Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.875
Filter
1.
BMC Med Imaging ; 24(1): 143, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38867154

ABSTRACT

OBJECTIVE: This study developed and validated a nomogram utilizing clinical and multi-slice spiral computed tomography (MSCT) features for the preoperative prediction of Ki-67 expression in stage IA lung adenocarcinoma. Additionally, we assessed the predictive accuracy of Ki-67 expression levels, as determined by our model, in estimating the prognosis of stage IA lung adenocarcinoma. MATERIALS AND METHODS: We retrospectively analyzed data from 395 patients with pathologically confirmed stage IA lung adenocarcinoma. A total of 322 patients were divided into training and internal validation groups at a 6:4 ratio, whereas the remaining 73 patients composed the external validation group. According to the pathological results, the patients were classified into high and low Ki-67 labeling index (LI) groups. Clinical and CT features were subjected to statistical analysis. The training group was used to construct a predictive model through logistic regression and to formulate a nomogram. The nomogram's predictive ability and goodness-of-fit were assessed. Internal and external validations were performed, and clinical utility was evaluated. Finally, the recurrence-free survival (RFS) rates were compared. RESULTS: In the training group, sex, age, tumor density type, tumor-lung interface, lobulation, spiculation, pleural indentation, and maximum nodule diameter differed significantly between patients with high and low Ki-67 LI. Multivariate logistic regression analysis revealed that sex, tumor density, and maximum nodule diameter were significantly associated with high Ki-67 expression in stage IA lung adenocarcinoma. The calibration curves closely resembled the standard curves, indicating the excellent discrimination and accuracy of the model. Decision curve analysis revealed favorable clinical utility. Patients with a nomogram-predicted high Ki-67 LI exhibited worse RFS. CONCLUSION: The nomogram utilizing clinical and CT features for the preoperative prediction of Ki-67 expression in stage IA lung adenocarcinoma demonstrated excellent performance, clinical utility, and prognostic significance, suggesting that this nomogram is a noninvasive personalized approach for the preoperative prediction of Ki-67 expression.


Subject(s)
Adenocarcinoma of Lung , Ki-67 Antigen , Lung Neoplasms , Neoplasm Staging , Nomograms , Humans , Ki-67 Antigen/metabolism , Male , Female , Middle Aged , Retrospective Studies , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/metabolism , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Adenocarcinoma of Lung/diagnostic imaging , Adenocarcinoma of Lung/metabolism , Adenocarcinoma of Lung/pathology , Adenocarcinoma of Lung/surgery , Prognosis , Aged , Tomography, Spiral Computed/methods , Adult
2.
BMC Med Imaging ; 24(1): 102, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724896

ABSTRACT

Precision and intelligence in evaluating the complexities of middle ear structures are required to diagnose auriculotemporal and ossicle-related diseases within otolaryngology. Due to the complexity of the anatomical details and the varied etiologies of illnesses such as trauma, chronic otitis media, and congenital anomalies, traditional diagnostic procedures may not yield accurate diagnoses. This research intends to enhance the diagnosis of diseases of the auriculotemporal region and ossicles by combining High-Resolution Spiral Computed Tomography (HRSCT) scanning with Deep Learning Techniques (DLT). This study employs a deep learning method, Convolutional Neural Network-UNet (CNN-UNet), to extract sub-pixel information from medical photos. This method equips doctors and researchers with cutting-edge resources, leading to groundbreaking discoveries and better patient healthcare. The research effort is the interaction between the CNN-UNet model and high-resolution Computed Tomography (CT) scans, automating activities including ossicle segmentation, fracture detection, and disruption cause classification, accelerating the diagnostic process and increasing clinical decision-making. The suggested HRSCT-DLT model represents the integration of high-resolution spiral CT scans with the CNN-UNet model, which has been fine-tuned to address the nuances of auriculotemporal and ossicular diseases. This novel combination improves diagnostic efficiency and our overall understanding of these intricate diseases. The results of this study highlight the promise of combining high-resolution CT scanning with the CNN-UNet model in otolaryngology, paving the way for more accurate diagnosis and more individualized treatment plans for patients experiencing auriculotemporal and ossicle-related disruptions.


