Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.131
Filter
2.
BMJ Open ; 14(5): e080804, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38719314

ABSTRACT

OBJECTIVES: The aim of the study was to evaluate mortality and morbidity outcomes following open-heart isolated tricuspid valve surgery (TVSx) with medium to long-term follow-up. DESIGN: Retrospective cohort study. SETTING: New South Wales public and private hospital admissions between 1 January 2002 and 30 June 2018. PARTICIPANTS: A total of 537 patients underwent open isolated TVSx during the study period. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome was all-cause mortality tracked from the death registry to 31 December 2018. Secondary morbidity outcomes, including admission for congestive cardiac failure (CCF), new atrial fibrillation (AF), infective endocarditis (IE), pulmonary embolism (PE) and insertion of a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD), were tracked from the Admitted Patient Data Collection database. Independent mortality associations were determined using the Cox regression method. RESULTS: A total of 537 patients underwent open isolated TVSx (46% male): median age (IQR) was 63.5 years (43.9-73.8 years) with median length of stay of 16 days (10-31 days). Main cardiovascular comorbidities were AF (54%) and CCF (42%); 67% had rheumatic tricuspid valve. In-hospital and total mortality were 7.4% and 39.3%, respectively (mean follow-up: 4.8 years). Cause-specific deaths were evenly split between cardiovascular and non-cardiovascular causes. Predictors of mortality included a history of CCF (HR=1.78, 95% CI 1.33 to 2.38, p<0.001) and chronic pulmonary disease (HR=2.66, 95% CI 1.63 to 4.33, p<0.001). In-hospital PPM rate was 10.0%. At 180 days, 53 (9.9%) patients were admitted for CCF, 25 (10.1%) had new AF, 7 (1.5%) had new IE and <1% had PE, post-discharge PPM or ICD insertion. CONCLUSION: Open isolated TVSx carries significant mortality risk, with decompensated CCF and new AF the most common morbidities encountered after surgery. This report forms a benchmark to compare outcomes with newer percutaneous tricuspid interventions.


Subject(s)
Tricuspid Valve , Humans , Male , Female , Middle Aged , Retrospective Studies , Aged , Tricuspid Valve/surgery , New South Wales/epidemiology , Adult , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/mortality
3.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749635

ABSTRACT

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Pacemaker, Artificial/adverse effects , Male , Aged , Heart Block/therapy , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Female
4.
Echocardiography ; 41(5): e15835, 2024 May.
Article in English | MEDLINE | ID: mdl-38784978

ABSTRACT

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Prosthesis , Sensitivity and Specificity , Tricuspid Valve , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Middle Aged , Echocardiography, Doppler/methods , Retrospective Studies , Reproducibility of Results , Aged , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging
6.
Int Wound J ; 21(5): e14835, 2024 May.
Article in English | MEDLINE | ID: mdl-38786547

ABSTRACT

Tricuspid valve repair (TVR) combined with mitral valve surgery (MVS) has been a controversial issue. It is not clear whether the combined surgery has any influence on the occurrence of postoperative complications. The aim of this study was to compare the occurrence of complications including wound infection, wound bleeding, and mortality after MVS combined with or without TVR. By meta-analysis, a total of 1576 papers were collected from 3 databases, and 7 of them were included. We provided the necessary data of 7 included studies such as the authors, publication date, country, surgical approach and case number, patient age, and so on. Statistical analysis was carried out with RevMan 5.3 software. We found that patients with heart failure accepting MVS combined with or without TVR, performed no statistically significant difference in postoperative wound infection (OR: 0.88; 95% CI: 0.29, 2.62; P = 0.81), wound bleeding (OR: 0.74; 95% CI: 0.3, 1.48; P = 0.39), and mortality (OR: 1.05; 95% CI: 0.42, 2.61; P = 0.92). In conclusion, current evidence indicated that the combined surgery had no additional risk of postoperative complications, and might be an effective alternative surgical approach to mitral valve diseases accompany with tricuspid regurgitation. However, for the limited case size, it was required to support the findings with a large number of cases in further studies.


