1.
Sci Rep ; 14(1): 13273, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38858470

ABSTRACT

In this study, we conducted a numerical analysis on catheter sizes using computational fluid dynamics to assess urinary flow rates during intermittent catheterization (IC). The results revealed that the fluid (urine) movement within a catheter is driven by intravesical pressure, with friction against the catheter walls being the main hindrance to fluid movement. Higher-viscosity fluids experienced increased friction with increasing intravesical pressure, resulting in reduced fluid velocity, whereas lower-viscosity fluids experienced reduced friction under similar pressure, leading to increased fluid velocity. Regarding urine characteristics, the results indicated that bacteriuria, with lower viscosity, exhibited higher flow rates, whereas glucosuria exhibited the lowest flow rates. Additionally, velocity gradients decreased with increasing catheter diameters, reducing friction and enhancing fluid speed, while the friction increased with decreasing diameters, reducing fluid velocity. These findings confirm that flow rates increased with larger catheter sizes. Furthermore, in terms of specific gravity, the results showed that a 12Fr catheter did not meet the ISO-suggested average flow rate (50 cc/min). The significance of this study lies in its application of fluid dynamics to nursing, examining urinary flow characteristics in catheterization. It is expected to aid nurses in selecting appropriate catheters for intermittent catheterization based on urinary test results.


Subject(s)
Hydrodynamics , Humans , Urinary Catheters , Viscosity , Urinary Catheterization/instrumentation , Urinary Catheterization/methods , Urine/chemistry , Catheters , Friction
2.
Eur J Anaesthesiol ; 41(6): 460-461, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38690589

Subject(s)
Urine , Humans , Male , Urine/chemistry , Color , Female , Aged
3.
Sci Rep ; 14(1): 10872, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38740837

ABSTRACT

Urine is a rich source of nucleic acid biomarkers including cell-free DNA (cfDNA) and RNA for monitoring the health of kidney allografts. In this study, we aimed to evaluate whether urine filtration can serve as an alternative to the commonly used method of centrifugation to collect urinary fluid and cell pellets for isolating cfDNA and cellular messenger RNA (mRNA). We collected urine specimens from kidney allograft recipients and obtained the urine supernatant and cell pellet from each specimen using both filtration and centrifugation for paired analyses. We performed DNA sequencing to characterize the origin and properties of cfDNA, as well as quantitative PCR of mRNAs extracted from cell fractions. Our results showed that the biophysical properties of cfDNA, the microbial DNA content, and the tissues of origin of cfDNA were comparable between samples processed using filtration and centrifugation method. Similarly, mRNA quality and quantity obtained using both methods met our criteria for downstream application and the Ct values for each mRNA were comparable between the two techniques.The Ct values demonstrated a high degree of correlation. These findings suggest that urine filtration is a viable alternative to urine centrifugation for isolation of nucleic acid biomarkers from urine specimens.


Subject(s)
Biomarkers , Cell-Free Nucleic Acids , Centrifugation , Filtration , Kidney Transplantation , Humans , Centrifugation/methods , Biomarkers/urine , Filtration/methods , Cell-Free Nucleic Acids/urine , Cell-Free Nucleic Acids/isolation & purification , Cell-Free Nucleic Acids/analysis , RNA, Messenger/genetics , RNA, Messenger/urine , Male , Female , Middle Aged , Adult , Urine/chemistry
4.
Water Res ; 256: 121638, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38691899

ABSTRACT

In this study, we investigated the recovery of nitrogen (N) and phosphorus (P) from fresh source-separated urine with a novel electrochemical cell equipped with a magnesium (Mg) anode and carbon-based gas-diffusion cathode. Recovery of P, which exists primarily as phosphate (PO43-) in urine, was achieved through pH-driven precipitation. Maximizing N recovery requires simultaneous approaches to address urea and ammonia (NH3). NH3 recovery was possible through precipitation in struvite with soluble Mg supplied by the anode. Urea was stabilized with electrochemically synthesized hydrogen peroxide (H2O2) from the cathode. H2O2 concentrations and resulting urine pH were directly proportional to the applied current density. Concomitant NH3 and PO43- precipitation as struvite and urea stabilization via H2O2 electrosynthesis was possible at lower current densities, resulting in urine pH under 9.2. Higher current densities resulted in urine pH over 9.2, yielding higher H2O2 concentrations and more consistent stabilization of urea at the expense of NH3 recovery as struvite; PO43- precipitation still occurred but in the form of calcium phosphate and magnesium phosphate solids.


