Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 242
Filter
1.
Am Surg ; 90(6): 1781-1783, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38518211

ABSTRACT

In cases of uncontrollable hepatic hemorrhage or acute hepatic failure after trauma, liver transplantation can be a lifesaving procedure. Traumatic tricuspid valve injuries are rare, and symptoms can range from indolent to acute right heart failure. When concomitant, traumatic liver transplant and tricuspid injuries have significant physiologic interplay and management implications. We present a 14-year-old male injured in an all-terrain vehicle accident, who sustained a devastating disruption of the common bile duct and celiac artery injury, leading to acute hepatic failure, necessitating a two-stage liver transplantation. He was subsequently found to have a severe traumatic tricuspid injury, which required tricuspid valve replacement. At 4 years post-injury, he is without major complications. This is the first case presentation of the cooccurrence of these complex pathologies. Importantly, we demonstrate the complex decision-making surrounding traumatic liver transplantation and timing of subsequent tricuspid valve repair, weighing the complex interplay of these 2 pathologies.


Subject(s)
Liver Transplantation , Tricuspid Valve , Wounds, Nonpenetrating , Humans , Male , Adolescent , Wounds, Nonpenetrating/surgery , Wounds, Nonpenetrating/complications , Tricuspid Valve/injuries , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Accidents, Traffic , Liver Failure, Acute/surgery , Liver Failure, Acute/etiology , Heart Injuries/surgery , Heart Injuries/etiology
3.
Am Surg ; 89(11): 4992-4995, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36571144

ABSTRACT

Structural cardiac injury after blunt trauma is uncommon but usually life-threatening. While tricuspid injury is very rare and potentially lethal, the right heart can accommodate larger volumes and higher pressures in acute tricuspid insufficiency and facilitate initial stabilization prior to definitive valvular repair. ECMO may be used to ameliorate resulting right heart failure. The traumatic force required to cause cardiac structural injury is also associated with pulmonary complications related to pneumothorax, hemothorax, effusion, acute pain secondary to rib fractures, and pulmonary contusions causing hypoxia. We present an unusual case of hypoxia in a trauma patient caused by acute tricuspid regurgitation with pre-existing patent foramen ovale.


Subject(s)
Foramen Ovale, Patent , Heart Injuries , Tricuspid Valve Insufficiency , Wounds, Nonpenetrating , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/injuries , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/diagnostic imaging , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Heart Injuries/complications , Heart Injuries/diagnostic imaging , Hypoxia/complications , Wounds, Nonpenetrating/complications
5.
Arch Cardiovasc Dis ; 114(6-7): 482-489, 2021.
Article in English | MEDLINE | ID: mdl-34312100

ABSTRACT

BACKGROUND: Transcatheter patent arterial duct (PAD) closure in premature infants has been shown to be feasible. Since our early transcatheter PAD closure procedures in premature infants at Hôpital Necker Enfants Malades, we have changed our technique several times to advance the guidewire through the right heart to avoid tricuspid valve damage. AIM: To describe the technique we have been using since May 2019, to report our results with a particular focus on tricuspid leaks and to analyse the potential mechanisms of tricuspid lesion development with previous methods. METHODS: All premature infants weighing<2kg who underwent transcatheter PAD closure with this new technique were included. Demographic data, procedural data, outcome and procedural complications were reviewed, with particular attention to the occurrence of tricuspid regurgitation. RESULTS: Between May 2019 and May 2020, 33 patients were included. Median gestational age was 25 weeks. Median birth weight and procedural weight were 690g (range 490-1065g; interquartile range [IQR] 620-785g) and 1160g (range 900-1900g; IQR 1030-1300g), respectively. Median age at procedure was 35 (IQR 30-46) days. PAD anatomy was evaluated on transthoracic echocardiography only. The median duct diameter was 3 (IQR 2.5-3.2) mm at the pulmonary end. Success rate was 100% (defined as successful closure without residual shunt). One patient had a renal vein thrombosis, which fully resolved with low-molecular-weight heparin anticoagulation. No tricuspid regurgitation or stenosis of the left pulmonary artery or the aorta was seen. One patient died of a superior caval vein obstruction with bilateral chylothorax related to a central catheter thrombosis 56 days after the procedure, unrelated to the catheter procedure. CONCLUSION: In this prospective study, we describe a new technique to avoid tricuspid valve damage and facilitate delivery of the PAD device.


