin films of TiO2, hydroxyapatite (HA), and their combinations (1:1 and 1:2 v/v), followed by surface functionalization with ETI, ALE, and RIS. Bisphosphonate-doped films were evaluated in terms of surface morphology and physical-chemical properties by techniques such as electron microscopy, confocal microscopy, and x-ray photoelectron spectroscopy. The antibacterial potential of bisphosphonates alone or functionalized onto the Ti surface was tested against Staphylococcus aureus biofilms. Primary human bone mesenchymal stem cells were used to determine in vitro cell metabolism and mineralization. Although RIS alone did not demonstrate any antibacterial effect as verified by minimum inhibitory concentration assay, when Ti surfaces were functionalized with RIS, partial inhibition of Staphylococcus aureus growth was noted, probably because of the physical-chemical surface properties. Furthermore, samples comprising TiO2/HA (1:1 and 1:2 v/v) showcased an enhancement in the metabolism of nondifferentiated cells and can potentially enhance the differentiation of osteoblastic precursors. All samples demonstrated cell viability higher than 80%. Addition of hydroxyapatite and presence of bisphosphonates increase the metabolic activity and the mineralization of human bone mesenchymal cells. While these findings hold promise, it is necessary to conduct further studies to evaluate the system's performance in vivo and ensure its long-term safety. This research marks a significant stride toward optimizing the efficacy of titanium implants through tailored surface modifications.


Subject(s)
Anti-Bacterial Agents , Diphosphonates , Mesenchymal Stem Cells , Microbial Sensitivity Tests , Staphylococcus aureus , Surface Properties , Titanium , Titanium/chemistry , Titanium/pharmacology , Humans , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Staphylococcus aureus/drug effects , Diphosphonates/chemistry , Diphosphonates/pharmacology , Mesenchymal Stem Cells/drug effects , Biofilms/drug effects , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Cells, Cultured , Durapatite/chemistry , Durapatite/pharmacology
15.
Molecules ; 29(9)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38731407

ABSTRACT

The problem of bacterial resistance has become more and more common with improvements in health care. Worryingly, the misuse of antibiotics leads to an increase in bacterial multidrug resistance and the development of new antibiotics has virtually stalled. These challenges have prompted the need to combat bacterial infections with the use of radically different approaches. Taking lessons from the exciting properties of micro-/nano-natural-patterned surfaces, which can destroy cellular integrity, the construction of artificial surfaces to mimic natural functions provides new opportunities for the innovation and development of biomedicine. Due to the diversity of natural surfaces, functional surfaces inspired by natural surfaces have a wide range of applications in healthcare. Nature-inspired surface structures have emerged as an effective and durable strategy to prevent bacterial infection, opening a new way to alleviate the problem of bacterial drug resistance. The present situation of bactericidal and antifouling surfaces with natural and biomimetic micro-/nano-structures is briefly reviewed. In addition, these innovative nature-inspired methods are used to manufacture a variety of artificial surfaces to achieve extraordinary antibacterial properties. In particular, the physical antibacterial effect of nature-inspired surfaces and the functional mechanisms of chemical groups, small molecules, and ions are discussed, as well as the wide current and future applications of artificial biomimetic micro-/nano-surfaces. Current challenges and future development directions are also discussed at the end. In the future, controlling the use of micro-/nano-structures and their subsequent functions will lead to biomimetic surfaces offering great potential applications in biomedicine.


Subject(s)
Anti-Bacterial Agents , Nanostructures , Surface Properties , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Nanostructures/chemistry , Biomimetic Materials/chemistry , Biomimetic Materials/pharmacology , Humans , Bacteria/drug effects , Bacterial Infections/drug therapy , Bacterial Infections/prevention & control
16.
ACS Appl Bio Mater ; 7(5): 3283-3294, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38727030

ABSTRACT

Medical implants are constantly facing the risk of bacterial infections, especially infections caused by multidrug resistant bacteria. To mitigate this problem, gold nanoparticles with alkyl bromide moieties (Au NPs-Br) on the surfaces were prepared. Xenon light irradiation triggered the plasmon effect of Au NPs-Br to induce free radical graft polymerization of 2-(dimethylamino)ethyl methacrylate (DMAEMA), leading to the formation of poly(DMAEMA) brush-grafted Au NPs (Au NPs-g-PDM). The Au NPs-g-PDM nanocomposites were conjugated with phytic acid (PA) via electrostatic interaction and van der Waals interaction. The as-formed aggregates were deposited on the titanium (Ti) substrates to form the PA/Au NPs-g-PDM (PAP) hybrid coatings through surface adherence of PA and the gravitational effect. Synergistic bactericidal effects of contact-killing caused by the cationic PDM brushes, and local heating generated by the Au NPs under near-infrared irradiation, conferred strong antibacterial effects on the PAP-deposited Ti (Ti-PAP) substrates. The synergistic bactericidal effects reduced the threshold temperature required for the photothermal sterilization, which in turn minimized the secondary damage to the implant site. The Ti-PAP substrates exhibited 97.34% and 99.97% antibacterial and antiadhesive efficacy, respectively, against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli), compared to the control under in vitro antimicrobial assays. Furthermore, the as-constructed Ti-PAP surface exhibited a 99.42% reduction in the inoculated S. aureus under in vivo assays. In addition, the PAP coatings exhibited good biocompatibility in the hemolysis and cytotoxicity assays as well as in the subcutaneous implantation of rats.


