Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.446
Filter
1.
PLoS One ; 19(5): e0302476, 2024.
Article in English | MEDLINE | ID: mdl-38709742

ABSTRACT

BACKGROUND: The Incentive Spirometer (IS) increases lung volume and improves gas exchange by visually stimulating patients to take slow, deep breaths. It prevents respiratory complications and treats postoperative atelectasis in patients undergoing abdominal, thoracic, and neurosurgical procedures. Its effectiveness has been validated in studies that support improved lung capacities and volumes in individuals with respiratory complications, postoperative thoracic surgery, upper abdominal surgery, and bariatric surgery. The modified Pachón incentive spirometer (MPIS) is a cost-effective alternative to branded IS. It is crucial to validate whether the MPIS distributes ventilation as effectively as commercial devices do. Ventilation distribution will be measured using electrical impedance tomography. OBJECTIVE: The aim is to compare the distribution of pulmonary ventilation between the MPIS and another commercial IS in healthy adults using electrical impedance tomography. METHODS: A crossover clinical trial is proposed to evaluate the measurement of pulmonary ventilation distribution using EIT in a sample of healthy adults. All participants will use a commercial flow IS and the MPIS, with the order of assignment randomized. This research will use electrical impedance tomography to validate the operation of the MPIS. CONCLUSIONS: This study protocol will compare two incentive spirometers' impact on pulmonary ventilation, potentially endorsing the adoption of a cost-effective device to enhance accessibility for targeted populations. TRIAL REGISTRATION: The study was registered in ClinicalTrials.gov (NTC05532748).


Subject(s)
Electric Impedance , Pulmonary Ventilation , Spirometry , Tomography , Humans , Adult , Spirometry/methods , Spirometry/instrumentation , Tomography/methods , Pulmonary Ventilation/physiology , Male , Female , Healthy Volunteers , Cross-Over Studies , Lung/physiology , Middle Aged , Young Adult
2.
Sci Rep ; 14(1): 10597, 2024 05 08.
Article in English | MEDLINE | ID: mdl-38719924

ABSTRACT

Parotid lumps are a heterogeneous group of mainly benign but also malignant tumors. Preoperative imaging does not allow a differentiation between tumor types. Multispectral optoacoustic tomography (MSOT) may improve the preoperative diagnostics. In this first prospective pilot trial the ability of MSOT to discriminate between the two most frequent benign parotid tumors, pleomorphic adenoma (PA) and Warthin tumor (WT) as well as to normal parotid tissue was explored. Six wavelengths (700, 730, 760, 800, 850, 900 nm) and the parameters deoxygenated (HbR), oxygenated (HbO2), total hemoglobin (HbT), and saturation of hemoglobin (sO2) were analyzed. Ten patients with PA and fourteen with WT were included (12/12 female/male; median age: 51 years). For PA, the mean values for all measured wave lengths as well as for the hemoglobin parameters were different for the tumors compared to the healthy parotid (all p < 0.05). The mean MSOT parameters were all significantly higher (all p < 0.05) in the WT compared to healthy parotid gland except for HbT and sO2. Comparing both tumors directly, the mean values of MSOT parameters were not different between PA and WT (all p > 0.05). Differences were seen for the maximal MSOT parameters. The maximal tumor values for 900 nm, HbR, HbT, and sO2 were lower in PA than in WT (all p < 0.05). This preliminary MSOT parotid tumor imaging study showed clear differences for PA or WT compared to healthy parotid tissue. Some MSOT characteristics of PA and WT were different but needed to be explored in larger studies.