Subject(s)
Ear Ossicles , Tomography, Spiral Computed , Humans , Tomography, Spiral Computed/methods , Ear Ossicles/diagnostic imaging , Deep Learning , Ear Diseases/diagnostic imaging , Temporal Bone/diagnostic imaging , Adult , Neural Networks, Computer
3.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
4.
Otolaryngol Head Neck Surg ; 170(6): 1561-1569, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38557958

ABSTRACT

OBJECTIVE: This study aims to use machine learning techniques together with radiomics methods to build a preoperative predictive diagnostic model from spiral computed tomography (CT) images. The model is intended for the differential diagnosis of common jaw cystic lesions. STUDY DESIGN: Retrospective, case-control study. SETTING: This retrospective study was conducted at Sun Yat-sen Memorial Hospital of Sun Yat-sen University (Guangzhou, Guangdong, China). All the data used to build the predictive diagnostic model were collected from 160 patients, who were treated at the Department of Oral and Maxillofacial Surgery at Sun Yat-sen Memorial Hospital of Sun Yat-sen University between 2019 and 2023. METHODS: We included a total of 160 patients in this study. We extracted 107 radiomic features from each patient's CT scan images. After a feature selection process, we chose 15 of these radiomic features to construct the predictive diagnostic model. RESULTS: Among the preoperative predictive diagnostic models built using 3 different machine learning methods (support vector machine, random forest [RF], and multivariate logistic regression), the RF model showed the best predictive performance. It demonstrated a sensitivity of 0.923, a specificity of 0.643, an accuracy of 0.825, and an area under the receiver operating characteristic curve of 0.810. CONCLUSION: The preoperative predictive model, based on spiral CT radiomics and machine learning algorithms, shows promising differential diagnostic capabilities. For common jaw cystic lesions, this predictive model has potential clinical application value, providing a scientific reference for treatment decisions.


Subject(s)
Machine Learning , Humans , Retrospective Studies , Female , Male , Diagnosis, Differential , Case-Control Studies , Adult , Middle Aged , Jaw Cysts/diagnostic imaging , Tomography, Spiral Computed/methods , Predictive Value of Tests , Aged , Radiomics
5.
Sci Rep ; 14(1): 9358, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38653758

ABSTRACT

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Subject(s)
Photons , Humans , Tomography, X-Ray Computed/methods , Cadaver , Rotation , Radiation Dosage , Tomography, Spiral Computed/methods
6.
Technol Health Care ; 32(S1): 313-320, 2024.
Article in English | MEDLINE | ID: mdl-38669497

ABSTRACT

BACKGROUND: With the widespread use of low-dose spiral computed tomography (LDCT) and increasing awareness of personal health, the detection rate of pulmonary nodules is steadily rising. OBJECTIVE: To evaluate the success rate and safety of two different models of Hook-Wire needle localization procedures for pulmonary small nodule biopsy. METHODS: Ninety-four cases with a total of 97 pulmonary small nodules undergoing needle localization biopsy were retrospectively analyzed. The cases were divided into two groups: Group A, using breast localization needle steel wire (Bard Healthcare Science Co., Ltd.); Group B, using disposable pulmonary nodule puncture needle (SensCure Biotechnology Co., Ltd.). All patients underwent video-assisted thoracoscopic surgery (VATS) for nodule removal on the same day after localization and biopsy. The puncture localization operation time, success rate, complications such as pulmonary hemorrhage, pneumothorax, hemoptysis, and postoperative comfort were observed and compared. RESULTS: In Group A, the average localization operation time for 97 nodules was 15.47 ± 5.31 minutes, with a success rate of 94.34%. The complication rate was 71.69% (12 cases of pneumothorax, 35 cases of pulmonary hemorrhage, 2 cases of hemoptysis), and 40 cases of post-localization discomfort were reported. In Group B, the average localization operation time was 25.32 ± 7.83 minutes, with a 100% success rate. The complication rate was 29.55% (3 cases of pneumothorax, 15 cases of pulmonary hemorrhage, 0 cases of hemoptysis), and 3 cases reported postoperative discomfort. According to the data analysis in this study, Group B had a lower incidence of puncture-related complications than Group A, along with a higher success rate and significantly greater postoperative comfort. CONCLUSIONS: The disposable pulmonary nodule puncture needle is safer and more effective in pulmonary small nodule localization biopsy, exhibiting increased comfort compared to the breast localization needle. Additionally, the incidence of complications is significantly lower.