Subject(s)
Cardiac Catheterization/instrumentation , Ductus Arteriosus, Patent/therapy , Septal Occluder Device , Tricuspid Valve/physiopathology , Birth Weight , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/mortality , Ductus Arteriosus, Patent/physiopathology , Gestational Age , Heart Injuries/etiology , Heart Injuries/physiopathology , Humans , Infant , Infant, Extremely Low Birth Weight , Infant, Extremely Premature , Infant, Newborn , Paris , Recovery of Function , Time Factors , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/injuries , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Stenosis/etiology , Tricuspid Valve Stenosis/physiopathology
7.
JAAPA ; 33(9): 32-33, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32841975

ABSTRACT

In May-Thurner syndrome, or iliac vein compression syndrome, the left common iliac vein is compressed between the right common iliac artery and corresponding vertebral body, increasing patient risk for deep vein thrombosis. Iliac vein stenting for patients with symptomatic May-Thurner syndrome has become standard practice in many centers. This article describes a patient whose stent embolized completely to the right ventricle, destroying most structures in its path.


Subject(s)
Angioplasty/adverse effects , Angioplasty/methods , Cardiac Surgical Procedures/methods , Device Removal/methods , Foreign-Body Migration/etiology , Foreign-Body Migration/surgery , Heart Atria/injuries , Heart Ventricles/injuries , Iliac Vein/surgery , May-Thurner Syndrome/surgery , Stents/adverse effects , Coronary Vessels/surgery , Heart Atria/surgery , Heart Valve Prosthesis Implantation/methods , Heart Ventricles/surgery , Humans , Male , Middle Aged , Tricuspid Valve/injuries , Tricuspid Valve/surgery
8.
Catheter Cardiovasc Interv ; 96(6): 1287-1293, 2020 11.
Article in English | MEDLINE | ID: mdl-32602984

ABSTRACT

BACKGROUND: Tricuspid valve injury can occur during implantation of a SAPIEN valve in the pulmonary position. We describe our experience using a long Gore DrySeal (GDS) sheath to protect the tricuspid valve during advancement of the Commander delivery system. METHODS: Retrospective single center review of all patients who underwent placement of a SAPIEN valve in the right ventricular outflow tract between January 2016 and April 2020. Patients were divided into two groups: delivery of the valve using standard technique (Group I), and with the use of a GDS (Group II), for comparison. RESULTS: There were 48 patients in total: 25 in Group I and 23 in Group II. In Group II, the first 10 patients had a 29 mm S3 placed through a 26 French (Fr), 65 cm GDS. We then performed additional crimping of the S3 onto the balloon after the balloon catheter was withdrawn to position the valve on the balloon outside the body. Subsequently, seven had a 29 mm S3 placed through a 24 Fr GDS, and four had a 26 mm S3 placed through a 22 Fr GDS including one weighing 16 kg. Two had a 23 mm S3 placed through a 22Fr GDS as the 20Fr GDS was not available in our lab. Severe tricuspid valve injury occurred in 2/25 (8%) of Group I patients and 0/23 of Group II patients. CONCLUSION: Use of a long GDS may protect the tricuspid valve from injury during implantation of the S3 valve in the pulmonary position, and is technically feasible in smaller patients.


Subject(s)
Cardiac Catheterization/instrumentation , Heart Injuries/prevention & control , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Hemodynamics , Pulmonary Valve/surgery , Tricuspid Valve Insufficiency/prevention & control , Tricuspid Valve/physiopathology , Adolescent , Adult , Balloon Valvuloplasty , Cardiac Catheterization/adverse effects , Child , Female , Heart Injuries/diagnostic imaging , Heart Injuries/etiology , Heart Injuries/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Prosthesis Design , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/injuries , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/physiopathology , Young Adult
9.
Cardiovasc J Afr ; 31(4): 217-220, 2020.
Article in English | MEDLINE | ID: mdl-32490507

ABSTRACT

The use of peripherally inserted central catheters (PICCs) has expanded substantially for drug delivery in clinical practice in recent years. However, PICC lines expose patients to potential complications associated with an increasing incidence of infective endocarditis. We herein report a case of a 57-year-old woman who was diagnosed with tricuspid valve endocarditis by echocardiography. The most probable cause was direct injury to the tricuspid valve by the tip of a PICC line with excessive length in the right heart. The vegetation disappeared with conservative treatment after removal of the PICC line. Clinicians must maintain vigilance against any suspected PICC-related infection in febrile patients with a PICC line. For echocardiographers, precise evaluation of the position of the PICC tip and the detection of endocarditis is important to devise the optimal clinical strategy.


