Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.458
Filter
1.
Methodist Debakey Cardiovasc J ; 20(3): 49-56, 2024.
Article in English | MEDLINE | ID: mdl-38765211

ABSTRACT

For patients with existing venous thromboembolisms (VTEs), anticoagulation remains the standard of care recommended across multiple professional organizations. However, for patients who developed a deep venous thrombosis (DVT) and/or a pulmonary embolism and cannot tolerate anticoagulation, inferior vena cava (IVC) filters must be considered among other alternative treatments. Although placement of a filter is considered a low-risk intervention, there are important factors and techniques that surgeons and interventionalists should be aware of and prepared to discuss. This overview covers the basics regarding the history of filters, indications for placement, associated risks, and techniques for difficult removal.


Subject(s)
Device Removal , Prosthesis Design , Prosthesis Implantation , Pulmonary Embolism , Vena Cava Filters , Venous Thrombosis , Humans , Pulmonary Embolism/prevention & control , Venous Thrombosis/prevention & control , Venous Thrombosis/therapy , Risk Factors , Prosthesis Implantation/instrumentation , Prosthesis Implantation/adverse effects , Treatment Outcome , Venous Thromboembolism/prevention & control , Venous Thromboembolism/diagnosis , Vena Cava, Inferior/diagnostic imaging , Risk Assessment , Anticoagulants/therapeutic use , Anticoagulants/adverse effects
2.
J Vis Exp ; (206)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38738890

ABSTRACT

Synthetic vascular grafts overcome some challenges of allografts, autografts, and xenografts but are often more rigid and less compliant than the native vessel into which they are implanted. Compliance matching with the native vessel is emerging as a key property for graft success. The current gold standard for assessing vessel compliance involves the vessel's excision and ex vivo biaxial mechanical testing. We developed an in vivo method to assess venous compliance and distensibility that better reflects natural physiology and takes into consideration the impact of a pressure change caused by flowing blood and by any morphologic changes present. This method is designed as a survival procedure, facilitating longitudinal studies while potentially reducing the need for animal use. Our method involves injecting a 20 mL/kg saline bolus into the venous vasculature, followed by the acquisition of pre and post bolus 3D angiograms to observe alterations induced by the bolus, concurrently with intravascular pressure measurements in target regions. We are then able to measure the circumference and the cross-sectional area of the vessel pre and post bolus. With these data and the intravascular pressure, we are able to calculate the compliance and distensibility with specific equations. This method was used to compare the inferior vena cava's compliance and distensibility in native unoperated sheep to the conduit of sheep implanted with a long-term expanded polytetrafluorethylene (PTFE) graft. The native vessel was found to be more compliant and distensible than the PTFE graft at all measured locations. We conclude that this method safely provides in vivo measurements of vein compliance and distensibility.


Subject(s)
Vena Cava, Inferior , Animals , Vena Cava, Inferior/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Sheep , Angiography/methods , Imaging, Three-Dimensional/methods , Models, Animal
3.
Saudi Med J ; 45(5): 525-530, 2024 May.
Article in English | MEDLINE | ID: mdl-38734441

ABSTRACT

OBJECTIVES: To compare vascular scanning parameters (vessel diameter, peak systolic velocity, end-diastolic velocity, and resistive index) and scanning time before and after breathing control training program for selected abdominal vessels. METHODS: This study was pre and post quasi-experimental. The researchers designed a breathing training program that gives participants instructions through a video describing breathing maneuvers. Data were collected at the ultrasound laboratory/College of Health and Rehabilitation Sciences in Princess Nourah bint Abdul Rahman University, Riyadh, Saudi Arabia from January 2023 to November 2023. About 49 volunteers at the university participated in the study. Scanning was performed two times for the right renal artery, upper abdominal aorta, inferior vena cava, and superior mesenteric artery. Scanning time was measured before and after the program as well. A paired sample t-test was used to compare the parameters means and time before and after the program. RESULTS: The program had a significant effect on the following parameters: right renal artery peak systolic velocity (p=0.042), upper abdominal aortic peak systolic velocity, and resistive index (p=0.014, p=0.014 respectively), superior mesenteric artery and inferior vena cava diameters (p=0.010 and p=0.020). The scanning time was reduced significantly (p<0.001). CONCLUSION: The breathing training program saves time and improves ultrasound measurement quality. Hospitals and health centers should consider the importance of breathing control training programs before abdominal scanning.