Subject(s)
Solitary Pulmonary Nodule , Thoracic Surgery, Video-Assisted , Humans , Female , Male , Middle Aged , Retrospective Studies , Thoracic Surgery, Video-Assisted/methods , Thoracic Surgery, Video-Assisted/instrumentation , Solitary Pulmonary Nodule/surgery , Solitary Pulmonary Nodule/pathology , Solitary Pulmonary Nodule/diagnostic imaging , Aged , Adult , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Biopsy, Needle/methods , Biopsy, Needle/instrumentation , Needles , Operative Time , Tomography, Spiral Computed/methods
7.
Jpn J Radiol ; 42(6): 622-629, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38381250

ABSTRACT

PURPOSE: To evaluate the diagnostic accuracy of abdominal contrast-enhanced multi-slice spiral CT after oral diluted iodide in a time segment (post-ODI ACE-MSCT) for gastrointestinal fistula (GIF) in severe acute pancreatitis (SAP). MATERIALS AND METHODS: Patients with SAP who underwent both post-ODI ACE-MSCT and endoscopy/surgery from 2017 to 2023 were continuously retrospectively involved. Their demographic information and clinical features were recorded prospectively in an in-hospital database. Using endoscopy/surgery results as the reference standard, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of post-ODI ACE-MSCT for diagnosing GIF in SAP were calculated by a four-cell table. The consistency of the two diagnostic methods was evaluated by the Kappa test and McNemar's test. RESULTS: Using endoscopy/surgery as the reference standard, a total of 86 cases were divided into the GIF group (N = 52) and the non-GIF group (N = 34). Among the 52 cases of GIF, 88.5% (46/52) cases had a positive result and 11.5% (5/52) cases had a negative result of post-ODI ACE-MSCT for GIF. Among the 34 cases of non-GIF, 2.9% (1/34) case had a positive result and 97.1% (33/34) cases had a negative result of post-ODI ACE-MSCT for GIF. Post-ODI ACE-MSCT had a sensitivity of 88.5% (95% CI 75.9%-95.2%), a specificity of 97.1% (95% CI 82.9%-99.8%), a positive predictive value of 97.9% (95% CI 87.3%-99.9%), a negative predictive value of 84.6% (95% CI 68.8%-93.6%), and an accuracy of 91.9% (83.4%-96.4%). The kappa value was 0.834, and P < 0.001 by McNemar's test. There were no significant differences in diagnostic test characteristics between the two modalities. CONCLUSION: Post-ODI ACE-MSCT can diagnose GIF in SAP in a simple, noninvasive, and accurate way, and can provide earlier imaging evidence for clinical diagnosis and treatment.


Subject(s)
Contrast Media , Pancreatitis , Sensitivity and Specificity , Humans , Male , Female , Middle Aged , Retrospective Studies , Pancreatitis/diagnostic imaging , Tomography, Spiral Computed/methods , Aged , Adult , Administration, Oral , Intestinal Fistula/diagnostic imaging , Reproducibility of Results
8.
Pediatr Radiol ; 54(5): 758-763, 2024 05.
Article in English | MEDLINE | ID: mdl-38308740

ABSTRACT

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Subject(s)
Lens, Crystalline , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic , Thyroid Gland , Humans , Thyroid Gland/diagnostic imaging , Infant, Newborn , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/radiation effects , Radiography, Thoracic/methods , Radiography, Thoracic/instrumentation , Child, Preschool , Tomography, X-Ray Computed/methods , Tomography, Spiral Computed/methods
9.
Zhongguo Fei Ai Za Zhi ; 27(1): 13-24, 2024 Jan 20.
Article in Chinese | MEDLINE | ID: mdl-38296622

