Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21.201
Filter
2.
Folia Med (Plovdiv) ; 66(2): 235-242, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38690819

ABSTRACT

INTRODUCTION: Tooth extraction is still one of the most common dental procedures, routinely performed for a variety of reasons. Tooth extraction forceps and elevators are well-known extraction instruments which have been the standard in tooth extraction procedures for well over a hundred years. Physics forceps are one possible alternative, aiming to perform less traumatic and more predictable extractions.


Subject(s)
Surgical Instruments , Tooth Extraction , Humans , Tooth Extraction/instrumentation , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Female , Male , Adult , Middle Aged , Young Adult , Aged
3.
Best Pract Res Clin Gastroenterol ; 69: 101900, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38749581

ABSTRACT

Despite the evolution in tools and techniques, perforation is still one of the most pernicious adverse events of therapeutic endoscopy with potentially huge consequences. As advanced endoscopic resection techniques are worldwide spreading, endoscopists must be ready to manage intraprocedural perforations. In fact, immediate endoscopic closure through a prompt diagnosis represents the first-line option, saving patients from surgery, long hospitalizations and worse outcomes. Traditional and novel endoscopic closure modalities, including clips, suturing devices, stents and vacuum therapy, are increasingly expanding the therapeutic armamentarium for closing these defects. Nevertheless, available literature on this topic is currently limited. In this review our goal is to give an overview on the management of perforations occurring during endoscopic resections, with particular attention to characteristics, advantages, disadvantages and new horizons of endoscopic closure tools.


Subject(s)
Intestinal Perforation , Humans , Intestinal Perforation/surgery , Intestinal Perforation/etiology , Suture Techniques/adverse effects , Stents , Surgical Instruments , Intraoperative Complications/etiology , Intraoperative Complications/therapy , Negative-Pressure Wound Therapy/adverse effects , Treatment Outcome
4.
Neurosciences (Riyadh) ; 29(2): 90-95, 2024 May.
Article in English | MEDLINE | ID: mdl-38740406

ABSTRACT

OBJECTIVES: To investigate the factors that contribute to the development of cerebral edema after aneurysm clipping in individuals with aneurysmal subarachnoid hemorrhage (aSAH). METHODS: A total of 232 patients with aSAH caused by rupture and treated with aneurysm clipping were included in the retrospective analysis of clinical data. Postoperatively, the participants were categorized into two groups based on the presence or absence of cerebral edema: a complication group (n=33) and a non-complication group (n=199).A comparison was made between the overall data of the 2 groups. RESULTS: In the complication group, there were higher proportions of patients experiencing recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, World Federation of Neurosurgical Societies (WFNS) grade II, Hunt-Hess grade III-IV, concomitant hypertension, duration from onset to operation ≥12 h, and concomitant hematoma compared to the non-complication group (p<0.05). Cerebral edema after aneurysm clipping was associated with several risk factors including repeated bleeding, aneurysm in the back of the brain, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, simultaneous high blood pressure and hematoma, and a duration of at least 12 hours from the start of symptoms to the surgical procedure (p<0.05). CONCLUSION: In patients with aSAH, the risk of cerebral edema after aneurysm clipping is increased by recurrent bleeding, aneurysm in the posterior circulation, Fisher grade III-IV, WFNS grade II, Hunt-Hess grade III-IV, concomitant hypertension and hematoma, and duration of ≥12 h from onset to operation.


