Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.895
Filter
1.
Lasers Med Sci ; 39(1): 154, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38862806

ABSTRACT

PURPOSE: To investigate the diagnostic ability of retinal superficial vasculature evaluation by optic coherence tomography angiography (OCTA) combined with visual field (VF) testing for early primary open-angle glaucoma (POAG). PATIENTS AND METHODS: In this cross-sectional study, 84 participants were included, including 11 in the ocular hypertension (OHT) group, 11 in the preperimetric POAG (pre-POAG) group, 29 in the early POAG group and 33 in the control group. All participants underwent 6 × 6 mm2 scans of macula and optic nerved head by optic coherence tomography (OCT) and OCTA, along with white-on-white and blue-on-yellow VF testing by static automated perimetry. The ability of diagnosing early glaucoma by either various examinations separately or combination of examinations in both terms of function and structure was studied using the receiver operating characteristic (ROC) curve and the area under the curve (AUC). RESULTS: The superficial retinal vessel densities (VD) in peri-nasal, para-temporal, peri-temporal and peri-inferior regions around the macula, as well as vessel area densities (VAD) in all peripapillary regions, were significantly different among the four groups, with lower VD or VAD in the early POAG patients compared to the normal individuals. The diagnostic ability of peripapillary superficial retinal VAD alone or VF testing alone was limited for early POAG only. However, the combination of these two was more effective in distinguishing normal individuals from OHT subjects or pre-POAG patients without VF defects, with better performance than the combination of peripapillary retinal nerve fiber layer (RNFL) thickness and VF indicators. CONCLUSIONS: Peripapillary retinal vessel densities were generally lower in early POAG patients compared to normal individuals. The combination of peripapillary superficial retinal VAD by OCTA with white-on-white VF testing improved the ability to distinguish POAG patients at early stage without function impairment, which may help in providing reference and guidance for the following-up and treatment of suspected POAG patients.


Subject(s)
Glaucoma, Open-Angle , Microvessels , Retinal Vessels , Tomography, Optical Coherence , Visual Field Tests , Humans , Glaucoma, Open-Angle/physiopathology , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/diagnostic imaging , Cross-Sectional Studies , Male , Middle Aged , Visual Field Tests/methods , Female , Tomography, Optical Coherence/methods , Microvessels/diagnostic imaging , Retinal Vessels/diagnostic imaging , Retinal Vessels/physiopathology , Aged , ROC Curve , Visual Fields/physiology , Adult , Optic Disk/blood supply , Optic Disk/diagnostic imaging , Early Diagnosis
2.
Transl Vis Sci Technol ; 13(6): 10, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38884547

ABSTRACT

Purpose: To explore the structural-functional loss relationship from optic-nerve-head- and macula-centred spectral-domain (SD) Optical Coherence Tomography (OCT) images in the full spectrum of glaucoma patients using deep-learning methods. Methods: A cohort comprising 5238 unique eyes classified as suspects or diagnosed with glaucoma was considered. All patients underwent ophthalmologic examination consisting of standard automated perimetry (SAP), macular OCT, and peri-papillary OCT on the same day. Deep learning models were trained to estimate G-pattern visual field (VF) mean deviation (MD) and cluster MD using retinal thickness maps from seven layers: retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer (GCL + IPL), inner nuclear layer and outer plexiform layer (INL + OPL), outer nuclear layer (ONL), photoreceptors and retinal pigmented epithelium (PR + RPE), choriocapillaris and choroidal stroma (CC + CS), total retinal thickness (RT). Results: The best performance on MD prediction is achieved by RNFL, GCL + IPL and RT layers, with R2 scores of 0.37, 0.33, and 0.31, respectively. Combining macular and peri-papillary scans outperforms single modality prediction, achieving an R2 value of 0.48. Cluster MD predictions show promising results, notably in central clusters, reaching an R2 of 0.56. Conclusions: The combination of multiple modalities, such as optic-nerve-head circular B-scans and retinal thickness maps from macular SD-OCT images, improves the performance of MD and cluster MD prediction. Our proposed model demonstrates the highest level of accuracy in predicting MD in the early-to-mid stages of glaucoma. Translational Relevance: Objective measures recorded with SD-OCT can optimize the number of visual field tests and improve individualized glaucoma care by adjusting VF testing frequency based on deep-learning estimates of functional damage.


