Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 11.624
Filter
1.
Prog Orthod ; 25(1): 22, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38825612

ABSTRACT

BACKGROUND: The aim of the present study was to investigate qualitatively and quantitatively the elution of substances from polyester-urethane (Invisalign™) aligners and resin composite attachments (Tetric EvoFlow) in vivo. METHODS: Patients (n = 11) treated with the aligners and attachments (16 per patient, without other composite restorations) for an average of 20 months, who were planned for attachment removed were enrolled in the study. Patients were instructed to rinse with 50 mL of distilled water upon entry and the rinsing solution was collected (before removal). Then, the attachments were removed with low-speed tungsten carbide burs for adhesive residue removal, a thorough water rinsing was performed immediately after the grinding process to discard grinding particle residues, and subsequently, after a second water-rinsing the solution was collected for analysis (after removal). The rinsing solutions were analyzed for targeted (LC-MS/MS: Bis-GMA, DCDMA, UDMA, BPA) and untargeted (LC-HRMS: screening of leached species and their degradation products) compounds. RESULTS: Targeted analysis revealed a significant reduction in BPA after attachment removal (4 times lower). Bis-GMA, DCDMA, UDMA were below the detection limit before removal but were all detectable after removal with Bis-GMA and UDMA at quantifiable levels. Untargeted analysis reviled the presence of mono-methacrylate transformation products of Bis-GMA (Bis-GMA-M1) and UDMA (UDMA-M1), UDMA without methacrylate moieties (UDMA-M2), and 4-(dimethylamino) benzoic acid (DMAB), the degradation product of the photo-initiator ethyl-4-(dimethylamino) benzoate (EDMAB), all after attachment removal. Several amino acids and endogenous metabolites were also found both before and after removal. CONCLUSIONS: Elevated levels of BPA were traced instantaneously in patients treated with Invisalign™ and flowable resin composite attachments for the testing period. BPA was reduced after attachment removal, but residual monomers and resin degradation products were found after removal. Alternative resin formulations and attachment materials may be utilized to reduce eluents.


Subject(s)
Composite Resins , Methacrylates , Polyurethanes , Humans , Polyurethanes/chemistry , Composite Resins/chemistry , Female , Male , Methacrylates/chemistry , Saliva/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Adult , Orthodontic Appliances, Removable , Polyesters/chemistry , para-Aminobenzoates/analysis , Young Adult , Adolescent , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Tandem Mass Spectrometry , Chromatography, Liquid
2.
J Cell Mol Med ; 28(9): e18350, 2024 May.
Article in English | MEDLINE | ID: mdl-38700030

ABSTRACT

Mechanical force induces hypoxia in the pulpal area by compressing the apical blood vessels of the pulp, triggering pulpal inflammation during orthodontic tooth movement. However, this inflammation tends to be restorable. Macrophages are recognized as pivotal immunoreactive cells in the dental pulp. Whether they are involved in the resolution of pulpal inflammation in orthodontic teeth remains unclear. In this study, we investigated macrophage polarization and its effects during orthodontic tooth movement. It was demonstrated that macrophages within the dental pulp polarized to M2 type and actively participated in the process of pulpal inflammation resolution. Inflammatory reactions were generated and vascularization occurred in the pulp during orthodontic tooth movement. Macrophages in orthodontic pulp show a tendency to polarize towards M2 type as a result of pulpal hypoxia. Furthermore, by blocking M2 polarization, we found that macrophage M2 polarization inhibits dental pulp-secreting inflammatory factors and enhances VEGF production. In conclusion, our findings suggest that macrophages promote pulpal inflammation resolution by enhancing M2 polarization and maintaining dental health during orthodontic tooth movement.