Subject(s)
Brain Edema , Subarachnoid Hemorrhage , Humans , Subarachnoid Hemorrhage/surgery , Subarachnoid Hemorrhage/complications , Male , Female , Middle Aged , Brain Edema/etiology , Risk Factors , Retrospective Studies , Adult , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Intracranial Aneurysm/surgery , Intracranial Aneurysm/complications , Neurosurgical Procedures/adverse effects , Surgical Instruments/adverse effects , Aneurysm, Ruptured/surgery , Aneurysm, Ruptured/complications
7.
BMC Musculoskelet Disord ; 25(1): 373, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38730376

ABSTRACT

INTRODUCTION: An acute Achilles tendon rupture represents a common tendon injury, and its operative methods have been developed over the years. This study aimed to quantify the learning curve for the minimally invasive acute Achilles tendon rupture repair. METHODS: From May 2020 to June 2022, sixty-seven patient cases who received minimally invasive tendon repair were reviewed. Baseline data and operative details were collected. The cumulative summation (CUSUM) control chart was used for the learning curve analyses. Achilles tendon rupture score (ATRS), American Orthopedic Foot and Ankle Society (AOFAS) ankle/hindfoot score, and visual analog scale (VAS) at 3/6/9/12 months were calculated to assess the clinical outcomes. RESULTS: Thirty-six cases underwent at least a year of follow up and were enrolled in this study. The gender ratio and average age were 80.5% and 32.5 years. The linear equation fitted well (R2 = 0.95), and CUSUM for operative time peaked in the 12th case, which was divided into the learning phase (n = 12) and master phase (n = 24). No significant difference was detected between the two groups in clinical variables, except for the operative time (71.1 ± 13.2 min vs 45.8 ± 7.2 min, p = 0.004). Moreover, we detected one case with a suture reaction and treated it properly. CONCLUSION: Minimally invasive Achilles repair provides an opportunity for early rehabilitation. Notably, the learning curve showed that the "lumbar puncture needle and oval forceps" technique was accessible to surgeons.


Subject(s)
Achilles Tendon , Learning Curve , Minimally Invasive Surgical Procedures , Tendon Injuries , Humans , Achilles Tendon/surgery , Achilles Tendon/injuries , Male , Female , Adult , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/education , Minimally Invasive Surgical Procedures/instrumentation , Middle Aged , Tendon Injuries/surgery , Rupture/surgery , Retrospective Studies , Treatment Outcome , Surgical Instruments , Needles , Operative Time
8.
Clin Neurol Neurosurg ; 241: 108304, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38718706

ABSTRACT

OBJECTIVE: Tubular retractors are increasingly used due to their low complication rates, providing easier access to lesions while minimizing trauma from brain retraction. Our study presents the most extensive series of cases performed by a single surgeon aiming to assess the effectiveness and safety of a transcortical-transtubular approach for removing intracranial lesions. METHODS: We performed a retrospective review of patients who underwent resection of an intracranial lesion with the use of tubular retractors. Electronic medical records were reviewed for patient demographics, preoperative clinical deficits, diagnosis, preoperative and postoperative magnetic resonance imaging (MRI) scans, lesion characteristics including location, volume, extent of resection (EOR), postoperative complications, and postoperative deficits. RESULTS: 112 transtubular resections for intracranial lesions were performed. Patients presented with a diverse number of pathologies including metastasis (31.3 %), GBM (21.4 %), and colloid cysts (19.6 %) The mean pre-op lesion volume was 14.45 cm3. A gross total resection was achieved in 81 (71.7 %) cases. Seventeen (15.2 %) patients experienced early complications which included confusion, short-term memory difficulties, seizures, meningitis and motor and visual deficits. Four (3.6 %) patients had permanent complications, including one with aphasia and difficulty finding words, another with memory loss, a third with left-sided weakness, and one patient who developed new-onset long-term seizures. Mean post-operative hospitalization length was 3.8 days. CONCLUSION: Tubular retractors provide a minimally invasive approach for the extraction of intracranial lesions. They serve as an efficient tool in neurosurgery, facilitating the safe resection of deep-seated lesions with minimal complications.


