1.
BMC Ophthalmol ; 24(1): 233, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831268

ABSTRACT

BACKGROUND: The long-term safety and efficacy of repeated applications of subliminal transscleral cyclophotocoagulation (SL-TSCPC) with a focus on cumulative energy was evaluated in glaucoma patients. METHODS: In this retrospective, multicentric study the data of a total of 82 eyes with various causes of glaucoma that were treated with a single or multiple applications of SL-TSCPC were collected. Treatments were performed under general or local anesthesia with an 810 nm diode laser. Power was 2000 mW; duty cycle, 31.3%; total treatment duration, 80-320 s; equaling a total energy of 50-200 J per treatment session. Fifty-five eyes (55 patients) presented for all follow-ups, and these eyes were selected for further statistical analysis. The mean age was 60.0 ± 17.1 years, and 22 (40%) of the patients were female. Intraocular pressure (IOP) and dependence on further glaucoma medication were evaluated at 12 months following the initial treatment. RESULTS: Eyes underwent 1 or 2 consecutive SL-TSCPC treatments. Median (min-max) baseline IOP of 34 (13-69) decreased to 21.5 (7-61), 22 (8-68), 20 (9-68), and 19.5 (3-60) mmHg at the 1, 3, 6, and 12-month postoperative timepoints respectively. The mean (± SD) IOP decrease at 12 months was 26 ± 27%, 39 ± 32%, and 49 ± 33% in the low (below 120 J, n = 18), medium (120-200 J, n = 24), and high (above 200 J, n = 13) cumulative energy groups respectively. At the 12-month timepoint, oral carbonic anhydrase use was discontinued in ¾ of the cases. CONCLUSIONS: It was found that the repeated application of SL-TSCPC safely and efficiently decreases IOP in a Caucasian population with heterogenous causes of glaucoma, eyes with silicone oil responded to a greater extent. Inclusion of cumulative energy scales may contribute to better addressing repeated procedures in a standardized fashion.


Subject(s)
Ciliary Body , Glaucoma , Intraocular Pressure , Laser Coagulation , Lasers, Semiconductor , Sclera , Humans , Retrospective Studies , Female , Male , Middle Aged , Intraocular Pressure/physiology , Laser Coagulation/methods , Ciliary Body/surgery , Aged , Sclera/surgery , Glaucoma/surgery , Glaucoma/physiopathology , Adult , Lasers, Semiconductor/therapeutic use , Visual Acuity/physiology , Aged, 80 and over , Follow-Up Studies , Treatment Outcome
2.
Invest Ophthalmol Vis Sci ; 65(6): 5, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38833260

ABSTRACT

Purpose: The purpose of this study was to evaluate self-reported functional vision (FV) and the impact of vision loss in patients with USH2A-associated retinal degeneration using a patient-reported outcome (PRO) measure, the Michigan Retinal Degeneration Questionnaire (MRDQ), to correlate MRDQ scores with well-established visual function measurements. Design: An observational cross-sectional study (n = 93) of participants who had Usher Syndrome Type 2 (USH2, n = 55) or autosomal recessive non-syndromic retinitis pigmentosa (ARRP; n = 38) associated with biallelic variants in the USH2A gene. Methods: The study protocol was approved by all ethics boards and informed consent was obtained from each participant. Participants completed the MRDQ at the 48-month study follow-up visit. Disease duration was self-reported by participants. One-way ANOVA was used to compare subgroups (clinical diagnosis, age, disease duration, and full-field stimulus threshold [FST] Blue-Red mediation) on mean scores per domain. Spearman correlation coefficients were used to assess associations between MRDQ domains and visual/retinal function assessments. Results: Of the study sample, 58% were female participants and the median disease duration was 13 years. MRDQ domains were sensitive to differences between subgroups of clinical diagnosis, age, disease duration, and FST Blue-Red mediation. MRDQ domains correlated with static perimetry, microperimetry, full-field stimulus testing, and best-corrected visual acuity (BCVA). Conclusions: Self-reported FV measured by the MRDQ, when applied to USH2 and ARRP participants, had good distributional characteristics and correlated well with visual function tests. MRDQ adds a new dimension of understanding on vision-related functioning and establishes this PRO tool as an informative measure in evaluating USH2A outcomes.


