Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.985
Filter
1.
BMJ Case Rep ; 17(6)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38844356

ABSTRACT

A man in his 40s presented to the emergency department after 2 weeks of abdominal pain and bloating. Radiological investigations revealed multiple unusual sites of thrombosis, including large thrombi in his portal and mesenteric veins, and a left ventricular thrombus with resultant embolic infarcts to his spleen, kidneys, coronary arteries and brain. Standard causes of underlying thrombophilia were excluded. A serum protein electrophoresis and serum-free light chains, with subsequent bone marrow biopsy, lead to the diagnosis of smouldering multiple myeloma (sMM), albeit an unusual presentation with severe clinical sequelae. Although sMM is known to be associated with an increased risk of venous thromboembolism, it is not recognised to cause thrombosis in both venous and arterial vascular beds simultaneously. Physicians encountering patients with multiple thrombi in unusual vascular beds without clear aetiology should consider an underlying monoclonal gammopathy in their list of differentials.


Subject(s)
Multiple Myeloma , Humans , Male , Multiple Myeloma/complications , Multiple Myeloma/diagnosis , Venous Thrombosis/etiology , Venous Thrombosis/diagnostic imaging , Adult , Thrombosis/etiology , Thrombosis/diagnostic imaging , Thrombosis/diagnosis , Paraproteinemias/complications , Paraproteinemias/diagnosis , Diagnosis, Differential
2.
Chest ; 165(6): e163-e167, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38852972

ABSTRACT

This novel report presents the first known case, to our knowledge, of a 16-year-old male patient who experienced intraventricular thrombosis and pulmonary embolism after a Nuss procedure for pectus excavatum, attributed to chronic bar displacement. Two years after the operation, the patient experienced post-exercise cough and hemoptysis, which led to his admission. Imaging revealed pulmonary embolism, thrombosis in the right ventricular outflow tract, and lung infiltrative lesions. We hypothesize that the chronic bar displacement led to its embedment in the right ventricle, resulting in thrombus formation, which subsequently contributed to partial pulmonary embolism. Surgery revealed the bars' intrusion into the right ventricle and lung. This case highlights the risk of severe complications from bar displacement in the Nuss procedure, which necessitates long-term follow-up evaluation, caution against strenuous activities after surgery, and use of thoracoscopic guidance during bar implantation and removal. It underscores the importance of vigilant evaluation for late-stage complications in patients with respiratory distress or thrombosis after a Nuss procedure.


Subject(s)
Funnel Chest , Pulmonary Embolism , Thrombosis , Humans , Pulmonary Embolism/etiology , Pulmonary Embolism/diagnosis , Male , Adolescent , Funnel Chest/surgery , Thrombosis/etiology , Thrombosis/diagnostic imaging , Thrombosis/diagnosis , Heart Ventricles/diagnostic imaging , Postoperative Complications/etiology , Postoperative Complications/diagnosis , Tomography, X-Ray Computed
3.
Sci Rep ; 14(1): 10438, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714704

ABSTRACT

Thrombus formation in extracorporeal membrane oxygenation (ECMO) remains a major concern as it can lead to fatal outcomes. To the best of our knowledge, there is no standard non-invasive method for quantitatively measuring thrombi. This study's purpose was to verify thrombus detection in an ECMO circuit using novel, non-invasive ultrasonic sensors in real-time, utilizing the fact that the ultrasonic velocity in a thrombus is known to be higher than that in the blood. Ultrasonic sensors with a customized chamber, an ultrasonic pulse-receiver, and a digital storage oscilloscope (DSO) were used to set up the measuring unit. The customized chamber was connected to an ECMO circuit primed with porcine blood. Thrombi formed from static porcine blood were placed in the circuit and ultrasonic signals were extracted from the oscilloscope at various ECMO flow rates of 1-4 L/min. The ultrasonic signal changes were successfully detected at each flow rate on the DSO. The ultrasonic pulse signal shifted leftward when a thrombus passed between the two ultrasonic sensors and was easily detected on the DSO screen. This novel real-time non-invasive thrombus detection method may enable the early detection of floating thrombi in the ECMO system and early management of ECMO thrombi.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Thrombosis/diagnostic imaging , Thrombosis/diagnosis , Animals , Swine , Ultrasonics , Ultrasonography/methods
4.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(5): 464-469, 2024 May 12.
Article in Chinese | MEDLINE | ID: mdl-38706070