Subject(s)
Aorta, Abdominal , Renal Artery , Ultrasonography , Vena Cava, Inferior , Humans , Male , Ultrasonography/methods , Female , Adult , Aorta, Abdominal/diagnostic imaging , Vena Cava, Inferior/diagnostic imaging , Renal Artery/diagnostic imaging , Abdomen/diagnostic imaging , Abdomen/blood supply , Mesenteric Artery, Superior/diagnostic imaging , Young Adult , Breathing Exercises/methods , Blood Flow Velocity , Saudi Arabia , Respiration
4.
Open Vet J ; 14(4): 1076-1080, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38808297

ABSTRACT

Background: Segmental aplasia of the caudal vena cava (CVC) with azygos continuation is a congenital malformation macroscopically described in mammals including humans, dogs, and rodents. It is usually detected as an incidental finding and the final diagnosis is reached by computed tomography (CT), fluoroscopy, or post-mortem dissection. Case Description: A 3-year-old guinea pig (Cavia porcellus) presented with subacute dyspnea. A computed tomographic examination was performed for the evaluation of subtle pulmonary changes previously suspected on conventional radiography, and a segmental aplasia of the CVC with azygos continuation was identified as an incidental finding. Conclusion: According to database negative results, this is the first report describing a segmental aplasia of the CVC and azygos continuation in a guinea pig by CT.


Subject(s)
Azygos Vein , Tomography, X-Ray Computed , Vena Cava, Inferior , Animals , Tomography, X-Ray Computed/veterinary , Guinea Pigs , Azygos Vein/abnormalities , Azygos Vein/diagnostic imaging , Vena Cava, Inferior/abnormalities , Vena Cava, Inferior/diagnostic imaging , Incidental Findings , Male , Female
5.
Echocardiography ; 41(6): e15850, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38818775

ABSTRACT

BACKGROUND: Accurately stratifying patients with pulmonary arterial hypertension (PAH) is very important, and traditional risk scores still have internal heterogeneity. This study aimed to construct a risk stratification model that can accurately identify clinical worsening (CW) events in conventional low-intermediate risk patients with pulmonary hypertension under targeted drug treatment by using echocardiographic parameters. METHODS: This study is a single-center, prospective study, including 105 PAH patients who underwent regular follow-up at Guangdong Provincial People's Hospital from October 2021 to April 2023. The primary endpoint was the occurrence of CW, including death, hospitalization due to pulmonary hypertension, escalation of targeted drug therapy, and worsening of PAH. The predictive value of the echocardiography-based three-strata risk model was assessed using Kaplan-Meier curves and COX regression analysis. RESULTS: A total of 98 PAH patients were ultimately included in this study. The median follow-up duration was 26 months (range 7-28 months). The echocardiography-based three-strata model included the ratio of tricuspid annular plane systolic excursion and pulmonary artery systolic pressure (TAPSE/PASP) and inferior vena cava (IVC). The echocardiography-based three-strata model had higher diagnostic value (C-index = .76) compared to the 2022 ESC/ERS three-strata model and four-strata model (C-index = .66 and C-index = .61, respectively). PAH patients with lower TAPSE/PASP and wider IVC showed a higher CW rate compared to patients with higher TAPSE/PASP and normal IVC (HR = 15.1, 95%CI:4.4-51.9, p < .001). CONCLUSION: The echocardiography-based three-strata model based on TAPSE/PASP and IVC can effectively improve the stratification of low-intermediate risk PAH patients under targeted treatment.


Subject(s)
Echocardiography , Heart Ventricles , Pulmonary Artery , Vena Cava, Inferior , Humans , Male , Female , Echocardiography/methods , Middle Aged , Prospective Studies , Risk Assessment/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/physiopathology , Adult , Pulmonary Arterial Hypertension/physiopathology , Pulmonary Arterial Hypertension/drug therapy , Pulmonary Arterial Hypertension/complications , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/complications , Follow-Up Studies
6.
Curr Opin Crit Care ; 30(3): 260-267, 2024 06 01.
Article in English | MEDLINE | ID: mdl-38690955