ABSTRACT

BACKGROUND: Low-dose spiral computed tomography (LDCT) has been recommended for lung cancer screening in high-risk populations. However, evidence from Chinese populations was limited due to the different criteria for high-risk populations and the short-term follow-up period. This study aimed to evaluate the effectiveness in Chinese adults based on the Lung Cancer Screening Program in Minhang District of Shanghai initiated in 2013. METHODS: A total of 26,124 subjects aged 40 years or above were enrolled in the Lung Cancer Screening Program during the period of 2013 and 2017. Results of LDCT examination, and screen-detected cancer cases in all participants were obtained from the Reporting System of the Lung Cancer Screening Program. The newly-diagnosed cases and their vital status up to December 31, 2020 were identified through a record linkage with the Shanghai Cancer Registry and the Shanghai Vital Statistics. Standardized incidence ratio (SIR) and 95%CI were calculated using the local population at ages of 40 or above as the reference. Proportions of early-stage cancer (stage 0-I), pathological types, and 5-year observed survival rates of lung cancer cases were estimated and compared between the cases derived from the screened and non-screened populations. Cox regression models were applied to evaluate the hazard ratio (HR) and 95%CI of LDCT screening with all-cause death of the lung cancer cases. RESULTS: The crude and age-standardized incidence of lung cancer in screened population were 373.3 (95%CI: 343.1-406.1) and 70.3 per 100,000 person-years, respectively, with an SIR of 1.8 (95%CI: 1.6-1.9), which was observed to decrease with following-up time. The early-stage cancer accounted for 49.4% of all lung cancer cases derived from the screened population, significantly higher than 38.4% in cases from the non-screened population during the same period (P<0.05). The proportion of lung adenocarcinoma (40.7% vs 35.9%) and 5-year survival rate (53.7% vs 41.5%) were also significantly higher in the cases from the screened population (all P<0.05). LDCT screening was associated with 30% (HR=0.7, 95%CI: 0.6-0.8) reduced all-cause deaths of the cases. CONCLUSIONS: The participants of the screening program are at high-risk of lung cancer. LDCT favors the early-detection of lung cancer and improves 5-year survival of the screened cases, indicating a great potential of LDCT in reducing the disease burden of lung cancer in Chinese populations.


Subject(s)
Lung Neoplasms , Adult , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/epidemiology , Tomography, X-Ray Computed , Early Detection of Cancer/methods , China/epidemiology , Tomography, Spiral Computed/methods , Mass Screening
10.
Med Phys ; 51(3): 1597-1616, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38227833

ABSTRACT

BACKGROUND: Multislice spiral computed tomography (MSCT) requires an interpolation between adjacent detector rows during backprojection. Not satisfying the Nyquist sampling condition along the z-axis results in aliasing effects, also known as windmill artifacts. These image distortions are characterized by bright streaks diverging from high contrast structures. PURPOSE: The z-flying focal spot (zFFS) is a well-established hardware-based solution that aims to double the sampling rate in longitudinal direction and therefore reduce aliasing artifacts. However, given the technical complexity of the zFFS, this work proposes a deep learning-based approach as an alternative solution. METHODS: We propose a supervised learning approach to perform a mapping between input projections and the corresponding rows required for double sampling in the z-direction. We present a comprehensive evaluation using both a clinical dataset obtained using raw data from 40 real patient scans acquired with zFFS and a synthetic dataset consisting of 100 simulated spiral scans using a phantom specifically designed for our problem. For the clinical dataset, we utilized 32 scans as training set and 8 scans as validation set, whereas for the synthetic dataset, we used 80 scans for training and 20 scans for validation purposes. Both qualitative and quantitative assessments are conducted on a test set consisting of nine real patient scans and six phantom measurements to validate the performance of our approach. A simulation study was performed to investigate the robustness against different scan configurations in terms of detector collimation and pitch value. RESULTS: In the quantitative comparison based on clinical patient scans from the test set, all network configurations show an improvement in the root mean square error (RMSE) of approximately 20% compared to neglecting the doubled longitudinal sampling by the zFFS. The results of the qualitative analysis indicate that both clinical and synthetic training data can reduce windmill artifacts through the application of a correspondingly trained network. Together with the qualitative results from the test set phantom measurements it is emphasized that a training of our method with synthetic data resulted in superior performance in windmill artifact reduction. CONCLUSIONS: Deep learning-based raw data interpolation has the potential to enhance the sampling in z-direction and thus minimize aliasing effects, as it is the case with the zFFS. Especially a training with synthetic data showed promising results. While it may not outperform zFFS, our method represents a beneficial solution for CT scanners lacking the necessary hardware components for zFFS.


