Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 297
Filter
1.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639328

ABSTRACT

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Subject(s)
Aortic Valve Stenosis , Patient Discharge , Patient Readmission , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/trends , Patient Readmission/statistics & numerical data , Patient Readmission/trends , Male , Female , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aged , Patient Discharge/trends , Registries , Length of Stay/statistics & numerical data , Length of Stay/trends , Time Factors , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Treatment Outcome , United States/epidemiology , Risk Factors , Aortic Valve/surgery , Retrospective Studies , Prosthesis Design , Risk Assessment
2.
Arch Cardiovasc Dis ; 117(5): 321-331, 2024 May.
Article in English | MEDLINE | ID: mdl-38670869

ABSTRACT

BACKGROUND: Transcatheter (TAVR) has supplanted surgical (SAVR) aortic valve replacement (AVR). AIM: To evaluate whether adoption of this technology has varied according to centre volume at the nationwide level. METHODS: From an administrative hospital-discharge database, we collected data on all AVRs performed in France between 2007 and 2019. Centres were divided into terciles based on the annual number of SAVRs performed in 2007-2009 ("before TAVR era"). RESULTS: A total of 192,773 AVRs (134,662 SAVRs and 58,111 TAVRs) were performed in 47 centres. The annual number of AVRs and TAVRs increased significantly and linearly in low-volume (<152 SAVRs/year; median 106, interquartile range [IQR] 75-129), middle-volume (152-219 SAVRs/year; median 197, IQR 172-212) and high-volume (>219 SAVRs/year; median 303, IQR 268-513) terciles, but to a greater degree in the latter (+14, +16 and +24 AVRs/centre/year and +16, +19 and +31 TAVRs/centre/year, respectively; PANCOVA<0.001). Charlson Comorbidity Index and in-hospital death rates declined from 2010 to 2019 in all terciles (all Ptrend<0.05). In 2017-2019, after adjusting for age, sex and Charlson Comorbidity Index, there was a trend toward lower death rates in the high-volume tercile (P=0.06) for SAVR, whereas death rates were similar for TAVR irrespective of tercile (P=0.27). Similar results were obtained when terciles were defined based on number of interventions performed in the last instead of the first 3years. Importantly, even centres in the lowest-volume tercile performed a relatively high number of interventions (150 TAVRs/year/centre). CONCLUSIONS: In a centralized public healthcare system, the total number of AVRs increased linearly between 2007 and 2019, mostly due to an increase in TAVR, irrespective of centre volume. Progressive declines in patient risk profiles and death rates were observed in all terciles; in 2017-2019 death rates were similar in all terciles, although lower in high-volume centres for SAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Databases, Factual , Heart Valve Prosthesis Implantation , Hospitals, High-Volume , Hospitals, Low-Volume , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , France/epidemiology , Hospitals, High-Volume/trends , Transcatheter Aortic Valve Replacement/trends , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Female , Hospitals, Low-Volume/trends , Male , Aged , Treatment Outcome , Time Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Risk Factors , Aged, 80 and over , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis Implantation/instrumentation , Practice Patterns, Physicians'/trends , Risk Assessment , Retrospective Studies , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Diffusion of Innovation
3.
Int J Cardiol ; 406: 131996, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38555056

ABSTRACT

OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.


Subject(s)
Aortic Valve Stenosis , Humans , Female , Male , Europe/epidemiology , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Aged, 80 and over , Sex Factors , Transcatheter Aortic Valve Replacement/trends , Transcatheter Aortic Valve Replacement/statistics & numerical data , Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis Implantation/statistics & numerical data , Aortic Valve/surgery , Middle Aged
4.
JACC Cardiovasc Interv ; 17(10): 1267-1276, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38530682

