Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.557
Filter
2.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749635

ABSTRACT

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Pacemaker, Artificial/adverse effects , Male , Aged , Heart Block/therapy , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Female
3.
Echocardiography ; 41(5): e15835, 2024 May.
Article in English | MEDLINE | ID: mdl-38784978

ABSTRACT

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Prosthesis , Sensitivity and Specificity , Tricuspid Valve , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Middle Aged , Echocardiography, Doppler/methods , Retrospective Studies , Reproducibility of Results , Aged , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging
6.
Tunis Med ; 102(5): 315-320, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38801291

ABSTRACT

INTRODUCTION: The occurrence of death from acute pulmonary embolism (PE) is often linked to right ventricular (RV) failure, arising from an imbalance between RV systolic function and heightened RV afterload. In our study, we posited that an echocardiographic ratio derived from this disparity [RV systolic function assessed by tricuspid annular plane systolic excursion (TAPSE) divided by pulmonary arterial systolic pressure (PASP)] could offer superior predictive value for adverse outcomes compared to individual measurements of TAPSE and PASP alone. METHODS: We conducted a retrospective analysis using data from a University Hospital Centre spanning from 2017 to 2023. All individuals with confirmed PE and a formal transthoracic echocardiogram within 7 days of diagnosis were included. The primary endpoint was a composite outcome of death, hemodynamic deterioration needing introduction of inotropes or thrombolysis within 30 days. Secondary endpoints included 6 months all-cause mortality and onset of right-sided heart failure. RESULTS: Thirty-eight patients were included. Mean age was 58 ±15 years old. A male predominance was noted: 23 male patients (60.5%) and 15 female patients (39.5%). Eight patients met the primary composite endpoint while nine patients met the secondary composite endpoint. In multivariate analysis, the TAPSE/PASP ratio was independently associated with the primary outcome (OR=2.77, 95% CI 1.101-10.23, P=0.042). A TAPSE/PASP ratio <0.3 was independently associated with the secondary outcome (OR=3.07, 95% CI 1.185-10.18, P=0.034). CONCLUSION: This study suggests that a combined echocardiographic ratio of RV function to afterload is effective in predicting adverse outcomes in acute PE.


Subject(s)
Echocardiography , Pulmonary Artery , Pulmonary Embolism , Tricuspid Valve , Humans , Pulmonary Embolism/diagnosis , Pulmonary Embolism/physiopathology , Pulmonary Embolism/mortality , Pulmonary Embolism/complications , Pulmonary Embolism/diagnostic imaging , Female , Male , Middle Aged , Retrospective Studies , Prognosis , Aged , Echocardiography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Acute Disease , Adult , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Ventricular Dysfunction, Right/diagnosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology , Predictive Value of Tests , Systole/physiology
7.
Circ Heart Fail ; 17(5): e010826, 2024 May.
Article in English | MEDLINE | ID: mdl-38708598

ABSTRACT

BACKGROUND: While tricuspid annular plane systolic excursion (TAPSE) captures the predominant longitudinal motion of the right ventricle (RV), it does not account for ventricular morphology and radial motion changes in various forms of pulmonary hypertension. This study aims to account for both longitudinal and radial motions by dividing TAPSE by RV area and to assess its clinical significance. METHODS: We performed a retrospective analysis of 71 subjects with New York Heart Association class II to III dyspnea who underwent echocardiogram and invasive cardiopulmonary exercise testing (which defined 4 hemodynamic groups: control, isolated postcapillary pulmonary hypertension, combined postcapillary pulmonary hypertension, and pulmonary arterial hypertension). On the echocardiogram, TAPSE was divided by RV area in diastole (TAPSE/RVA-D) and systole (TAPSE/RVA-S). Analyses included correlations (Pearson and linear regression), receiver operating characteristic, and survival curves. RESULTS: On linear regression analysis, TAPSE/RVA metrics (versus TAPSE) had a stronger correlation with pulmonary artery compliance (r=0.48-0.54 versus 0.38) and peak VO2 percentage predicted (0.23-0.30 versus 0.18). Based on the receiver operating characteristic analysis, pulmonary artery compliance ≥3 mL/mm Hg was identified by TAPSE/RVA-D with an under the curve (AUC) of 0.79 (optimal cutoff ≥1.1) and by TAPSE/RVA-S with an AUC of 0.83 (optimal cutoff ≥1.5), but by TAPSE with only an AUC of 0.67. Similarly, to identify peak VO2 <50% predicted, AUC of 0.66 for TAPSE/RVA-D and AUC of 0.65 for TAPSE/RVA-S. Death or cardiovascular hospitalization at 12 months was associated with TAPSE/RVA-D ≥1.1 (HR, 0.38 [95% CI, 0.11-0.56]) and TAPSE/RVA-S ≥1.5 (HR, 0.44 [95% CI, 0.16-0.78]), while TAPSE was not associated with adverse outcomes (HR, 0.99 [95% CI, 0.53-1.94]). Among 31 subjects with available cardiac magnetic resonance imaging, RV ejection fraction was better correlated with novel metrics (TAPSE/RVA-D r=0.378 and TAPSE/RVA-S r=0.328) than TAPSE (r=0.082). CONCLUSIONS: In a broad cohort with suspected pulmonary hypertension, TAPSE divided by RV area was superior to TAPSE alone in correlations with pulmonary compliance and exercise capacity. As a prognostic marker of right heart function, TAPSE/RVA-D <1.1 and TAPSE/RVA-S <1.5 predicted adverse cardiovascular outcomes.