ABSTRACT

In situ pulmonary arterial thrombosis (ISPAT) refers to the formation of new blood clots in the pulmonary arterial system in the absence of pre-existing clots in the peripheral venous system. With the emergence and prevalence of COVID-19, ISPAT has become an increasingly important cause of pulmonary arterial thrombosis (PAT) alongside thromboembolism. Several factors such as hypoxia, inflammation, endothelial dysfunction, and hypercoagulable state can lead to ISPAT, which is associated with a number of conditions such as thoracic trauma, partial lung resection, pulmonary infectious disease, pulmonary vasculitis, connective tissue diseases, severe pulmonary hypertension, radiation pneumonitis, and acute chest syndrome in sickle cell disease. It is important to differentiate between pulmonary thromboembolism (PTE) and ISPAT for proper disease management and prognosis. In this review, we summarized the characteristics of ISPAT under different disease conditions, the methods to distinguish ISPAT from PTE, and the best treatment strategies. We hoped that this review could improve clinicians' understanding of this independent disease and provide guidance for the refined treatment of patients with PAT.


Subject(s)
COVID-19 , Pulmonary Artery , Thrombosis , Humans , COVID-19/complications , COVID-19/diagnosis , COVID-19/therapy , Thrombosis/diagnosis , Thrombosis/therapy , Pulmonary Embolism/diagnosis , Pulmonary Embolism/therapy , SARS-CoV-2
6.
Hemoglobin ; 48(2): 79-86, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38565203

ABSTRACT

Hemoglobin (Hb) Volga is a rare, unstable ß-chain hemoglobin variant (ß27 Ala→Asp), causing chronic hemolytic anemia. This study presents two members of a Danish family, splenectomized due to Hb Volga at and with multiple thrombotic events. The proband was diagnosed with Hb Volga 9 years old and splenectomy was performed as a part of treatment. Throughout his life, he experienced multiple superficial thrombophlebitis, two episodes of distal deep venous thrombosis (DVT) on lower extremities (age 32 and 33) and a transient ischemic attack (TIA) presented as amaurosis fugax (age 51). Thrombophilia investigation was normal. The proband's son was diagnosed with Hb Volga and underwent splenectomy at the age of 6. Despite anticoagulation therapy, he suffered from multiple venous thromboembolic events in his youth and died of chronic pulmonary embolism (PE)/pulmonary hypertension combined with infection. Given the observed propensity for multiple thromboses in these two patients, a literature review was conducted investigating reported occurrence of thrombotic events in individuals with Hb Volga.Currently 25 cases of Hb Volga are reported worldwide. The clinical symptoms primarily described are related to hemolytic anemia. Splenectomy is reported in 15 patients. Thromboses have previously been reported in only three patients who were also splenectomized. These cases involved DVT and PE, myocardial infarction, and an unspecified thrombotic event. The proband represents the first reported Hb Volga case with both venous and arterial thrombotic disorders. The exact mechanism underlying thrombotic tendency in patients with Hb Volga remains unknown, but it is probably associated with splenectomy.


Subject(s)
Hemoglobins, Abnormal , Splenectomy , Humans , Splenectomy/adverse effects , Male , Hemoglobins, Abnormal/genetics , Adult , Thrombosis/etiology , Thrombosis/diagnosis , Middle Aged , Denmark/epidemiology , Venous Thrombosis/etiology , Venous Thrombosis/diagnosis , Child , Pedigree
7.
Int J Lab Hematol ; 46 Suppl 1: 34-42, 2024 May.
Article in English | MEDLINE | ID: mdl-38584293