Subject(s)
Brain Neoplasms , Minimally Invasive Surgical Procedures , Neurosurgical Procedures , Postoperative Complications , Humans , Male , Female , Middle Aged , Adult , Brain Neoplasms/surgery , Brain Neoplasms/diagnostic imaging , Aged , Retrospective Studies , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Neurosurgical Procedures/methods , Postoperative Complications/epidemiology , Young Adult , Aged, 80 and over , Treatment Outcome , Adolescent , Surgical Instruments , Magnetic Resonance Imaging
9.
PLoS One ; 19(5): e0302737, 2024.
Article in English | MEDLINE | ID: mdl-38696516

ABSTRACT

BACKGROUND: As advancements in surgical instruments and techniques continue to evolve, minimally invasive surgery has become increasingly preferred as a means of reducing patient pain and recovery time. However, one major challenge in performing minimally invasive surgery for early gastrointestinal cancer is accurately identifying the location of the lesion. This is particularly difficult when the lesion is confined to the lumen of the intestine and cannot be visually confirmed from the outside during surgery. In such cases, surgeons must rely on CT or endoscopic imaging to locate the lesion. However, if the lesion is difficult to identify with these images or if the surgeon has less experience, it can be challenging to determine its precise location. This can result in an excessive resection margin, deviating from the goal of minimally invasive surgery. To address this challenge, researchers have been studying the development of a marker for identifying the lesion using a radio-frequency identification (RFID) system. One proposed method for clinical application of this detection system is to attach an RFID tag to an endoscopic hemostatic clip and fix it to the intended position, providing a stable marker for the inner wall of the organ. This approach has the potential to improve the accuracy and effectiveness of minimally invasive surgery for early gastrointestinal cancer. METHODS: In the development of a marker for identifying gastrointestinal lesions using a radio-frequency identification (RFID) system, the shape of the clip and suitable materials for attaching the RFID tag were determined through finite element method (FEM) analysis. A prototype of the clip was then fabricated and ex-vivo experiments were conducted using porcine intestine to evaluate the stability of the clip in relation to its position. To further evaluate the performance of the RFID-integrated clip in vivo, the clip was placed in the gastric wall of the stomach of anesthetized porcine using an endoscopic instrument. The clip was then detected using a RFID detector designed for laparoscopic approach. And later, the accuracy of detection was confirmed by incising the lesion. RESULTS: The design and fabrication of a clip with varying thicknesses using STS316 and STS304 stainless steel were accomplished using the results of finite element method analysis. The stability of the clip was evaluated through ex-vivo experiments, showing it to be a viable option. In-vivo experiments were performed on anesthetized porcine, in which the RFID-integrated clip was placed in the gastric wall and detected using a custom-made RFID detector. The resection margin, measured at about 30 mm from the detector position, was accomplished with low error. These findings indicate the feasibility and efficacy of using an RFID-integrated clip as a marker in minimally invasive surgery for the identification of gastrointestinal lesions. CONCLUSIONS: The study evaluated the feasibility of using stainless steel clips for lesion detection in endoscopic surgery using computer-aided engineering analysis and ex-vivo experimentation. Results showed that STS304 was suitable for use while STS316L was not. The ex-vivo experiments revealed that the clip holding force and tissue retention length varied depending on the location of attachment. In-vivo experiments confirmed the accuracy and usefulness of the RFID lesion detection system. However, challenges remain for its use in clinical field, such as ensuring the stability of the clip and the safe attachment of the RFID tag, which requires further research for commercialization.


Subject(s)
Laparoscopy , Surgical Instruments , Laparoscopy/methods , Laparoscopy/instrumentation , Animals , Swine , Radio Frequency Identification Device/methods , Humans
10.
Prog Brain Res ; 285: 115-126, 2024.
Article in English | MEDLINE | ID: mdl-38705711

ABSTRACT

The only instruments for opening the cranium considered in this chapter are drills, and in some cases facilitated with a special chisel called a lenticular. There were two kinds of trepan. The modiolus was the Latin name for a crown trepan which had a circular base with teeth which sawed a hole. Then there were the non-penetrating trepans which had a bit shaped to prevent unwanted penetration. They made small openings which could be joined by chisels to remove altogether larger areas of bone than were accessible to modioli. They were the favored instrument from the ancient world up to the Renaissance. At the beginning of the Renaissance, there was a move toward greater use of crown trepans and various methods were applied to stop them sinking too far inward. These included wings in the outer wall and changing the shape of the bit from cylindrical to conic. In time preferences returned to the cylindrical shape and larger diameters. There was also two instruments called lenticulars, the illustrations of which have been confused in the literature. It is now clear that the Roman instrument was shaped to cut the cranium and minimize the need for trepanation. The Renaissance instrument had a different shape and was used to smooth rough bone edges and excise spicules penetrating the meninges. They were simply two different instruments to which the same name was applied.