Subject(s)
Electrodes , Hydrogen Peroxide , Magnesium , Phosphorus , Urea , Urea/chemistry , Phosphorus/chemistry , Magnesium/chemistry , Hydrogen Peroxide/chemistry , Hydrogen-Ion Concentration , Urine/chemistry , Phosphates/chemistry , Struvite/chemistry , Ammonia/chemistry , Magnesium Compounds/chemistry , Nitrogen/chemistry , Humans
6.
Water Res ; 257: 121615, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38692253

ABSTRACT

Separate collection and treatment of urine optimizes nutrient recovery and enhances micropollutant removal from municipal wastewater. One typical urine treatment train includes nutrient recovery in three biological processes: anaerobic storage, followed by aerobic organics degradation concurrently with nitrification. These are usually followed by activated carbon adsorption to remove micropollutants. However, removing micropollutants prior to nitrification would protect nitrifiers from potential inhibition by pharmaceuticals. In addition, combining simplified biological treatment with activated carbon adsorption could offer a cheap and robust process for removing micropollutants where nutrient recovery is not the first priority, as a partial loss of ammonia occurs without nitrification. In this study, we investigated whether activated carbon adsorption could also take place between the three biological treatment steps. We tested the effectiveness of micropollutant removal with activated carbon after each biological treatment step by conducting experiments with anaerobically stored urine, organics-depleted urine, and nitrified urine. The urine solutions were spiked with 19 pharmaceuticals: amisulpride, atenolol, atenolol acid, candesartan, carbamazepine, citalopram, clarithromycin, darunavir, diclofenac, emtricitabine, fexofenadine, hydrochlorothiazide, irbesartan, lidocaine, metoprolol, N4-acetylsulfamethoxazole, sulfamethoxazole, trimethoprim, venlafaxine, and two artificial sweeteners, acesulfame and sucralose. Batch experiments were conducted with powdered activated carbon (PAC) to determine how much activated carbon achieve which degree of micropollutant removal and how organics, pH, and speciation change from ammonium to nitrate influence adsorption. Micropollutant removal was also tested in granular activated carbon (GAC) columns, which is the preferred technology for micropollutant removal from urine. The carbon usage rates (CUR) per person were lower for all urine solutions than for municipal wastewater. The results showed that organics depletion would be needed when micropollutant removal was the sole aim of urine treatment, as the degradation of easily biodegradable organics prevented clogging of GAC columns. However, CUR did hardly improve with organics-depleted urine compared to stored urine. The lowest CUR was achieved with nitrified urine. This resulted from the additional organics removal during nitrification and not the lower pH or the partial conversion of ammonium to nitrate. In addition, we showed that the relative pharmaceutical removal in all solutions was independent of the initial pharmaceutical concentration unless the background organics matrix changed considerably. We conclude that removal of micropollutants in GAC columns from organics-depleted urine can be performed without clogging, but with the drawback of a higher carbon usage compared to removal from nitrified urine.


Subject(s)
Charcoal , Nitrification , Water Pollutants, Chemical , Adsorption , Water Pollutants, Chemical/chemistry , Charcoal/chemistry , Anaerobiosis , Waste Disposal, Fluid/methods , Wastewater/chemistry , Urine/chemistry , Pharmaceutical Preparations/urine , Water Purification/methods
7.
Water Res ; 257: 121686, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38705065

