Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 460
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
2.
Circ Heart Fail ; 17(5): e011435, 2024 May.
Article in English | MEDLINE | ID: mdl-38695186

ABSTRACT

Hypertrophic cardiomyopathy is the most common genetic cardiac disease and is characterized by left ventricular hypertrophy. Although this hypertrophy often associates with sarcomeric gene mutations, nongenetic factors also contribute to the disease, leading to diastolic dysfunction. Notably, this dysfunction manifests before hypertrophy and is linked to hypercontractility, as well as nonuniform contraction and relaxation (myofibril asynchrony) of the myocardium. Although the distribution of hypertrophy in hypertrophic cardiomyopathy can vary both between and within individuals, in most cases, it is primarily confined to the interventricular septum. The reasons for septal thickening remain largely unknown. In this article, we propose that alterations in muscle fiber geometry, present from birth, dictate the septal shape. When combined with hypercontractility and exacerbated by left ventricular outflow tract obstruction, these factors predispose the septum to an isometric type of contraction during systole, consequently constraining its mobility. This contraction, or more accurately, this focal increase in biomechanical stress, prompts the septum to adapt and undergo remodeling. Drawing a parallel, this is reminiscent of how earthquake-resistant buildings are retrofitted with vibration dampers to absorb the majority of the shock motion and load. Similarly, the heart adapts by synthesizing viscoelastic elements such as microtubules, titin, desmin, collagen, and intercalated disc components. This pronounced remodeling in the cytoskeletal structure leads to noticeable septal hypertrophy. This structural adaptation acts as a protective measure against damage by attenuating myofibril shortening while reducing cavity tension according to Laplace Law. By examining these events, we provide a coherent explanation for the septum's predisposition toward hypertrophy.


Subject(s)
Cardiomyopathy, Hypertrophic , Humans , Cardiomyopathy, Hypertrophic/physiopathology , Myocardial Contraction/physiology , Animals , Ventricular Remodeling/physiology , Heart Septum/physiopathology , Heart Septum/diagnostic imaging , Heart Septum/pathology , Ventricular Septum/physiopathology , Ventricular Septum/diagnostic imaging
4.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38409896

ABSTRACT

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Subject(s)
Cardiac Pacing, Artificial , Ventricular Septum , Humans , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Catheters , Electrocardiography/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Ventricular Septum/diagnostic imaging
5.
Pediatr Emerg Care ; 40(6): 434-437, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38316020

ABSTRACT

BACKGROUND: Hypertrophic cardiomyopathy is a genetic, life-threatening cardiovascular disease that often goes unidentified in pediatric patients. Patients are often asymptomatic and neither history or physical examination are reliable to detect the disease. The only reliable method to diagnose hypertrophic cardiomyopathy is with echocardiography to look at interventricular septal thickness. Emerging literature has shown that cardiac point-of-care ultrasound (POCUS) performed by pediatric emergency medicine (PEM) physicians is as effective and accurate compared with cardiac echocardiography performed by pediatric cardiologists. OBJECTIVE: The objective of the study was to determine the diagnostic accuracy of POCUS performed by ultrasound-trained PEM physicians in measuring the interventricular septum end diastole (IVSd) thickness in the pediatric emergency department. METHODS: We conducted a prospective, single-center, observational, diagnostic accuracy study to examine the diagnostic accuracy of POCUS in measuring IVSd thickness in pediatric patients who presented to the pediatric emergency department with symptoms that prompted a cardiac POCUS. Cardiac POCUS findings were interpreted by a PEM physician at the bedside and retrospectively by a pediatric cardiologist. Diagnostic concordance of the measurements obtained by the PEM physician and cardiologist was assessed. RESULTS: Forty-eight patients were enrolled. Median patient age was 13.4 years. There was excellent diagnostic agreement on the measurement of the IVSd thickness between PEM physicians and the pediatric cardiologist (81.25% of cases; 39/48). Disagreement was seen in 18.75% of the cases (9/48). The mean error of disagreement was -0.32, with a 95% confidence interval of -0.37 to -0.28. Overall, the mean error of both agreement and disagreement was -0.046, with 95% confidence interval of -0.08 to -0.01 and P value of 0.008. CONCLUSIONS: Point-of-care ultrasound performed by ultrasound-trained PEM physicians to measure pediatric IVSd thickness has a high diagnostic accuracy with excellent agreement with a pediatric cardiologist.


