1.
Sci Rep ; 14(1): 10055, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38698058

ABSTRACT

Endoscopic transgastric necrosectomy is crucial in the management of complications resulting from necrotizing pancreatitis. However, both real-time and visual-spatial information is lacking during the procedure, thereby jeopardizing a precise positioning of the endoscope. We conducted a proof-of-concept study with the aim of overcoming these technical difficulties. For this purpose, a three-dimensional (3D) phantom of a stomach and pancreatic necroses was 3D-printed based on spatial information from individual patient CT scans and subsequently integrated into a silicone torso. An electromagnetic (EM) sensor was adjusted inside the endoscope´s working channel. A software interface enabled real time visualization. The accuracy of this novel assistant system was tested ex vivo by four experienced interventional endoscopists who were supposed to reach seven targets inside the phantom in six different experimental runs of simulated endoscopic transgastric necrosectomy. Supported by endoscopic camera view combined with real-time 3D visualization, all endoscopists reached the targets with a targeting error ranging between 2.6 and 6.5 mm in a maximum of eight minutes. In summary, the EM tracking system might increase efficacy and safety of endoscopic transgastric necrosectomy at the experimental level by enhancing visualization. Yet, a broader feasibility study and further technical improvements are mandatory before aiming at implementation into clinical setting.


Subject(s)
Electromagnetic Phenomena , Humans , Phantoms, Imaging , Stomach/surgery , Stomach/diagnostic imaging , Pancreatitis, Acute Necrotizing/surgery , Pancreatitis, Acute Necrotizing/diagnostic imaging , Endoscopy/methods , Pancreas/surgery , Printing, Three-Dimensional , Surgical Navigation Systems , Imaging, Three-Dimensional/methods
2.
BMC Oral Health ; 24(1): 596, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778269

ABSTRACT

BACKGROUND: Dynamic navigation for implant placement is becoming popular under the concept of top-down treatment. The purpose of this study is to verify the accuracy of a dynamic navigation system for implant placement. METHODS: Implant placement was performed on 38 patients using 50 implant fixtures. Patients in group C were treated using a conventional method, in which thermoplastic clips were fixed to the teeth, and patients in group M were treated using thermoplastic clips fixed to a mouthpiece attached to the teeth. The groups were compared to verify whether an accuracy difference existed. A treatment planning support program for dental implants was used to superimpose the postoperative computed tomography data on the preoperative implant design data to measure the entry point, apex point, and angular deviation. RESULTS: The accuracy of group C was 1.36 ± 0.51 mm for entry point, 1.30 ± 0.59 mm for apex point, and 3.20 ± 0.74° for angular deviation. The accuracy of group M was 1.06 ± 0.31 mm for the entry point, 1.02 ± 0.30 mm for the apex point, and 2.91 ± 0.97° for angular deviation. Significant differences were observed in the entry and apex points between the two groups. CONCLUSIONS: The results indicate that group M exhibited better accuracy than group C, indicating that the stability of the thermoplastic clip is important for ensuring the accuracy of the dynamic navigation system. No previous studies have verified the accuracy of this system using the mouthpiece method, and additional data is required to confirm its accuracy for dental implant placement. The mouthpiece method improves the accuracy of implant placement and provides a safer implant treatment than the conventional method. TRIAL REGISTRATION: University hospital Medical Information Network Clinical Trials Registry (UMIN-CTR), Registration Number: UMIN000051949, URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view_his.cgi on August 21, 2023.


Subject(s)
Dental Implantation, Endosseous , Humans , Male , Female , Dental Implantation, Endosseous/methods , Middle Aged , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed , Surgical Navigation Systems , Adult , Dental Implants , Aged , Patient Care Planning
3.
BMC Oral Health ; 24(1): 582, 2024 May 19.
Article in English | MEDLINE | ID: mdl-38764019