ABSTRACT

PURPOSE OF REVIEW: Venous pressure is an often-unrecognized cause of patient morbidity. However, bedside assessment of PV is challenging. We review the clinical significance of venous pressure measurement, existing techniques, and introduce the Venous Excess Ultrasound (VExUS) Score as a novel approach using doppler ultrasound to assess venous pressure. RECENT FINDINGS: Studies show clear associations between elevated venous pressure and adverse outcomes in critically ill patients. Current venous pressure measurement techniques include physical examination, right heart catheterization (RHC), two-dimensional ultrasound, and a variety of labor-intensive research-focused physiological maneuvers. Each of these techniques have specific shortcomings, limiting their clinical utility. To address these gaps, Beaubien-Souligny et al. introduced the VExUS Score, a novel doppler ultrasound-based method that integrates IVC diameter with doppler measurements of the hepatic, portal, and renal veins to generate a venous congestion assesment. Studies show strong correlations between VExUS score and RHC measurements, and well as an association between VExUS score and improvement in cardiorenal acute kidney injury, diuretic response, and fluid status shifts. However, studies in noncardiac populations have been small, heterogenous, and inconclusive. SUMMARY: Early studies evaluating the use of doppler ultrasound to assess venous congestion show promise, but further research is needed in diverse patient populations and clinical settings.


Subject(s)
Ultrasonography, Doppler , Humans , Ultrasonography, Doppler/methods , Critical Illness , Venous Pressure/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/physiopathology , Monitoring, Physiologic/methods , Critical Care/methods
7.
J Cardiothorac Surg ; 19(1): 193, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38594763

ABSTRACT

In this case report, we present the unique and intriguing case of a 57-year-old man who experienced exertional palpitations and shortness of breath for 5 years. He was diagnosed with idiopathic heart failure three years ago, leading to diuretic treatment. Physical examination revealed notable left lower extremity swelling, severe varicose veins, and cardiac murmurs. Echocardiography showed significant cardiac enlargement and severe functional mitral and tricuspid valve regurgitation. Computed tomography (CT) imaging uncovered a 10 mm left common iliac arteriovenous fistula, causing abnormal early filling of the inferior vena cava (IVC) and marked IVC dilation. Open surgical repair of the arteriovenous fistula resulted in symptom relief and improved cardiac function. This case underscores the importance of considering unusual causes in heart failure patients and highlights the value of early diagnosis and intervention in complex cardiac-vascular interactions.


Subject(s)
Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Heart Failure , Tricuspid Valve Insufficiency , Humans , Male , Middle Aged , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/etiology , Echocardiography , Heart Failure/surgery , Heart Failure/complications , Tricuspid Valve Insufficiency/surgery , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery
8.
Echocardiography ; 41(5): e15823, 2024 May.
Article in English | MEDLINE | ID: mdl-38678585

ABSTRACT

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial , Vena Cava, Inferior , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Vena Cava, Inferior/diagnostic imaging , Female , Male , Adult
9.
Circ Cardiovasc Imaging ; 17(4): e016104, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38567518

ABSTRACT

BACKGROUND: The Fontan operation is a palliative technique for patients born with single ventricle heart disease. The superior vena cava (SVC), inferior vena cava (IVC), and hepatic veins are connected to the pulmonary arteries in a total cavopulmonary connection by an extracardiac conduit or a lateral tunnel connection. A balanced hepatic flow distribution (HFD) to both lungs is essential to prevent pulmonary arteriovenous malformations and cyanosis. HFD is highly dependent on the local hemodynamics. The effect of age-related changes in caval inflows on HFD was evaluated using cardiac magnetic resonance data and patient-specific computational fluid dynamics modeling. METHODS: SVC and IVC flow from 414 patients with Fontan were collected to establish a relationship between SVC:IVC flow ratio and age. Computational fluid dynamics modeling was performed in 60 (30 extracardiac and 30 lateral tunnel) patient models to quantify the HFD that corresponded to patient ages of 3, 8, and 15 years, respectively. RESULTS: SVC:IVC flow ratio inverted at ≈8 years of age, indicating a clear shift to lower body flow predominance. Our data showed that variation of HFD in response to age-related changes in caval inflows (SVC:IVC, 2, 1, and 0.5 corresponded to ages, 3, 8, and 15+, respectively) was not significant for extracardiac but statistically significant for lateral tunnel cohorts. For all 3 caval inflow ratios, a positive correlation existed between the IVC flow distribution to both the lungs and the HFD. However, as the SVC:IVC ratio changed from 2 to 0.5 (age, 3-15+) years, the correlation's strength decreased from 0.87 to 0.64, due to potential flow perturbation as IVC flow momentum increased. CONCLUSIONS: Our analysis provided quantitative insights into the impact of the changing caval inflows on Fontan's long-term HFD, highlighting the importance of SVC:IVC variations over time on Fontan's long-term hemodynamics. These findings broaden our understanding of Fontan hemodynamics and patient outcomes.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Humans , Child, Preschool , Child , Adolescent , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Vena Cava, Superior/physiology , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Liver/diagnostic imaging , Hemodynamics/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
11.
Int Angiol ; 43(2): 247-254, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38619204