ABSTRACT

This study developed a new process that stably produced ammonium nitrate (NH4NO3), an important and commonly used fertilizer, from the source-separated urine by comammox Nitrospira. In the first stage, the complete conversion of ammonium to nitrate was achieved by comammox Nitrospira. In this scenario, the pH was maintained at 6 by adding external alkali, which also provided sufficient alkalinity for full nitrification. In the second stage, the NH4NO3 was produced directly by comammox Nitropsira by converting half of the ammonium in urine into nitrate. In this case, no alkali was added and pH automatically dropped and self-maintained at an extremely acidic level (pH 3-4). In both scenarios, negligible nitrite accumulation was observed, while the final product of the second stage contained ammonium and nitrate at the molar ratio of 1:1. The dominance of comammox Nitrospira over canonical ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) was systematically proved by the combination of 16S rRNA gene amplicon sequencing, quantitative polymerase chain reaction, and metagenomics. Notably, metagenomic sequencing suggested that the relative abundance of comammox Nitrospira was over 20 % under the acidic condition at pH 3-4, while canonical AOB and NOB were undetectable. Batch experiments showed that the optimal pH for the enriched comammox Nitrospira was ∼7, which could sustain their activity in a wider pH range from 4 to 8 surprisingly but lost activity at pH 3 and 9. The findings not only present an application potential of comammox Nitrospira in nitrogen recovery from urine wastewater but also report the survivability of comammox bacteria in acidic environments.


Subject(s)
Ammonia , Nitrates , Oxidation-Reduction , Nitrates/metabolism , Hydrogen-Ion Concentration , Ammonia/metabolism , Urine/chemistry , Bacteria/metabolism , Nitrification , RNA, Ribosomal, 16S
8.
Sci Rep ; 14(1): 12001, 2024 05 25.
Article in English | MEDLINE | ID: mdl-38796538

ABSTRACT

The current study aimed to establish an experimental model in vitro and in vivo of urinary crystal deposition on the surface of ureteral stents, to evaluate the ability to prevent crystal adhesion. Non-treated ureteral stents were placed in artificial urine under various conditions in vitro. In vivo, ethylene glycol and hydroxyproline were administered orally to rats and pigs, and urinary crystals and urinary Ca were investigated by Inductively Coupled Plasma-Optical Emission Spectrometer. in vitro, during the 3- and 4-week immersion periods, more crystals adhered to the ureteral stent in artificial urine model 1 than the other artificial urine models (p < 0.01). Comparing the presence or absence of urea in the composition of the artificial urine, the artificial urine without urea showed less variability in pH change and more crystal adhesion (p < 0.05). Starting the experiment at pH 6.3 resulted in the highest amount of crystal adhesion to the ureteral stent (p < 0.05). In vivo, urinary crystals and urinary Ca increased in rat and pig experimental models. This experimental model in vitro and in vivo can be used to evaluate the ability to prevent crystal adhesion and deposition in the development of new ureteral stents to reduce ureteral stent-related side effects in patients.


Subject(s)
Stents , Animals , Rats , Swine , Male , Hydrogen-Ion Concentration , Calcium/urine , Crystallization , Ureter , Ethylene Glycol/chemistry , Hydroxyproline/urine , Urine/chemistry , Rats, Sprague-Dawley
9.
Water Res ; 257: 121751, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38744062

ABSTRACT

The human urine metabolome is complex, containing a wide range of organic metabolites that affect treatment of urine collected in resource-oriented sanitation systems. In this study, an advanced oxidation process involving heat-activated peroxydisulphate was used to selectively oxidise organic metabolites in urine over urea and chloride. Initial experiments evaluated optimal conditions (peroxydisulphate dose, temperature, time, pH) for activation of peroxydisulphate in unconcentrated, non-hydrolysed synthetic urine and real urine acidified to pH 3.0. Subsequent experiments determined the fate of 268 endogenous organic metabolites (OMs) and removal of COD from unconcentrated and concentrated real urine (80-90% mass reduced by evaporation). The results revealed >90% activation of 60 mM peroxydisulphate in real unconcentrated urine heated to 90 °C for 1 h, resulting in 43% ΣOMs degradation, 22% COD removal and 56% total organic carbon removal, while >94% of total nitrogen and >97% of urea in real unconcentrated urine were recovered. The mechanism of urea degradation was identified to be chemical hydrolysis to ammonia, with the rate constant for this reaction determined to be 1.9 × 10-6 s-1 at pH 3.0 and 90 °C. Treating concentrated real urine resulted in similar removal of COD, ΣOMs degradation and total nitrogen loss as observed for unconcentrated urine, but with significantly higher chloride oxidation and chemical hydrolysis of urea. Targeted metabolomic analysis revealed that peroxydisulphate treatment degraded 157 organic metabolites in urine, of which 67 metabolites were degraded by >80%. The rate constant for the reaction of sulphate radicals with oxidisable endogenous organic metabolites in urine was estimated to exceed 108 M-1 s-1. These metabolites were preferentially oxidised over chloride and urea in acidified, non-hydrolysed urine treated with peroxydisulphate. Overall, the findings support the development of emerging urine recycling technologies, including alkaline/acid dehydration and reverse osmosis, where the presence of endogenous organic urine metabolites significantly influences treatment parameters such as energy demand and product purity.