Subject(s)
Cardiomyopathy, Hypertrophic , Echocardiography , Emergency Service, Hospital , Point-of-Care Systems , Humans , Prospective Studies , Male , Female , Child , Adolescent , Cardiomyopathy, Hypertrophic/diagnostic imaging , Echocardiography/methods , Ventricular Septum/diagnostic imaging , Child, Preschool , Infant
6.
J Cardiothorac Surg ; 19(1): 53, 2024 Feb 04.
Article in English | MEDLINE | ID: mdl-38311759

ABSTRACT

BACKGROUND: Sinus of Valsalva aneurysm (SVA) is an extremely rare condition, and its rupture causes acute symptoms such as chest pain and dyspnea. Ruptured SVA is frequently associated with other congenital defects. CASE PRESENTATION: A 37-year-old male presented with SVA originating from the left coronary sinus that ruptured into the interventricular septum. SVA was diagnosed by echocardiography, cardiac computed tomography and magnetic resonance imaging, and confirmed during the operation. CONCLUSIONS: SVA is a rare cardiac abnormality which can lead to severe clinical symptoms upon rupture. Immediate surgery is necessary to repair the ruptured SVA.


Subject(s)
Aortic Aneurysm , Aortic Diseases , Aortic Dissection , Aortic Rupture , Coronary Sinus , Sinus of Valsalva , Ventricular Septum , Male , Humans , Adult , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/surgery , Sinus of Valsalva/pathology , Ventricular Septum/diagnostic imaging , Ventricular Septum/surgery , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Diseases/complications , Aortic Rupture/diagnosis , Aortic Rupture/diagnostic imaging
7.
Cardiol Young ; 34(1): 120-125, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37231590

ABSTRACT

Pulmonary atresia with an intact ventricular septum is characterised by heterogeneity in right ventricle morphology and coronary anatomy. In some cases, the presence of ventriculocoronary connections may promote coronary artery stenosis or interruption, and aortic diastolic pressure may not be sufficient to drive coronary blood flow. This requires a correct evaluation (currently done by angiography) which depends on whether the patient can be offered decompression of the right ventricle. To date, there is no objective method to do so, so we designed a percutaneous, transitory technique with the purpose of occluding the transtricuspid anterograde flow. The manoeuverer was performed in a 25-day-old female with pulmonary atresia with intact ventricular septum, right ventricle at suprasystemic level, and selective coronarography was not conclusive, the anterior descendant with stenosis in its middle third and from this point, thinner with to-fro flow. Occlusion was performed with a balloon catheter. We re-evaluated the coronary flow and the normalised anterior descendant flow. We hope that with this new method, we can give a more accurate diagnosis and determine the cases in which the coronary circulation is truly not right ventricle dependent to offer a greater number of patients biventricular or 1.5 ventricular repairs and thereby improve their quality of life and survival, the ones that turn out to be right ventricular dependant; offer them an early reference for cardiac transplant or in case it is not available to consider univentricular palliation knowing that this probably would not reduce the risk of ischaemia and/or death over time.


Subject(s)
Heart Defects, Congenital , Pulmonary Atresia , Ventricular Septum , Humans , Female , Pulmonary Atresia/diagnostic imaging , Pulmonary Atresia/surgery , Ventricular Septum/diagnostic imaging , Ventricular Septum/surgery , Heart Ventricles , Quality of Life , Treatment Outcome , Coronary Circulation
8.
Cardiol Young ; 34(1): 189-191, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38031460

ABSTRACT

Coronary cameral fistula is a rare congenital anomaly and clinical presentation depends on the location of the defect, degree of shunting, and associated complications. We present a case of coronary cameral fistula where segmental analysis by echocardiogram helped us to avoid misdiagnosis as a ventricular septal defect.


Subject(s)
Coronary Artery Disease , Fistula , Heart Defects, Congenital , Heart Septal Defects, Ventricular , Ventricular Septum , Humans , Ventricular Septum/diagnostic imaging , Heart Septal Defects, Ventricular/diagnostic imaging
10.
Cardiol Young ; 33(12): 2676-2677, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37850484

ABSTRACT

We describe the echocardiographic findings of a common arterial trunk with intact ventricular septum, mitral and left ventricular hypoplasia, atretic left ventricular outlet and bilateral, and unbalanced pulmonary artery stenoses.