Subject(s)
Anti-Bacterial Agents , Escherichia coli , Gold , Materials Testing , Metal Nanoparticles , Microbial Sensitivity Tests , Particle Size , Phytic Acid , Staphylococcus aureus , Gold/chemistry , Gold/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/chemical synthesis , Metal Nanoparticles/chemistry , Phytic Acid/chemistry , Phytic Acid/pharmacology , Staphylococcus aureus/drug effects , Escherichia coli/drug effects , Animals , Surface Properties , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Cations/chemistry , Cations/pharmacology , Polymers/chemistry , Polymers/pharmacology , Titanium/chemistry , Titanium/pharmacology
17.
Sheng Wu Gong Cheng Xue Bao ; 40(5): 1448-1468, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38783808

ABSTRACT

Nanoparticles, as a novel material, have a wide range of applications in the food and biomedical fields. Nanoparticles spontaneously adsorb proteins in the biological environment, and tens or even hundreds of proteins can form protein corona on the surface of nanoparticles. The formation of protein corona on the surface of nanoparticles is one of the key factors affecting the stability, biocompatibility, targeting, and drug release properties of nanoparticles. The formation mechanism of protein corona is affected by a variety of factors, including the surface chemical properties, sizes, and shapes of nanoparticles and the types, concentrations, and pH of proteins. Studies have shown that the protein structure is associated with protein distribution on the nanoparticle surface, while the protein conformation affects the binding mode and stability of the protein on the nanoparticle surface. Since the mechanism of the formation of protein corona on the surface of nanoparticles is complex, the roles of multiple factors need to be considered comprehensively. Understanding the mechanisms and influencing factors of the formation of protein corona will help us to understand the process of protein corona formation and control the formation of protein corona for specific needs. In this paper, we summarize the recent studies on the mechanisms and influencing factors of the formation of protein corona on the surface of nanoparticles, with a view to providing a theoretical basis for in-depth research on protein corona.


Subject(s)
Nanoparticles , Protein Corona , Surface Properties , Protein Corona/chemistry , Protein Corona/metabolism , Nanoparticles/chemistry , Adsorption , Protein Conformation , Humans
18.
Food Chem ; 451: 139454, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38703725

ABSTRACT

Morphology regulation of heterodimer nanoparticles and the use of their asymmetric features for further practical applications are crucial because of the rich optical properties and various combinations of heterodimers. This work used silicon to asymmetrically wrap half of a gold sphere and grew gold branches on the bare gold surface to form heterogeneous nano pineapples (NPPs) which can effectively improve Surface-enhanced Raman scattering (SERS) properties through chemical enhancement and lightning-rod effect respectively. The asymmetric structures of NPPs enabled them to self-assemble into the monolayer membrane with consistent branch orientation. The prepared substrate had high homogeneity and better SERS ability than disorganized substrates, and achieved reliable detection of malachite green (MG) in clams with a detection limit of 7.8 × 10-11 M. This work provided a guide to further revise the morphology of heterodimers and a new idea for the use of asymmetric dimers for practically photochemical and biomedical sensing.


Subject(s)
Gold , Rosaniline Dyes , Silicon , Spectrum Analysis, Raman , Rosaniline Dyes/chemistry , Spectrum Analysis, Raman/methods , Gold/chemistry , Silicon/chemistry , Animals , Ananas/chemistry , Metal Nanoparticles/chemistry , Bivalvia/chemistry , Limit of Detection , Surface Properties
19.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745154

ABSTRACT

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Subject(s)
Alloys , Chlorhexidine , Dental Alloys , Microscopy, Electron, Scanning , Nickel , Orthodontic Wires , Sodium Fluoride , Surface Properties , Humans , Sodium Fluoride/therapeutic use , Chlorhexidine/therapeutic use , Corrosion , Dental Alloys/chemistry , Nickel/chemistry , Titanium/chemistry , Cariostatic Agents/therapeutic use , Cariostatic Agents/chemistry , Male , Female , Young Adult , Mouthwashes/therapeutic use , Mouthwashes/chemistry , Image Processing, Computer-Assisted/methods , Adolescent , Adult , Oral Hygiene
20.
Mil Med Res ; 11(1): 29, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741175

ABSTRACT

Peri-implantitis is a bacterial infection that causes soft tissue inflammatory lesions and alveolar bone resorption, ultimately resulting in implant failure. Dental implants for clinical use barely have antibacterial properties, and bacterial colonization and biofilm formation on the dental implants are major causes of peri-implantitis. Treatment strategies such as mechanical debridement and antibiotic therapy have been used to remove dental plaque. However, it is particularly important to prevent the occurrence of peri-implantitis rather than treatment. Therefore, the current research spot has focused on improving the antibacterial properties of dental implants, such as the construction of specific micro-nano surface texture, the introduction of diverse functional coatings, or the application of materials with intrinsic antibacterial properties. The aforementioned antibacterial surfaces can be incorporated with bioactive molecules, metallic nanoparticles, or other functional components to further enhance the osteogenic properties and accelerate the healing process. In this review, we summarize the recent developments in biomaterial science and the modification strategies applied to dental implants to inhibit biofilm formation and facilitate bone-implant integration. Furthermore, we summarized the obstacles existing in the process of laboratory research to reach the clinic products, and propose corresponding directions for future developments and research perspectives, so that to provide insights into the rational design and construction of dental implants with the aim to balance antibacterial efficacy, biological safety, and osteogenic property.


Subject(s)
Biocompatible Materials , Dental Implants , Peri-Implantitis , Peri-Implantitis/therapy , Peri-Implantitis/prevention & control , Peri-Implantitis/drug therapy , Humans , Dental Implants/standards , Biocompatible Materials/therapeutic use , Biocompatible Materials/pharmacology , Biofilms/drug effects , Surface Properties , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...