ABSTRACT

INTRODUCTION: Inferior vena cava (IVC) filters act in preventing pulmonary embolisms (PE). Various complications have been reported with their use. However, a credible urological complication rate, filter characteristics, and clinical presentation has yet to be summarized. Thus, we reported these complications in the form of a systematic review. EVIDENCE ACQUISITION: A search strategy was designed using PubMed, MEDLINE, and EMBASE on February 10th, 2022. The design of this search strategy did not include any language restrictions. The key words (and wildcard terms) used in the search strategy were urolog*, ureter*, bladder, kidney coupled with filter, inferior vena cava, and cava*. Inclusion criteria were: patients older than 18, with previous IVC filter placement, and urologic complication reported. Exclusion criteria were: patients younger than 18, no IVC filter placement, and no urologic complication reported. Other case series and reviews were excluded to avoid patient duplication. EVIDENCE SYNTHESIS: Thirty-five articles were selected for full-text screening. Thirty-seven patient cases were reviewed, and the median age was 53 (range: 21-92 years old). Abdominal and or flank pain was reported in 16 (43%) patients, hematuria was seen in eight (22%) and two (5%) patients died due to acute renal failure resulting from the urologic complications of the IVC filter. Indications for IVC filter placement were recurrent pulmonary embolism (PE), contraindication to or noncompliance with anticoagulant therapy. The IVC filters were infrarenal in 29 (78.4%) patients, suprarenal in five (13.5%) patients, not reported in two patients, and misplaced into the right ovarian vein in one patient. Three or more imaging modalities were obtained in 19 patients (51%) for planning. IVC filter removal was not performed in 17 (45.9%) patients, endovascular retrieval occurred in nine (24.3%) patients, and open removal was performed in seven (18.9%) patients, and tissue interposition was performed in two (5.4%) patients. One patient did not have the management reported. CONCLUSIONS: Urological complications caused by IVC filters although rare, are likely underreported, require extensive workup, and pose surgical challenges. Due to their complex management, filter retrieval should be planned for as soon as feasible, and plans should be made as early as during the IVC filter implant. For those that do develop complications, clinical judgement must be exercised in management, and open surgical, endovascular or even conservative management strategies can be viable options and should be discussed in a multidisciplinary setting.


Subject(s)
Pulmonary Embolism , Vena Cava Filters , Vena Cava Filters/adverse effects , Humans , Aged , Female , Pulmonary Embolism/etiology , Pulmonary Embolism/prevention & control , Middle Aged , Adult , Aged, 80 and over , Male , Hematuria/etiology , Young Adult , Device Removal , Risk Factors , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Urologic Diseases/etiology , Urologic Diseases/therapy
12.
Medicine (Baltimore) ; 103(13): e37639, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38552083

ABSTRACT

RATIONALE: Renal cell carcinoma (RCC) is the most common renal neoplasm, accounting for 2.4% of all cancers in Korea. Although the usual clinical manifestations of RCC include flank pain, hematuria, and palpable mass, RCC is generally characterized by a lack of early warning signs and is mostly discovered incidentally in advanced stage. This case report describes a 42-year-old Korean man diagnosed with giant RCC who presented with simple back pain. PATIENT CONCERNS: The clinical manifestation of a 42-year-old Korean man was chronic back pain. DIAGNOSES: Contrast-enhanced computed tomography showed a 19.1-cm sized heterogeneous enhancing mass on the right kidney and tumor thrombosis extending into inferior vena cava. INTERVENTION: Due to the large size of the tumor and extensive tumor thrombosis, the multidisciplinary team decided to administer neoadjuvant chemotherapy and an anticoagulant. Following 12 cycles of treatment with nivolumab and cabozantinib, he underwent a right radical nephrectomy with an adrenalectomy and tumor thrombectomy. OUTCOMES: Treatment was successful and posttreatment he started a cancer rehabilitation program. He was followed-up as an outpatient and no longer complains of back pain. LESSONS: RCC can manifest clinically as back pain, with diagnosis being difficult without appropriate imaging modalities. RCC should be included in the differential diagnosis of patients with low back pain, even at a young age.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Low Back Pain , Thrombosis , Male , Humans , Adult , Carcinoma, Renal Cell/complications , Carcinoma, Renal Cell/diagnosis , Carcinoma, Renal Cell/surgery , Low Back Pain/etiology , Low Back Pain/pathology , Kidney Neoplasms/complications , Kidney Neoplasms/diagnosis , Kidney Neoplasms/surgery , Kidney/pathology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/pathology , Thrombosis/pathology , Nephrectomy/methods , Thrombectomy/methods
14.
Pediatr Cardiol ; 45(5): 998-1006, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38519622