ABSTRACT

BACKGROUND: Prior studies have reported decreased use of an invasive approach for acute myocardial infarction (AMI) in patients undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVES: The aim of this study was to determine whether prior TAVR affects the use of subsequent coronary revascularization and outcomes of AMI in a contemporary national data set. METHODS: Consecutive TAVR patients from 2016 to 2022 were identified from the U.S. Vizient Clinical Data Base who were hospitalized after the index TAVR hospitalization with ST-segment elevation myocardial infarction (STEMI) or non-ST-segment elevation myocardial infarction (NSTEMI). Patients with STEMI or NSTEMI with or without prior TAVR from the same time period were compared for the use of coronary angiography, revascularization, and in-hospital outcomes. Propensity score matching was used to account for imbalances in patient characteristics. RESULTS: Among 206,229 patients who underwent TAVR, the incidence of STEMI was 25 events per 100,000 person-years of follow-up, and that of NSTEMI was 229 events per 100,000 person-years. After propensity matching, the use of coronary revascularization was similar in the prior TAVR and no TAVR cohorts in both the STEMI (65.3% vs 63.9%; P = 0.81) and NSTEMI (41.4% vs 41.7%; P = 0.88) subgroups. Compared with patients without prior TAVR, in-hospital mortality was higher in the prior TAVR cohort in patients with STEMI (27.1% vs 16.7%; P = 0.03) and lower in those with NSTEMI (5.8% vs 8.2%; P = 0.02). CONCLUSIONS: In this large, national retrospective study, AMI events after TAVR were infrequent. There were no differences in the use of coronary revascularization for STEMI or NSTEMI in TAVR patients compared with the non-TAVR population. In-hospital mortality for STEMI is higher in TAVR patients compared with those without prior TAVR.


Subject(s)
Aortic Valve Stenosis , Databases, Factual , Hospital Mortality , Non-ST Elevated Myocardial Infarction , ST Elevation Myocardial Infarction , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Male , Female , United States/epidemiology , Treatment Outcome , Non-ST Elevated Myocardial Infarction/mortality , Non-ST Elevated Myocardial Infarction/therapy , Non-ST Elevated Myocardial Infarction/diagnostic imaging , Aged , Risk Factors , Time Factors , Aged, 80 and over , Risk Assessment , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/diagnostic imaging , Incidence , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Retrospective Studies , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Percutaneous Coronary Intervention/trends
5.
Eur Heart J ; 45(21): 1877-1886, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38190428

ABSTRACT

BACKGROUND AND AIMS: Severe aortic stenosis (AS) is the guideline-based indication for aortic valve replacement (AVR), which has markedly increased with transcatheter approaches, suggesting possible increasing AS incidence. However, reported secular trends of AS incidence remain contradictory and lack quantitative Doppler echocardiographic ascertainment. METHODS: All adults residents in Olmsted County (MN, USA) diagnosed over 20 years (1997-2016) with incident severe AS (first diagnosis) based on quantitatively defined measures (aortic valve area ≤ 1 cm2, aortic valve area index ≤ 0.6 cm2/m2, mean gradient ≥ 40 mmHg, peak velocity ≥ 4 m/s, Doppler velocity index ≤ 0.25) were counted to define trends in incidence, presentation, treatment, and outcome. RESULTS: Incident severe AS was diagnosed in 1069 community residents. The incidence rate was 52.5 [49.4-55.8] per 100 000 patient-year, slightly higher in males vs. females and was almost unchanged after age and sex adjustment for the US population 53.8 [50.6-57.0] per 100 000 residents/year. Over 20 years, severe AS incidence remained stable (P = .2) but absolute burden of incident cases markedly increased (P = .0004) due to population growth. Incidence trend differed by sex, stable in men (incidence rate ratio 0.99, P = .7) but declining in women (incidence rate ratio 0.93, P = .02). Over the study, AS clinical characteristics remained remarkably stable and AVR performance grew and was more prompt (from 1.3 [0.1-3.3] years in 1997-2000 to 0.5 [0.2-2.1] years in 2013-16, P = .001) but undertreatment remained prominent (>40%). Early AVR was associated with survival benefit (adjusted hazard ratio 0.55 [0.42-0.71], P < .0001). Despite these improvements, overall mortality (3-month 8% and 3-year 36%), was swift, considerable and unabated (all P ≥ .4) throughout the study. CONCLUSIONS: Over 20 years, the population incidence of severe AS remained stable with increased absolute case burden related to population growth. Despite stable severe AS presentation, AVR performance grew notably, but while declining, undertreatment remained substantial and disease lethality did not yet decline. These population-based findings have important implications for improving AS management pathways.