Subject(s)
Dental Pulp , Inflammation , Macrophages , Tooth Movement Techniques , Dental Pulp/metabolism , Dental Pulp/pathology , Animals , Macrophages/metabolism , Inflammation/pathology , Inflammation/metabolism , Mice , Cell Polarity , Male , Vascular Endothelial Growth Factor A/metabolism , Pulpitis/pathology , Pulpitis/metabolism , Macrophage Activation
4.
BMC Oral Health ; 24(1): 538, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715004

ABSTRACT

BACKGROUND: The introduction of auxiliaries such as composite attachment has improved the force delivery of clear aligner (CA) therapy. However, the placement of the attachment may give rise to a flash, defined as excess resin around the attachment which may affect CA force delivery. This in vitro study aims to determine the differences in the force generated by the attachment in the presence or absence of flash in CA. MATERIALS AND METHODS: Tristar Trubalance aligner sheets were used to fabricate the CAs. Thirty-four resin models were 3D printed and 17 each, were bonded with ellipsoidal or rectangular attachments on maxillary right central incisors. Fuji Prescale pressure film was used to measure the force generated by the attachment of CA. The images of colour density produced on the films were processed using a calibrated pressure mapping system utilising image processing techniques and topographical force mapping to quantify the force. The force measurement process was repeated after the flash was removed from the attachment using tungsten-carbide bur on a slow-speed handpiece. RESULTS: The intraclass correlation coefficient showed excellent reliability (ICC = 0.96, 95% CI = 0.92-0.98). The average mean force exerted by ellipsoidal attachments with flash was 8.05 ± 0.16 N, while 8.11 ± 0.18 N was without flash. As for rectangular attachments, the average mean force with flash was 8.48 ± 0.27 N, while 8.53 ± 0.13 N was without flash. Paired t-test revealed no statistically significant difference in the mean force exerted by CA in the presence or absence of flash for both ellipsoidal (p = 0.07) and rectangular attachments (p = 0.41). Rectangular attachments generated statistically significantly (p < 0.001) higher mean force than ellipsoidal attachments for flash and without flash. CONCLUSION: Although rectangular attachment generated a significantly higher force than ellipsoidal attachment, the force generated by both attachments in the presence or absence of flash is similar (p > 0.05).


Subject(s)
Tooth Movement Techniques , Humans , In Vitro Techniques , Tooth Movement Techniques/instrumentation , Dental Stress Analysis , Orthodontic Appliance Design , Composite Resins/chemistry , Printing, Three-Dimensional
8.
Prog Orthod ; 25(1): 17, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735912

ABSTRACT

BACKGROUND: Low-intensity electrical stimulation (LIES) is considered a relatively recent technology that has received little attention in orthodontics as a method of acceleration. This study aimed to evaluate patient-reported outcome measures when LIES is used to accelerate the en-masse retraction of the upper anterior teeth. MATERIALS AND METHODS: The sample consisted of 40 patients (8 males, 32 females; mean age 21.1 ± 2.3 years), with Class II division I malocclusion who required extraction of the first premolars to retract upper anterior teeth. They were randomly assigned to the LIES group (n = 20) and the conventional en-masse retraction group (CER; n = 20). Patient responses regarding pain, discomfort, burning sensation, swelling, chewing difficulty, speech difficulty, and painkillers' consumption were recorded at these nine assessment times: 24 h (T1), 3 days (T2), and 7 days (T3) after force application, then in the second month after 24 h (T4), 3 days (T5), and 7 days (T6) of force re-activation, and finally after 24 h (T7), 3 days (T8), and 7 days (T9) of force re-activation in the third month. RESULTS: The mean values of pain perception were smaller in the LIES group than those in the CER group at all assessment times with no statistically significant differences between the two groups except during the second and third months (T5, T6, T8, and T9; P < 0.005). However, discomfort mean values were greater in the LIES group with significant differences compared to CER group during the first week of the follow-up only (T1, T2, and T3; P < 0.005). Burning sensation levels were very mild in the LIES group, with significant differences between the two groups at T1 and T2 only (P < 0.001). Speech difficulty was significantly greater in the LIES group compared to CER group at all studied times (P < 0.001). High levels of satisfaction and acceptance were reported in both groups, without any significant difference. CONCLUSION: Both the LIES-based acceleration of en-masse retraction of upper anterior teeth and the conventional retraction were accompanied by mild to moderate pain, discomfort, and chewing difficulty on the first day of retraction. These sensations gradually decreased and almost disappeared over a week after force application or re-activation. TRIAL REGISTRATION: ClinicalTrials.gov, ClinicalTrials.gov, NCT05920525. Registered 17 June 2023 - retrospectively registered, http://clinicaltrials.gov/study/NCT05920525?term=NCT05920525&rank=1 .