Subject(s)
Surgical Instruments , Surgical Instruments/history , History, Ancient , Humans , History, Medieval , History, 16th Century , History, 15th Century , Skull/anatomy & histology , Trephining/history , Trephining/instrumentation
11.
Int J Med Robot ; 20(3): e2640, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38794828

ABSTRACT

BACKGROUND: Accurately estimating the 6D pose of snake-like wrist-type surgical instruments is challenging due to their complex kinematics and flexible design. METHODS: We propose ERegPose, a comprehensive strategy for precise 6D pose estimation. The strategy consists of two components: ERegPoseNet, an original deep neural network model designed for explicit regression of the instrument's 6D pose, and an annotated in-house dataset of simulated surgical operations. To capture rotational features, we employ an Single Shot multibox Detector (SSD)-like detector to generate bounding boxes of the instrument tip. RESULTS: ERegPoseNet achieves an error of 1.056 mm in 3D translation, 0.073 rad in 3D rotation, and an average distance (ADD) metric of 3.974 mm, indicating an overall spatial transformation error. The necessity of the SSD-like detector and L1 loss is validated through experiments. CONCLUSIONS: ERegPose outperforms existing approaches, providing accurate 6D pose estimation for snake-like wrist-type surgical instruments. Its practical applications in various surgical tasks hold great promise.


Subject(s)
Neural Networks, Computer , Surgical Instruments , Wrist , Humans , Wrist/surgery , Equipment Design , Biomechanical Phenomena , Algorithms , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Imaging, Three-Dimensional/methods , Rotation , Reproducibility of Results , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods , Regression Analysis
12.
PLoS One ; 19(5): e0292207, 2024.
Article in English | MEDLINE | ID: mdl-38787830

ABSTRACT

BACKGROUND: Speculum lubrication may help to reduce the pain experienced during Pap-smear collection and hence increase uptake of cervical cancer screening and repeat testing, but there are fears of its interference with cytological results. AIM: To determine and compare the adequacy of cervical cytology smears and the mean pain scores of women undergoing cervical cancer screening with or without speculum lubrication. METHODS: This was a randomised controlled study of 132 women having cervical cancer screening at a tertiary hospital in Nigeria. Sixty-six participants were randomly assigned to the 'Gel' and 'No Gel' groups, respectively. Pap smears were collected from each participant with a lubricated speculum ('Gel group') or a non-lubricated speculum ('No Gel group'). The primary outcome measures were the proportion of women with unsatisfactory cervical cytology smears and the mean numeric rating scale pain scores, while the secondary outcome measures were the proportion of women who were willing to come for repeat testing and the cytological diagnosis of Pap-smear results. RESULTS: The baseline socio-demographic variables were similar in both groups. There was no significant difference in the proportion of unsatisfactory cervical smear results between the two groups (13.6% vs. 21.2%, p = 0.359). However, the mean pain scores were significantly lower in the gel group than in the no gel group (45.04 vs. 87.96; p<0.001). An equal proportion of the participants in each group (90.9% vs. 90.9%; p > 0.999) were willing to come for repeat cervical smears in the future. CONCLUSION: Speculum lubrication did not affect the adequacy of cervical smears but significantly reduced the pain experienced during pap smear collection. Also, it did not significantly affect the willingness to come for repeat cervical smears in the future. TRIAL REGISTRATION: The trial was registered with the Pan-African Clinical Trial Registry with a unique identification and registration number: PACTR2020077533364675.