ABSTRACT

BACKGROUND: The operation accuracy and efficiency of dynamic navigated endodontic surgery were evaluated through in vitro experiments. This study provides a reference for future clinical application of dynamic navigation systems in endodontic surgery. MATERIALS AND METHODS: 3D-printed maxillary anterior teeth were used in the preparation of models for endodontic surgery. Endodontic surgery was performed with and without dynamic navigation by an operator who was proficient in dynamic navigation technology but had no experience in endodontic surgery. Optical scanning data were applied to evaluate the length and angle deviations of root-end resection. And the operation time was recorded. T tests were used to analyze the effect of dynamic navigation technology on the accuracy and duration of endodontic surgery. RESULTS: With dynamic navigation, the root-end resection length deviation was 0.46 ± 0.06 mm, the angle deviation was 2.45 ± 0.96°, and the operation time was 187 ± 22.97 s. Without dynamic navigation, the root-end resection length deviation was 1.20 ± 0.92 mm, the angle deviation was 16.20 ± 9.59°, and the operation time was 247 ± 61.47 s. Less deviation was achieved and less operation time was spent with than without dynamic navigation (P < 0.01). CONCLUSION: The application of a dynamic navigation system in endodontic surgery can improve the accuracy and efficiency significantly for operators without surgical experience and reduce the operation time.


Subject(s)
Printing, Three-Dimensional , Humans , Pilot Projects , In Vitro Techniques , Surgery, Computer-Assisted/methods , Apicoectomy/methods , Operative Time , Surgical Navigation Systems
4.
Arch Orthop Trauma Surg ; 144(5): 2429-2435, 2024 May.
Article in English | MEDLINE | ID: mdl-38661997

ABSTRACT

INTRODUCTION: Correct cup placement in total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH) is considerably difficult. This study aimed to analyze the orientation accuracy of cup insertion during THA using a portable navigation system in patients with DDH. MATERIALS AND METHODS: In this retrospective cohort study, we analyzed data from 64 patients who underwent THA using infrared stereo camera-matching portable navigation. Patients underwent THA via the anterolateral approach in the lateral decubitus position. Navigation records for intraoperative cup angles, postoperative cup angles measured on computed tomography (CT) images, and cup angle measurement differences were measured and compared between patients with non-DDH/mild DDH and severe DDH. Furthermore, the predictive factors for outliers of accurate acetabular cup placement were analyzed. RESULTS: The average measurement absolute abduction differences (postoperative CT-navigation record) were 3.9 ± 3.5° (severe DDH) and 3.3 ± 2.6° (non-DDH/ mild DDH), and the anteversion differences were 4.7 ± 3.4° (severe DDH) and 2.3 ± 2.1° (non-DDH/ mild DDH). The anteversion difference was different between the two groups. Multivariate analysis showed that the navigation difference (absolute difference in anteversion between postoperative CT and navigation records of > 5°) was significantly associated with severe DDH (odds ratio [OR]: 3.3; p = 0.049, 95% confidence interval [CI]: 1.0-11.1) and posterior pelvic tilt (OR: 1.1; p = 0.042, 95% CI: 1.0-1.27). CONCLUSIONS: In patients with severe DDH, it is important to pay close attention during THA using portable navigation. However, the average difference was < 5º even in patients with severe DDH, and the accuracy may be acceptable in a clinical setting when the cost is considered.


Subject(s)
Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Retrospective Studies , Female , Male , Developmental Dysplasia of the Hip/surgery , Developmental Dysplasia of the Hip/diagnostic imaging , Middle Aged , Aged , Tomography, X-Ray Computed , Surgical Navigation Systems , Adult , Surgery, Computer-Assisted/methods , Hip Prosthesis
5.
Arch Orthop Trauma Surg ; 144(5): 2381-2389, 2024 May.
Article in English | MEDLINE | ID: mdl-38554208

ABSTRACT

INTRODUCTION: This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology. MATERIALS AND METHODS: There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups. The mean absolute values of navigation error were assessed. Intraoperative pelvic tilt angles were also recorded using navigation system. RESULTS: The percentage of cups inside Lewinnek's safe zone was 100% in the navigation group and 35% in the control group (p < 0.001). The mean absolute values of navigation error in inclination and anteversion were 2.9° ± 2.1° and 3.3° ± 2.4°, respectively. The mean abduction angle of the pelvis was 5.1° ± 4.8° after placing the patients in the lateral decubitus position and 4.1° ± 6.0° after cup placement. The mean posterior tilt angle was 6.8° ± 5.1° after placing the patients in the lateral decubitus position and 9.3° ± 5.9° after cup placement. The mean internal rotation angle was 14.8° ± 7.4° after cup placement. There were no correlations between the navigation error in inclination or anteversion and the absolute values of changes of the pelvic tilt angle at any phase. CONCLUSIONS: Although progressive pelvic motion occurred in THA in the lateral decubitus position, especially during cup placement, the CT-based navigation system with AR technology improved cup placement accuracy.