Subject(s)
Oxidation-Reduction , Urine , Humans , Urine/chemistry , Sulfates/metabolism , Sulfates/chemistry , Sulfates/urine , Hydrogen-Ion Concentration , Urea/metabolism , Urea/urine
10.
Sci Rep ; 14(1): 12267, 2024 05 28.
Article in English | MEDLINE | ID: mdl-38806574

ABSTRACT

Extracellular vesicles (EVs) are lipid-membrane enclosed structures that are associated with several diseases, including those of genitourinary tract. Urine contains EVs derived from urinary tract cells. Owing to its non-invasive collection, urine represents a promising source of biomarkers for genitourinary disorders, including cancer. The most used method for urinary EVs separation is differential ultracentrifugation (UC), but current protocols lead to a significant loss of EVs hampering its efficiency. Moreover, UC protocols are labor-intensive, further limiting clinical application. Herein, we sought to optimize an UC protocol, reducing the time spent and improving small EVs (SEVs) yield. By testing different ultracentrifugation times at 200,000g to pellet SEVs, we found that 48 min and 60 min enabled increased SEVs recovery compared to 25 min. A step for pelleting large EVs (LEVs) was also evaluated and compared with filtering of the urine supernatant. We found that urine supernatant filtering resulted in a 1.7-fold increase on SEVs recovery, whereas washing steps resulted in a 0.5 fold-decrease on SEVs yield. Globally, the optimized UC protocol was shown to be more time efficient, recovering higher numbers of SEVs than Exoquick-TC (EXO). Furthermore, the optimized UC protocol preserved RNA quality and quantity, while reducing SEVs separation time.


Subject(s)
Extracellular Vesicles , Ultracentrifugation , Ultracentrifugation/methods , Humans , Extracellular Vesicles/metabolism , Biomarkers/urine , Urine/cytology , Urine/chemistry , Female
11.
J Chromatogr A ; 1725: 464930, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38696889

ABSTRACT

Unsuitable sample preparation may result in loss of important analytes and consequently affect the outcome of untargeted metabolomics. Due to species differences, different sample preparations may be required within the same biological matrix. The study aimed to compare the in-house sample preparation method for urine with methods from literature and to investigate the transferability of sample preparation from human urine to rat urine. A total of 12 different conditions for protein precipitation were tested, combining four different extraction solvents and three different reconstitution solvents using an untargeted liquid-chromatography high resolution mass spectrometry (LC-HRMS) metabolomics analysis. Evaluation was done based on the impact on feature count, their detectability, as well as the reproducibility of selected compounds. Results showed that a combination of methanol as extraction and acetonitrile/water (75/25) as reconstitution solvent provided improved results at least regarding the total feature count. Additionally, it was found that a higher amount of methanol was most suitable for extraction of rat urine among the tested conditions. In comparison, human urine requires significantly less volume of extraction solvent. Overall, it is recommended to systematically optimize both, the extraction method, and the reconstitution solvent for the used biofluid and the individual analytical settings.


Subject(s)
Metabolomics , Methanol , Solvents , Animals , Rats , Metabolomics/methods , Humans , Solvents/chemistry , Methanol/chemistry , Reproducibility of Results , Chromatography, Liquid/methods , Acetonitriles/chemistry , Male , Mass Spectrometry/methods , Urine/chemistry , Water/chemistry , Urinalysis/methods
13.
Bioelectrochemistry ; 158: 108706, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38608340