Subject(s)
Deep Learning , Macula Lutea , Tomography, Optical Coherence , Visual Fields , Tomography, Optical Coherence/methods , Humans , Female , Middle Aged , Male , Visual Fields/physiology , Macula Lutea/diagnostic imaging , Macula Lutea/pathology , Prognosis , Aged , Retinal Ganglion Cells/pathology , Glaucoma/diagnostic imaging , Glaucoma/pathology , Nerve Fibers/pathology , Visual Field Tests/methods , Optic Disk/diagnostic imaging , Optic Disk/pathology
3.
Transl Vis Sci Technol ; 13(6): 14, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38899952

ABSTRACT

Purpose: The VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field. We examined same-day and 3-month repeatability. Methods: Adult participants with a diagnosis of glaucoma or ocular hypertension underwent two VisuALL 24-2 Normal T- Full threshold strategy tests at baseline and one additional exam at 3 months for each eligible eye. Spearman, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to assess the correlation of individual point sensitivities and mean deviation (MD) among three tests. Results: Eighty-eight eyes (44 participants) were included. Average age was 68.1 ± 14.3 years, and 60.7% were male. VisuALL MD was highly correlated between tests (intravisit: r = 0.89, intervisit: r = 0.82; P < 0.001 for both). Bland-Altman analysis showed an average difference in intravisit MD of -0.67 dB (95% confidence interval [CI], -6.04 to 4.71 dB) and -0.15 dB (95% CI, -8.04 to 7.73 dB) for intervisit exams. Eight-five percent of pointwise intravisit ICCs were above 0.75 (range, 0.63 to 0.93), and 65% of pointwise intervisit ICCs were above 0.75 (range, 0.55 to 0.91). Conclusions: VisuALL demonstrated high correlation of MD between tests and good repeatability for individual point sensitivities among three tests in 3 months, except at the points around the blind spot and superiorly. Translational Relevance: The preliminary reproducibility results for VisuALL are encouraging. Its portable design makes it a potentially useful tool for patients with glaucoma, enabling more frequent assessments both at home and in clinical settings.


Subject(s)
Glaucoma , Ocular Hypertension , Virtual Reality , Visual Field Tests , Visual Fields , Humans , Male , Ocular Hypertension/diagnosis , Ocular Hypertension/physiopathology , Female , Aged , Reproducibility of Results , Middle Aged , Visual Field Tests/methods , Visual Field Tests/instrumentation , Glaucoma/diagnosis , Visual Fields/physiology , Aged, 80 and over , Intraocular Pressure/physiology , Prospective Studies
4.
Transl Vis Sci Technol ; 13(6): 19, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38916881

ABSTRACT

Purpose: We sought to develop and evaluate a practical framework that supports structurally enhanced perimetric examinations. Methods: Two perimetric strategies were compared: standard Zippy Estimation through Sequential Testing (ZEST) procedure, a traditional visual field test with population-based prior distributions, and structural-ZEST (S-ZEST), enhanced with individual optical coherence tomography data to determine the starting parameters. The integration and collection of data was facilitated by a bespoke application developed in Shiny R (R Studio). The test was implemented using the Open Perimetry Interface on the Compass perimeter (CentreVue-iCare, Italy). The strategies were evaluated via simulations and on 10 visually healthy participants. The usability of the application was assessed in a simulated environment with 10 test users. Results: In simulations, the S-ZEST improved test speed in patients with glaucoma. In the practical implementation, there was a statistically significant decrease in the testing time (approximately 26%) and in the number of presentations per test with S-ZEST (P < 0.001). The structure-function relationship was similar between the two strategies. The time taken for users to complete the sequence of actions on the application was 52.9 ± 11.5 seconds (mean ± standard deviation). Conclusions: Structurally enhanced perimetric examination can significantly improve test time in healthy subjects and can be delivered through a user-friendly interface. Further testing will need to assess feasibility and performance of S-ZEST in patients with glaucoma. Translational Relevance: We have developed a user-friendly web application based within the Shiny environment for R, which implements an automated extraction of optical coherence tomography data from raw files and performs real-time calculations of structural features to inform the perimetric strategy.