Subject(s)
Patient Reported Outcome Measures , Tooth Movement Techniques , Humans , Female , Male , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Young Adult , Malocclusion, Angle Class II/therapy , Tooth Extraction , Bicuspid , Electric Stimulation/methods , Mastication/physiology , Incisor , Maxilla , Pain Measurement
9.
Eur J Orthod ; 46(3)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38733349

ABSTRACT

OBJECTIVES: The biomechanics in achieving molar distalization may differ between fixed appliances and clear aligners in the control of tooth movement. The objective of this study was to compare the treatment effects between clear aligners (CA) and fixed appliances (FA) in patients treated with miniscrew-assisted molar distalization. METHODS: The sample consisted of 46 subjects with mild-to-moderate crowding. A total of 22 patients treated with clear aligners (age, 25.66 ±â€…6.11 years old) and 24 patients treated with fixed appliances (age, 24.04 ±â€…4.95 years old) for miniscrew-assisted molar distalization were included in this study. The dental and skeletal changes were evaluated by the pre- and post-treatment lateral cephalograms. RESULTS: Significant changes were found with the vertical variables SN-OP angle (2.24 ±â€…3.22°, P < .05) and SN-MP angle (0.73 ±â€…1.15°, P < .05) for the FA group when compared with the CA group (SN-OP angle 0.41 ±â€…2.26° and SN-MP angle -0.21 ±â€…1.38°, P > .05). Both treatment groups achieved a 2-3 mm. molar distalization with significant intrusion of the upper molars. The CA group showed significantly less distal tipping of molars (U6^PP angle -2.29 ±â€…3.29° and L6^MP angle -2.92 ±â€…2.49°, P < .05) compared to the FA group (-5.24 ±â€…4.28° and -5.53 ±â€…5.03°, P < .05). In addition, significant retraction and lingual inclination of the upper and lower incisors were found in both groups. LIMITATIONS: The changes of tooth position were evaluated by 2D lateral cephalograms, not 3D measurements. CONCLUSIONS: Compared to fixed appliances, clear aligners seemed to have better control of vertical dimension and distal tipping of molars in patients treated with miniscrew-assisted molar distalization.


Subject(s)
Bone Screws , Cephalometry , Molar , Orthodontic Anchorage Procedures , Orthodontic Appliances, Fixed , Tooth Movement Techniques , Humans , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Male , Female , Adult , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Young Adult , Orthodontic Appliance Design , Malocclusion/therapy , Treatment Outcome , Maxilla , Mandible , Orthodontic Appliances, Removable , Incisor , Vertical Dimension
10.
Head Face Med ; 20(1): 31, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745246

ABSTRACT

BACKGROUND: In this study, we sought to quantify the influence of vertical control assisted by a temporary anchorage device (TAD) on orthodontic treatment efficacy for skeletal class II patients with a hyperdivergent facial type and probe into the critical factors of profile improvement. METHODS: A total of 36 adult patients with skeletal class II and a hyperdivergent facial type were included in this retrospective case-control study. To exclude the effect of sagittal anchorage reinforcement, the patients were divided into two groups: a maxillary maximum anchorage (MMA) group (N = 17), in which TADs were only used to help with anterior tooth retraction, and the MMA with vertical control (MMA + VC) group (N = 19), for which TADs were also used to intrude the maxillary molars and incisors. The treatment outcome was evaluated using dental, skeletal, and soft-tissue-related parameters via a cephalometric analysis and cast superimposition. RESULTS: A significant decrease in ANB (P < 0.05 for both groups), the retraction and uprighting of the maxillary and mandibular incisors, and the retraction of protruded upper and lower lips were observed in both groups. Moreover, a significant intrusion of the maxillary molars was observed via the cephalometric analysis (- 1.56 ± 1.52 mm, P < 0.05) and cast superimposition (- 2.25 ± 1.03 mm, P < 0.05) of the MMA + VC group but not the MMA group, which resulted in a remarkable decrease in the mandibular plane angle (- 1.82 ± 1.38°, P < 0.05). The Z angle (15.25 ± 5.30°, P < 0.05) and Chin thickness (- 0.97 ± 0.45°, P < 0.05) also improved dramatically in the MMA + VC group, indicating a better profile and a relaxed mentalis. Multivariate regression showed that the improvement in the soft tissue was closely related to the counterclockwise rotation of the mandible plane (P < 0.05). CONCLUSIONS: TAD-assisted vertical control can achieve intrusion of approximately 2 mm for the upper first molars and induce mandibular counterclockwise rotation of approximately 1.8°. Moreover, it is especially important for patients without sufficient retraction of the upper incisors or a satisfactory chin shape.