ABSTRACT

Antiphospholipid syndrome (APS) is an autoimmune disease characterized by thrombotic manifestations and/or obstetric complications in patients with persistently positive antiphospholipid antibodies (aPL). aPL are a heterogeneous group of autoantibodies, but only lupus anticoagulant, anticardiolipin (aCL), and antibeta2-glycoprotein I antibodies (aß2GPI) IgG or IgM are included as laboratory classification criteria. Seronegative APS patients are usually defined as patients with the clinical symptoms of APS but who test negative for aPL. The negativity to classic aPL criteria does not exclude the presence of other aPL. Several noncriteria aPL have been identified. Some noncriteria aPL are well studied, such as IgA aCL and aß2GPI, the antiphosphatidylserine-prothrombin (aPS/PT) antibodies, and the antibodies against the domain I of beta2-glycoprotein I (aDI), both latter groups receiving more attention for their role in thrombotic events and pregnancy complications. Other noncriteria aPL that have been studied are antibodies against annexin V, prothrombin, phosphatidylethanolamine, phosphatidic acid, phosphatidylserine, phosphatidylinositol, vimentin-cardiolipin complex, anti-protein S/protein C. Measurement of some of these noncriteria aPL (aPS/PT, aDI) is useful in the laboratory work-out of APS in specific situations. We have to differentiate between patients who are positive for noncriteria aPL only, and patients who have both criteria and noncriteria aPL to enable us to study their role in the diagnosis or risk stratification of APS. The research on noncriteria aPL is continually developing as the clinical relevance of these antibodies is not yet fully clarified.


Subject(s)
Antibodies, Antiphospholipid , Antiphospholipid Syndrome , Humans , Antiphospholipid Syndrome/immunology , Antiphospholipid Syndrome/diagnosis , Antiphospholipid Syndrome/blood , Antibodies, Antiphospholipid/blood , Antibodies, Antiphospholipid/immunology , Female , Pregnancy , Thrombosis/etiology , Thrombosis/immunology , Thrombosis/blood , Thrombosis/diagnosis , beta 2-Glycoprotein I/immunology , Autoantibodies/blood , Autoantibodies/immunology
8.
J Int Med Res ; 52(4): 3000605241244763, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38656272

ABSTRACT

A high systolic/diastolic (S/D) ratio of umbilical cord blood is a manifestation of intrauterine hypoxia. However, the clinical significance of a persistently decreased S/D ratio of umbilical cord blood has not been reported. We report eight cases of a persistently decreased S/D ratio of umbilical cord blood, with two cases of umbilical thrombus, five cases of excessive torsion, and one case of a true cord knot. Fetuses with a persistently decreased S/D ratio of umbilical cord blood may be at risk, and it may be an important indication of umbilical cord lesions.


Subject(s)
Diastole , Fetal Blood , Umbilical Cord , Adult , Female , Humans , Male , Pregnancy , Fetal Hypoxia/diagnosis , Fetal Hypoxia/physiopathology , Systole/physiology , Thrombosis/diagnosis , Ultrasonography, Prenatal , Umbilical Cord/pathology
15.
Adv Sci (Weinh) ; 11(21): e2304748, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38342628

ABSTRACT

Many cardiovascular problems stem from blockages that form within the vasculature and often treatment includes fitting a stent through percutaneous coronary intervention. This offers a minimally invasive therapy but re-occlusion through restenosis or thrombosis formation often occurs post-deployment. Research is ongoing into the creation of smart stents that can detect the occurrence of further problems. In this study, it is shown that selectively metalizing a non-conductive stent can create a set of electrodes that are capable of detecting a build-up of material around the stent. The associated increase in electrical impedance across the electrodes is measured, testing the stent with blood clot to mimic thrombosis. It is shown that the device is capable of sensing different amounts of occlusion. The stent can reproducibly sense the presence of clot showing a 16% +/-3% increase in impedance which is sufficient to reliably detect the clot when surrounded by explanted aorta (one sample t-test, p = 0.009, n = 9). It is demonstrated that this approach can be extended beyond the 3D printed prototypes by showing that it can be applied to a commercially available stent and it is believed that it can be further utilized by other types of medical implants.