Subject(s)
Tomography, Optical Coherence , Visual Field Tests , Visual Fields , Humans , Tomography, Optical Coherence/methods , Visual Field Tests/methods , Male , Female , Visual Fields/physiology , Middle Aged , Adult , Glaucoma/diagnosis , Aged , Healthy Volunteers
5.
Invest Ophthalmol Vis Sci ; 65(6): 35, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38916884

ABSTRACT

Purpose: To investigate the characteristics of microperimetry and optical coherence tomography (OCT) in congenital stationary night blindness (CSNB), as well as their structure-function association. Methods: This cross-sectional study included 32 eyes from 32 participants with CSNB, comprising 18 with complete CSNB and 14 with incomplete CSNB, along with 36 eyes from 36 CSNB-unaffected controls matched for age, sex, and spherical equivalent. Using MP-3 microperimetry, central retinal sensitivity was assessed within a 20° field, distributed across six concentric rings (0°, 2°, 4°, 6°, 8°, and 10°). OCT was used to analyze retinal and choroidal thickness. The study aimed to assess the overall and ring-wise retinal sensitivity, as well as choroidal and retinal thickness in CSNB and CSNB-unaffected controls, with a secondary focus on the relationship between retinal sensitivity and microstructural features on OCT. Results: In comparison with CSNB-unaffected subjects, the overall and ring-wise retinal sensitivity as well as choroidal thickness were reduced in patients with CSNB (P < 0.001). Moreover, the central sensitivity in incomplete CSNB group was lower than in complete CSNB group (25.72 ± 3.93 dB vs. 21.92 ± 4.10 dB; P < 0.001). The retinal thickness in the CSNB group was thinner outside the fovea compared with the CSNB-unaffected group. Multiple mixed regression analyses revealed that point-to-point retinal sensitivity was significantly correlated with BCVA (P = 0.002) and the corresponding retinal thickness (P = 0.004). Conclusions: Examination of retinal sensitivity and OCT revealed different spatial distribution profiles in CSNB and its subtypes. In CSNB eyes, retinal sensitivity on microperimetry was associated with retinal thickness on OCT.


Subject(s)
Genetic Diseases, X-Linked , Myopia , Night Blindness , Retina , Tomography, Optical Coherence , Visual Field Tests , Visual Fields , Humans , Tomography, Optical Coherence/methods , Female , Male , Cross-Sectional Studies , Night Blindness/physiopathology , Night Blindness/diagnosis , Visual Field Tests/methods , Visual Fields/physiology , Genetic Diseases, X-Linked/physiopathology , Retina/physiopathology , Retina/diagnostic imaging , Adult , Myopia/physiopathology , Myopia/diagnosis , Young Adult , Eye Diseases, Hereditary/physiopathology , Eye Diseases, Hereditary/diagnosis , Visual Acuity/physiology , Adolescent , Myopia, Degenerative/physiopathology , Myopia, Degenerative/complications , Myopia, Degenerative/diagnosis , Child , Choroid/pathology , Choroid/diagnostic imaging , Choroid/physiopathology
6.
J AAPOS ; 28(3): 103933, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38729256