Subject(s)
Cephalometry , Malocclusion, Angle Class II , Humans , Malocclusion, Angle Class II/therapy , Malocclusion, Angle Class II/diagnostic imaging , Female , Male , Retrospective Studies , Adult , Case-Control Studies , Young Adult , Treatment Outcome , Orthodontic Anchorage Procedures/methods , Orthodontic Anchorage Procedures/instrumentation , Orthodontics, Corrective/methods , Tooth Movement Techniques/methods , Vertical Dimension , Adolescent
11.
Clin Oral Investig ; 28(6): 333, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38780877

ABSTRACT

OBJECTIVE: The objective of this review is to assess the effect of total maxillary arch distalization (TMAD) treatment on the dental, skeletal, soft tissues, and airways during non-extraction camouflage treatment of class II division 1 patients. METHODS: We performed a systematic review of the published data in four electronic databases up to April 2023. We considered studies for inclusion if they were examining the effects of TMAD during treatment of class II division 1 malocclusion in the permanent dentition. Study selection, data extraction, risk of bias assessment, and assessment of the strength of the evidence using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool were performed in duplicate. RESULTS: Out of the 27 articles that met the initial eligibility criteria, 19 studies were finally selected. Fair to relatively good quality evidence was identified after the risk of bias assessment of the included studies. Out of the 19 selected studies, 5 studies used inter-radicular TADs, 10 studies used modified C- palatal plate (MCPP), 3 studies used infra zygomatic crest (IZC) TADs, 1 study compared buccal TADs versus MCPP, and 1 study compared between cervical headgear and MCPP. The maximum amount of maxillary arch distalization using buccal TADs, MCPP, IZC TADs, and headgear was 4.2mm, 5.4mm, 5mm, and 2.5mm respectively. Different results regarding the amount of dental, skeletal, and soft tissue changes were observed. CONCLUSIONS: The current low to very low certainty level of evidence suggests that TMAD is effective in camouflaging class II division 1 malocclusion. Future well-conducted and clearly reported randomized controlled trials that include a control group are needed to make robust recommendations regarding the effect of TMAD with different appliances on dental, skeletal, and soft tissue structures. CLINICAL RELEVANCE: TMAD should be given priority with caution in class II patients who refuse the extraction of premolars. TMAD may be considered an adjunctive approach to solve cases associated with high anchorage need or anchorage loss.


Subject(s)
Malocclusion, Angle Class II , Humans , Malocclusion, Angle Class II/therapy , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Maxilla
12.
Eur J Orthod ; 46(3)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38764143

ABSTRACT

BACKGROUND: Sex hormones secreted during the menstrual cycle and the application of orthodontic forces to teeth can affect the metabolism of periodontal ligaments. This study aimed to determine whether there are any differences in orthodontic tooth displacement during the menstrual cycle and when using hormonal contraceptives and whether the amount of female sex hormones influences the efficiency of tooth displacement. METHODS: A total of 120 women aged between 20 and 30 years with Angle Class II requiring transpalatal arch (TPA) to derotate teeth 16 and 26 were included in this study. The participants were divided into two groups: group A, which included women with regular menstruation, and control group B, which included women taking monophasic combined oral contraceptives. Group A was divided into subgroups according to the moment of TPA activation: menstruation (A1), ovulation phase (A2), and luteal phase (A3) (examination I). On intraoral scans, measurement points were marked on the proximal mesial cusps of teeth 16 and 26, and the intermolar distance (M1) was determined. The change in the position of the measurement points 6 weeks after activation (examination II) made it possible to determine the derotating extent of teeth 16 (O16) and 26 (O26) and the widening of the intermolar distance (M2-M1). In examinations I and II, tooth mobility in the alveoli was assessed using Periotest based on the periotest values (PTV) PTV1 and PTV2, respectively. RESULTS: A significant difference in all parameters was observed among groups A1, A2, and A3 (P < 0.001). Group A3 showed the highest values of parameters O16, O26, and M2-M1, and group A2 showed the lowest values, which did not differ from the control group (P = 0.64). PTV2 and PTV1 were the highest in group A3 and the lowest in groups A1 and B. Intergroup differences were statistically significant (P < 0.001). CONCLUSIONS: With the quantification of changes in tooth mobility in the alveoli during the menstrual cycle in women undergoing orthodontic treatment, it was possible to determine that female sex hormones affect the effectiveness of orthodontic treatment, and the optimal moment for TPA activation is the luteal phase of the menstrual cycle.