Subject(s)
Early Detection of Cancer , Lubrication , Papanicolaou Test , Uterine Cervical Neoplasms , Vaginal Smears , Humans , Female , Uterine Cervical Neoplasms/diagnosis , Vaginal Smears/methods , Adult , Early Detection of Cancer/methods , Middle Aged , Double-Blind Method , Surgical Instruments
13.
Prog Brain Res ; 285: 157-178, 2024.
Article in English | MEDLINE | ID: mdl-38705715

ABSTRACT

The chapter begins with also an outline of the characteristics of four surgeons who changed the direction of thinking and hence of practice. This is followed by a review of the changing ideas which governed surgical practice. Chapter "Two surgical instruments" by Jeremy C. Ganz has examined the uses of drills and lenticulars. In this chapter there is an appraisal of the other instruments used during cranial surgery and how their use related to changing ideas. Finally, there is a concluding section which ties all these elements together.


Subject(s)
Surgical Instruments , Humans , History, 20th Century , History, 19th Century , Neurosurgery , Neurosurgical Procedures
16.
Turk Neurosurg ; 34(3): 377-387, 2024.
Article in English | MEDLINE | ID: mdl-38650551

ABSTRACT

AIM: To compare endovascular coiling and surgical clipping for the evaluation of clinical outcomes in patients with unruptured intracranial aneurysms. MATERIAL AND METHODS: We searched MEDLINE, EMBASE, the Cochrane Library and three Chinese domestic electronic databases, namely, Wanfang, CNKI and VIP for studies published between January 1990 and January 2018. We included controlled clinical studies comparing clinical outcomes between surgical clipping and endovascular coiling treatments. Two researchers extracted the data and assessed the quality of the studies, and a meta-analysis was performed using RevMan 5 software. RESULTS: We analysed a total of 23 controlled clinical studies including 117,796 cases. Meta-analysis demonstrated similar ischaemia rates between clipping and coiling with an odds ratio [OR] of 1.36 (95% CI: 0.77?2.40). The occlusion rate and bleeding risk were higher with clipping than coiling; the pooled ORs were 5.31 (95% CI: 3.07?9.19) and 2.39 (95% CI: 1.82?3.13), respectively. In addition, clipping resulted in a longer hospital stay (OR = 2.90, 95% CI: 2.14?3.65) than coiling did. Patients who underwent clipping had a higher short-term mortality (OR = 1.99, 95% CI: 1.70?2.33) and neurological deficit rate (OR = 2.05, 95% CI: 1.73? 2.44) compared with those who underwent coiling. However, 1 year mortality and deficit rate were similar for both clipping and coiling, with pooled ORs of 0.75 (95% CI: 0.41?1.38) and 0.94 (95% CI: 0.53?1.67), respectively. Funnel plots did not demonstrate a publication bias, with the exception of ischaemic outcome, and sensitivity analysis showed consistent results. CONCLUSION: Our study demonstrates that coiling is associated with a lower rate of occlusion, shorter hospital stay, lower bleeding risk and lower short-term mortality and morbidity compared with clipping. In terms of ischaemic risk, 1 year mortality and morbidity, coiling and clipping bear a similar risk. In addition, we speculate that surgical clipping may have a better outcome than endovascular coiling in the long term especially in young patients. Further research is needed to confirm our conclusion.