ABSTRACT

PURPOSE: To assess the feasibility and performance of Vivid Vision Perimetry (VVP), a new virtual reality (VR)-based visual field platform. METHODS: Children 7-18 years of age with visual acuity of 20/80 or better undergoing Humphrey visual field (HVF) testing were recruited to perform VVP, a VR-based test that uses suprathreshold stimuli to test 54 field locations and calculates a fraction seen score. Pearson correlation coefficients were calculated to evaluate correlation between HVF mean sensitivity and VVP mean fraction seen scores. Participants were surveyed regarding their experience. RESULTS: A total of 37 eyes of 23 participants (average age, 12.9 ± 3.1 years; 48% female) were included. All participants successfully completed VVP testing. Diagnoses included glaucoma (12), glaucoma suspect (7), steroid-induced ocular hypertension (3), and craniopharyngioma (1). Sixteen participants had prior HVF experience, and none had prior VVP experience, although 7 had previously used VR. Of the 23 HVF tests performed, 9 (39%) were unreliable due to fixation losses, false positives, or false negatives. Similarly, 35% of VVP tests were unreliable (as defined by accuracy of blind spot detection). Excluding unreliable HVF tests, the correlation between HVF average mean sensitivity and VVP mean fraction seen score was 0.48 (P = 0.02; 95% CI, 0.09-0.74). When asked about preference for the VVP or HVF examination, all participants favored the VVP, and 70% were "very satisfied" with VVP. CONCLUSIONS: In our cohort of 23 pediatric subjects, VVP proved to be a clinically feasible VR-based visual field testing, which was uniformly preferred over HVF.


Subject(s)
Feasibility Studies , Virtual Reality , Visual Acuity , Visual Field Tests , Visual Fields , Humans , Visual Field Tests/methods , Child , Female , Male , Pilot Projects , Adolescent , Visual Fields/physiology , Visual Acuity/physiology , Glaucoma/diagnosis , Glaucoma/physiopathology , Reproducibility of Results , Vision Disorders/diagnosis , Vision Disorders/physiopathology , Ocular Hypertension/diagnosis , Ocular Hypertension/physiopathology
7.
Sci Rep ; 14(1): 12524, 2024 05 31.
Article in English | MEDLINE | ID: mdl-38822030

ABSTRACT

Aim of this study was to explore the optimal training interval and times of microperimetric biofeedback training (MBFT) in maculopathies. Twenty-nine patients with maculopathies were divided into two groups: daily training (Group A) or alternate daily training (Group B). Both groups underwent 15 MBFT sessions. We compared the BCVA, reading speed, and fixation stability at baseline, after 5, 10, 15 sessions. After 15 sessions of MBFT, all visual parameters in both groups improved. There was a significant increase in BCVA after 5 sessions in both groups (P=0.016, and P<0.001 respectively), but Group A showed further improvement after 10 sessions (P<0.001). Regarding reading speed, Group A showed significant improvement from baseline after 15 sessions(P=0.020), Group B improved significantly after 5 sessions (P=0.047) and continued to improve after 10 sessions (P=0.030). Additionally, P1 and LgBCEA of Group A significantly improved after 10 sessions (P=0.001, and P=0.001 respectively), while Group B significantly improved after 5 sessions (P=0.002, and P<0.001 respectively). There was no significant difference in visual outcomes between the two groups (P>0.05) except LgBCEA (P=0.046) after 15 sessions. We concluded that the both MBFT frequencies are effective at improving vision and quality of life in patients with maculopathies. The alternate daily training group showed less time-dependent of improvement in all parameters and a greater benefit in fixation stability. Ten sessions are the optimal number of treatment sessions for alternate daily training.


Subject(s)
Biofeedback, Psychology , Humans , Female , Male , Biofeedback, Psychology/methods , Middle Aged , Aged , Visual Acuity/physiology , Time Factors , Visual Field Tests/methods , Treatment Outcome , Adult
8.
Vestn Oftalmol ; 140(2): 14-23, 2024.
Article in Russian | MEDLINE | ID: mdl-38742494