Subject(s)
Luteal Phase , Maxilla , Menstrual Cycle , Tooth Movement Techniques , Humans , Female , Tooth Movement Techniques/methods , Prospective Studies , Adult , Young Adult , Luteal Phase/physiology , Menstrual Cycle/physiology , Malocclusion, Angle Class II , Menstruation/physiology , Ovulation/physiology , Estradiol , Gonadal Steroid Hormones , Progesterone
13.
Sci Rep ; 14(1): 11348, 2024 05 18.
Article in English | MEDLINE | ID: mdl-38762583

ABSTRACT

Clear aligners are employed daily for the treatment of several malocclusions. Previous clinical studies indicated low accuracy for the correction of tooth rotations. The aim of this study was to evaluate the predictability of tooth rotations with clear aligners. The sample comprised 390 teeth (190 mandibular; 200 maxillary), measured from the virtual models of 45 participants (21 men, 24 women; mean age: 29.2 ± 6.6 years old). For each patient, pre-treatment (T0) digital dental models (STL files), virtual plan (T1) and post-treatment digital dental models (T2) of both the mandibular and maxillary arches were imported onto Geomagic Control X, a 3D metrology software which allows angular measurements. Rotations were calculated by defining reproducible vectors for all teeth in each STL file and superimposing both T0 with T1 to determine the prescribed rotation, and T0 with T2 to determine the achieved rotation. Prescribed and achieved rotations were compared to assess movement's accuracy. The Wilcoxon signed-rank test and paired t-test were used to assess differences between the prescribed and achieved movements (P < 0.05). The overall predictability of rotational movement was 78.6% for the mandibular arch and 75.0% for the maxillary arch. Second molar accuracy was the lowest in both arches. Clear aligners were not able to achieve 100% of the planned movements.


Subject(s)
Malocclusion , Humans , Female , Male , Adult , Malocclusion/therapy , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Maxilla , Rotation , Mandible , Young Adult , Models, Dental
14.
Prog Orthod ; 25(1): 19, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38797777

ABSTRACT

BACKGROUND: Skeletal anterior open bite (SAOB) represents one of the most complex and challenging malocclusions in orthodontics. Orthodontic treatment supported by miniplates enable to reduce the need for orthognathic surgery. Transverse dimension may be affected by intrusion biomechanics. This study aims to assess transverse bone alterations in patients with SAOB who underwent orthodontic treatment with absolute anchorage using four miniplates. METHODS: A total of 32 patients of both sexes, with an average age of 33.8 years, diagnosed with SAOB and treated orthodontically with four miniplates (one in each hemiarch), were selected for this study. Tomographic examinations were performed before (T1) and after (T2) orthodontic treatment. Linear measurements (width of the maxillary base, maxillary alveolar, maxillary root, maxillary dental cusp, mandibular alveolar) and angular measurements (maxillary intermolar angle) were assessed in these images. The Shapiro-Wilks normality tests were applied to verify data distribution, and the paired t-test was used to compare the initial and final measures obtained. RESULTS: Among the evaluated parameters, the maxillary alveolar width, maxillary dental cusp width, mandibular alveolar cusp width, and intermolar angle showed statistically significant differences between T1 and T2 (p < 0.05). However, maxillary base and maxillary root widths showed no significant difference (p > 0.05). CONCLUSIONS: Intrusion and distalization with miniplates in SAOB therapy may lead to significant expansive changes, due to molars cusps width and buccal inclination increase restricted at the alveolar level.