Subject(s)
Arthroplasty, Replacement, Hip , Patient Positioning , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Tomography, X-Ray Computed/methods , Retrospective Studies , Middle Aged , Aged , Patient Positioning/methods , Hip Prosthesis , Augmented Reality , Surgical Navigation Systems , Surgery, Computer-Assisted/methods , Pelvis/diagnostic imaging , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery
6.
Minim Invasive Ther Allied Technol ; 33(3): 176-183, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38334755

ABSTRACT

INTRODUCTION: The use of laparoscopic and robotic liver surgery is increasing. However, it presents challenges such as limited field of view and organ deformations. Surgeons rely on laparoscopic ultrasound (LUS) for guidance, but mentally correlating ultrasound images with pre-operative volumes can be difficult. In this direction, surgical navigation systems are being developed to assist with intra-operative understanding. One approach is performing intra-operative ultrasound 3D reconstructions. The accuracy of these reconstructions depends on tracking the LUS probe. MATERIAL AND METHODS: This study evaluates the accuracy of LUS probe tracking and ultrasound 3D reconstruction using a hybrid tracking approach. The LUS probe is tracked from laparoscope images, while an optical tracker tracks the laparoscope. The accuracy of hybrid tracking is compared to full optical tracking using a dual-modality tool. Ultrasound 3D reconstruction accuracy is assessed on an abdominal phantom with CT transformed into the optical tracker's coordinate system. RESULTS: Hybrid tracking achieves a tracking error < 2 mm within 10 cm between the laparoscope and the LUS probe. The ultrasound reconstruction accuracy is approximately 2 mm. CONCLUSION: Hybrid tracking shows promising results that can meet the required navigation accuracy for laparoscopic liver surgery.


Subject(s)
Imaging, Three-Dimensional , Laparoscopy , Liver , Phantoms, Imaging , Ultrasonography , Laparoscopy/methods , Humans , Imaging, Three-Dimensional/methods , Ultrasonography/methods , Liver/diagnostic imaging , Liver/surgery , Surgery, Computer-Assisted/methods , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Surgical Navigation Systems , Laparoscopes
7.
Minim Invasive Ther Allied Technol ; 33(3): 129-139, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38265868

ABSTRACT

BACKGROUND: We report a new real-time navigation system for laparoscopic hepatectomy (LH), which resembles a car navigation system. MATERIAL AND METHODS: Virtual three-dimensional liver and body images were reconstructed using the "New-VES" system, which worked as roadmap during surgery. Several points of the patient's body were registered in virtual images using a magnetic position sensor (MPS). A magnetic transmitter, corresponding to an artificial satellite, was placed about 40 cm above the patient's body. Another MPS, corresponding to a GPS antenna, was fixed on the handling part of the laparoscope. Fiducial registration error (FRE, an error between real and virtual lengths) was utilized to evaluate the accuracy of this system. RESULTS: Twenty-one patients underwent LH with this system. Mean FRE of the initial five patients was 17.7 mm. Mean FRE of eight patients in whom MDCT was taken using radiological markers for registration of body parts as first improvement, was reduced to 10.2 mm (p = .014). As second improvement, a new MPS as an intraoperative body position sensor was fixed on the right-sided chest wall for automatic correction of postural gap. The preoperative and postoperative mean FREs of 8 patients with both improvements were 11.1 mm and 10.1 mm (p = .250). CONCLUSIONS: Our system may provide a promising option that virtually guides LH.