Subject(s)
Aortic Valve Stenosis , Humans , Aortic Valve Stenosis/epidemiology , Male , Female , Incidence , Aged , Middle Aged , Minnesota/epidemiology , Aged, 80 and over , Transcatheter Aortic Valve Replacement/trends , Transcatheter Aortic Valve Replacement/statistics & numerical data , Echocardiography, Doppler , Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis Implantation/statistics & numerical data , Severity of Illness Index , Treatment Outcome
6.
J Am Coll Cardiol ; 78(22): 2161-2172, 2021 11 30.
Article in English | MEDLINE | ID: mdl-34823659

ABSTRACT

BACKGROUND: Recent trends, including survival beyond 30 days, in aortic valve replacement (AVR) following the expansion of indications for transcatheter aortic valve replacement (TAVR) are not well-understood. OBJECTIVES: The authors sought to characterize the trends in characteristics and outcomes of patients undergoing AVR. METHODS: The authors analyzed Medicare beneficiaries who underwent TAVR and SAVR in 2012 to 2019. They evaluated case volume, demographics, comorbidities, 1-year mortality, and discharge disposition. Cox proportional hazard models were used to assess the annual change in outcomes. RESULTS: Per 100,000 beneficiary-years, AVR increased from 107 to 156, TAVR increased from 19 to 101, whereas SAVR declined from 88 to 54. The median [interquartile range] age remained similar from 77 [71-83] years to 78 [72-84] years for overall AVR, decreased from 84 [79-88] years to 81 [75-86] years for TAVR, and decreased from 76 [71-81] years to 72 [68-77] years for SAVR. For all AVR patients, the prevalence of comorbidities remained relatively stable. The 1-year mortality for all AVR decreased from 11.9% to 9.4%. Annual change in the adjusted odds of 1-year mortality was 0.93 (95% CI: 0.92-0.94) for TAVR and 0.98 (95% CI: 0.97-0.99) for SAVR, and 0.94 (95% CI: 0.93-0.95) for all AVR. Patients discharged to home after AVR increased from 24.2% to 54.7%, primarily driven by increasing home discharge after TAVR. CONCLUSIONS: The advent of TAVR has led to about a 60% increase in overall AVR in older adults. Improving outcomes in AVR as a whole following the advent of TAVR with increased access is a reassuring trend.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Medicare/statistics & numerical data , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Female , Follow-Up Studies , Hospital Mortality/trends , Humans , Male , Retrospective Studies , Risk Factors , Survival Rate/trends , Time Factors , United States/epidemiology
7.
J Am Heart Assoc ; 10(16): e020490, 2021 08 17.
Article in English | MEDLINE | ID: mdl-34387116

ABSTRACT

Background Patients with symptomatic severe aortic stenosis (ssAS) have a high mortality risk and compromised quality of life. Surgical/transcatheter aortic valve replacement (AVR) is a Class I recommendation, but it is unclear if this recommendation is uniformly applied. We determined the impact of managing cardiologists on the likelihood of ssAS treatment. Methods and Results Using natural language processing of Optum electronic health records, we identified 26 438 patients with newly diagnosed ssAS (2011-2016). Multilevel, multivariable Fine-Gray competing risk models clustered by cardiologists were used to determine the impact of cardiologists on the likelihood of 1-year AVR treatment. Within 1 year of diagnosis, 35.6% of patients with ssAS received an AVR; however, rates varied widely among managing cardiologists (0%, lowest quartile; 100%, highest quartile [median, 29.6%; 25th-75th percentiles, 13.3%-47.0%]). The odds of receiving AVR varied >2-fold depending on the cardiologist (median odds ratio for AVR, 2.25; 95% CI, 2.14-2.36). Compared with patients with ssAS of cardiologists with the highest treatment rates, those treated by cardiologists with the lowest AVR rates experienced significantly higher 1-year mortality (lowest quartile, adjusted hazard ratio, 1.22, 95% CI, 1.13-1.33). Conclusions Overall AVR rates for ssAS were low, highlighting a potential challenge for ssAS management in the United States. Cardiologist AVR use varied substantially; patients treated by cardiologists with lower AVR rates had higher mortality rates than those treated by cardiologists with higher AVR rates.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiologists/trends , Heart Valve Prosthesis Implantation/trends , Outcome and Process Assessment, Health Care/trends , Practice Patterns, Physicians'/trends , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Clinical Decision-Making , Electronic Health Records , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Natural Language Processing , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
8.
J Am Heart Assoc ; 10(14): e017487, 2021 07 20.
Article in English | MEDLINE | ID: mdl-34261361