Subject(s)
Bone Plates , Mandible , Open Bite , Orthodontic Anchorage Procedures , Humans , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Male , Female , Open Bite/therapy , Open Bite/diagnostic imaging , Adult , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Cephalometry , Alveolar Process/diagnostic imaging , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Tomography, X-Ray Computed/methods , Young Adult , Orthodontic Appliance Design
15.
Clin Oral Investig ; 28(6): 338, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38797781

ABSTRACT

OBJECTIVES: To clinically compare the effects of broader archwires to standard archwires, using conventional brackets in both cases, on the transverse and incisor changes in maxillary and mandibular arches during leveling and alignment. MATERIALS AND METHODS: Fifty-two patients presenting with crowding were allocated into two groups; one group received the broad Damon archwires while the other received standard 3M OrthoForm III Ovoid archwires. All participants were treated with conventional brackets using similar archwire sequences (0.014, 0.018, 0.016 × 0.022/0.016 × 0.025, 0.019 × 0.025 NiTi/CuNiTi archwires). Digital casts were obtained from alginate impressions before treatment (T0) and six weeks after inserting 0.019 × 0.025 NiTi archwires (T1). Pretreatment (T0) and post-alignment (T1) lateral cephalograms were obtained for each patient. The primary outcomes were the changes in the transverse arch dimensions and incisor inclination. The secondary outcomes were the horizontal and vertical linear changes in incisor position. RESULTS: Complete data were collected for 47 patients. There was a significant increase in arch width during treatment within each group, except for upper inter-molar width in 3M group (P = 0.071). Damon wire induced a statistically significant increase in maxillary inter-second premolar width (P = 0.042), and mandibular inter-first premolar (P = 0.043), inter-second premolar (P = 0.008) and inter-molar widths (P = 0.033) compared to 3M group. The increase in incisor proclination and the linear change in incisor position were significant within each group, with less mandibular incisor proclination (P = 0.004) and horizontal advancement (P = 0.038) in the Damon group. CONCLUSIONS: Damon archwires created a comparatively greater increase in the maxillary inter-second premolar width and the mandibular inter-first premolar, inter-second premolar, and inter-molar widths, and less proclination and horizontal advancement in mandibular incisors. The study provides invaluable evidence that using broad archwires with self-ligating brackets is the reason behind any greater expansion observed in this system rather than the unique mechanical and biological features exerted by the self-ligating system. CLINICAL RELEVANCE: Our results suggest that Damon archwire might be a better alternative compared to the narrower standard archwires that are usually used with conventional brackets, especially in the mandibular arch, in cases where mild to moderate crowding is planned to be resolved with a non-extraction approach. However, as arch expansion in the absence of posterior crossbites raises the question of long-term stability, the reported advantage of the use of wide wires should be interpreted with caution and should be considered in the retention phase, bearing in mind that achieving a good post-treatment occlusion is important for enhancing post-treatment stability.


Subject(s)
Cephalometry , Incisor , Malocclusion , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Humans , Female , Male , Malocclusion/therapy , Adolescent , Nickel/chemistry , Dental Arch , Titanium/chemistry , Treatment Outcome , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Copper
18.
Dental Press J Orthod ; 29(2): e2423237, 2024.
Article in English | MEDLINE | ID: mdl-38775600

ABSTRACT

OBJECTIVE: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. METHODS: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. RESULTS: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. CONCLUSION: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


Subject(s)
Tooth Movement Techniques , Humans , Tooth Movement Techniques/instrumentation , Retrospective Studies , Adult , Rotation , Female , Male , Orthodontic Appliance Design , Incisor , Models, Dental , Orthodontic Appliances, Removable , Dental Arch
19.
Int J Mol Sci ; 25(10)2024 May 10.
Article in English | MEDLINE | ID: mdl-38791262