ABSTRACT

PURPOSE: This article studies the relationship between structural changes according to the findings of optical coherence tomography (OCT) and OCT angiography (OCTA), microperimetry (MP), multifocal electroretinography (mfERG) parameters in topographically corresponding areas of the macular region in idiopathic full-thickness macular holes (FTMH). MATERIAL AND METHODS: OCT, OCTA, MP and mfERG were performed in 14 eyes with FTMH stages I-IV according to Gass. In 13 points at a distance of 0-2.5°, 2.5-5.0°, and 5.0-10.0° from the fixation point, the light sensitivity (LS), amplitude and latency of the P1 component were compared with the size of the hole, the area of cystic changes (CC) at the level of the inner nuclear layer (INL) and the outer plexiform layer and Henle fiber layer complex (OPL+HFL), vessel density in the superficial and deep capillary plexus (SCP and DCP). RESULTS: LS and P1 component amplitude were significantly reduced at a distance of up to 5.0° from the fixation point. LS correlates with the apical and basal diameter of the hole (R> -0.53), the area of CC in the INL (R> -0.62) and the OPL+HFL complex (R> -0.55), the density of vessels in the SCP at a distance of up to 2.5° from the fixation point (R>0.51) and in the DCP at a distance of up to 5° from the fixation point (R>0.49). The P1 amplitude correlates with the basal diameter of the hole (R= -0.38), the area of CC in the INL and the OPL+HFL complex (R> -0.33) and vessel density in the SCP (R=0.37) at a distance of up to 2.5° from the fixation point, as well as vessel density in the DCP at a distance of up to 5° from the fixation point (R=0.47). Vessel density in the DCP is significantly lower in the presence of CC in the retina (p<0.001). CONCLUSION: In FTMH, there is a relationship between bioelectrical activity and LS, and structural disorders, capillary perfusion in different layers of the retina. A multimodal topographically oriented approach allows studying the relationship between structural and functional parameters in individual points of the retina and can be used in monitoring of FTMH after surgical treatment.


Subject(s)
Electroretinography , Retinal Perforations , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Retinal Perforations/physiopathology , Retinal Perforations/diagnosis , Female , Male , Electroretinography/methods , Middle Aged , Aged , Macula Lutea/diagnostic imaging , Macula Lutea/blood supply , Visual Field Tests/methods , Fluorescein Angiography/methods , Multimodal Imaging/methods
9.
Vestn Oftalmol ; 140(2. Vyp. 2): 34-42, 2024.
Article in Russian | MEDLINE | ID: mdl-38739129

ABSTRACT

PURPOSE: This study analyzes changes in light sensitivity in each test point of the visual field in patients with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study were analyzed. All patients underwent assessment of retinal light sensitivity and its variability in 54 points corresponding to the 24-2 program. Mean light sensitivity values were calculated in each point. Intergroup analysis was performed to evaluate changes in light sensitivity in each point. RESULTS: The range of light sensitivity decrease in the early glaucoma group compared to the control group was from 1.5 to 3.6 dB. The range of light sensitivity decrease in the moderate glaucoma group compared to the control group was from 2.1 to 11.5 dB, and compared to the early glaucoma group - from -0.9 to 7.9 dB. The most frequent decrease in light sensitivity was detected in the nasal sector and along the horizontal line in the upper half of the visual field. This trend persisted within the central 10 degrees of the visual field. The range of light sensitivity decrease in the advanced glaucoma group compared to the control group was from 14.1 to 28.0 dB, and compared to the early glaucoma group - from 11.35 to 26.08 dB, compared to the moderate glaucoma group - from 9.1 to 23.5 dB. The most frequent and severe decrease in light sensitivity was detected in the paracentral zone in the lower half of the visual field. CONCLUSION: The study analyzed the trends in the development of glaucoma from the early to the advanced stage. The most frequent and severe defect in light sensitivity in cases of verified advanced glaucoma was found in the lower half of the visual field. Points No. 32, 33 and 40 can be indicated as the area of interest in assessing the progression of glaucoma, as they were found to have the most profound changes in light sensitivity as glaucoma progressed.