Subject(s)
Endovascular Procedures , Intracranial Aneurysm , Surgical Instruments , Humans , Intracranial Aneurysm/surgery , Intracranial Aneurysm/therapy , Endovascular Procedures/methods , Treatment Outcome , Neurosurgical Procedures/methods , Embolization, Therapeutic/methods , Embolization, Therapeutic/instrumentation
17.
Neurol Med Chir (Tokyo) ; 64(5): 175-183, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38569917

ABSTRACT

This study aimed to introduce a three-dimensional (3D) images fusion method for preoperative simulation of aneurysm clipping. Consecutive unruptured aneurysm cases treated with surgical clipping from March 2021 to October 2023 were included. In all cases, preoperative images of plain computed tomography (CT), CT angiography, magnetic resonance imaging (MRI) 3D fluid-attenuated inversion recovery, 3D heavily T2-weighted images, and 3D rotational angiography were acquired and transported into a commercial software (Ziostation2 Plus, Ziosoft, Inc. Tokyo, Japan). The software provided 3D images of skull, arteries including aneurysms, veins, and brain tissue that were freely rotated, magnified, trimmed, and superimposed. Using the 3D images fusion method, two operators predicted clips to be used in the following surgery. The predicted clips and actually used ones were compared to give agreement scores for the following factors: (1) type of clips (simple or fenestrated), (2) shape of clips (straight, curved, angled, or bayonet), and (3) clipping strategy (single or multiple). The agreement score ranged from 0 to 3 because a score of 1 or 0 was given for agreement or disagreement on each factor. Interoperator reproducibility was also evaluated. During the study period, 44 aneurysms from 37 patients were clipped. All procedures were successfully completed, thanks to the precisely reproduced surgical corridors with the 3D images fusion method. Agreement in clip prediction was good with mean agreement score of 2.4. Interobserver reproducibility was also high with the kappa value of 0.79. The 3D images fusion method was useful for preoperative simulation of aneurysm clipping.


Subject(s)
Imaging, Three-Dimensional , Intracranial Aneurysm , Surgical Instruments , Humans , Intracranial Aneurysm/surgery , Intracranial Aneurysm/diagnostic imaging , Female , Male , Middle Aged , Aged , Adult , Preoperative Care/methods , Neurosurgical Procedures/methods , Cerebral Angiography/methods , Magnetic Resonance Imaging/methods
18.
Am J Cardiol ; 220: 39-46, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583697

ABSTRACT

This study evaluated the nationwide associations between concomitant left atrial appendage clip (LAAC) placement during cardiac surgery and postoperative outcomes. We identified 1,260,999 patients who underwent coronary artery bypass grafting, valve, and aortic surgeries in the 2016 to 2020 Nationwide Readmissions Database and stratified by concomitant LAAC versus no LAAC placement. Patients who underwent surgical ablation were excluded. Mortality and complications were compared during index admissions and for patients readmitted within 30 and 90 days of the index discharge date for unmatched and propensity score-matched groups. Overall, 6.7% (84,293) of patients underwent cardiac surgery and concomitant LAAC placement without surgical ablation. After propensity score matching, the index admission mortality and overall complications were not different in patients with LAAC versus patients without LAAC. LAAC placement was associated with increased any-cause 30-day readmissions (15% vs 13%, p <0.01). In patients with LAAC, within 30 days, there were no differences in mortality (3.9% vs 3.8%, p = 0.60) or overall complications (64% vs 63%, p = 0.20), whereas stroke was lower (5.3% vs 6.5%, p <0.01) and heart failure was higher (35% vs 30%, p <0.01). For patients readmitted within 90 days, similar findings were observed for any-cause readmissions, mortality, overall complications, stroke, and heart failure. In conclusion, concomitant LAAC placement during cardiac surgery was associated with lower early postdischarge incidence of stroke and a favorable overall risk-benefit profile. Given these short-term findings in a real-world population of all patients who underwent cardiac surgery, longer-term studies with more granular data are needed to evaluate the potential benefit of this practice.


Subject(s)
Atrial Appendage , Cardiac Surgical Procedures , Patient Readmission , Postoperative Complications , Humans , Atrial Appendage/surgery , Male , Female , Aged , Cardiac Surgical Procedures/methods , Postoperative Complications/epidemiology , Middle Aged , Patient Readmission/statistics & numerical data , United States/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Propensity Score , Stroke/epidemiology , Stroke/etiology , Surgical Instruments , Coronary Artery Bypass/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...