ABSTRACT

Orthodontic space closure following tooth extraction is often hindered by alveolar bone deficiency. This study investigates the therapeutic use of nuclear factor-kappa B (NF-κB) decoy oligodeoxynucleotides loaded with polylactic-co-glycolic acid nanospheres (PLGA-NfDs) to mitigate alveolar bone loss during orthodontic tooth movement (OTM) following the bilateral extraction of maxillary first molars in a controlled experiment involving forty rats of OTM model with ethics approved. The decreased tendency of the OTM distance and inclination angle with increased bone volume and improved trabecular bone structure indicated minimized alveolar bone destruction. Reverse transcription-quantitative polymerase chain reaction and histomorphometric analysis demonstrated the suppression of inflammation and bone resorption by downregulating the expression of tartrate-resistant acid phosphatase, tumor necrosis factor-α, interleukin-1ß, cathepsin K, NF-κB p65, and receptor activator of NF-κB ligand while provoking periodontal regeneration by upregulating the expression of alkaline phosphatase, transforming growth factor-ß1, osteopontin, and fibroblast growth factor-2. Importantly, relative gene expression over the maxillary second molar compression side in proximity to the alveolus highlighted the pharmacological effect of intra-socket PLGA-NfD administration, as evidenced by elevated osteocalcin expression, indicative of enhanced osteocytogenesis. These findings emphasize that locally administered PLGA-NfD serves as an effective inflammatory suppressor and yields periodontal regenerative responses following tooth extraction.


Subject(s)
Nanospheres , Oligodeoxyribonucleotides , Polylactic Acid-Polyglycolic Acid Copolymer , Tooth Movement Techniques , Tooth Socket , Animals , Polylactic Acid-Polyglycolic Acid Copolymer/chemistry , Rats , Nanospheres/chemistry , Tooth Movement Techniques/methods , Oligodeoxyribonucleotides/pharmacology , Oligodeoxyribonucleotides/administration & dosage , Tooth Socket/drug effects , Tooth Socket/pathology , Male , NF-kappa B/metabolism , Wound Healing/drug effects , Alveolar Bone Loss/therapy , Alveolar Bone Loss/pathology , Alveolar Bone Loss/drug therapy , Alveolar Bone Loss/metabolism , Tooth Extraction
20.
Eur J Orthod ; 46(3)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38819172

ABSTRACT

BACKGROUND: The minimal important difference (MID) is defined as the smallest difference that the patient perceives as important. Furthermore, the smallest worthwhile effect (SWE) is the important change measured with the benefit-harm trade-off method. The aim of this study was to evaluate the MID in orthodontic treatment duration to inform the decision regarding seeking procedures to accelerate orthodontic tooth movement and reduce treatment duration. METHODS: We constructed a survey eliciting views of the MID from adult participants from four countries undergoing orthodontic treatment. Ten questions addressed reduction in the treatment duration for both durations 12 and 24 months, and four questions were related to the reduction in treatment duration that the patients would require to undergo surgical or non-surgical adjunctive procedures. We applied a univariable random effects logistic regression model to examine the association between the participants' characteristics and the MID. Then, we fitted a multivariable logistic random effects regression including significant predictors. RESULTS: Four hundred and fifty adults, with a median age of 21 (interquartile range: 19-24), undergoing orthodontic treatment participated in the survey. Of the respondents, 60% considered 15 days as a trivial reduction from 12 months duration of therapy and 70% considered 15 days a trivial reduction from 24 months. Of the respondents, 48% considered the period of 2 months a moderate reduction from 12 months, and 60% considered 2 months a moderate reduction from 24 months. From these results, we inferred that patients considered reductions of approximately 1 month as the MID in the treatment duration for both 12 and 24 months. However, SWE was considerably more than the MID for most of the participants to decide undergoing surgical adjunctive procedures to reduce the time of therapy. The participants required smaller SWE to undergo non-surgical procedures compared to surgical procedures. CONCLUSION: The MID in the treatment duration is one month for both treatment durations 12 and 24 months. Patients require a greater SWE than the MID to undergo adjunctive procedures to shorten the duration, particularly for surgical procedures.


Subject(s)
Orthodontics, Corrective , Humans , Female , Male , Time Factors , Young Adult , Orthodontics, Corrective/methods , Surveys and Questionnaires , Adult , Tooth Movement Techniques/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...