Subject(s)
Parotid Neoplasms , Photoacoustic Techniques , Humans , Female , Parotid Neoplasms/diagnostic imaging , Parotid Neoplasms/pathology , Middle Aged , Male , Pilot Projects , Prospective Studies , Photoacoustic Techniques/methods , Adult , Aged , Hemoglobins/analysis , Hemoglobins/metabolism , Adenolymphoma/diagnostic imaging , Adenolymphoma/pathology , Adenoma, Pleomorphic/diagnostic imaging , Adenoma, Pleomorphic/pathology , Tomography/methods , Parotid Gland/diagnostic imaging , Parotid Gland/pathology
3.
Physiol Meas ; 45(5)2024 May 21.
Article in English | MEDLINE | ID: mdl-38697210

ABSTRACT

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Subject(s)
Artifacts , Electric Impedance , Signal Processing, Computer-Assisted , Tomography , Humans , Tomography/methods , Signal-To-Noise Ratio , Adult , Wavelet Analysis , Cardiovascular System , Infant, Newborn
4.
Methods Cell Biol ; 187: 139-174, 2024.
Article in English | MEDLINE | ID: mdl-38705623

ABSTRACT

Array tomography (AT) allows one to localize sub-cellular components within the structural context of cells in 3D through the imaging of serial sections. Using this technique, the z-resolution can be improved physically by cutting ultra-thin sections. Nevertheless, conventional immunofluorescence staining of those sections is time consuming and requires relatively large amounts of costly antibody solutions. Moreover, epitopes are only readily accessible at the section's surface, leaving the volume of the serial sections unlabeled. Localization of receptors at neuronal synapses in 3D in their native cellular ultrastructural context is important for understanding signaling processes. Here, we present in vivo labeling of receptors via fluorophore-coupled tags in combination with super-resolution AT. We present two workflows where we label receptors at the plasma membrane: first, in vivo labeling via microinjection with a setup consisting of readily available components and self-manufactured microscope table equipment and second, live receptor labeling by using a cell-permeable tag. To take advantage of a near-to-native preservation of tissues for subsequent scanning electron microscopy (SEM), we also apply high-pressure freezing and freeze substitution. The advantages and disadvantages of our workflows are discussed.


Subject(s)
Synapses , Tomography , Animals , Synapses/metabolism , Synapses/ultrastructure , Tomography/methods , Imaging, Three-Dimensional/methods , Staining and Labeling/methods , Mice , Microscopy, Electron, Scanning/methods , Fluorescent Dyes/chemistry , Microinjections/methods , Neurons/metabolism , Rats
5.
Biosensors (Basel) ; 14(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38785690

ABSTRACT

Magnetic Induction Tomography (MIT) is a non-invasive imaging technique used for dynamic monitoring and early screening of cerebral hemorrhage. Currently, there is a significant challenge in cerebral hemorrhage MIT due to weak detection signals, which seriously affects the accuracy of the detection results. To address this issue, a dual-plane enhanced coil was proposed by combining the target field method with consideration of the spatial magnetic field attenuation pattern within the imaging target region. Simulated detection models were constructed using the proposed coil and cylindrical coil as excitation coils, respectively, and simulation imaging tests were conducted using the detection results. The simulation results indicate that compared to the cylindrical coil, the proposed coil enhances the linearity of the magnetic field within the imaging target region by 60.43%. Additionally, it effectively enhances the detection voltage and phase values. The simulation results of hemorrhage detection show that the proposed coil improves the accuracy of hemorrhage detection by 18.26%. It provides more precise detection results, offering a more reliable solution for cerebral hemorrhage localization and detection.


Subject(s)
Cerebral Hemorrhage , Cerebral Hemorrhage/diagnostic imaging , Humans , Tomography , Computer Simulation
6.
Nat Commun ; 15(1): 4228, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762498

ABSTRACT

Cross-modal analysis of the same whole brain is an ideal strategy to uncover brain function and dysfunction. However, it remains challenging due to the slow speed and destructiveness of traditional whole-brain optical imaging techniques. Here we develop a new platform, termed Photoacoustic Tomography with Temporal Encoding Reconstruction (PATTERN), for non-destructive, high-speed, 3D imaging of ex vivo rodent, ferret, and non-human primate brains. Using an optimally designed image acquisition scheme and an accompanying machine-learning algorithm, PATTERN extracts signals of genetically-encoded probes from photobleaching-based temporal modulation and enables reliable visualization of neural projection in the whole central nervous system with 3D isotropic resolution. Without structural and biological perturbation to the sample, PATTERN can be combined with other whole-brain imaging modalities to acquire the whole-brain image with both high resolution and morphological fidelity. Furthermore, cross-modal transcriptome analysis of an individual brain is achieved by PATTERN imaging. Together, PATTERN provides a compatible and versatile strategy for brain-wide cross-modal analysis at the individual level.