Subject(s)
Heart Failure , Postoperative Complications , Tricuspid Valve , Humans , Male , Female , Heart Failure/surgery , Heart Failure/complications , Middle Aged , Aged , Tricuspid Valve/surgery , Postoperative Complications/epidemiology , Surgical Wound Infection/etiology , Surgical Wound Infection/epidemiology , Mitral Valve/surgery , Adult , Aged, 80 and over , Cardiac Valve Annuloplasty/methods , Cardiac Valve Annuloplasty/adverse effects , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications
8.
Tunis Med ; 102(5): 315-320, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38801291

ABSTRACT

INTRODUCTION: The occurrence of death from acute pulmonary embolism (PE) is often linked to right ventricular (RV) failure, arising from an imbalance between RV systolic function and heightened RV afterload. In our study, we posited that an echocardiographic ratio derived from this disparity [RV systolic function assessed by tricuspid annular plane systolic excursion (TAPSE) divided by pulmonary arterial systolic pressure (PASP)] could offer superior predictive value for adverse outcomes compared to individual measurements of TAPSE and PASP alone. METHODS: We conducted a retrospective analysis using data from a University Hospital Centre spanning from 2017 to 2023. All individuals with confirmed PE and a formal transthoracic echocardiogram within 7 days of diagnosis were included. The primary endpoint was a composite outcome of death, hemodynamic deterioration needing introduction of inotropes or thrombolysis within 30 days. Secondary endpoints included 6 months all-cause mortality and onset of right-sided heart failure. RESULTS: Thirty-eight patients were included. Mean age was 58 ±15 years old. A male predominance was noted: 23 male patients (60.5%) and 15 female patients (39.5%). Eight patients met the primary composite endpoint while nine patients met the secondary composite endpoint. In multivariate analysis, the TAPSE/PASP ratio was independently associated with the primary outcome (OR=2.77, 95% CI 1.101-10.23, P=0.042). A TAPSE/PASP ratio <0.3 was independently associated with the secondary outcome (OR=3.07, 95% CI 1.185-10.18, P=0.034). CONCLUSION: This study suggests that a combined echocardiographic ratio of RV function to afterload is effective in predicting adverse outcomes in acute PE.


Subject(s)
Echocardiography , Pulmonary Artery , Pulmonary Embolism , Tricuspid Valve , Humans , Pulmonary Embolism/diagnosis , Pulmonary Embolism/physiopathology , Pulmonary Embolism/mortality , Pulmonary Embolism/complications , Pulmonary Embolism/diagnostic imaging , Female , Male , Middle Aged , Retrospective Studies , Prognosis , Aged , Echocardiography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Acute Disease , Adult , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Ventricular Dysfunction, Right/diagnosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology , Predictive Value of Tests , Systole/physiology
9.
Circ Heart Fail ; 17(5): e010826, 2024 May.
Article in English | MEDLINE | ID: mdl-38708598

ABSTRACT

BACKGROUND: While tricuspid annular plane systolic excursion (TAPSE) captures the predominant longitudinal motion of the right ventricle (RV), it does not account for ventricular morphology and radial motion changes in various forms of pulmonary hypertension. This study aims to account for both longitudinal and radial motions by dividing TAPSE by RV area and to assess its clinical significance. METHODS: We performed a retrospective analysis of 71 subjects with New York Heart Association class II to III dyspnea who underwent echocardiogram and invasive cardiopulmonary exercise testing (which defined 4 hemodynamic groups: control, isolated postcapillary pulmonary hypertension, combined postcapillary pulmonary hypertension, and pulmonary arterial hypertension). On the echocardiogram, TAPSE was divided by RV area in diastole (TAPSE/RVA-D) and systole (TAPSE/RVA-S). Analyses included correlations (Pearson and linear regression), receiver operating characteristic, and survival curves. RESULTS: On linear regression analysis, TAPSE/RVA metrics (versus TAPSE) had a stronger correlation with pulmonary artery compliance (r=0.48-0.54 versus 0.38) and peak VO2 percentage predicted (0.23-0.30 versus 0.18). Based on the receiver operating characteristic analysis, pulmonary artery compliance ≥3 mL/mm Hg was identified by TAPSE/RVA-D with an under the curve (AUC) of 0.79 (optimal cutoff ≥1.1) and by TAPSE/RVA-S with an AUC of 0.83 (optimal cutoff ≥1.5), but by TAPSE with only an AUC of 0.67. Similarly, to identify peak VO2 <50% predicted, AUC of 0.66 for TAPSE/RVA-D and AUC of 0.65 for TAPSE/RVA-S. Death or cardiovascular hospitalization at 12 months was associated with TAPSE/RVA-D ≥1.1 (HR, 0.38 [95% CI, 0.11-0.56]) and TAPSE/RVA-S ≥1.5 (HR, 0.44 [95% CI, 0.16-0.78]), while TAPSE was not associated with adverse outcomes (HR, 0.99 [95% CI, 0.53-1.94]). Among 31 subjects with available cardiac magnetic resonance imaging, RV ejection fraction was better correlated with novel metrics (TAPSE/RVA-D r=0.378 and TAPSE/RVA-S r=0.328) than TAPSE (r=0.082). CONCLUSIONS: In a broad cohort with suspected pulmonary hypertension, TAPSE divided by RV area was superior to TAPSE alone in correlations with pulmonary compliance and exercise capacity. As a prognostic marker of right heart function, TAPSE/RVA-D <1.1 and TAPSE/RVA-S <1.5 predicted adverse cardiovascular outcomes.