Subject(s)
Hepatectomy , Laparoscopy , Humans , Hepatectomy/methods , Hepatectomy/instrumentation , Laparoscopy/methods , Laparoscopy/instrumentation , Female , Male , Middle Aged , Aged , Imaging, Three-Dimensional , Liver Neoplasms/surgery , Surgical Navigation Systems , Adult , Magnetics/instrumentation , Surgery, Computer-Assisted/methods
8.
Surg Innov ; 31(1): 48-57, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38019844

ABSTRACT

BACKGROUND: Computer assisted surgical navigation systems are designed to improve outcomes by providing clinicians with procedural guidance information. The use of new technologies, such as mixed reality, offers the potential for more intuitive, efficient, and accurate procedural guidance. The goal of this study is to assess the positional accuracy and consistency of a clinical mixed reality system that utilizes commercially available wireless head-mounted displays (HMDs), custom software, and localization instruments. METHODS: Independent teams using the second-generation Microsoft HoloLens© hardware, Medivis SurgicalAR© software, and localization instruments, tested the accuracy of the combined system at different institutions, times, and locations. The ASTM F2554-18 consensus standard for computer-assisted surgical systems, as recognized by the U.S. FDA, was utilized to measure the performance. 288 tests were performed. RESULTS: The system demonstrated consistent results, with an average accuracy performance that was better than one millimeter (.75 ± SD .37 mm). CONCLUSION: Independently acquired positional tracking accuracies exceed conventional in-market surgical navigation tracking systems and FDA standards. Importantly, the performance was achieved at two different institutions, using an international testing standard, and with a system that included a commercially available off-the-shelf wireless head mounted display and software.


Subject(s)
Augmented Reality , Surgery, Computer-Assisted , United States , Surgery, Computer-Assisted/methods , Surgical Navigation Systems , United States Food and Drug Administration , Software
9.
J Digit Imaging ; 36(4): 1919-1929, 2023 08.
Article in English | MEDLINE | ID: mdl-37131064

ABSTRACT

To evaluate the feasibility and accuracy of AR-assisted pedicle screw placement using a new intraoperative rapid registration method of combining preoperative CT scanning and intraoperative C-arm 2D fluoroscopy in cadavers. Five cadavers with intact thoracolumbar spines were employed in this study. Intraoperative registration was performed using anteroposterior and lateral views of preoperative CT scanning and intraoperative 2D fluoroscopic images. Patient-specific targeting guides were used for pedicle screw placement from Th1-L5, totaling 166 screws. Instrumentation for each side was randomized (augmented reality surgical navigation (ARSN) vs. C-arm) with an equal distribution of 83 screws in each group. CT was performed to evaluate the accuracy of both techniques by assessing the screw positions and the deviations between the inserted screws and planned trajectories. Postoperative CT showed that 98.80% (82/83) screws in ARSN group and 72.29% (60/83) screws in C-arm group were within the 2-mm safe zone (p < 0.001). The mean time for instrumentation per level in ARSN group was significantly shorter than that in C-arm group (56.17 ± 3.33 s vs. 99.22 ± 9.03 s, p < 0.001). The overall intraoperative registration time was 17.2 ± 3.5 s per segment. AR-based navigation technology can provide surgeons with accurate guidance of pedicle screw insertion and save the operation time by using the intraoperative rapid registration method of combining preoperative CT scanning and intraoperative C-arm 2D fluoroscopy.


Subject(s)
Augmented Reality , Pedicle Screws , Surgery, Computer-Assisted , Humans , Cadaver , Fluoroscopy/methods , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Surgery, Computer-Assisted/methods , Surgical Navigation Systems
11.
J Craniofac Surg ; 34(2): 525-531, 2023.
Article in English | MEDLINE | ID: mdl-36173942