Subject(s)
Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheters, Indwelling/adverse effects , Endocarditis/etiology , Heart Injuries/etiology , Tricuspid Valve/injuries , Anti-Bacterial Agents/therapeutic use , Conservative Treatment , Device Removal , Endocarditis/diagnostic imaging , Endocarditis/therapy , Female , Heart Injuries/diagnostic imaging , Heart Injuries/therapy , Humans , Middle Aged , Treatment Outcome , Tricuspid Valve/diagnostic imaging
12.
Rev Bras Ter Intensiva ; 31(2): 262-265, 2019 May 30.
Article in Portuguese, English | MEDLINE | ID: mdl-31166560

ABSTRACT

Cardiac trauma often occurs in motor vehicle accidents. A 50-year-old female driver was transported to our hospital with multiple trauma after a high-speed car accident. After admission to the intensive care unit, cardiac ultrasound examination revealed traumatic tricuspid valve papillary muscle rupture and patent foramen ovale, while Lancisi's sign was noted on physical examination. Surgical treatment was performed with valve annuloplasty and closure of the patent foramen ovale and a covert right atrial defect that was detected intraoperatively.


O traumatismo cardíaco é comum em acidentes com veículos automotores. Uma mulher com 50 anos de idade foi transportada para nosso hospital após sofrer múltiplos traumatismos em um acidente de automóvel quando dirigia em alta velocidade. Após admissão à unidade de terapia intensiva, uma ultrassonografia cardíaca revelou ruptura traumática de músculo papilar da valva tricúspide e forame oval patente, enquanto se observou, no exame físico, o sinal de Lancisi. Foi realizado tratamento cirúrgico com anuloplastia da valva e fechamento do forame oval patente; durante o ato cirúrgico, diagnosticou-se ruptura oculta do átrio direito.


Subject(s)
Foramen Ovale, Patent/etiology , Heart Atria/surgery , Papillary Muscles/injuries , Tricuspid Valve/injuries , Accidents, Traffic , Cardiac Valve Annuloplasty/methods , Female , Foramen Ovale, Patent/diagnosis , Foramen Ovale, Patent/surgery , Heart Atria/injuries , Heart Injuries/diagnosis , Heart Injuries/etiology , Heart Injuries/surgery , Humans , Middle Aged , Papillary Muscles/surgery , Tricuspid Valve/surgery
13.
A A Pract ; 13(6): 233-235, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31206384

ABSTRACT

Tricuspid valve (TV) avulsion is rare and ordinarily does not require emergent intervention. We present the case of a polytrauma patient with traumatic TV avulsion who ultimately required urgent TV replacement in the setting of hemodynamic instability. Urgent TV replacement may be warranted after careful consideration of patient risk factors and clinical context.


Subject(s)
Multiple Trauma/complications , Thoracic Wall/injuries , Tricuspid Valve/injuries , Tricuspid Valve/surgery , Echocardiography, Transesophageal , Female , Humans , Middle Aged , Tricuspid Valve Insufficiency/diagnosis
14.
Rev. bras. ter. intensiva ; 31(2): 262-265, abr.-jun. 2019. graf
Article in Portuguese | LILACS | ID: biblio-1013780

ABSTRACT

RESUMO O traumatismo cardíaco é comum em acidentes com veículos automotores. Uma mulher com 50 anos de idade foi transportada para nosso hospital após sofrer múltiplos traumatismos em um acidente de automóvel quando dirigia em alta velocidade. Após admissão à unidade de terapia intensiva, uma ultrassonografia cardíaca revelou ruptura traumática de músculo papilar da valva tricúspide e forame oval patente, enquanto se observou, no exame físico, o sinal de Lancisi. Foi realizado tratamento cirúrgico com anuloplastia da valva e fechamento do forame oval patente; durante o ato cirúrgico, diagnosticou-se ruptura oculta do átrio direito.


ABSTRACT Cardiac trauma often occurs in motor vehicle accidents. A 50-year-old female driver was transported to our hospital with multiple trauma after a high-speed car accident. After admission to the intensive care unit, cardiac ultrasound examination revealed traumatic tricuspid valve papillary muscle rupture and patent foramen ovale, while Lancisi's sign was noted on physical examination. Surgical treatment was performed with valve annuloplasty and closure of the patent foramen ovale and a covert right atrial defect that was detected intraoperatively.


Subject(s)
Humans , Female , Papillary Muscles/injuries , Tricuspid Valve/injuries , Foramen Ovale, Patent/etiology , Heart Atria/surgery , Papillary Muscles/surgery , Tricuspid Valve/surgery , Accidents, Traffic , Foramen Ovale, Patent/surgery , Foramen Ovale, Patent/diagnosis , Cardiac Valve Annuloplasty/methods , Heart Atria/injuries , Heart Injuries/surgery , Heart Injuries/diagnosis , Heart Injuries/etiology , Middle Aged
16.
Zhonghua Wai Ke Za Zhi ; 57(2): 134-138, 2019 Feb 01.
Article in Chinese | MEDLINE | ID: mdl-30704218