ABSTRACT

We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients' post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m2, p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO2/kg/min: R: - 0.45, p = 0.01 peak, minute ventilation (VE) R: - 0.466, p < 0.01, maximal voluntary ventilation: R:0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R: 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.


Subject(s)
Exercise Test , Fontan Procedure , Heart Defects, Congenital , Pulmonary Artery , Humans , Female , Male , Heart Defects, Congenital/surgery , Heart Defects, Congenital/physiopathology , Young Adult , Exercise Test/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Adolescent , Adult , Magnetic Resonance Imaging, Cine/methods , Child , Vena Cava, Superior/diagnostic imaging , Blood Flow Velocity/physiology , Heart Failure/physiopathology , Heart Failure/surgery , Vena Cava, Inferior/diagnostic imaging
15.
BMJ Case Rep ; 17(3)2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38499354

ABSTRACT

An elderly man was referred to vascular surgery on incidental discovery of a left retroperitoneal mass ultimately found to be of left renal vein (LRV) origin. He initially presented with recurring lower back pain. CT of the abdomen/pelvis showed a 6.0×5.5 cm lobulated retroperitoneal mass anterior to the infrarenal aorta. Resection of the mass necessitated a multidisciplinary team consisting of medical oncologists, radiation oncologists, urologists and vascular surgeons. In efforts to obtain an R0 margin, en-bloc resection of the LRV from its confluence with the inferior vena cava (IVC) was necessary. A primary repair of the IVC was performed with preservation of the left kidney. The patient's back pain has since resolved after the surgery. A literature search found IVC reconstructions to be safe and effective in the removal of vascular leiomyosarcomas.


Subject(s)
Leiomyosarcoma , Vascular Neoplasms , Male , Humans , Aged , Renal Veins/diagnostic imaging , Renal Veins/surgery , Leiomyosarcoma/diagnostic imaging , Leiomyosarcoma/surgery , Neoplasm Recurrence, Local , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Kidney , Vascular Neoplasms/diagnostic imaging , Vascular Neoplasms/surgery
16.
BMJ Case Rep ; 17(3)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38514161

ABSTRACT

Inferior vena cava (IVC) filters are engineered medical devices deployed in the IVC primarily to prevent a pulmonary embolism from occurring. In this article, we present a case of an IVC filter that was successfully retrieved from a patient after being in place for 34 years. The patient presented to hospital for trauma in which subsequent imaging showed tines of an IVC filter protruding outside of the vessel with one of the tines penetrating the duodenal wall. The filter was successfully removed with no complications. This report adds to the existing literature by yielding an example of an adverse risk that can be associated with the placement of IVC filters. In addition, to the authors' best knowledge, this is the longest reported length of time that an IVC filter has stayed in a patient before being removed, thus adding another intriguing detail to the case.


Subject(s)
Pulmonary Embolism , Vena Cava Filters , Humans , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/etiology , Pulmonary Embolism/prevention & control , Device Removal , Vena Cava Filters/adverse effects , Time Factors , Retrospective Studies
17.
BMJ Case Rep ; 17(3)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38538100

ABSTRACT

Here, we report a case of a woman in her 50s who was referred for an incidentally discovered lesion anterior to the origin of inferior vena cava suspicious for a paraganglioma following a CT scan for vaginal bleeding. A follow-up 68Ga-DOTATATE PET-CT and MRI of the abdomen reinforced the radiological impression of an extra-adrenal paraganglioma (EAP). The EAP was deemed non-functional given normal urine biogenic amine, supine plasma fractionated metanephrines and chromogranin A levels. The mass was resected laparoscopically without perioperative blockade. Histological examination revealed a venous malformation. Extrahepatic abdominal venous malformations are rare and can be indistinguishable from an EAP on imaging preoperatively. Although benign, the lesion nevertheless warrants excision as it is associated with a risk of haemorrhage.