ABSTRACT

This study aimed to investigate the feasibility and accuracy of osteotomy and distractor placement using a robotic navigation system in a model surgical experiment of mandibular distraction osteogenesis for hemifacial microsomia. Imaging data from 5 patients with Pruzansky-Kaban type II (IIa: 4; IIb: 1) mandibular deformities were used to print 3D models for simulated mandibular distraction osteogenesis. In the experimental group, a robot-assisted surgical navigation system was used to perform the surgery under robotic guidance following registration, according to the preoperative design. Conventional surgery was performed in the control group, in which the operation was based on intraoperative estimations of the preoperative design by experienced surgeons. The accuracies of the osteotomy and distractor placement were assessed based on distance and angular error. Osteotomy accuracy was higher in the experimental group than in the control group, and the distance error ( t =9.311, P <0.001) and angular error ( t =5.385, P =0.001) were significantly reduced. The accuracy of distractor placement was also significantly higher in the experimental group, while the distance error ( t =3.048, P =0.016) and angular error ( t =3.524, P =0.024) were significantly reduced. The present results highlight the feasibility of robot-assisted distraction osteogenesis combined with electromagnetic navigation for improved surgical precision in clinical settings.


Subject(s)
Goldenhar Syndrome , Osteogenesis, Distraction , Robotics , Humans , Goldenhar Syndrome/surgery , Osteogenesis, Distraction/methods , Feasibility Studies , Surgical Navigation Systems , Imaging, Three-Dimensional/methods , Mandible/surgery , Facial Asymmetry/surgery
12.
Breast J ; 2023: 9993852, 2023.
Article in English | MEDLINE | ID: mdl-38162957

ABSTRACT

Introduction: Elucent Medical has introduced a novel EnVisio™ Surgical Navigation system which uses SmartClips™ that generate a unique electromagnetic signal triangulated in 3 dimensions for real-time navigation. The purpose of this study was to evaluate the efficacy and feasibility of the EnVisio Surgical Navigation system in localizing and excising nonpalpable lesions in breast and axillary surgery. Methods: This pilot study prospectively examined patients undergoing breast and nodal localization using the EnVisio Surgical Navigation system. SmartClips were placed by designated radiologists using ultrasound (US) or mammographic (MMG) guidance. The technical evaluation focused on successful deployment and subsequent excision of all localized lesions including SmartClips and biopsy clips. Results: Eleven patients underwent localization using 27 SmartClips which included bracketed multifocal disease (n = 4) and clipped lymph node (n = 1). The bracketed cases were each localized with 2 SmartClips. Mammography and ultrasound were used (n = 8 and n = 19, respectively) to place the SmartClips. All 27 devices were successfully deployed within 5 mm of the targeted lesion or biopsy clip. All SmartClip devices were identified and retrieved intraoperatively. No patients required a second operation for margin excision. Conclusion: In a limited sample, the EnVisio Surgical Navigation system was a reliable technology for the localization of breast and axillary lesions planned for surgical excision. Further comparative studies are required to evaluate its efficacy in relation to the other existing localization modalities.


Subject(s)
Breast Neoplasms , Surgical Navigation Systems , Humans , Female , Pilot Projects , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Lymph Nodes/pathology , Lymph Node Excision/methods , Sentinel Lymph Node Biopsy , Axilla/diagnostic imaging , Axilla/surgery
13.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 40(6): 676-684, 2022 Dec 01.
Article in English, Chinese | MEDLINE | ID: mdl-36416320

ABSTRACT

OBJECTIVES: This study aimed to build a surgical navigation system based on mixed reality (MR) and optical positioning technique and evaluate its clinical applicability in craniomaxillofacial trauma bone reconstruction. Me-thods We first integrated the software and hardware platforms of the MR-based surgical navigation system and explored the system workflow. The systematic error, target registration error, and osteotomy application error of the system were then analyzed via 3D printed skull model experiment. The feasibility of the MR-based surgical navigation system in craniomaxillofacial trauma bone reconstruction was verified via zygomatico-maxillary complex (ZMC) reduction experiment of the skull model and preliminary clinical study. RESULTS: The system error of this MR-based surgical navigation system was 1.23 mm±0.52 mm, the target registration error was 2.83 mm±1.18 mm, and the osteotomy application error was 3.13 mm±1.66 mm. Virtual surgical planning and the reduction of the ZMC model were successfully conducted. In addition, with the guidance of the MR-based navigation system, the frontal bone defect was successfully reconstructed, and the clinical outcome was satisfactory. CONCLUSIONS: The MR-based surgical navigation system has its advantages in virtual reality fusion effect and dynamic navigation stability. It provides a new method for doctor-patient communications, education, preoperative planning, and intraoperative navigation in craniomaxillofacial surgery.