Subject(s)
Extracellular Matrix Proteins , Self Report , Usher Syndromes , Visual Acuity , Humans , Female , Male , Cross-Sectional Studies , Middle Aged , Visual Acuity/physiology , Extracellular Matrix Proteins/genetics , Adult , Usher Syndromes/genetics , Usher Syndromes/physiopathology , Usher Syndromes/diagnosis , Surveys and Questionnaires , Retinal Degeneration/genetics , Retinal Degeneration/physiopathology , Retinal Degeneration/diagnosis , Aged , Young Adult , Quality of Life , Adolescent , Retinitis Pigmentosa/genetics , Retinitis Pigmentosa/physiopathology , Retinitis Pigmentosa/diagnosis
3.
Eur J Ophthalmol ; 34(3): NP97-NP100, 2024 May.
Article in English | MEDLINE | ID: mdl-38699790

ABSTRACT

INTRODUCTION: We present a single-eyed case with a previous diagnosis of breast cancer who had intraretinal cystoid changes associated with the systemic administration of ixabepilone in her only seeing eye. To our best knowledge, this is the first reported case describing this phenomenon related to the ixabepilone administration. CASE DESCRIPTION: A 54-year-old woman with a history of breast cancer was examined due to visual deterioration in her only good left eye. The patient had undergone cataract surgery and lens implantation in her right eye following a childhood accident, but subsequently had developed a refractory glaucoma and lost her right vision. Six cycles of 40 mg/m2 systemic ixabepilone (3-hly intravenous infusion once every 3 weeks) had been administered within the past six months. Her visual decline started two weeks following the last treatment session. She was offered intravitreal anti-vascular endothelial growth factor injection elsewhere. Fluorescein angiogram showed no dye leakage whereas spectral-domain optical coherence tomography demonstrated parafoveal intraretinal cystoid changes. En-face optical coherence tomography revealed petaloid type roundish hyporeflective areas at the level of superficial and deep vascular plexus. Ixabepilone-associated cystoid maculopathy was suspected as she received only ixabepilone for the chemotherapy in the last six months. We thus recommended her not to continue ixabepilone therapy. Ten weeks after the ixabepilone cessation, intraretinal cystoid changes had resolved completely. CONCLUSION: Angiographically silent intraretinal cystoid changes may develop in association with the use of ixabepilone. Referral to an ophthalmologist should be considered for the patients experiencing visual complaints as ixabepilone cessation may lead to visual improvement and avoid unnecessary treatment.


Subject(s)
Breast Neoplasms , Epothilones , Fluorescein Angiography , Macular Edema , Tomography, Optical Coherence , Visual Acuity , Humans , Female , Middle Aged , Macular Edema/drug therapy , Macular Edema/diagnosis , Epothilones/adverse effects , Epothilones/administration & dosage , Visual Acuity/physiology , Breast Neoplasms/drug therapy , Fundus Oculi
4.
BMC Ophthalmol ; 24(1): 205, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711013

ABSTRACT

PURPOSE: To summarize the outcomes of corneal sight rehabilitating surgery in Stevens-Johnson syndrome (SJS). METHODS: This is a retrospective analysis of a consecutive case series. Twenty-four eyes of 18 SJS patients were included in this study. The ocular parameters, surgical procedures, postoperative complications, and additional treatments of the cases were reviewed. RESULTS: A total of 29 corneal sight rehabilitating surgeries, which consists of 9 keratoplasties, 8 Keratolimbal allograft (KLAL) and 12 combined surgeries (keratoplasty and KLAL simultaneously) were performed on the 24 eyes. All patients were treated with glucocorticoid eyedrops and tacrolimus eyedrops for anti-rejection treatment without combining systemic immunosuppression, except two patients who were prescribed prednisone tablets for the management of systemic conditions. The mean follow-up period was 50.6 ± 28.1 months. The optimal visual acuity (VA) (0.74 ± 0.60 logarithm of the minimum angle of resolution [logMAR]) and endpoint VA (1.06 ± 0.82 logMAR) were both significantly better than the preoperative VA (1.96 ± 0.43 logMAR) (95% CI, p = 0.000). 57.1% patients (8/14) were no longer in the low vision spectrum, and 88.9% patients (8/9) were no longer blind. The mean epithelialization time was 7.1 ± 7.6 weeks. The success rate was 86.7%. Additional treatments for improving epithelialization included administration of serum eyedrops (n = 10), contact lens (n = 15), amniotic membrane transplantation (n = 6), and tarsorrhaphy (n = 8). Complications included delayed epithelialization (n = 4, over 12 weeks), glaucoma (n = 11), and severe allograft opacity (n = 4). Only one graft rejection was observed. CONCLUSIONS: Keratoplasty and KLAL can remarkably enhance VA and improve low vision or even eliminate blindness for ocular complications of SJS. The outcome of the surgeries was correlated with the preoperative ocular situation and choice of operative methods.