Subject(s)
Artifacts , Deep Learning , Humans , Tomography, Spiral Computed/methods , Tomography Scanners, X-Ray Computed , Phantoms, Imaging , Image Processing, Computer-Assisted/methods , Algorithms
11.
J Comput Assist Tomogr ; 48(3): 491-497, 2024.
Article in English | MEDLINE | ID: mdl-38157266

ABSTRACT

OBJECTIVE: Salivary gland lesions show overlapping morphological findings and types of time/intensity curves. This research aimed to evaluate the role of 2-phase multislice spiral computed tomography (MSCT) texture analysis in differentiating between benign and malignant salivary gland lesions. METHODS: In this prospective study, MSCT was carried out on 90 patients. Each lesion was segmented on axial computed tomography (CT) images manually, and 33 texture features and morphological CT features were assessed. Logistic regression analysis was used to confirm predictors of malignancy ( P < 0.05 was considered to be statistically significant), followed by receiver operating characteristics analysis to assess the diagnostic performance. RESULTS: Univariate logistic regression analysis revealed that morphological CT features (shape, size, and invasion of adjacent tissues) and 17 CT texture parameters had significant differences between benign and malignant lesions ( P < 0.05). Multivariate binary logistic regression demonstrated that shape, invasion of adjacent tissues, entropy, and inverse difference moment were independent factors for malignant tumors. The diagnostic accuracy values of multivariate binary logistic models based on morphological parameters, CT texture features, and a combination of both were 87.8%, 90%, and 93.3%, respectively. CONCLUSIONS: Two-phase MSCT texture analysis was conducive to differentiating between malignant and benign neoplasms in the salivary gland, especially when combined with morphological CT features.


Subject(s)
Salivary Gland Neoplasms , Humans , Female , Male , Salivary Gland Neoplasms/diagnostic imaging , Salivary Gland Neoplasms/pathology , Middle Aged , Diagnosis, Differential , Adult , Aged , Prospective Studies , Young Adult , Adolescent , Radiographic Image Interpretation, Computer-Assisted/methods , Sensitivity and Specificity , Tomography, X-Ray Computed/methods , Aged, 80 and over , Reproducibility of Results , Multidetector Computed Tomography/methods , Tomography, Spiral Computed/methods , Salivary Glands/diagnostic imaging
12.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1010106

ABSTRACT

BACKGROUND@#Low-dose spiral computed tomography (LDCT) has been recommended for lung cancer screening in high-risk populations. However, evidence from Chinese populations was limited due to the different criteria for high-risk populations and the short-term follow-up period. This study aimed to evaluate the effectiveness in Chinese adults based on the Lung Cancer Screening Program in Minhang District of Shanghai initiated in 2013.@*METHODS@#A total of 26,124 subjects aged 40 years or above were enrolled in the Lung Cancer Screening Program during the period of 2013 and 2017. Results of LDCT examination, and screen-detected cancer cases in all participants were obtained from the Reporting System of the Lung Cancer Screening Program. The newly-diagnosed cases and their vital status up to December 31, 2020 were identified through a record linkage with the Shanghai Cancer Registry and the Shanghai Vital Statistics. Standardized incidence ratio (SIR) and 95%CI were calculated using the local population at ages of 40 or above as the reference. Proportions of early-stage cancer (stage 0-I), pathological types, and 5-year observed survival rates of lung cancer cases were estimated and compared between the cases derived from the screened and non-screened populations. Cox regression models were applied to evaluate the hazard ratio (HR) and 95%CI of LDCT screening with all-cause death of the lung cancer cases.@*RESULTS@#The crude and age-standardized incidence of lung cancer in screened population were 373.3 (95%CI: 343.1-406.1) and 70.3 per 100,000 person-years, respectively, with an SIR of 1.8 (95%CI: 1.6-1.9), which was observed to decrease with following-up time. The early-stage cancer accounted for 49.4% of all lung cancer cases derived from the screened population, significantly higher than 38.4% in cases from the non-screened population during the same period (P<0.05). The proportion of lung adenocarcinoma (40.7% vs 35.9%) and 5-year survival rate (53.7% vs 41.5%) were also significantly higher in the cases from the screened population (all P<0.05). LDCT screening was associated with 30% (HR=0.7, 95%CI: 0.6-0.8) reduced all-cause deaths of the cases.@*CONCLUSIONS@#The participants of the screening program are at high-risk of lung cancer. LDCT favors the early-detection of lung cancer and improves 5-year survival of the screened cases, indicating a great potential of LDCT in reducing the disease burden of lung cancer in Chinese populations.