Subject(s)
Exercise Test , Exercise Tolerance , Pulmonary Artery , Ventricular Function, Right , Humans , Male , Female , Retrospective Studies , Middle Aged , Exercise Tolerance/physiology , Ventricular Function, Right/physiology , Pulmonary Artery/physiopathology , Pulmonary Artery/diagnostic imaging , Aged , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Hypertension, Pulmonary/physiopathology , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Echocardiography , Predictive Value of Tests , Prognosis
11.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599687

ABSTRACT

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery
16.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38576022

ABSTRACT

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Subject(s)
Heart Valve Prosthesis , Mitral Valve , Female , Humans , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis/adverse effects , Echocardiography , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prosthesis Design
17.
Echocardiography ; 41(4): e15804, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38578295

ABSTRACT

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Subject(s)
Bioprosthesis , Endocarditis, Bacterial , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Tricuspid Valve Stenosis , Male , Humans , Middle Aged , Adult , Bioprosthesis/adverse effects , Constriction, Pathologic , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Stenosis/diagnostic imaging , Tricuspid Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/surgery , Treatment Outcome , Prosthesis Design , Prosthesis Failure
18.
PLoS One ; 19(4): e0300716, 2024.
Article in English | MEDLINE | ID: mdl-38578764

ABSTRACT

BACKGROUND AND PURPOSE: Mean pulmonary artery pressure (mPAP) is a key index for chronic thromboembolic pulmonary hypertension (CTEPH). Using machine learning, we attempted to construct an accurate prediction model for mPAP in patients with CTEPH. METHODS: A total of 136 patients diagnosed with CTEPH were included, for whom mPAP was measured. The following patient data were used as explanatory variables in the model: basic patient information (age and sex), blood tests (brain natriuretic peptide (BNP)), echocardiography (tricuspid valve pressure gradient (TRPG)), and chest radiography (cardiothoracic ratio (CTR), right second arc ratio, and presence of avascular area). Seven machine learning methods including linear regression were used for the multivariable prediction models. Additionally, prediction models were constructed using the AutoML software. Among the 136 patients, 2/3 and 1/3 were used as training and validation sets, respectively. The average of R squared was obtained from 10 different data splittings of the training and validation sets. RESULTS: The optimal machine learning model was linear regression (averaged R squared, 0.360). The optimal combination of explanatory variables with linear regression was age, BNP level, TRPG level, and CTR (averaged R squared, 0.388). The R squared of the optimal multivariable linear regression model was higher than that of the univariable linear regression model with only TRPG. CONCLUSION: We constructed a more accurate prediction model for mPAP in patients with CTEPH than a model of TRPG only. The prediction performance of our model was improved by selecting the optimal machine learning method and combination of explanatory variables.


Subject(s)
Hypertension, Pulmonary , Pulmonary Embolism , Humans , Hypertension, Pulmonary/diagnosis , Arterial Pressure , Echocardiography/methods , Tricuspid Valve , Natriuretic Peptide, Brain , Pulmonary Embolism/complications , Pulmonary Embolism/diagnostic imaging , Chronic Disease
19.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38658105

ABSTRACT

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve , Humans , Female , Male , Aged , Pacemaker, Artificial/adverse effects , Tricuspid Valve/surgery , Middle Aged , Mitral Valve/surgery , Retrospective Studies , Cardiac Valve Annuloplasty/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...