Subject(s)
Exercise Test , Exercise Tolerance , Pulmonary Artery , Ventricular Function, Right , Humans , Male , Female , Retrospective Studies , Middle Aged , Exercise Tolerance/physiology , Ventricular Function, Right/physiology , Pulmonary Artery/physiopathology , Pulmonary Artery/diagnostic imaging , Aged , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Hypertension, Pulmonary/physiopathology , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Echocardiography , Predictive Value of Tests , Prognosis
9.
JACC Cardiovasc Interv ; 17(7): 837-858, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599687

ABSTRACT

Severe tricuspid regurgitation (TR) is a progressive condition associated with substantial morbidity, poor quality of life, and increased mortality. Patients with TR commonly have coexisting conditions including congestive heart failure, pulmonary hypertension, chronic lung disease, atrial fibrillation, and cardiovascular implantable electronic devices, which can increase the complexity of medical and surgical TR management. As such, the optimal timing of referral for isolated tricuspid valve (TV) intervention is undefined, and TV surgery has been associated with elevated risk of morbidity and mortality. More recently, an unprecedented growth in TR treatment options, namely the development of a wide range of transcatheter TV interventions (TTVI) is stimulating increased interest and referral for TV intervention across the entire medical community. However, there are no stepwise algorithms for the optimal management of symptomatic severe TR before TTVI. This article reviews the contemporary assessment and management of TR with addition of a medical framework to optimize TR before referral for TTVI.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery
14.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38576022

ABSTRACT

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Subject(s)
Heart Valve Prosthesis , Mitral Valve , Female , Humans , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis/adverse effects , Echocardiography , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Prosthesis Design
15.
Echocardiography ; 41(4): e15804, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38578295

ABSTRACT

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Subject(s)
Bioprosthesis , Endocarditis, Bacterial , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Tricuspid Valve Stenosis , Male , Humans , Middle Aged , Adult , Bioprosthesis/adverse effects , Constriction, Pathologic , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Stenosis/diagnostic imaging , Tricuspid Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/surgery , Treatment Outcome , Prosthesis Design , Prosthesis Failure
18.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599688

ABSTRACT

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Cardiac Catheterization/methods , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Multicenter Studies as Topic , Registries
19.
J Am Heart Assoc ; 13(8): e032929, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38563385

ABSTRACT

BACKGROUND: TRI-SCORE was recently developed in Europe as a risk model for predicting in-hospital death after isolated tricuspid valve surgery. We aimed to validate TRI-SCORE in an Asian population and investigate its value for predicting long-term outcomes. METHODS AND RESULTS: The TRI-SCORE was calculated for 202 patients (65±11 years, 61% women, 81% functional tricuspid regurgitation) who underwent isolated tricuspid valve surgery for severe tricuspid regurgitation at 2 Korean centers and was based on 8 parameters: age, New York Heart Association class, right-sided heart failure signs, furosemide daily dose, glomerular filtration rate, bilirubin, left ventricular ejection fraction, and moderate/severe right ventricular dysfunction. The primary outcome was all-cause death during follow-up; the secondary outcome was in-hospital death. During a median follow-up duration of 50 (interquartile range, 21-82) months after isolated tricuspid valve surgery, 23 (11.4%) patients experienced the primary outcome, and 7 (3.5%) patients experienced the secondary outcome. Observed all-cause death and in-hospital death increased by up to 50% in those with higher scores. Patients with the primary outcome had a higher TRI-SCORE (4.5±2.4 versus 2.9±2.1; P=0.001) than those without. The TRI-SCORE showed a significant association with the primary outcome (concordance index, 0.77, cutoff value, 4) and in-hospital death (area under the curve, 0.84; cutoff value, 3). Using the Kaplan-Meier analysis, patients with a high TRI-SCORE exhibited a poor outcome for all-cause death at follow-up (log-rank P<0.001) and in-hospital death (log-rank P=0.004). CONCLUSIONS: TRI-SCORE was validated in an Asian population and helped predict long-term outcomes after isolated tricuspid valve surgery.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Treatment Outcome , Stroke Volume , Hospital Mortality , Ventricular Function, Left , Heart Valve Prosthesis Implantation/adverse effects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...