Subject(s)
Brain , Ferrets , Imaging, Three-Dimensional , Photoacoustic Techniques , Animals , Brain/diagnostic imaging , Photoacoustic Techniques/methods , Imaging, Three-Dimensional/methods , Mice , Algorithms , Machine Learning , Tomography/methods , Image Processing, Computer-Assisted/methods , Rats , Male
8.
Urolithiasis ; 52(1): 65, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630281

ABSTRACT

Extracorporeal shock wave lithotripsy (ESWL) is a safe and efficient treatment option for urinary stone disease. The overall stone-free rate (SFR) varies significantly. This study aimed to assess the influence of stone size, location, stone density, and skin-to-stone distance (SSD), on the outcome of ESWL. We assessed whether pre-treatment non-contrast-enhanced CT scan (NCCT) confers significant advantages compared to kidney-ureter-bladder film (KUB) only. We reviewed the medical records of 307 cases (165 men, 142 women) with renal and ureteral stones treated consecutively at our institution with ESWL between 2020 and 2023. 44 of these underwent a NCCT. The outcome of ESWL was defined in two ways: visible stone fragmentation on KUB, and the need for further treatment. Overall success of fragmentation was 85% (261 patients). 61% of patients (n = 184) didn't need any further treatment. Stone size and location correlated significantly with treatment outcomes regarding the need for further treatment (p = 0.004) and stone fragmentation (p = 0.016), respectively. Unlike mean SSD (p = 0.462), the mean attenuation value (MAV) significantly correlated with the need for retreatment (p = 0.016). MAV seems to be a better predictor of treatment success (AUC of the ROC curve: 0.729), compared to stone size (AUC: 0.613). The difference between groups (with and without NCCT) in both treatment outcomes did not reach statistical significance. During decision-making, information regarding SSD and MAV can be useful in more dubious scenarios. However, it appears that their inclusion doesn't provide substantial advantages when compared to relying solely on KUB.


Subject(s)
Lithotripsy , Ureteral Calculi , Male , Humans , Female , Retrospective Studies , Ureteral Calculi/diagnostic imaging , Ureteral Calculi/therapy , Kidney , Computers , Tomography
9.
Waste Manag ; 182: 215-224, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38670005

ABSTRACT

Incidents of waste and biofuel fires are common at all stages of the waste recycling chain and have grave implications for business, employees, firefighters, society, and environment. An early detection of waste and biofuel fires in the smouldering stage could save precious lives, resources, and our environment. Existing fire detection methodologies e.g. handheld temperature sensors, IR cameras, gas sensors, and video and satellite-based monitoring techniques have inherent limitations to efficiently detect smouldering fires. An attempt was made to explore the potential of electrical resistivity tomography (ERT) as an alternate tool to address the problem. In the experiments an externally powered resistive wire was employed to initiate the smouldering fire inside the test material (wood pellets, wood shavings, wood fines). Time series of ERT that followed the initiation and development of smouldering were recorded using an automated monitoring instrument setup. The actual geometry of the experimental sample container and electrode setup was integrated in the 3D finite element method (FEM) model grid to perform inverse numerical modelling (inversion) and to develop resistivity tomographic images. The study shows a sharp increase in ratio of resistivity (R/Ro ≥ 50 %) in the test material in the region of smouldering hotspot and demonstrates the potential use of ERT technique for the detection of smouldering hotspots in silos and pile storage of organic material such as wood-based fuels, wood waste, coal, municipal solid waste (MSW), recyclables etc. More research is however required for enabling the use of this technique at the practical scale for different storage conditions.