ABSTRACT

Background Racial and ethnic inequities exist in surgical aortic valve replacement for aortic stenosis (AS), and early studies have suggested similar inequities in transcatheter aortic valve replacement. Methods and Results We performed a retrospective analysis of the Maryland Health Services Cost Review Commission inpatient data set from 2016 to 2018. Black patients had half the incidence of any inpatient AS diagnosis compared with White patients (incidence rate ratio [IRR], 0.50; 95% CI, 0.48-0.52; P<0.001) and Hispanic patients had one fourth the incidence compared with White patients (IRR, 0.25; 95% CI, 0.22-0.29; P<0.001). Conversely, the incidence of any inpatient mitral regurgitation diagnosis did not differ between White and Black patients (IRR, 1.00; 95% CI, 0.97-1.03; P=0.97) but was significantly lower in Hispanic compared with White patients (IRR, 0.36; 95% CI, 0.33-0.40; P<0.001). After multivariable adjustment, Black race was associated with a lower incidence of surgical aortic valve replacement (IRR, 0.67; 95% CI, 0.55-0.82 P<0.001 relative to White race) and transcatheter aortic valve replacement (IRR, 0.77; 95% CI, 0.65-0.90; P=0.002) among those with any inpatient diagnosis of AS. Hispanic patients had a similar rate of surgical aortic valve replacement and transcatheter aortic valve replacement compared with White patients. Conclusions Hospitalization with any diagnosis of AS is less common in Black and Hispanic patients than in White patients. In hospitalized patients with AS, Black race is associated with a lower incidence of both surgical aortic valve replacement and transcatheter aortic valve replacement compared with White patients, whereas Hispanic patients have a similar incidence of both. The reasons for these inequities are likely multifactorial.


Subject(s)
Aortic Valve Stenosis/ethnology , Aortic Valve Stenosis/surgery , Black or African American/statistics & numerical data , Hispanic or Latino/statistics & numerical data , Transcatheter Aortic Valve Replacement/statistics & numerical data , White People/statistics & numerical data , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Cause of Death , Female , Health Equity , Hospitalization , Humans , Incidence , Male , Maryland/epidemiology , Middle Aged , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends
9.
J Am Heart Assoc ; 10(13): e020741, 2021 07 06.
Article in English | MEDLINE | ID: mdl-34155897

ABSTRACT

Background The multidisciplinary Heart Team (HT) is recommended for management decisions for transcatheter aortic valve replacement (TAVR) candidates, and during TAVR procedures. Empiric evidence to support these recommendations is limited. We aimed to explore temporal trends, drivers, and outcomes associated with HT utilization. Methods and Results TAVR candidates were identified in Ontario, Canada, from April 1, 2012 to March 31, 2019. The HT was defined as having a billing code for both a cardiologist and cardiac surgeon during the referral period. The procedural team was defined as a billing code during the TAVR procedure. Hierarchical logistical models were used to determine the drivers of HT. Median odds ratios were calculated to quantify the degree of variation among hospitals. Of 10 412 patients referred for TAVR consideration, 5489 (52.7%) patients underwent a HT during the referral period, with substantial range between hospitals (median odds ratio of 1.78). Utilization of a HT for TAVR referrals declined from 69.9% to 41.1% over the years of the study. Patient characteristics such as older age, frailty and dementia, and hospital characteristics including TAVR program size, were found associated with lower HT utilization. In TAVR procedures, the procedural team included both cardiologists and cardiac surgeons in 94.9% of cases, with minimal variation over time or between hospitals. Conclusions There has been substantial decline in HT utilization for TAVR candidates over time. In addition, maturity of TAVR programs was associated with lower HT utilization.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiologists/trends , Patient Care Team/trends , Practice Patterns, Physicians'/trends , Surgeons/trends , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Humans , Male , Ontario , Program Evaluation , Referral and Consultation/trends , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
J Am Heart Assoc ; 10(12): e019588, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34056912