Subject(s)
Biosensing Techniques , Stents , Thrombosis , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Thrombosis/diagnosis , Humans , Animals , Electric Impedance
16.
Rev. esp. cardiol. (Ed. impr.) ; 77(2): 158-166, feb. 2024.
Article in Spanish | IBECS | ID: ibc-230484

ABSTRACT

Introduction and objectives Chronic thromboembolic disease refers to the presence of chronic thrombotic pulmonary vascular thrombosis without pulmonary hypertension (PH) at rest but with exercise limitation after pulmonary embolism (PE). Our aim was to evaluate the hemodynamic response to exercise in these patients and its correlation with the values reached in cardiopulmonary exercise testing. Methods We included symptomatic patients with persistent pulmonary thrombosis after PE. We excluded patients with left heart disease or significant PH (mean pulmonary arterial pressure [mPAP] >25mmHg, pulmonary vascular resistance >3 WU, and pulmonary capillary wedge pressure [PCWP] >15mmHg). Cardiopulmonary exercise testing and exercise right heart catheterization were performed. Exercise-induced precapillary PH was defined as mPAP/CO slope >3 and PCWP/CO slope <2mmHg/l/min. The hemodynamic response and the values obtained in cardiopulmonary exercise testing were compared between patients with and without exercise-induced precapillary PH. Results We studied 36 patients; 4 were excluded due to incomplete hemodynamic data. Out of the 32 patients analyzed; 3 developed a pathological increase in PCWP. Among the remaining 29 patients (mean age, 49.4±13.7 years, 34.5% women), 13 showed exercise-induced PH. Resting mPAP was higher in those who developed exercise-induced PH (23.3±5.4 vs 19.0±3.8mmHg; P=.012), although CO was similar in the 2 groups. Patients with exercise-induced PH exhibited data of ventilatory inefficiency with reduced values of end-tidal CO2 pressure at the anaerobic threshold (32.8±3.0 vs 36.2±3.3mmHg; P=.021) and a higher Ve/VCO2 slope (34.2±4.8 vs 30.7±5.0; P=.049). Conclusions Exercise limitation and ventilatory inefficiency could be attributable to exercise-induced precapillary PH in a subgroup of patients with persistent pulmonary thrombosis and dyspnea (AU)


Introdución y objetivos La enfermedad tromboembólica crónica se define como la trombosis crónica de la vasculatura pulmonar y disnea, sin hipertensión pulmonar (HP) en reposo tras una embolia de pulmón. El estudio evaluó la hemodinámica al esfuerzo en estos pacientes y su relación con la ergoespirometría. Métodos Se incluyó a pacientes sintomáticos con trombosis pulmonar crónica tras una embolia de pulmón. Se excluyó a los pacientes con cardiopatía izquierda o HP significativa en reposo (presión arterial pulmonar media [PAPm] >25mmHg, resistencia vascular pulmonar >3 UW y presión capilar pulmonar [PCP] >15mmHg). Se realizó una ergoespirometría y un cateterismo derecho de ejercicio. La HP precapilar al ejercicio se definió como las pendientes PAPm/gasto cardiaco >3 y PCP/gasto cardiaco <2mmHg/l/min. Se comparó la respuesta hemodinámica y ergoespirométrica entre pacientes con y sin HP precapilar al ejercicio. Resultados Se estudió a 36 pacientes, excluyéndose 4 por calidad subóptima en el registro hemodinámico. Tres pacientes presentaron una elevación patológica de la PCP. De los 29 restantes (edad, 49,4±13,7 años; el 34,5% mujeres), en 13 se halló HP precapilar al ejercicio. La PAPm basal fue mayor en aquellos con HP al ejercicio (23,3±5,4 frente a 19,0±3,8mmHg; p=0,012), con similar gasto cardiaco. Aquellos con HP al ejercicio exhibieron valores reducidos de la presión de CO2 exahalada en el umbral anaeróbico (32,8±3,0 frente a 36,2±3,3mmHg; p=0,021) y mayor pendiente Ve/VCO2 (34,2±4,8 frente a 30,7±5,0; p=0,049). Conclusiones La HP precapilar al ejercicio se asocia con limitación funcional e ineficiencia ventilatoria en un subgrupo de pacientes con trombosis arterial pulmonar crónica y disnea persistente (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/etiology , Pulmonary Embolism/complications , Pulmonary Embolism/diagnosis , Thrombosis/diagnosis , Cardiac Catheterization , Chronic Disease , Diagnosis, Differential , Exercise Test , Hemodynamics/physiology
17.
Blood Adv ; 8(4): 936-946, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38163323