Subject(s)
Wood , Fires , Recycling/methods , Tomography/methods , Refuse Disposal/methods , Biofuels/analysis
10.
Medicina (B Aires) ; 84(2): 359-363, 2024.
Article in English | MEDLINE | ID: mdl-38683525

ABSTRACT

The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.


La prueba de apnea es una técnica diagnóstica ampliamente utilizada para la evaluación de la muerte cerebral, con el objetivo de demostrar la ausencia de impulso respiratorio debido a la hipercapnia. La variante de la prueba de apnea con insuflación de oxígeno traqueal (I-AT) implica desconectar al paciente de la ventilación mecánica invasiva (iVM) durante aproximadamente 8 minutos, manteniendo la oxigenación mediante un catéter de insuflación. Esta prueba respalda el diagnóstico de muerte cerebral cuando se determina un aumento de la PaCO 2 superior a 20 mmHg en comparación con el valor inicial o un nivel de PaCO 2 superior a 60 mmHg al final de la prueba. En nuestra serie de casos, la implementación de la tomografía de impedancia eléctrica (EIT) reveló que la prueba de apnea con presión positiva continua (CPAPAT) mitiga eficazmente el colapso pulmonar. Este enfoque resulta en una mejora en la tensión pulmonar en comparación con la desconexión de iMV, demostrando su relevancia en el contexto de potenciales donantes de pulmones.


Subject(s)
Electric Impedance , Lung Volume Measurements , Humans , Male , Female , Lung Volume Measurements/methods , Middle Aged , Apnea/physiopathology , Brain Death/physiopathology , Brain Death/diagnosis , Brain Death/diagnostic imaging , Adult , Tomography/methods , Continuous Positive Airway Pressure , Lung/diagnostic imaging , Lung/physiopathology , Aged
11.
Physiol Meas ; 45(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38599226

ABSTRACT

Objective.Making up one of the largest shares of diagnosed cancers worldwide, skin cancer is also one of the most treatable. However, this is contingent upon early diagnosis and correct skin cancer-type differentiation. Currently, methods for early detection that are accurate, rapid, and non-invasive are limited. However, literature demonstrating the impedance differences between benign and malignant skin cancers, as well as between different types of skin cancer, show that methods based on impedance differentiation may be promising.Approach.In this work, we propose a novel approach to rapid and non-invasive skin cancer diagnosis that leverages the technologies of difference-based electrical impedance tomography (EIT) and graphene electronic tattoos (GETs).Main results.We demonstrate the feasibility of this first-of-its-kind system using both computational numerical and experimental skin phantom models. We considered variations in skin cancer lesion impedance, size, shape, and position relative to the electrodes and evaluated the impact of using individual and multi-electrode GET (mGET) arrays. The results demonstrate that this approach has the potential to differentiate based on lesion impedance, size, and position, but additional techniques are needed to determine shape.Significance.In this way, the system proposed in this work, which combines both EIT and GET technology, exhibits potential as an entirely non-invasive and rapid approach to skin cancer diagnosis.


Subject(s)
Electric Impedance , Graphite , Phantoms, Imaging , Skin Neoplasms , Tomography , Graphite/chemistry , Tomography/instrumentation , Tomography/methods , Skin Neoplasms/diagnosis , Skin Neoplasms/diagnostic imaging , Humans , Electrodes , Tattooing
12.
Crit Care ; 28(1): 124, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38627745