Subject(s)
Corneal Diseases , Stevens-Johnson Syndrome , Visual Acuity , Humans , Stevens-Johnson Syndrome/surgery , Stevens-Johnson Syndrome/physiopathology , Retrospective Studies , Female , Male , Adult , Visual Acuity/physiology , Middle Aged , Young Adult , Adolescent , Corneal Diseases/surgery , Corneal Diseases/physiopathology , Treatment Outcome , Child , Corneal Transplantation/methods , Follow-Up Studies , Keratoplasty, Penetrating/methods , Postoperative Complications , Limbus Corneae/surgery
5.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711043

ABSTRACT

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Subject(s)
Biometry , Refraction, Ocular , Visual Acuity , Humans , Female , Male , Cross-Sectional Studies , China/epidemiology , Refraction, Ocular/physiology , Child, Preschool , Child , Visual Acuity/physiology , Prevalence , Axial Length, Eye , Cornea/pathology , Cornea/anatomy & histology , Refractive Errors/epidemiology , Refractive Errors/physiopathology , Anterior Chamber/diagnostic imaging , Anterior Chamber/pathology , Myopia/epidemiology , Myopia/physiopathology
6.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711059

ABSTRACT

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Subject(s)
Cataract , Lens Nucleus, Crystalline , Tomography, Optical Coherence , Visual Acuity , Humans , Female , Male , Tomography, Optical Coherence/methods , Cataract/diagnosis , Aged , Middle Aged , Lens Nucleus, Crystalline/pathology , Lens Nucleus, Crystalline/diagnostic imaging , Visual Acuity/physiology , ROC Curve , Retrospective Studies , Phacoemulsification , Aged, 80 and over , Adult , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/pathology
7.
Invest Ophthalmol Vis Sci ; 65(5): 7, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38700875

ABSTRACT

Purpose: This study aimed to explore the underlying mechanisms of the observed visuomotor deficit in amblyopia. Methods: Twenty-four amblyopic (25.8 ± 3.8 years; 15 males) and 22 normal participants (25.8 ± 2.1 years; 8 males) took part in the study. The participants were instructed to continuously track a randomly moving Gaussian target on a computer screen using a mouse. In experiment 1, the participants performed the tracking task at six different target sizes. In experiments 2 and 3, they were asked to track a target with the contrast adjusted to individual's threshold. The tracking performance was represented by the kernel function calculated as the cross-correlation between the target and mouse displacements. The peak, latency, and width of the kernel were extracted and compared between the two groups. Results: In experiment 1, target size had a significant effect on the kernel peak (F(1.649, 46.170) = 200.958, P = 4.420 × 10-22). At the smallest target size, the peak in the amblyopic group was significantly lower than that in the normal group (0.089 ± 0.023 vs. 0.107 ± 0.020, t(28) = -2.390, P = 0.024) and correlated with the contrast sensitivity function (r = 0.739, P = 0.002) in the amblyopic eyes. In experiments 2 and 3, with equally visible stimuli, there were still differences in the kernel between the two groups (all Ps < 0.05). Conclusions: When stimulus visibility was compensated, amblyopic participants still showed significantly poorer tracking performance.


Subject(s)
Amblyopia , Visual Acuity , Humans , Amblyopia/physiopathology , Male , Female , Adult , Young Adult , Visual Acuity/physiology , Psychophysics/methods , Motion Perception/physiology , Contrast Sensitivity/physiology , Eye Movements/physiology
8.
Invest Ophthalmol Vis Sci ; 65(5): 10, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38709525