ABSTRACT

Key nutrients, such as nitrogen measured as total ammonium nitrogen (TAN), could be recycled from hydrolysed human urine back to fertiliser use. Bioelectrochemical systems (BESs) are an interesting, low-energy option for realising this. However, the high TAN concentration (> 5 g L-1) and pH (> 9) of hydrolysed urine can inhibit microbial growth and hinder the enrichment of an electroactive biofilm at the anode. This study investigated a new strategy for bioanode inoculation by mixing real hydrolysed urine with thickened waste activated sludge (TWAS) from a municipal wastewater treatment plant at different volumetric ratios. The addition of TWAS diluted the high TAN concentration of hydrolysed urine (5.2 ± 0.3 g L-1) to 2.6-5.1 g L-1, while the pH of the inoculation mixtures remained > 9 and soluble chemical oxygen demand (sCOD) at 5.6-6.7 g L-1. Despite the high pH, current generation started within 24 h for all reactors, and robust bioanodes tolerant of continuous feeding with undiluted hydrolysed urine were enriched within 11 days of start-up. Current output and Coulombic efficiency decreased with increasing initial hydrolysed urine fraction. The anodes inoculated with the highest sCOD-to-TAN ratio (2.1) performed the best, which suggests that high organics levels can protect microbes from inhibition even at elevated TAN concentrations.


Subject(s)
Bioelectric Energy Sources , Urine , Humans , Urine/chemistry , Urine/microbiology , Hydrolysis , Bioelectric Energy Sources/microbiology , Electrodes , Biofilms/growth & development , Hydrogen-Ion Concentration , Sewage/microbiology , Sewage/chemistry
14.
J Hazard Mater ; 470: 134118, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38547752

ABSTRACT

Urine is the major source of nitrogen pollutants in domestic sewage and is a neglected source of H2. Although ClO• is used to overcome the poor selectivity and slow kinetics of urea decomposition, the generation of ClO• suffers from the inefficient formation reaction of HO• and reactive chlorine species (RCS). In this study, a synergistic catalytic method based on TiO2/WO3 photoanode and Sb-SnO2 electrode efficiently producing ClO• is proposed for urine treatment. The critical design is that TiO2/WO3 photoanode and Sb-SnO2 electrode that generate HO• and RCS, respectively, are assembled in a confined space through face-to-face (TiO2/WO3//Sb-SnO2), which effectively strengthens the direct reaction of HO• and RCS. Furthermore, a Si solar panel as rear photovoltaic cell (Si PVC) is placed behind TiO2/WO3//Sb-SnO2 to fully use sunlight and provide the driving force of charge separation. The composite photoanode (TiO2/WO3//Sb-SnO2 @Si PVC) has a ClO• generation rate of 260% compared with the back-to-bake assembly way. In addition, the electrons transfer to the NiFe LDH@Cu NWs/CF cathode for rapid H2 production by the constructed photoelectric catalytic (PEC) cell without applied external biasing potential, in which the H2 production yield reaches 84.55 µmol h-1 with 25% improvement of the urine denitrification rate. The superior performance and long-term stability of PEC cell provide an effective and promising method for denitrification and H2 generation.


Subject(s)
Antimony , Electrodes , Oxides , Tin Compounds , Titanium , Tungsten , Titanium/chemistry , Tungsten/chemistry , Tin Compounds/chemistry , Catalysis , Antimony/chemistry , Oxides/chemistry , Urine/chemistry , Chlorine/chemistry , Hydroxyl Radical/chemistry
15.
18.
Daru ; 32(1): 353-377, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38233724

ABSTRACT

OBJECTIVE: Urine alkalinization prevents nephrotoxicity in patients receiving high-dose methotrexate (HDMTX). While the standard approach involves IV sodium bicarbonate, alternative oral bicarbonate regimens are crucial in drug shortages and outpatient settings. This study aims to review the efficacy and safety of such regimens. METHODS: PubMed, WOS, and Scopus were systematically searched using the PRISMA protocol for relevant studies involving human subjects, including randomized clinical trials, retrospective, prospective, cohort, case reports, and case series studies. There were no restrictions on language, time, or age group. Qualified and eligible papers were used to extract data on efficacy and safety indicators, and the final relevant records were assessed for quality using the Risk of Bias in Non-Randomized Studies-of Interventions (ROBINS-I) assessment tool. RESULTS: 12 studies with 1212 participants were included in the systematic review, with pooled data from 8 studies used for meta-analysis. No significant differences in mean differences (MDs) or odds ratio (OR) were found after the oral bicarbonate regimen, except for when urine pH fell to < 7 (MD: 0.91, 95% CI: 0.32, 1.5, P < 0.05) and the incidence of diarrhea (OR: 2.92, 95% CI: 1.69, 5.05, P < 0.05). CONCLUSION: An oral bicarbonate regimen is a safe and effective way to alkalize HDMTX urine, providing a viable and cost-effective alternative to IV protocols. Further prospective multicenter studies are necessary. Systematic review registration identifier: CRD42023379666.