Subject(s)
Adult , Humans , Lung Neoplasms/epidemiology , Tomography, X-Ray Computed , Early Detection of Cancer/methods , China/epidemiology , Tomography, Spiral Computed/methods , Mass Screening
13.
Rev. cuba. med ; 62(4)dic. 2023.
Article in Spanish | CUMED, LILACS | ID: biblio-1550894

ABSTRACT

Introducción: El neumoencéfalo (sinonimia: aerocele o neumatocele intracerebral), se define como la presencia de gas dentro de cualquiera de los compartimentos intracraneales (intraventricular, intraparenquimatosa, subaracnoidea, subdural y epidural). Objetivo: Describir los hallazgos clínicos, estudios complementarios, conducta terapéutica y evolución de un caso con neumoencéfalo como complicación de bloqueo regional epidural por radiculopatía lumbosacra. Presentación de caso: Se presentó un paciente masculino de 57 años de edad que comenzó con un cuadro súbito de desorientación, excitabilidad psicomotriz y convulsiones tónico-clónicas, a partir de una inyección epidural de metilprednisolona como método analgésico. Conclusiones: El caso presentado exhibió manifestaciones neurológicas inespecíficas, la aparición súbita posterior al proceder invasivo hizo sospechar en un evento neurológico agudo o fenómeno tromboembólico. Los estudios complementarios como la tomografía axial computarizada craneal simple, permitió su diagnóstico para tener una conducta consecuente. El manejo conservador del neumoencéfalo como complicación del uso de anestesia epidural, constituyó una conducta terapéutica eficaz y repercutió en la satisfactoria evolución del paciente(AU)


Introduction: Pneumocephalus (synonym: aerocele or intracerebral pneumatocele), is defined as the presence of gas within any of the intracranial compartments (intraventricular, intraparenchymal, subarachnoid, subdural and epidural). Objective: To describe the clinical findings, complementary studies, therapeutic conduct and evolution of a case with pneumocephalus as a complication of regional epidural block due to lumbosacral radiculopathy Case presentation: A 57-year-old male patient was presented who began with a sudden episode of disorientation, psychomotor excitability and tonic-clonic seizures, following an epidural injection of methylprednisolone as an analgesic method. Conclusions: The case presented exhibited non-specific neurological manifestations, the sudden appearance after the invasive procedure raised suspicion of an acute neurological event or thromboembolic phenomenon. Complementary studies such as simple cranial computed axial tomography, allowed its diagnosis to have a consistent conduct. The conservative management of pneumocephalus as a complication of the use of epidural anesthesia constituted an effective therapeutic approach and had an impact on the patient's satisfactory evolution(AU)


Subject(s)
Humans , Male , Middle Aged , Radiculopathy/complications , Methylprednisolone/therapeutic use , Pneumoencephalography/methods , Tomography, Spiral Computed/methods , Anesthesia, Epidural/methods
14.
Radiat Prot Dosimetry ; 199(12): 1295-1300, 2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37337642

ABSTRACT

We investigated the effect of electrocardiographic (ECG) mA-modulation of ECG-gated scans of computed tomography (CTA) on radiation dose and image noise at high heart rates (HR) above 100 bpm between helical pitches (HP) 0.16 and 0.24. ECG mA-modulation range during ECG-gated CTA is 50-100 mA, the phase setting is 40-60% and the scan range is 90 mm for clinical data during HR for 90, 120 and 150 bpm. Radiation dose and image noise in Housfield units are measured for CT equipment during HR for 90, 120 and 150 bpm between HP 0.16 and 0.24. ECG mA-modulation, dose reduction ratio for HR 90, 120 and 150 bpm are 19.1, 13.4 and 8.7% at HP 0.16 and 17.1, 13.3 and 7.7% at HP 0.24, respectively. No significant differences were observed in image noise between both HP. Dose reductions of 8-24% are achieved with ECG mA-modulation during ECG-gated CCTA scan, which is beneficial even in high HR more than 100 bpm.