ABSTRACT

Purpose: The purpose of this study was to investigate the incidence of foveal involvement in geographic atrophy (GA) secondary to age-related macular degeneration (AMD), using machine learning to assess the importance of risk factors. Methods: Retrospective, longitudinal cohort study. Patients diagnosed with foveal-sparing GA, having GA size ≥ 0.049 mm² and follow-up ≥ 6 months, were included. Baseline GA area, distance from the fovea, and perilesional patterns were measured using fundus autofluorescence. Optical coherence tomography assessed foveal involvement, structural biomarkers, and outer retinal layers thickness. Onset of foveal involvement was recorded. Foveal survival rates were estimated using Kaplan-Meier curves. Hazard ratios (HRs) were assessed with mixed model Cox regression. Variable Importance (VIMP) was ranked with Random Survival Forests (RSF), with higher scores indicating greater predictive significance. Results: One hundred sixty-seven eyes (115 patients, average age = 75.8 ± 9.47 years) with mean follow-up of 50 ± 29 months, were included in this study. Median foveal survival time was 45 months (95% confidence interval [CI] = 38-55). Incidences of foveal involvement were 26% at 24 months and 67% at 60 months. Risk factors were GA proximity to the fovea (HR = 0.97 per 10-µm increase, 95% CI = 0.96-0.98), worse baseline visual acuity (HR = 1.37 per 0.1 LogMAR increase, 95% CI = 1.21-1.53), and thinner outer nuclear layer (HR = 0.59 per 10-µm increase, 95% CI = 0.46-0.74). RSF analysis confirmed these as main predictors (VIMP = 16.7, P = 0.002; VIMP = 6.2, P = 0.003; and VIMP = 3.4, P = 0.01). Lesser baseline GA area (HR = 1.09 per 1-mm2 increase, 95% CI = 1.01-1.16) and presence of a double layer sign (HR = 0.42, 95% CI = 0.20-0.88) were protective but less influential. Conclusions: This study identifies anatomic and functional factors impacting the risk of foveal involvement in GA. These findings may help identify at-risk patients, enabling tailored preventive strategies.


Subject(s)
Fovea Centralis , Geographic Atrophy , Machine Learning , Tomography, Optical Coherence , Humans , Fovea Centralis/pathology , Fovea Centralis/diagnostic imaging , Male , Female , Geographic Atrophy/diagnosis , Aged , Retrospective Studies , Tomography, Optical Coherence/methods , Risk Factors , Aged, 80 and over , Visual Acuity/physiology , Follow-Up Studies , Fluorescein Angiography/methods , Incidence , Middle Aged , Survival Analysis
9.
Aerosp Med Hum Perform ; 95(5): 278-281, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38715272

ABSTRACT

BACKGROUND: This article documents the stability of photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) in two astronauts during 6-mo missions to the International Space Station.CASE REPORTS: Ocular examinations including visual acuity, cycloplegic refraction, slit lamp examination, corneal topography, central corneal thickness, optical biometry (axial length/keratometry), applanation tonometry, and dilated fundus examination were performed on each astronaut before and after their missions, and in-flight visual acuity testing was done on flight day 30, 90, and R-30 (30 d before return). They were also questioned regarding visual changes during flight.DISCUSSION: We documented stable vision in both PRK and LASIK astronauts during liftoff, entry into microgravity, 6 mo on the International Space Station, descent, and landing. Our results suggest that both PRK and LASIK are stable and well tolerated during long-duration spaceflight.Gibson CR, Mader TH, Lipsky W, Schallhorn SC, Tarver WJ, Suresh R, Hauge TN, Brunstetter TJ. Photorefractive keratectomy and laser-assisted in situ keratomileusis on 6-month space missions. Aerosp Med Hum Perform. 2024; 95(5):278-281.


Subject(s)
Astronauts , Keratomileusis, Laser In Situ , Photorefractive Keratectomy , Space Flight , Visual Acuity , Humans , Photorefractive Keratectomy/methods , Keratomileusis, Laser In Situ/methods , Male , Adult , Visual Acuity/physiology , Aerospace Medicine , Middle Aged , Myopia/surgery , Myopia/physiopathology
10.
Arq Bras Oftalmol ; 87(3): e20230257, 2024.
Article in English | MEDLINE | ID: mdl-38716966

ABSTRACT

PURPOSE: This review emphasizes the effect of light on visual efficiency, the impact of different lighting focuses, types of lighting, and their influence on vision and productivity. Light sources and standards are intriguing subjects for ophthalmologists. Guidelines regarding the level of lighting influence on visual activities can enhance visual performance.Methods: This article was developed based on literature reviews, with a bibliographic survey conducted in databases such as PubMed, MEDLINE, Web of Science, Embase, LILACS, and SciELO. RESULTS: Provides recommendations for understanding information regarding the influence of lighting on visual performance. CONCLUSION: Proper workplace lighting is crucial for improving visual efficiency, safety, productivity, and worker health. Efficient workplace lighting should avoid light sources directed towards the worker's face, prevent harmful glare, be more intense in the work area, and uniform in the rest of the room. Ophthalmologists should be knowledgeable about and provide guidance on correct lighting to ensure patient comfort and satisfaction with visual correction.