Subject(s)
Disease Progression , Glaucoma , Visual Field Tests , Visual Fields , Humans , Visual Fields/physiology , Glaucoma/physiopathology , Glaucoma/diagnosis , Male , Female , Middle Aged , Visual Field Tests/methods , Prospective Studies , Aged , Case-Control Studies , Light
10.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Article in Russian | MEDLINE | ID: mdl-38739140

ABSTRACT

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Subject(s)
Glaucoma , Retina , Visual Field Tests , Visual Fields , Humans , Visual Fields/physiology , Visual Field Tests/methods , Glaucoma/physiopathology , Glaucoma/diagnosis , Middle Aged , Male , Female , Retina/physiopathology , Prospective Studies , Adult , Light , Aged , Sensory Thresholds/physiology , Case-Control Studies , Reproducibility of Results
11.
Retina ; 44(6): 982-990, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38767849

ABSTRACT

PURPOSE: To evaluate macular sensitivity using microperimetry in patients with proliferate diabetic retinopathy following vitrectomy and to investigate the relationship between the sensitivity and foveal microstructures with optical coherence tomography/angiography. METHODS: Eighty-four eyes of 84 patients with proliferative diabetic retinopathy, who were indicated for vitrectomy, had no intraocular surgery history 3 months preoperatively, and were able to ensure fundus examination after the vitrectomy, were included. A logMAR best-corrected visual acuity, macular sensitivity of microperimetry, macular retinal thickness, and macular vessel perfusion using optical coherence tomography/angiography were examined at 1 week, 1 month, and 3 months postoperatively. RESULTS: The logMAR best-corrected visual acuity and mean macular sensitivity of patients with proliferative diabetic retinopathy improved postoperatively (P < 0.05). There was a significant correlation between best-corrected visual acuity and mean sensitivity (P < 0.05). Postoperative mean macular sensitivity was significantly correlated with outer retinal thickness in the 0 to 6 mm macular area (P < 0.05) and also significantly correlated with deep capillary plexus perfusion (P < 0.05). Fixation stability and mean macular sensitivity did not show any correlation with glycated hemoglobin, triglyceride, serum total cholesterol, carbamide, and creatinine and duration of diabetes mellitus (P > 0.05). CONCLUSION: Postoperative mean macular sensitivity was significantly correlated with outer retinal thickness and deep capillary plexus perfusion for patients with proliferative diabetic retinopathy. The authors found that the visual performance of patients can be evaluated by the outer retinal thickness and deep capillary plexus perfusion, so optical coherence tomography/angiography examination can be an important prognostic factor for visual performance in patients.Clinical Trial Registration: This trial is registered with the Chinese Clinical Trial Registry (http://www.chictr.org.cn; Registration No.: ChiCTR2100043399).


Subject(s)
Diabetic Retinopathy , Fluorescein Angiography , Macula Lutea , Tomography, Optical Coherence , Visual Acuity , Visual Field Tests , Vitrectomy , Humans , Diabetic Retinopathy/physiopathology , Diabetic Retinopathy/surgery , Diabetic Retinopathy/diagnosis , Vitrectomy/methods , Male , Female , Tomography, Optical Coherence/methods , Visual Acuity/physiology , Middle Aged , Visual Field Tests/methods , Fluorescein Angiography/methods , Macula Lutea/blood supply , Macula Lutea/diagnostic imaging , Aged , Adult , Visual Fields/physiology , Retinal Vessels/physiopathology , Retinal Vessels/diagnostic imaging , Postoperative Period
12.
Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38743410

ABSTRACT

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Subject(s)
Computers, Handheld , Glaucoma , Visual Field Tests , Visual Fields , Humans , Child , Visual Fields/physiology , Visual Field Tests/methods , Visual Field Tests/instrumentation , Male , Female , Adolescent , Glaucoma/diagnosis , Glaucoma/physiopathology , Reproducibility of Results
13.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38743409

ABSTRACT

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Subject(s)
Glaucoma , Nerve Fibers , Retinal Ganglion Cells , Tomography, Optical Coherence , Visual Fields , Humans , Tomography, Optical Coherence/methods , Cross-Sectional Studies , Male , Female , Middle Aged , Nerve Fibers/pathology , Pilot Projects , Visual Fields/physiology , Glaucoma/physiopathology , Glaucoma/diagnostic imaging , Aged , Retinal Ganglion Cells/pathology , ROC Curve , Visual Field Tests/methods , Adult , Intraocular Pressure/physiology
14.
PLoS One ; 19(5): e0303849, 2024.
Article in English | MEDLINE | ID: mdl-38768185

ABSTRACT

PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises. METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation. RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively. CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.