ABSTRACT

Background Transcatheter aortic valve replacement (TAVR) has transformed the management of aortic valve stenosis. However, little national data are available characterizing the geographic and demographic dispersion of this disruptive technology relative to surgical aortic valve replacement (SAVR). Methods and Results In this US claims-based study, we analyzed a 100% sample of fee-for-service Medicare beneficiaries from 2012 to 2017 and examined national rates of TAVR versus SAVR. Procedure rates were compared across years as a function of age, sex, race, and geography for TAVR and SAVR beneficiaries. There was significant growth in TAVR from 15.4 beneficiaries/100 000 enrollees in 2012 to 90.6 in 2017 (P<0.001). SAVR rates declined from 92.8 beneficiaries/100 000 enrollees in 2012 to 63.5 in 2017 (P<0.001). The growth of TAVR varied as a function of age (P<0.0001). While TAVR was the dominant strategy among beneficiaries ≥85 and 75 to 84 years old, SAVR was more common among beneficiaries 65 to 74 years old. TAVR was also used more frequently than SAVR among women (P<0.001). While TAVR increased among all races, it was less commonly used among non-White beneficiaries (P<0.001). Contemporary use of TAVR relative to SAVR varied significantly by geographic location, with a TAVR:SAVR ratio in 2017 of 1.24 in the Midwest and 1.68 in the Northeast (P<0.001). Conclusions In 2017, the number of Medicare beneficiaries receiving TAVR exceeded SAVR for the first time in the United States. There is significant variation, however, in the geographic expansion of TAVR and in patient demographics relative to SAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Healthcare Disparities/trends , Practice Patterns, Physicians'/trends , Surgeons/trends , Transcatheter Aortic Valve Replacement/trends , Age Factors , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/ethnology , Databases, Factual , Female , Humans , Male , Medicare/trends , Race Factors , Sex Factors , Time Factors , United States/epidemiology
12.
J Am Coll Cardiol ; 77(9): 1149-1161, 2021 03 09.
Article in English | MEDLINE | ID: mdl-33663731

ABSTRACT

BACKGROUND: In low surgical risk patients with symptomatic severe aortic stenosis, the PARTNER 3 (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis) trial demonstrated superiority of transcatheter aortic valve replacement (TAVR) versus surgery for the primary endpoint of death, stroke, or re-hospitalization at 1 year. OBJECTIVES: This study determined both clinical and echocardiographic outcomes between 1 and 2 years in the PARTNER 3 trial. METHODS: This study randomly assigned 1,000 patients (1:1) to transfemoral TAVR with the SAPIEN 3 valve versus surgery (mean Society of Thoracic Surgeons score: 1.9%; mean age: 73 years) with clinical and echocardiography follow-up at 30 days and at 1 and 2 years. This study assessed 2-year rates of the primary endpoint and several secondary endpoints (clinical, echocardiography, and quality-of-life measures) in this as-treated analysis. RESULTS: Primary endpoint follow-up at 2 years was available in 96.5% of patients. The 2-year primary endpoint was significantly reduced after TAVR versus surgery (11.5% vs. 17.4%; hazard ratio: 0.63; 95% confidence interval: 0.45 to 0.88; p = 0.007). Differences in death and stroke favoring TAVR at 1 year were not statistically significant at 2 years (death: TAVR 2.4% vs. surgery 3.2%; p = 0.47; stroke: TAVR 2.4% vs. surgery 3.6%; p = 0.28). Valve thrombosis at 2 years was increased after TAVR (2.6%; 13 events) compared with surgery (0.7%; 3 events; p = 0.02). Disease-specific health status continued to be better after TAVR versus surgery through 2 years. Echocardiographic findings, including hemodynamic valve deterioration and bioprosthetic valve failure, were similar for TAVR and surgery at 2 years. CONCLUSIONS: At 2 years, the primary endpoint remained significantly lower with TAVR versus surgery, but initial differences in death and stroke favoring TAVR were diminished and patients who underwent TAVR had increased valve thrombosis. (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [PARTNER 3]; NCT02675114).


Subject(s)
Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Postoperative Complications/mortality , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Postoperative Complications/diagnostic imaging , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
14.
Am Heart J ; 234: 23-30, 2021 04.
Article in English | MEDLINE | ID: mdl-33388288