Subject(s)
Augmented Reality , Plastic Surgery Procedures , Humans , Surgical Navigation Systems , Skull/surgery
14.
Sci Rep ; 12(1): 13181, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35915079

ABSTRACT

Midfacial hypoplasia is a common maxillofacial deformity in patients with cleft lip and palate, which requires surgical treatment. However, trans-sutural distraction osteogenesis (TSDO) remains some disadvantages, including difficulty in accurate location of surgical path, prolonged operation time, and excess surgical bleeding. This study aimed to evaluate the application of an optical surgical navigation system (OSNS) developed for TSDO. Six consecutive patients with midfacial hypoplasia who required TSDO were included in the study. Preoperatively, a head computed tomography was performed, and the data were imported into Mimics software (version: 20.0.0.691, Materialise Inc, Belgium) to design a three-dimensional simulation of the surgical approach. TSDO was performed with the use of OSNS. The accuracy and results of the procedure were initially evaluated by comparing the preoperative and postoperative periods. The patients included five boys and one girl, with an average age of 10 years; five with postoperative cleft lip and palate, and one without combined cleft lip and palate. The surgical procedure was successful, with a postoperative follow-up of 4-5 months. All patients demonstrated good treatment results without complications. In conclusioin, OSNS-assisted TSDO can noninvasively correct midfacial dysplasia, improve surgical precision, reduce bleeding and obtain better clinical results. OSNS can guide the TSDO safely and effectively.


Subject(s)
Cleft Lip , Cleft Palate , Osteogenesis, Distraction , Child , Cleft Lip/diagnostic imaging , Cleft Lip/surgery , Cleft Palate/diagnostic imaging , Cleft Palate/surgery , Female , Humans , Male , Maxilla/surgery , Osteogenesis, Distraction/methods , Surgical Navigation Systems , Treatment Outcome
15.
Biomed Tech (Berl) ; 67(5): 411-417, 2022 Oct 26.
Article in English | MEDLINE | ID: mdl-35786446

ABSTRACT

This paper proposes a conceptual method to calculate the pose of a stereo-vision camera relative to an artificial mandible without additional markers. The general method for marker-free navigation has four steps: 1) parallel image acquisition by a stereo-vision camera, 2) automatic identification of 2d point pairs (landmark pairs) in a left and a right image, 3) calculation of related 3d points in the joint camera coordinate system and 4) matching of 3d points generated to a preoperative 3d model (i.e., CT data based). To identify and compare landmarks in the acquired stereo images, well-known algorithms for landmark detection, description and matching were compared within the developed approach. Finally, the BRISK algorithm (Leutenegger S, Chli M, Siegwart RY. BRISK: Binary Robust invariant scalable keypoints. Proceedings of the IEEE International Conference on Computer Vision; 2011: 2548-2555) was used. The proposed method was implemented in MATLAB® and validated in vitro with one artificial mandible. The accuracy evaluation of the camera positions calculated resulted in an average deviation error of 1.45 mm ± 0.76 mm to the real camera displacement. This value was calculated using only stereo images with over 100 reconstructed landmark pairs each. This provides the basis for marker-free navigation.


Subject(s)
Surgery, Computer-Assisted , Surgical Navigation Systems , Algorithms , Imaging, Three-Dimensional/methods , Surgery, Computer-Assisted/methods
16.
J Digit Imaging ; 35(6): 1530-1543, 2022 12.
Article in English | MEDLINE | ID: mdl-35819536