Subject(s)
Paraganglioma, Extra-Adrenal , Paraganglioma , Female , Humans , Positron Emission Tomography Computed Tomography , Paraganglioma/diagnostic imaging , Paraganglioma/surgery , Paraganglioma/complications , Paraganglioma, Extra-Adrenal/diagnostic imaging , Paraganglioma, Extra-Adrenal/surgery , Paraganglioma, Extra-Adrenal/complications , Tomography, X-Ray Computed , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery
19.
World J Surg Oncol ; 22(1): 76, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38454471

ABSTRACT

BACKGROUND: The gold standard treatment for renal cell carcinoma (RCC) with tumor thrombus (TT) is complete surgical excision. The surgery is complex and challenging to the surgeon, especially with large tumor thrombus extending into the inferior vena cava (IVC) and right atrium. Traditionally, these difficult cases required the use of cardiopulmonary bypass (CPB) with or without deep hypothermic cardiac arrest, but in recent years, different surgical techniques derived from the field of liver transplantation have been used in efforts to avoid CPB. CASE PRESENTATION: We present a case of RCC with TT level IIIc (extending above major hepatic veins) that "uncoiled" intraoperatively into the right atrium after division of the IVC ligament, transforming into a level IV TT. Despite the new TT extension, the surgery was successfully completed exclusively through an abdominal approach without CPB and while using intraoperative transesophageal echocardiography (TEE) monitoring and a cardiothoracic team standby. CONCLUSIONS: This case highlights the need for a multidisciplinary approach and the utility of intraoperative continous TEE monitoring which helped to visualize the change of the TT venous extension, allowing the surgical teamto modify their surgical approach as needed avoiding a catastrophic event.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Neoplastic Cells, Circulating , Thrombosis , Humans , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/surgery , Carcinoma, Renal Cell/pathology , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Kidney Neoplasms/pathology , Nephrectomy/methods , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/surgery , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Vena Cava, Inferior/pathology , Thrombectomy/methods , Neoplastic Cells, Circulating/pathology
20.
Clin Rheumatol ; 43(4): 1355-1362, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38386127

ABSTRACT

INTRODUCTION/OBJECTIVES: Behçet's disease (BD) affects both arterial and venous vessels. We have previously shown that common femoral vein wall thickness (WT) is increased in BD and can be used as a diagnostic test. However, there is limited data assessing large veins. Therefore, this study seeks to assess inferior vena cava wall thickness (IVC) by transthoracic echocardiography (TTE) in BD compared to healthy controls (HC). METHODS: Age- and gender-matched 70 BD patients and 51 HC were included. IVC wall thickness and common femoral vein WT were measured by TTE and Doppler ultrasonography, respectively. All examinations were performed on the same day as the clinical assessment. RESULTS: The mean IVC wall thickness of BD patients was significantly higher than HC (2.9 mm (0.3) vs 2.6 mm (0.3), p < 0.001). Patients with mucocutaneous involvement (2.8 mm (0.3)) and major organ involvement (2.9 mm (0.3)) had significantly thicker walls compared to HC (p = 0.003, p < 0.001, respectively). IVC wall thickness was higher in patients with vascular involvement compared to those with nonvascular major organ involvement (3.1 mm (0.3) vs 2.8 mm (0.2), p = 0.04). There was a moderate correlation between IVC and common femoral vein WT (r = 0.49 for the right, r = 0.43 for the left, p = 0.01 for both). CONCLUSION: This study shows that venous wall inflammation is not limited to lower extremity veins and is also present in IVC walls of BD patients regardless of IVC involvement. Vascular wall inflammation is probably a widespread vascular event of all venous walls in BD. Key Points • Venous wall inflammation is not limited to lower extremity veins and is present also in IVC wall in Behçet's disease. • Extensive venous wall inflammation in Behçet's disease includes large venous structures despite not being clinically involved.


Subject(s)
Behcet Syndrome , Humans , Behcet Syndrome/complications , Behcet Syndrome/diagnostic imaging , Vena Cava, Inferior/diagnostic imaging , Inflammation/diagnostic imaging , Femoral Vein/diagnostic imaging , Lower Extremity/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...