Subject(s)
Heart Defects, Congenital , Hypoplastic Left Heart Syndrome , Pulmonary Valve Stenosis , Truncus Arteriosus, Persistent , Ventricular Septum , Humans , Ventricular Septum/diagnostic imaging , Echocardiography , Pulmonary Valve Stenosis/diagnosis , Pulmonary Valve Stenosis/diagnostic imaging
12.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37748089

ABSTRACT

AIMS: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. METHODS AND RESULTS: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. CONCLUSION: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


Subject(s)
Atrioventricular Block , Ventricular Septum , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Ventricular Septum/diagnostic imaging , Heart Conduction System , Heart Ventricles/diagnostic imaging , Cardiac Conduction System Disease
13.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Article in English | MEDLINE | ID: mdl-37594233

ABSTRACT

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Subject(s)
Ventricular Septum , Humans , Male , Aged , Ventricular Septum/diagnostic imaging , Bradycardia , Cicatrix , Contrast Media , Gadolinium
15.
BMC Cardiovasc Disord ; 23(1): 346, 2023 07 12.
Article in English | MEDLINE | ID: mdl-37438743

ABSTRACT

BACKGROUND: Rare as membranous ventricular septal aneurysms (MVSA) is, the possibility that occurs after ventricular septum defect (VSD) repair surgery is even more uncommon. PRESENTATION: A girl developed a MVSA 3 years after the VSD repair surgery at the age of 1 and increasing growth was noted during the follow-up. Aneurysm plication was carried done when she was 11 years old because it was observed to have a close relationship to the right coronary and obstructed the right ventricular outflow tract. Postoperative echocardiography follow-up revealed no abnormalities. CONCLUSION: Though the prognosis of most patients with VSD repaired surgery was good, there remains varieties type of complications despite surgical advances. Accurate and rapid diagnosis of acute and delayed complications is essential to improve prognosis. In this case, the aneurysm was diagnosed by multiple imaging modalities and the girl underwent successful surgery again which provides direction for awareness and knowledge of delayed complications of VSD repair.


Subject(s)
Cardiac Surgical Procedures , Heart Aneurysm , Heart Septal Defects, Ventricular , Ventricular Septum , Female , Humans , Child , Follow-Up Studies , Ventricular Septum/diagnostic imaging , Ventricular Septum/surgery , Cardiac Surgical Procedures/adverse effects , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/surgery , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery
19.
World J Pediatr Congenit Heart Surg ; 14(3): 364-367, 2023 05.
Article in English | MEDLINE | ID: mdl-36895120

ABSTRACT

Interventricular septal hematoma is a rare and life-threatening complication of pediatric cardiac surgery. Commonly seen following ventricular septal defect repair, it has also been associated with ventricular assist device (VAD) placement. Although conservative management is usually successful, operative drainage of interventricular septal hematoma occurring in pediatric patients undergoing VAD implantation should be considered.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart Septal Defects, Ventricular , Heart-Assist Devices , Ventricular Septum , Humans , Infant , Child , Heart-Assist Devices/adverse effects , Ventricular Septum/diagnostic imaging , Cardiac Surgical Procedures/adverse effects , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Heart Septal Defects, Ventricular/complications , Hematoma/diagnostic imaging , Hematoma/etiology , Hematoma/surgery , Heart Failure/etiology
20.
Am J Cardiol ; 193: 111-117, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36898244

ABSTRACT

Described herein are 4 patients who underwent orthotopic heart transplant (OHT) because of heart failure caused by acute myocardial infarcts which healed. These healed infarcts were the result of preferential severe narrowing of the left anterior descending coronary artery. In all 4 cases, the myocardial infarct caused severe scarring of the ventricular septum (VS), more than that observed in the left ventricular free wall where most myocardial infarcts secondary to coronary artery narrowing typically occur.


Subject(s)
Heart Failure , Heart Transplantation , Myocardial Infarction , Ventricular Septum , Humans , Ventricular Septum/diagnostic imaging , Myocardial Infarction/complications , Heart Ventricles/diagnostic imaging , Heart Failure/complications , Heart Transplantation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...