Subject(s)
Pediatrics , Tomography, Spiral Computed , Humans , Child , Coronary Angiography/methods , Tomography, Spiral Computed/methods , Heart Rate , Radiation Dosage , Electrocardiography , Tomography, X-Ray Computed
15.
Cancer Med ; 12(11): 12050-12064, 2023 06.
Article in English | MEDLINE | ID: mdl-37248730

ABSTRACT

BACKGROUND: Many people were found with pulmonary nodules during physical examinations. It is of great practical significance to discriminate benign and malignant nodules by using data mining technology. METHODS: The subjects' demographic data, baseline examination results, and annual follow-up low-dose spiral computerized tomography (LDCT) results were recorded. The findings from annual physical examinations of positive nodules, including highly suspicious nodules and clinically tentative benign nodules, was analyzed. The extreme gradient boosting (XGBoost) model was constructed and the Grid Search CV method was used to select the super parameters. External unit data were used as an external validation set to evaluate the generalization performance of the model. RESULTS: A total of 135,503 physical examinees were enrolled. Baseline testing found that 27,636 (20.40%) participants had clinically tentative benign nodules and 611 (0.45%) participants had highly suspicious nodules. The proportion of highly suspicious nodules in participants with negative baseline was about 0.12%-0.46%, which was lower than the baseline level except the follow-up of >5 years. In the 27,636 participants with clinically tentative benign nodules, only in the first year of LDCT re-examination was the proportion of highly suspicious nodules (1.40%) significantly greater than that of baseline screening (0.45%) (p < 0.001), and the proportion of highly suspicious nodules was not different between the baseline screening and other follow-up years (p > 0.05). Furthermore, 322 cases with benign nodules and 196 patients with malignant nodules confirmed by surgery and pathology were compared. A model and the top 15 most important clinical variables were determined by XGBoost algorithm. The area under the curve (AUC) of the model was 0.76 [95% CI: 0.67-0.84], and the accuracy was 0.75. The sensitivity and specificity of the model under this threshold were 0.78 and 0.73, respectively. In the validation of model using external data, the AUC was 0.87 and the accuracy was 0.80. The sensitivity and specificity were 0.83 and 0.77, respectively. CONCLUSIONS: It is important that pulmonary nodules could be more accurately identified at the first LDCT examination. A model with 15 variables which are routinely measured in the clinic could be helpful to distinguish benign and malignant nodules. It could help the radiological team issue a more accurate report; and it may guide the clinical team regarding LDCT follow-up.


Subject(s)
Lung Neoplasms , Multiple Pulmonary Nodules , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Multiple Pulmonary Nodules/diagnostic imaging , Multiple Pulmonary Nodules/pathology , Tomography, Spiral Computed/methods , Sensitivity and Specificity , Machine Learning , Early Detection of Cancer
17.
Radiat Prot Dosimetry ; 199(3): ncac257 179 186-186, 2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36521836

ABSTRACT

PURPOSE: to assess overranging (OR) as a function of pitch, collimation and rotation time for three commonly used CT models in France. METHODS: OR was measured using XR-SP2 Gafchromic films (Ashland, USA) and computed from exposure data for three widely used CT models in France. The impact of collimation, pitch and rotation time on OR was analyzed while comparing the three CT models. RESULTS: for a typical head protocol, measured OR was found to be equal to 1.64 cm for CT scan A, 0.5 cm for CT scan B and 3.44 cm for CT scan C. OR values were respectively of 4.47, 3.24 and 7.81 cm for the typical chest protocol and the 3 CT models. OR was lowest at pitch values <1 for CT scan A, while it linearly increased with pitch for CT scan B and was lowest for high pitch values for CT scan C. Additionally, OR increase with collimation (24 mm to 38.4 mm) was most pronounced for CT scan B (factor of 2.2 for low pitch (0.5) and 2.8 for high pitch (1.2)) while it increased linearly regardless of the pitch for CT scans A and C. Rotation time also proved to slightly affect OR mainly for CT scan B (up to 2.2 mm). CONCLUSION: the present study shows that overranging remains an issue in modern CT scanners with large disparities across the vendors.