Subject(s)
Lighting , Humans , Vision, Ocular/physiology , Visual Acuity/physiology , Workplace , Occupational Health , Glare , Light
11.
J Refract Surg ; 40(5): e313-e320, 2024 May.
Article in English | MEDLINE | ID: mdl-38717079

ABSTRACT

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Subject(s)
Hyperopia , Lens Implantation, Intraocular , Myopia , Phakic Intraocular Lenses , Refraction, Ocular , Visual Acuity , Humans , Retrospective Studies , Male , Visual Acuity/physiology , Female , Adult , Myopia/surgery , Myopia/physiopathology , Refraction, Ocular/physiology , Hyperopia/surgery , Hyperopia/physiopathology , Young Adult , Treatment Outcome , Middle Aged , Postoperative Complications , Follow-Up Studies , Adolescent
12.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Article in English | MEDLINE | ID: mdl-38717080

ABSTRACT

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Subject(s)
Astigmatism , Corneal Stroma , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Astigmatism/physiopathology , Astigmatism/surgery , Visual Acuity/physiology , Retrospective Studies , Adult , Refraction, Ocular/physiology , Male , Female , Myopia/surgery , Myopia/physiopathology , Young Adult , Corneal Stroma/surgery , Lasers, Excimer/therapeutic use , Corneal Topography , Follow-Up Studies , Treatment Outcome , Corneal Surgery, Laser/methods
13.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Article in English | MEDLINE | ID: mdl-38717081

ABSTRACT

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Subject(s)
Corneal Topography , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Surgery, Computer-Assisted , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Visual Acuity/physiology , Prospective Studies , Refraction, Ocular/physiology , Adult , Male , Female , Lasers, Excimer/therapeutic use , Double-Blind Method , Myopia/surgery , Myopia/physiopathology , Young Adult , Surgery, Computer-Assisted/methods , Middle Aged , Cornea/surgery , Cornea/physiopathology , Follow-Up Studies
14.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Article in English | MEDLINE | ID: mdl-38717083

ABSTRACT

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Subject(s)
Aberrometry , Astigmatism , Cornea , Corneal Stroma , Corneal Wavefront Aberration , Densitometry , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Refraction, Ocular , Visual Acuity , Humans , Keratomileusis, Laser In Situ/methods , Corneal Wavefront Aberration/physiopathology , Prospective Studies , Myopia/surgery , Myopia/physiopathology , Adult , Female , Male , Lasers, Excimer/therapeutic use , Visual Acuity/physiology , Corneal Stroma/surgery , Cornea/surgery , Cornea/physiopathology , Young Adult , Refraction, Ocular/physiology , Astigmatism/surgery , Astigmatism/physiopathology , Corneal Surgery, Laser/methods , Corneal Topography
15.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Article in English | MEDLINE | ID: mdl-38717085

ABSTRACT

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Subject(s)
Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Visual Acuity , Humans , Prospective Studies , Intraocular Pressure/physiology , Male , Female , Aged , Visual Acuity/physiology , Middle Aged , Endothelium, Corneal/pathology , Cell Count , Postoperative Period , Tomography, Optical Coherence , Hydrodynamics , Anterior Chamber , Intraoperative Period
16.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Article in English | MEDLINE | ID: mdl-38717082

ABSTRACT

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Subject(s)
Corneal Stroma , Corneal Topography , Epithelium, Corneal , Hyperopia , Refraction, Ocular , Tomography, Optical Coherence , Visual Acuity , Humans , Hyperopia/surgery , Hyperopia/physiopathology , Prospective Studies , Corneal Stroma/surgery , Corneal Stroma/pathology , Male , Female , Adult , Visual Acuity/physiology , Epithelium, Corneal/surgery , Epithelium, Corneal/pathology , Refraction, Ocular/physiology , Middle Aged , Lasers, Excimer/therapeutic use , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Surgery, Laser/methods , Eye Diseases, Hereditary
17.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Article in English | MEDLINE | ID: mdl-38717086

ABSTRACT

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Subject(s)
Cornea , Elasticity , Intraocular Pressure , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Humans , Cornea/physiopathology , Cornea/surgery , Adult , Female , Male , Biomechanical Phenomena , Lasers, Excimer/therapeutic use , Keratomileusis, Laser In Situ/methods , Young Adult , Elasticity/physiology , Myopia/surgery , Myopia/physiopathology , Intraocular Pressure/physiology , Photorefractive Keratectomy/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Prospective Studies , Corneal Surgery, Laser/methods , Corneal Topography
18.
Invest Ophthalmol Vis Sci ; 65(5): 17, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38717424