Subject(s)
Methotrexate , Humans , Methotrexate/administration & dosage , Administration, Oral , Sodium Bicarbonate/administration & dosage , Hydrogen-Ion Concentration , Urine/chemistry
19.
Article in German | MEDLINE | ID: mdl-37956665

ABSTRACT

Examination of the urine sediment is part of a routine urinalysis and is undertaken in order to identify insoluble particles in the urine. This procedure is mainly used in the context of diagnostic evaluation of urinary tract diseases, but may also be useful for the diagnosis of systemic diseases and intoxications. Analysis of fresh urine is recommended as changes in cell morphology, cell lysis and in vitro crystal formation may occur in the course of its storage. Manual urine sediment analysis is still performed in many veterinary practices. Native wet-mount preparations are suitable for the identification and quantification of urine sediment particles. The examination of stained wet-mount preparations or air-dried smears may be necessary to further differentiate cells and to identify bacteria. For several years, automatic urine sediment analyzers have been available in veterinary medicine. These save considerable time and staff resources, however verification of the automatically generated results by an experienced observer remains necessary. Urine sediment particles that are frequently identified and clinically relevant include red blood cells, white blood cells, different types of epithelial cells, crystals, and casts as well as bacteria. Furthermore, parasite eggs, fungal hyphae, lipid droplets, spermatozoa, fibres, hair, mucus, plant parts or environmental contaminations may be found in the urine sediment and result in a complication of the result interpretation.


Subject(s)
Cat Diseases , Dog Diseases , Humans , Male , Cats , Dogs , Animals , Cat Diseases/diagnosis , Cat Diseases/microbiology , Dog Diseases/diagnosis , Dog Diseases/microbiology , Urinalysis/veterinary , Urinalysis/methods , Urinary Sediment Analysis/veterinary , Urine/chemistry
20.
J Transl Med ; 21(1): 714, 2023 10 11.
Article in English | MEDLINE | ID: mdl-37821919

ABSTRACT

PURPOSE: Currently, there are no accurate markers for predicting potentially lethal prostate cancer (PC) before biopsy. This study aimed to develop urine tests to predict clinically significant PC (sPC) in men at risk. METHODS: Urine samples from 928 men, namely, 660 PC patients and 268 benign subjects, were analyzed by gas chromatography/quadrupole time-of-flight mass spectrophotometry (GC/Q-TOF MS) metabolomic profiling to construct four predictive models. Model I discriminated between PC and benign cases. Models II, III, and GS, respectively, predicted sPC in those classified as having favorable intermediate risk or higher, unfavorable intermediate risk or higher (according to the National Comprehensive Cancer Network risk groupings), and a Gleason sum (GS) of ≥ 7. Multivariable logistic regression was used to evaluate the area under the receiver operating characteristic curves (AUC). RESULTS: In Models I, II, III, and GS, the best AUCs (0.94, 0.85, 0.82, and 0.80, respectively; training cohort, N = 603) involved 26, 24, 26, and 22 metabolites, respectively. The addition of five clinical risk factors (serum prostate-specific antigen, patient age, previous negative biopsy, digital rectal examination, and family history) significantly improved the AUCs of the models (0.95, 0.92, 0.92, and 0.87, respectively). At 90% sensitivity, 48%, 47%, 50%, and 36% of unnecessary biopsies could be avoided. These models were successfully validated against an independent validation cohort (N = 325). Decision curve analysis showed a significant clinical net benefit with each combined model at low threshold probabilities. Models II and III were more robust and clinically relevant than Model GS. CONCLUSION: This urine test, which combines urine metabolic markers and clinical factors, may be used to predict sPC and thereby inform the necessity of biopsy in men with an elevated PC risk.


Subject(s)
Metabolome , Prostatic Neoplasms , Humans , Male , Biopsy , Neoplasm Grading , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/metabolism , Prostatic Neoplasms/pathology , Prostatic Neoplasms/urine , Risk Factors , Early Detection of Cancer/methods , Urinalysis/methods , Urine/chemistry