ABSTRACT

ABSTRACT: Thrombosis is an important manifestation of the antiphospholipid syndrome (APS). The thrombin generation (TG) test is a global hemostasis assay, and increased TG is associated with thrombosis. APS is currently diagnosed based on clinical and laboratory criteria, the latter defined as anti-cardiolipin, anti-ß2-glycoprotein I antibodies, or lupus anticoagulant (LA). APS testing is often performed after a thrombotic episode and subsequent administration of anticoagulation, which might hamper the interpretation of clotting assays used for LA testing. We set out to develop an artificial neural network (NN) that can diagnose APS in patients who underwent vitamin K antagonist (VKA) treatment, based on TG test results. Five NNs were trained to diagnose APS in 48 VKA-treated patients with APS and 64 VKA-treated controls, using TG and thrombin dynamics parameters as inputs. The 2 best-performing NNs were selected (accuracy, 96%; sensitivity, 96%-98%; and specificity, 95%-97%) and further validated in an independent cohort of VKA-anticoagulated patients with APS (n = 33) and controls (n = 62). Independent clinical validation favored 1 of the 2 selected NNs, with a sensitivity of 88% and a specificity of 94% for the diagnosis of APS. In conclusion, the combined use of TG and NN methodology allowed for us to develop an NN that diagnoses APS with an accuracy of 92% in individuals with VKA anticoagulation (n = 95). After further clinical validation, the NN could serve as a screening and diagnostic tool for patients with thrombosis, especially because there is no need to interrupt anticoagulant therapy.


Subject(s)
Antiphospholipid Syndrome , Thrombosis , Humans , Antiphospholipid Syndrome/diagnosis , Antiphospholipid Syndrome/drug therapy , Thrombin/pharmacology , Anticoagulants/adverse effects , Blood Coagulation , Lupus Coagulation Inhibitor , Thrombosis/diagnosis , Thrombosis/drug therapy , Thrombosis/etiology
18.
Clin Lab ; 70(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38213198

ABSTRACT

BACKGROUND: Risk assessment of vascular thrombosis in SLE patients with the presence of antiphospholipid antibodies (aPL) remains a challenge. The adjusted global antiphospholipid syndrome score (aGAPSS) has been validated and used to predict aPL-related thrombosis in SLE patients in some countries. Relevant data of aGAPSS in thrombotic evaluation in SLE population from China has not been reported. We aim to validate aGAPSS in thrombosis assessment in Chinese patients with SLE and to explore the correlations of aGAPSS with routine laboratory parameters and their clinical significance as well. METHODS: A total of 166 consecutive SLE patients were retrospectively analyzed. Multivariate logistic regression analysis was performed to examine the impact of multiple cardiovascular risk factors and laboratory parameters in recurrent thrombosis risk in SLE. ROC was conducted to explore the discriminative ability of aGAPSS and platelet (PLT), activated partial thromboplastin time (APTT), alone or in combination. RESULTS: Significantly higher value of aGAPSS was seen in SLE patients with vascular thrombosis. ROC curve indicated that aGAPSS of 3.5 or more had the best diagnostic accuracy for the prediction of aPL-related thrombosis in SLE patients. PLT with cutoff of 187.5 x 109/L and APTT with 37.5 seconds were predictors of aPL-related thrombosis as well. The combination of aGAPSS with PLT and APTT improved AUC compared to aGAPSS alone. CONCLUSIONS: The aGAPSS could predict the risk of aPL-related vascular thrombosis in SLE patients from China. The combination of aGAPSS with PLT and APTT was first time proved to have better predictive performance in thrombosis risk assessment in SLE.


Subject(s)
Antiphospholipid Syndrome , Lupus Erythematosus, Systemic , Thrombosis , Humans , Antiphospholipid Syndrome/complications , Antiphospholipid Syndrome/diagnosis , Retrospective Studies , Partial Thromboplastin Time , Risk Factors , Thrombosis/diagnosis , Thrombosis/etiology , Risk Assessment , Lupus Erythematosus, Systemic/complications , Lupus Erythematosus, Systemic/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...