ABSTRACT

Purpose: We aimed to identify structural differences in normal eyes, early age-related macular degeneration (AMD), and intermediate AMD eyes using optical coherence tomography (OCT) in a well-characterized, large cross-sectional cohort. Methods: Subjects ≥ 60 years with healthy normal eyes, as well as early or intermediate AMD were enrolled in the Alabama Study on Age-related Macular Degeneration 2 (ALSTAR2; NCT04112667). Using Spectralis HRA + OCT2, we obtained macular volumes for each participant. An auto-segmentation software was used to segment six layers and sublayers: photoreceptor inner and outer segments, subretinal drusenoid deposits (SDDs), retinal pigment epithelium + basal lamina (RPE + BL), drusen, and choroid. After manually refining the segmentations of all B-scans, mean thicknesses in whole, central, inner and outer rings of the ETDRS grid were calculated and compared among groups. Results: This study involved 502 patients, 252 were healthy, 147 had early AMD, and 103 had intermediate AMD eyes (per Age-Related Eye Disease Study [AREDS] 9-step). Intermediate AMD eyes exhibited thicker SDD and drusen, thinner photoreceptor inner segments, and RPE compared to healthy and early AMD eyes. They also had thicker photoreceptor outer segments than early AMD eyes. Early AMD eyes had thinner photoreceptor outer segments than normal eyes but a thicker choroid than intermediate AMD eyes. Using the Beckman scale, 42% of the eyes initially classified as early AMD shifted to intermediate AMD, making thickness differences for photoreceptor outer segments and choroid insignificant. Conclusions: With AMD stages, the most consistent structural differences involve appearance of drusen and SDD, followed by RPE + BL thickness, and then thickness of photoreceptor inner and outer segments. Structural changes in the transition from aging to intermediate AMD include alterations in the outer retinal bands, including the appearance of deposits on either side of the RPE.


Subject(s)
Choroid , Macular Degeneration , Retinal Drusen , Retinal Pigment Epithelium , Tomography, Optical Coherence , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Choroid/pathology , Choroid/diagnostic imaging , Cross-Sectional Studies , Macular Degeneration/diagnosis , Retinal Drusen/diagnosis , Retinal Photoreceptor Cell Outer Segment/pathology , Retinal Pigment Epithelium/pathology , Retinal Pigment Epithelium/diagnostic imaging , Tomography, Optical Coherence/methods , Visual Acuity/physiology
19.
PLoS One ; 19(5): e0303400, 2024.
Article in English | MEDLINE | ID: mdl-38739635

ABSTRACT

Visual abilities tend to vary predictably across the visual field-for simple low-level stimuli, visibility is better along the horizontal vs. vertical meridian and in the lower vs. upper visual field. In contrast, face perception abilities have been reported to show either distinct or entirely idiosyncratic patterns of variation in peripheral vision, suggesting a dissociation between the spatial properties of low- and higher-level vision. To assess this link more clearly, we extended methods used in low-level vision to develop an acuity test for face perception, measuring the smallest size at which facial gender can be reliably judged in peripheral vision. In 3 experiments, we show the characteristic inversion effect, with better acuity for upright faces than inverted, demonstrating the engagement of high-level face-selective processes in peripheral vision. We also observe a clear advantage for gender acuity on the horizontal vs. vertical meridian and a smaller-but-consistent lower- vs. upper-field advantage. These visual field variations match those of low-level vision, indicating that higher-level face processing abilities either inherit or actively maintain the characteristic patterns of spatial selectivity found in early vision. The commonality of these spatial variations throughout the visual hierarchy means that the location of faces in our visual field systematically influences our perception of them.


Subject(s)
Facial Recognition , Visual Fields , Humans , Visual Fields/physiology , Female , Male , Adult , Facial Recognition/physiology , Young Adult , Photic Stimulation , Visual Perception/physiology , Visual Acuity/physiology , Face/physiology
20.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38750496

ABSTRACT

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Subject(s)
Cataract , Laser Therapy , Phacoemulsification , Tomography, Optical Coherence , Visual Acuity , Humans , Retrospective Studies , Female , Male , Phacoemulsification/methods , Visual Acuity/physiology , Middle Aged , Aged , Laser Therapy/methods , Cataract/complications , Cataract/physiopathology , Tomography, Optical Coherence/methods , Macula Lutea/diagnostic imaging , Macula Lutea/pathology , Cataract Extraction/methods , Myopia, Degenerative/physiopathology , Myopia, Degenerative/surgery , Myopia, Degenerative/complications , Choroid/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...