ABSTRACT

Extracorporeal Carbon Dioxide Removal (ECCO2R) is used in acute respiratory distress syndrome (ARDS) patients to facilitate lung-protective ventilatory strategies. Electrical Impedance Tomography (EIT) allows individual, non-invasive, real-time, bedside, radiation-free imaging of the lungs, providing global and regional dynamic lung analyses. To provide new insights for future ECCO2R research in ARDS, we propose a potential application of EIT to personalize End-Expiratory Pressure (PEEP) following each reduction in tidal volume (VT), as demonstrated in an illustrative case. A 72-year-old male with COVID-19 was admitted to the ICU for moderate ARDS. Monitoring with EIT was started to determine the optimal PEEP value (PEEPEIT), defined as the intersection of the collapse and overdistention curves, after each reduction in VT during ECCO2R. The identified PEEPEIT values were notably low (< 10 cmH2O). The decrease in VT associated with PEEPEIT levels resulted in improved lung compliance, reduced driving pressure and a more uniform ventilation pattern. Despite current Randomized Controlled Trials showing that ultra-protective ventilation with ECCO2R does not improve survival, the applicability of universal ultra-protective ventilation settings for all patients remains a subject of debate. Inappropriately set PEEP levels can lead to alveolar collapse or overdistension, potentially negating the benefits of VT reduction. EIT facilitates real-time monitoring of derecruitment associated with VT reduction, guiding physicians in determining the optimal PEEP value after each decrease in tidal volume. This original description of using EIT under ECCO2R to adjust PEEP at a level compromising between recruitability and overdistention could be a crucial element for future research on ECCO2R.


Subject(s)
Positive-Pressure Respiration , Respiratory Distress Syndrome , Male , Humans , Aged , Electric Impedance , Positive-Pressure Respiration/methods , Lung , Tomography, X-Ray Computed , Respiratory Distress Syndrome/therapy , Tidal Volume , Tomography/methods
13.
Phys Med Biol ; 69(11)2024 May 14.
Article in English | MEDLINE | ID: mdl-38636505

ABSTRACT

Objective.Pharmacokinetic parametric images obtained through dynamic fluorescence molecular tomography (DFMT) has ability of capturing dynamic changes in fluorescence concentration, thereby providing three-dimensional metabolic information for applications in biological research and drug development. However, data processing of DFMT is time-consuming, involves a vast amount of data, and the problem itself is ill-posed, which significantly limits the application of pharmacokinetic parametric images reconstruction. In this study, group sparse-based Taylor expansion method is proposed to address these problems.Approach.Firstly, Taylor expansion framework is introduced to reduce time and computational cost. Secondly, group sparsity based on structural prior is introduced to improve reconstruction accuracy. Thirdly, alternating iterative solution based on accelerated gradient descent algorithm is introduced to solve the problem.Main results.Numerical simulation andin vivoexperimental results demonstrate that, in comparison to existing methods, the proposed approach significantly enhances reconstruction speed without a degradation of quality, particularly when confronted with background fluorescence interference from other organs.Significance.Our research greatly reduces time and computational cost, providing strong support for real-time monitoring of liver metabolism.


Subject(s)
Image Processing, Computer-Assisted , Liver , Liver/diagnostic imaging , Liver/metabolism , Image Processing, Computer-Assisted/methods , Animals , Tomography/methods , Mice , Optical Imaging/methods , Algorithms , Fluorescence
14.
Phys Med Biol ; 69(11)2024 May 14.
Article in English | MEDLINE | ID: mdl-38640922

ABSTRACT

Objective.Modern medical imaging plays a vital role in clinical practice, enabling non-invasive visualization of anatomical structures. Dynamic contrast enhancement (DCE) imaging is a technique that uses contrast agents to visualize blood flow dynamics in a time-resolved manner. It can be applied to different modalities, such as computed tomography (CT) and electrical impedance tomography (EIT). This study aims to develop a common theoretical and practical hemodynamic extraction basis for DCE modelling across modalities, based on the gamma-variate function.Approach.The study introduces a framework to generate time-intensity curves for multiple DCE imaging modalities from user-defined hemodynamic parameters. Thus, extensive datasets were simulated for both DCE-CT and EIT, representing different hemodynamic scenarios. Additionally, gamma-variate extensions to account for several physiological effects were detailed in a modality-agnostic manner, and three corresponding fitting strategies, namely nonlinear, linear, and a novel hybrid approach, were implemented and compared on the basis of accuracy of parameter estimation, first pass reconstruction, speed of computation, and failure rate.Main results.As a result, we found the linear method to be the most modality-dependent, exhibiting the greatest bias, variance and failure rates, although remaining the fastest alternative. The hybrid method at least matches the state-of-the-art nonlinear method's accuracy, while improving its robustness and speed by 10 times.Significance.Our research suggests that the hybrid method may bring noteworthy accuracy and efficiency improvements in handling the high-dimensionality of DCE imaging in general, being a step towards real-time processing. Moreover, our generative model presents a potential asset to produce benchmarking and data augmentation datasets across modalities.