Subject(s)
Tomography, Spiral Computed , Tomography, X-Ray Computed , Tomography, Spiral Computed/methods , Radiation Dosage , Rotation , Tomography, X-Ray Computed/methods , France
18.
Contrast Media Mol Imaging ; 2022: 3282409, 2022.
Article in English | MEDLINE | ID: mdl-36247848

ABSTRACT

The aim of this study was to explore the application value of multislice spiral computerized tomography (MSCT) and magnetic resonance imaging (MRI) under intelligent algorithm in the diagnosis of occult fractures of the knee joint (OFKJ). 47 patients with negative X-ray examination and suspected fracture were included for this research. According to the examination methods, the patients were divided into the MSCT group and MRI group. The diagnostic results of the two methods were compared, and then compared with the traditional algorithm to explore their superiorities. The results demonstrated that the algorithm applied in this study had a clearer segmentation than traditional algorithms, and it run significantly faster than other algorithms. The results of MSCT, MRI, and pathological examination were all different, but which was of no statistical significance, P > 0.05. The specificity, accuracy, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) of MSCT were 83%, 96%, 94%, and 98%, respectively; and its coincidence rate, missed diagnosis rate, and misdiagnosis rate were 98.20%, 1.60%, and 0.20%, respectively. Compared with MRI, the differences were significant statistically, P < 0.05. The segmentation effect of MSCT was closer to the standard segmentation, with the higher efficiency. MSCT under the intelligent algorithm produced the better diagnostic performance and the higher detection rate than MRI in diagnosing OFKJ. It could be used for clinical auxiliary diagnosis and evaluation of OFKJ, deserving an application value.


Subject(s)
Fractures, Closed , Algorithms , Artificial Intelligence , Fractures, Closed/diagnostic imaging , Humans , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Tomography, Spiral Computed/methods
19.
Contrast Media Mol Imaging ; 2022: 9633527, 2022.
Article in English | MEDLINE | ID: mdl-36105451

ABSTRACT

In order to solve the problem of CT reconstruction imaging, this paper presents a study on the clinical application of preanesthesia in patients with tracheal stenosis. Patients with tracheal stenosis and multislice spiral CT virtual endoscopy (CTVE) were diagnosed, and their application effects were analyzed. Methods. 60 patients with tracheal stenosis were selected for clinical observation. The patients were given tracheal stenosis examination and multislice spiral CT virtual endoscopy. The examination results of the two groups were compared and analyzed by statistical methods. Results. There was no significant difference in the detection rate, sensitivity, accuracy, and specificity between the two groups (P > 0.05). Conclusion. Multislice spiral CT virtual endoscopy combined with a fiberoptic bronchoscope for clinical diagnosis of tracheal stenosis can complement each other. Combined use can effectively improve the detection consistency, and is safe and reliable. It can be used as an effective means for the diagnosis of tracheal stenosis.


Subject(s)
Anesthesia , Tracheal Stenosis , Humans , Tomography, Spiral Computed/methods , Tracheal Stenosis/diagnostic imaging , Tracheal Stenosis/surgery
20.
Zhongguo Fei Ai Za Zhi ; 25(9): 678-683, 2022 Sep 20.
Article in Chinese | MEDLINE | ID: mdl-36172733

ABSTRACT

Lung cancer is one of the malignant tumors with the highest morbidity and mortality in the world. The low early diagnosis rate and poor prognosis of patients have caused serious social burden. Regular screening of high-risk population by low-dose spiral computed tomography (LDCT) can significantly improve the early diagnosis rate of lung cancer and bring new opportunities for the diagnosis and treatment of lung cancer. In recent years, LDCT lung cancer screening programs have been carried out in many countries around the world and achieved good results, but there are still some controversies in the selection of screening subjects, screening frequency, cost effectiveness and other aspects. In this paper, the key factors of LDCT lung cancer screening, screening effect, pulmonary nodule management and artificial intelligence contribution to the development of LDCT will be reviewed, and the application progress of LDCT in lung cancer screening will be discussed.
.


Subject(s)
Early Detection of Cancer , Lung Neoplasms , Tomography, Spiral Computed , Artificial Intelligence , Early Detection of Cancer/methods , Humans , Lung Neoplasms/diagnostic imaging , Radiation Dosage , Tomography, Spiral Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...