ABSTRACT

Hypertensive intracerebral hemorrhage (HICH) is an intracerebral bleeding disease that affects 2.5 per 10,000 people worldwide each year. An effective way to cure this disease is puncture through the dura with a brain puncture drill and tube; the accuracy of the insertion determines the quality of the surgery. In recent decades, surgical navigation systems have been widely used to improve the accuracy of surgery and minimize risks. Augmented reality- and mixed reality-based surgical navigation is a promising new technology for surgical navigation in the clinic, aiming to improve the safety and accuracy of the operation. In this study, we present a novel multimodel mixed reality navigation system for HICH surgery in which medical images and virtual anatomical structures can be aligned intraoperatively with the actual structures of the patient in a head-mounted device and adjusted when the patient moves in real time while under local anesthesia; this approach can help the surgeon intuitively perform intraoperative navigation. A novel registration method is used to register the holographic space and serves as an intraoperative optical tracker, and a method for calibrating the HICH surgical tools is used to track the tools in real time. The results of phantom experiments revealed a mean registration error of 1.03 mm and an average time consumption of 12.9 min. In clinical usage, the registration error was 1.94 mm, and the time consumption was 14.2 min, showing that this system is sufficiently accurate and effective for clinical application.


Subject(s)
Augmented Reality , Intracranial Hemorrhage, Hypertensive , Surgery, Computer-Assisted , Humans , Surgical Navigation Systems , Intracranial Hemorrhage, Hypertensive/diagnostic imaging , Intracranial Hemorrhage, Hypertensive/surgery , Surgery, Computer-Assisted/methods , Phantoms, Imaging , Imaging, Three-Dimensional
17.
Sci Rep ; 12(1): 7893, 2022 05 12.
Article in English | MEDLINE | ID: mdl-35550552

ABSTRACT

This study analyzed the outcomes of zygomatico-orbital fracture reconstruction using the real-time navigation system with intraoperative three-dimensional (3D) C-arm computed tomography (CT). Fifteen patients with zygomatico-orbital or isolated orbital/zygoma fractures were enrolled in this prospective cohort. For zygoma reduction, the displacement at five key sutures and the differences between preoperative and intraoperative CT images were compared. For orbital reconstruction, the bilateral orbital volume differences in the anterior, middle, and posterior angles over the medial transitional buttress were measured. Two patients required implant adjustment once after the intraoperative 3D C-arm assessment. On comparing the preoperative and postoperative findings for the zygoma, the average sum of displacement was 19.48 (range, 5.1-34.65) vs. 1.96 (0-3.95) mm (P < 0.001) and the deviation index was 13.56 (10-24.35) vs. 2.44 (0.6-4.85) (P < 0.001). For the orbit, the mean preoperative to postoperative bilateral orbital volume difference was 3.93 (0.35-10.95) vs. 1.05 (0.12-3.61) mm3 (P < 0.001). The mean difference in the bilateral angles at the transition buttress was significantly decreased postoperatively at the middle and posterior one-third. There was no significant difference in orbital volume, angle of the transition zone, and the sum of five zygoma distances between post operative results and preoperative virtual planning. The surgical navigation system with the intraoperative 3D C-arm can effectively improve the accuracy of zygomatico-orbital fracture reconstruction and decrease implant adjustment times.


Subject(s)
Orbital Fractures , Plastic Surgery Procedures , Surgery, Computer-Assisted , Humans , Orbit/diagnostic imaging , Orbit/surgery , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Prospective Studies , Plastic Surgery Procedures/methods , Surgery, Computer-Assisted/methods , Surgical Navigation Systems , Tomography, X-Ray Computed
18.
Med Phys ; 49(7): 4845-4860, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35543150

ABSTRACT

BACKGROUND: Although the surface registration technique has the advantage of being relatively safe and the operation time is short, it generally has the disadvantage of low accuracy. PURPOSE: This research proposes automated machine learning (AutoML)-based surface registration to improve the accuracy of image-guided surgical navigation systems. METHODS: The state-of-the-art surface registration concept is that first, using a neural network model, a new point-cloud that matches the facial information acquired by a passive probe of an optical tracking system (OTS) is extracted from the facial information obtained by computerized tomography. Target registration error (TRE) representing the accuracy of surface registration is then calculated by applying the iterative closest point (ICP) algorithm to the newly extracted point-cloud and OTS information. In this process, the hyperparameters used in the neural network model and ICP algorithm are automatically optimized using Bayesian optimization with expected improvement to yield improved registration accuracy. RESULTS: Using the proposed surface registration methodology, the average TRE for the targets located in the sinus space and nasal cavity of the soft phantoms is 0.939 ± 0.375 mm, which shows 57.8% improvement compared to the average TRE of 2.227 ± 0.193 mm calculated by the conventional surface registration method (p < 0.01). The performance of the proposed methodology is evaluated, and the average TREs computed by the proposed methodology and the conventional method are 0.767 ± 0.132 and 2.615 ± 0.378 mm, respectively. Additionally, for one healthy adult, the clinical applicability of the AutoML-based surface registration is also presented. CONCLUSION: Our findings showed that the registration accuracy could be improved while maintaining the advantages of the surface registration technique.