Subject(s)
Contrast Media , Electric Impedance , Image Processing, Computer-Assisted , Tomography , Tomography/methods , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Humans , Hemodynamics
15.
Phys Med Biol ; 69(11)2024 May 20.
Article in English | MEDLINE | ID: mdl-38648803

ABSTRACT

Objective.We present the first fully two-dimensional attenuation imaging technique developed for pulse-echo ultrasound systems. Unlike state-of-the-art techniques, which use line-by-line acquisitions, our method uses steered emissions to constrain attenuation values at each location with multiple crossing wave paths, essential to resolve the spatial variations of this tissue property.Approach.At every location, we compute normalized cross-correlations between the beamformed images that are obtained from emissions at different steering angles. We demonstrate that their log-amplitudes provide the changes between attenuation-induced amplitude losses undergone by the different incident waves. This allows us to formulate a linear tomographic problem, which we efficiently solve via a Tikhonov-regularized least-squares approach.Main results.The performance of our tomography technique is first validated in numerical examples and then experimentally demonstrated in custom-made tissue-mimicking phantoms with inclusions of varying size, echogenicity, and attenuation. We show that this technique is particularly good at resolving lateral variations in tissue attenuation and remains accurate in media with varying echogenicity.Significance.Based on a similar principle, this method can be easily combined with computed ultrasound tomography in echo mode for speed-of-sound imaging, paving the way towards a multi-modal ultrasound tomography framework characterizing multiple acoustic tissue properties simultaneously.


Subject(s)
Phantoms, Imaging , Tomography , Ultrasonography , Ultrasonography/methods , Tomography/methods , Image Processing, Computer-Assisted/methods
16.
Respir Res ; 25(1): 179, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664685

ABSTRACT

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Subject(s)
Electric Impedance , Tomography , Ventilator Weaning , Humans , Ventilator Weaning/methods , Male , Female , Middle Aged , Aged , Tomography/methods , Monitoring, Physiologic/methods , Adult , Respiration, Artificial/methods , Respiration , Aged, 80 and over , Lung/physiopathology , Lung/diagnostic imaging , Lung/physiology
17.
Zhonghua Yi Xue Za Zhi ; 104(15): 1247-1252, 2024 Apr 16.
Article in Chinese | MEDLINE | ID: mdl-38637164

ABSTRACT

Acute respiratory distress syndrome (ARDS) is a common and critical clinical condition characterized by diffuse damage to the lung interstitium, alveoli, and increased permeability of pulmonary blood vessels. CT can be used to assess the imaging features, severity, and prediction of ARDS, but it requires patient transportation to the CT room and is only a static examination. Electrical impedance tomography (EIT) is an increasingly widely used monitoring tool in clinical applications in recent years. It enables continuous real-time assessment of lung ventilation distribution at the bedside and has high clinical value in optimizing mechanical ventilation parameters for critically ill patients. This article introduces the basic principles of EIT and how to better utilize EIT technology to guide mechanical ventilation treatment for ARDS patients.