ABSTRACT

BACKGROUND: Patterns of diffusion of TAVR in the United States (U.S.) and its relation to racial disparities in TAVR utilization remain unknown. METHODS: We identified TAVR hospitals in the continental U.S. from 2012-2017 using Medicare database and mapped them to Hospital Referral Regions (HRR). We calculated driving distance from each residential ZIP code to the nearest TAVR hospital and calculated the proportion of the U.S. population, in general and by race, that lived <100 miles driving distance from the nearest TAVR center. Using a discrete time hazard logistic regression model, we examined the association of hospital and HRR variables with the opening of a TAVR program. RESULTS: The number of TAVR hospitals increased from 230 in 2012 to 540 in 2017. The proportion of the U.S. population living <100 miles from nearest TAVR hospital increased from 89.3% in 2012 to 94.5% in 2017. Geographic access improved for all racial and ethnic subgroups: Whites (84.1%-93.6%), Blacks (90.0%- 97.4%), and Hispanics (84.9%-93.7%). Within a HRR, the odds of opening a new TAVR program were higher among teaching hospitals (OR 1.48, 95% CI 1.16-1.88) and hospital bed size (OR 1.44, 95% CI 1.37-1.52). Market-level factors associated with new TAVR programs were proportion of Black (per 1%, OR 0.78, 95% CI 0.69-0.89) and Hispanic (per 1%, OR 0.82, 95% CI 0.75-0.90) residents, the proportion of hospitals within the HRR that already had a TAVR program (per 10%, OR 1.07, 95% CI 1.03-1.11), P <.01 for all. CONCLUSION: The expansion of TAVR programs in the U.S. has been accompanied by an increase in geographic coverage for all racial subgroups. Further study is needed to determine reasons for TAVR underutilization in Blacks and Hispanics.


Subject(s)
Cardiac Care Facilities , Health Services Accessibility , Transcatheter Aortic Valve Replacement , Humans , Black or African American/statistics & numerical data , Cardiac Care Facilities/statistics & numerical data , Cardiac Care Facilities/trends , Health Services Accessibility/statistics & numerical data , Health Services Accessibility/trends , Hispanic or Latino/statistics & numerical data , Hospital Bed Capacity/statistics & numerical data , Hospitals, Teaching/statistics & numerical data , Hospitals, Teaching/trends , Logistic Models , Medicare/statistics & numerical data , Program Development/statistics & numerical data , Referral and Consultation/statistics & numerical data , Transcatheter Aortic Valve Replacement/statistics & numerical data , Transcatheter Aortic Valve Replacement/trends , United States/ethnology , White
15.
Clin Res Cardiol ; 110(3): 460-465, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33389039

ABSTRACT

AIMS: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are established options to treat aortic valve stenosis. We present the outcome of the complete cohort of all patients undergoing SAVR or TAVI in Germany during the calendar year 2019. METHODS AND RESULTS: Data concerning all isolated aortic valve procedures performed in Germany in 2019 were retrieved from the mandatory nationwide quality control program: 22,973 transvascular (TV)-TAVI procedures, 7905 isolated SAVR (iSAVR), and 1413 transapical (TA)-TAVI. Data was complete in 99.9% (n = 32,156). In-hospital mortality after TV-TAVI (2.3%) was significantly lower when compared with iSAVR (2.8%, p = 0.007) or TA-TAVI (6.3%; p < 0.001). Expected mortality was calculated with a new version of the German Aortic valve score (AKL Score) based on the data of either catheter-based (AKL-CATH) or surgical (AKL-CHIR) aortic valve replacements in Germany in 2018. TV-TAVI and iSAVR both showed lower observed mortality in 2019 than expected based on their respective performance in 2018, yielding an observed/expected (O/E) mortality ratio < 1. This was particularly apparent for patients at low risk. After exclusion of emergency procedures, in-hospital mortality after TV-TAVI (2.1%) and after iSAVR (2.1%) was identical, even though patients undergoing TV-TAVI showed a considerably higher perioperative risk profile. CONCLUSION: After excluding emergency procedures, in-hospital mortality of TV-TAVI and iSAVR in 2019 in Germany was identical. In 2019, TV-TAVI and iSAVR both show lower matched mortality ratios compared with 2018, which suggests technical improvements of both therapies.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Female , Follow-Up Studies , Germany/epidemiology , Humans , Incidence , Male , Retrospective Studies , Time Factors , Treatment Outcome
16.
Am J Cardiol ; 144: 91-99, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33383010