ABSTRACT

Objective: To investigate the indication and midterm outcomes of surgical treatment of traumatic tricuspid insufficiency. Methods: Totally 19 patients with traumatic tricuspid insufficiency who underwent surgical treatment at Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University from January 2002 to January 2018 were included in this retrospective study. There were 12 male and 7 female patients, aged (43.1±12.9) years (range: 17-68 years). The main causes of traumatic tricuspid insufficiency included blunt chest trauma following high-speed vehicle accidents (17 patients) and high-fall trauma (2 patients). The preoperative New York Heart Association functional class was class Ⅱ in 5 patients, class Ⅲ in 12 patients, and class Ⅳ in 2 patients. The mechanism of tricuspid insufficiency included anterior chordal rupture in 9 patients, anterior papillary muscle rupture in 3 patients, anterior and posterior chordal or papillary muscle rupture in 4 patients, laceration of leaflet combined with chordal rupture in 2 patients and infection combined with anterior papillary muscle rupture in 1 patient. Anular dilation and enlargement of the right ventricle were observed in all the patients. Paired t test was used to evaluate the echocardiogratic results at preoperation, postoperation and follow-up. Independent sample rank sum test was used to evaluate the intervals between trauma and surgery in tricuspid valve repair group and tricuspid valve replacement group. Results: Tricuspid valve repair was successful in 8 patients, and 11 patients underwent valve replacement. Among the patients who underwent valve replacement, 6 patients received mechanical valve and 5 received bioprosthetic valve. The interval from trauma to surgery of the valve repair group and valve replacement group were 8.5(10.0) months (range: 0.1-13.0 months) and 72.0 (108.0) months (range: 2.0-228.0 months), respectively. Concomitant procedures included debridement in scalp trauma (1 patient), internal fixation of femoral fracture (1 patient). One patient died from liver failure 10 days after operation and the remaining patients survived. Eighteen patients were followed up for (94±50) months, 15 patients were in New York Heart Association functional class Ⅰ and 3 patients in class Ⅱ. One patient received redo-tricuspid valve replacement because of mechanical valve failure at the 11 years of follow-up. Conclusions: The midterm outcomes of surgical treatment of severe traumatic tricuspid insufficiency were satisfactory. Early diagnosis and surgical invention were recommended to achieve successful valve repair.


Subject(s)
Heart Injuries/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Wounds, Nonpenetrating/surgery , Adolescent , Adult , Aged , Cardiac Surgical Procedures/methods , Female , Follow-Up Studies , Heart Injuries/etiology , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Reoperation , Retrospective Studies , Treatment Outcome , Tricuspid Valve/injuries , Tricuspid Valve Insufficiency/etiology , Wounds, Nonpenetrating/complications , Young Adult
20.
PLoS One ; 13(11): e0206744, 2018.
Article in English | MEDLINE | ID: mdl-30408050

ABSTRACT

PURPOSE: Chordae rupture is one of the main lesions observed in traumatic heart events that might lead to severe tricuspid valve (TV) regurgitation. TV regurgitation following chordae rupture is often well tolerated with few or no symptoms for most patients. However, early repair of the TV is of great importance, as it might prevent further exacerbation of the regurgitation due to remodeling responses. To understand how TV regurgitation develops following this acute event, we investigated the changes on TV geometry, mechanics, and function of ex-vivo porcine hearts following chordae rupture. METHODS: Sonomicrometry techniques were employed in an ex-vivo heart apparatus to identify how the annulus geometry alters throughout the cardiac cycle after chordae rupture, leading to the development of TV regurgitation. RESULTS: We observed that the TV annulus significantly dilated (~9% in area) immediately after chordae rupture. The annulus area and circumference ranged from 11.4 ± 2.8 to 13.3 ± 2.9 cm2 and from 12.5 ± 1.5 to 13.5 ± 1.3 cm, respectively, during the cardiac cycle for the intact heart. After chordae rupture, the annulus area and circumference were larger and ranged from 12.3 ± 3.0 to 14.4 ± 2.9 cm2 and from 13.0 ± 1.5 to 14.0 ± 1.2 cm, respectively. CONCLUSIONS: In our ex-vivo study, we showed for the first time that the TV annulus dilates immediately after chordae rupture. Consequently, secondary TV regurgitation may be developed because of such changes in the annulus geometry. In addition, the TV leaflet and the right ventricle myocardium are subjected to a different mechanical environment, potentially causing further negative remodeling responses and exacerbating the detrimental outcomes of chordae rupture.


Subject(s)
Chordae Tendineae/injuries , Heart Injuries/pathology , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/injuries , Animals , Biomechanical Phenomena , Chordae Tendineae/physiopathology , Chordae Tendineae/surgery , Dilatation , Disease Models, Animal , Heart Injuries/physiopathology , Heart Injuries/surgery , Hemodynamics , In Vitro Techniques , Models, Cardiovascular , Sus scrofa , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...