Subject(s)
Respiration, Artificial , Respiratory Distress Syndrome , Humans , Respiration, Artificial/methods , Electric Impedance , Tomography/methods , Respiratory Distress Syndrome/therapy , Tomography, X-Ray Computed/methods , Lung
18.
Gen Dent ; 72(3): 50-55, 2024.
Article in English | MEDLINE | ID: mdl-38640006

ABSTRACT

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Subject(s)
Bone Density , Mandibular Fractures , Humans , Retrospective Studies , Bone Density/physiology , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Tomography, X-Ray Computed/methods , Tomography
19.
Sci Rep ; 14(1): 9669, 2024 04 27.
Article in English | MEDLINE | ID: mdl-38671072

ABSTRACT

Serious blunt chest trauma usually induces hemothorax, pneumothorax, and rib fractures. More studies have claimed that early video-assisted thoracoscopic surgery with surgical stabilization of rib fractures (SSRF) results in a good prognosis in patients with major trauma. This study aimed to verify the outcomes in patients with chest trauma whether SSRF was performed. Consecutive patients who were treated in a medical center in Taiwan, for traumatic events between January 2015 and June 2020, were retrospectively reviewed. This study focused on patients with major trauma and thoracic injuries, and they were divided into groups based on whether they received SSRF. We used electrical impedance tomography (EIT) to evaluate the change of ventilation conditions. Different scores used for the evaluation of trauma severity were also compared in this study. Among the 8396 patients who were included, 1529 (18.21%) had major trauma with injury severity score > 16 and were admitted to the intensive care unit initially. A total of 596 patients with chest trauma were admitted, of whom 519 (87%) survived. Younger age and a lower trauma score (including injury severity scale, new injury severity score, trauma and injury severity score, and revised trauma score) account for better survival rates. Moreover, 74 patients received SSRF. They had a shorter intensive care unit (ICU) stay (5.24, p = 0.045) and better performance in electrical impedance tomography (23.46, p < 0.001). In patients with major thoracic injury, older age and higher injury survival scale account for higher mortality rate. Effective surgical stabilization of rib fractures shortened the ICU stay and helped achieve better performance in EIT. Thoracoscope-assisted rib fixation is suggested in severe trauma cases.


Subject(s)
Electric Impedance , Rib Fractures , Thoracic Injuries , Humans , Rib Fractures/surgery , Rib Fractures/diagnostic imaging , Female , Male , Middle Aged , Thoracic Injuries/surgery , Thoracic Injuries/diagnostic imaging , Adult , Retrospective Studies , Aged , Treatment Outcome , Thoracic Surgery, Video-Assisted/methods , Injury Severity Score , Tomography/methods
20.
Eur Respir J ; 63(4)2024 Apr.
Article in English | MEDLINE | ID: mdl-38636970

ABSTRACT

BACKGROUND: Up to 50% of those attending for low-dose computed tomography screening for lung cancer continue to smoke and co-delivery of smoking cessation services alongside screening may maximise clinical benefit. Here we present data from an opt-out co-located smoking cessation service delivered alongside the Yorkshire Lung Screening Trial (YLST). METHODS: Eligible YLST participants were offered an immediate consultation with a smoking cessation practitioner (SCP) at their screening visit with ongoing smoking cessation support over subsequent weeks. RESULTS: Of 2150 eligible participants, 1905 (89%) accepted the offer of an SCP consultation during their initial visit, with 1609 (75%) receiving ongoing smoking cessation support over subsequent weeks. Uptake of ongoing support was not associated with age, ethnicity, deprivation or educational level in multivariable analyses, although men were less likely to engage (adjusted OR (ORadj) 0.71, 95% CI 0.56-0.89). Uptake was higher in those with higher nicotine dependency, motivation to stop smoking and self-efficacy for quitting. Overall, 323 participants self-reported quitting at 4 weeks (15.0% of the eligible population); 266 were validated by exhaled carbon monoxide (12.4%). Multivariable analyses of eligible smokers suggested 4-week quitting was more likely in men (ORadj 1.43, 95% CI 1.11-1.84), those with higher motivation to quit and previous quit attempts, while those with a stronger smoking habit in terms of cigarettes per day were less likely to quit. CONCLUSIONS: There was high uptake for co-located opt-out smoking cessation support across a wide range of participant demographics. Protected funding for integrated smoking cessation services should be considered to maximise programme equity and benefit.


Subject(s)
Smoking Cessation , Tobacco Use Disorder , Male , Humans , Smoking Cessation/methods , Community Health Services , Lung , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL
...