Subject(s)
Surgery, Computer-Assisted , Surgical Navigation Systems , Algorithms , Bayes Theorem , Machine Learning , Phantoms, Imaging , Surgery, Computer-Assisted/methods
19.
Med Phys ; 49(6): 3963-3979, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35383964

ABSTRACT

BACKGROUND: The number of patients who suffer from glioma has been increasing, and this malignancy is a serious threat to human health. The mainstream treatment for glioma is surgical resection; therefore, accurate resection can improve postoperative patient recovery. PURPOSE: Many studies have investigated surgical navigation guided by mixed reality, with good outcomes. However, the limitations of mixed reality, such as spatial drift caused by environmental changes, limit its clinical application. Therefore, we present a mixed reality surgical navigation system for glioma resection. Preoperative information can be fused precisely with the real patient with the spatial compensation method to achieve clinically suitable accuracy. METHODS: A head-mounted device was used to display virtual information, and a markerless spatial registration method was applied to precisely align the virtual anatomy with the real patient preoperatively. High-accuracy preoperative and intraoperative movement and spatial drift compensation methods were used to increase the positional accuracy of the mixed reality-guided glioma resection system when the patient's head is fixed to the bed frame. Several experiments were designed to validate the accuracy and efficacy of this system. RESULTS: Phantom experiments were performed to test the efficacy and accuracy of this system under ideal conditions, and clinical tests were conducted to assess the performance of this system in clinical application. The accuracy of spatial registration was 1.18 mm in the phantom experiments and 1.86 mm in the clinical application. CONCLUSIONS: Herein, we present a mixed reality-based multimodality-fused surgical navigation system for assisting surgeons in intuitively identifying the glioma boundary intraoperatively. The experimental results indicate that this system has suitable accuracy and efficacy for clinical usage.


Subject(s)
Augmented Reality , Glioma , Surgery, Computer-Assisted , Adult , Glioma/diagnostic imaging , Glioma/surgery , Humans , Imaging, Three-Dimensional , Phantoms, Imaging , Surgery, Computer-Assisted/methods , Surgical Navigation Systems
20.
J Healthc Eng ; 2022: 3362495, 2022.
Article in English | MEDLINE | ID: mdl-35222882

ABSTRACT

Ultrasound (US) imaging system is widely used in robotic systems for precision positioning in clinical applications. The US calibration is critical to minimize the difference of spatial coordinates between instruments, for minimally invasive surgery (MIS) in navigation systems. In this study, we propose a dual robotic arm system that combines US imaging with one arm for path planning and monitoring and accurate positioning with the other arm for instrument placement via the preplanning procedures. A phantom with N-wire and N-wedge was designed for US calibration. The US calibration showed a mean error of 0.76 mm; the mean dual-arm calibration error is 0.31 mm. The positioning error of the system was verified with a mean error of 1.48 mm. In addition, we used two abdominal phantoms with computed tomography scan validation, with an averaged position error of 1.867 ± 0.436 mm and an orientation error of 2.190 ± 0.764°. The proposed system is aimed to perform clinical operations, such as abdominal MIS, with real-time image monitoring of the organ tissues and instrument positions, which meet the requirements for medical application.


Subject(s)
Surgery, Computer-Assisted , Surgical Navigation Systems , Calibration , Humans , Imaging, Three-Dimensional/methods , Phantoms, Imaging , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Ultrasonography/methods