ABSTRACT

The ACC/TVT score is a specific predictive model of in-hospital mortality for patients undergoing transcatheter aortic valve implantation (TAVI). The aim of this study was to test its predictive accuracy in comparison with standard surgical risk models (Logistic Euroscore, Euroscore II, and STS-PROM) in the population of TAVI patients included in the multicenter RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) registry. The study cohort included 3293 patients who underwent TAVI between 2008 and 2019. The 4 risk scores were calculated for all patients. For all scores, the capability to predict 30-day mortality was assessed by means of several analyses testing calibration and discrimination. The ACC/TVT score showed moderate discrimination, with a C-statistics for 30-day mortality of 0.63, not significantly different from the standard surgical risk models. The ACC/TVT score demonstrated, in contrast, better calibration compared with the other scores, as proved by a greater correspondence between estimated probabilities and the actual observations. However, when the ACC/TVT score was tested in the subgroup of patients treated in a more contemporary period (from 2016 on), it revealed a slight tendency to lose discrimination and to overestimate mortality risk. In conclusion, in comparison with the standard surgical risk models, the ACC/TVT score demonstrated better prediction accuracy for estimation of 30-day mortality in terms of calibration. Nevertheless, its predictive reliability remained suboptimal and tended to worsen in patients treated more recently.


Subject(s)
Aortic Valve Stenosis/surgery , Hospital Mortality , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Italy , Male , Mortality , Prognosis , Registries , Reproducibility of Results , Risk Assessment , Risk Factors , Transcatheter Aortic Valve Replacement/trends , Treatment Outcome
17.
Artif Organs ; 45(5): 454-463, 2021 May.
Article in English | MEDLINE | ID: mdl-33107042

ABSTRACT

Smart materials have intrinsic properties that change in a controlled fashion in response to external stimuli. Currently, the only smart materials with a significant clinical impact in cardiovascular implant design are shape memory alloys, particularly Nitinol. Recent prodigious progress in material science has resulted in the development of sophisticated shape memory polymers. In this article, we have reviewed the literature and outline the characteristics, advantages, and disadvantages of shape memory alloys and shape memory polymers which are relevant to clinical cardiovascular applications, and describe the potential of these smart materials for applications in coronary stents and transcatheter valves.


Subject(s)
Cardiovascular Diseases/surgery , Percutaneous Coronary Intervention/instrumentation , Polymers/therapeutic use , Smart Materials/therapeutic use , Transcatheter Aortic Valve Replacement/instrumentation , Equipment Design , Humans , Materials Testing , Percutaneous Coronary Intervention/trends , Stents/trends , Transcatheter Aortic Valve Replacement/trends
20.
Am J Cardiol ; 141: 79-85, 2021 02 15.
Article in English | MEDLINE | ID: mdl-33275895

ABSTRACT

As the use of transcatheter aortic valve implantation (TAVI) expands to varying patient populations, impacting the landscape of surgical aortic valve replacement (SAVR), this study sought to assess volume and performance trends of aortic valve replacement (AVR) in the United States during 2012-2017. The Nationwide Readmissions Database was queried for patients who underwent endovascular/transapical TAVI, isolated SAVR, or complex aortic valve surgery between 2012 and 2017. Temporal trends in annual case volume, admission costs, in-hospital outcomes, and 30-day readmission were evaluated. Of 624,303 patients (median age 72 years) who received AVR, 387,011 (62%) were men. Among these patients, 170,521 (27%) underwent TAVI and 453,782 (73%) underwent SAVR with 299,398 isolated and 154,384 complex aortic valve surgery. TAVI patients were significantly older and higher risk compared with SAVR patients. From 2012 to 2017, the annual number of TAVI increased from 8,295 to 55,168 whereas SAVR volume remained remarkably stable. Patients who underwent AVR demonstrated significant improvements in mortality, stroke, duration of hospitalization, and 30-day readmission. In conclusion, this large contemporary analysis reports the considerable growth of AVR in the United States. It remains unequivocal that the treatment of aortic stenosis is improving overall with reduced mortality following AVR, highlighting the effectiveness of various process improvements such as newer valves, enhanced patient selection, and the interdisciplinary Heart Team approach.


Subject(s)
Aortic Valve Stenosis/surgery , Hospital Mortality/trends , Patient Readmission/trends , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/trends , Acute Kidney Injury/epidemiology , Aged , Aged, 80 and over , Blood Transfusion/statistics & numerical data , Cardiac Conduction System Disease/epidemiology , Cardiac Conduction System Disease/therapy , Cardiac Pacing, Artificial , Female , Heart Valve Prosthesis Implantation/trends , Hospital Costs/trends , Humans , Length of Stay/trends , Male , Middle Aged , Pacemaker, Artificial , Retrospective Studies , Stroke/epidemiology , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...