Subject(s)
Computer Graphics , Glaucoma , Visual Fields , Humans , Glaucoma/physiopathology , Visual Fields/physiology , Female , Male , Middle Aged , Aged , Visual Field Tests/methods , Adult , Visual Perception/physiology
15.
J Glaucoma ; 33(7): 505-515, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38595156

ABSTRACT

PRCIS: Online circular contrast perimetry provides visual field assessment on any computer or tablet with no extra hardware. It has good test repeatability and reliability that is comparable with standard automated perimetry. It holds promise for use in disease screening and surveillance to expand the provision of glaucoma care. PURPOSE: To evaluate the repeatability of online circular contrast perimetry (OCCP) compared to standard automated perimetry (SAP) in normal participants and patients with stable glaucoma over 18 weeks. METHODS: Thirty-six participants (13 normal controls and 23 patients with open angle glaucoma) were recruited. OCCP and SAP perimetry tests were performed twice at baseline, then at 6, 12, and 18 weeks. Global perimetric indices were compared between perimetry types and analyzed for short-term and intermediate-term repeatability. RESULTS: There were no statistically significant changes over time for both OCCP and SAP across all groups for mean deviation (MD), pattern standard deviation, and visual index/visual field index ( P >0.05). Test-retest intraclass correlation coefficients (ICCs) for OCCP MD were excellent at baseline (0.98, 95% CI: 0.89-0.99) and good at 18 weeks (0.88, 95% CI: 0.51-0.98). SAP test-retest ICCs were excellent at baseline (0.94, 95% CI: 0.70-0.99) and 18 weeks (0.97, 95% CI: 0.84-0.99). Inter-test ICCs were good, ranging from 0.84 to 0.87. OCCP testing time was shorter than SAP (5:29 ± 1:24 vs. 6:00 ± 1:05, P <0.001). OCCP had similar false-positive (3.84 ± 3.32 vs. 3.66 ± 4.53, P =0.48) but lower false-negative (0.73 ± 1.52 vs. 4.48 ± 5.00, P <0.001) and fixation loss responses (0.91 ± 1.32 vs. 2.02 ± 2.17, P <0.001). CONCLUSIONS: OCCP allows visual field assessment on any computer screen with no additional hardware. It demonstrated good repeatability and reliability with similar performance indices to SAP in both the short term and intermediate term. OCCP has the potential to be utilized as a glaucoma screening and surveillance tool for in-clinic and at-home testing, expanding the provision of care.


Subject(s)
Glaucoma, Open-Angle , Intraocular Pressure , Vision Disorders , Visual Field Tests , Visual Fields , Humans , Visual Field Tests/methods , Reproducibility of Results , Visual Fields/physiology , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/physiopathology , Female , Male , Middle Aged , Aged , Vision Disorders/diagnosis , Vision Disorders/physiopathology , Intraocular Pressure/physiology , Adult
16.
BMC Ophthalmol ; 24(1): 159, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600474

ABSTRACT

BACKGROUND: Multifocal pupillographic objective perimetry (mfPOP) is a novel method for assessing functional change in diseases like glaucoma. Previous research has suggested that, in contrast to the pretectally-mediated melanopsin response of intrinsically photosensitive retinal ganglion cells, mfPOP responses to transient onset stimuli involve the extrastriate cortex, and thus the main visual pathway. We therefore investigate the correlation between peripapillary retinal nerve fibre layer (pRNFL) thickness and glaucomatous visual field changes detected using mfPOP. Parallel analyses are undertaken using white on white standard automated perimetry (SAP) for comparison. METHODS: Twenty-five glaucoma patients and 24 normal subjects were tested using SAP, 3 mfPOP variants, and optical coherence tomography (OCT). Arcuate clusters of the SAP and mfPOP deviations were weighted according to their contribution to published arcuate divisions of the retinal nerve fibre layer. Structure-function correlation coefficients (r) were computed between pRNFL clock-hour sector thickness measurements, and the local visual field sensitivities from both SAP and mfPOP. RESULTS: The strongest correlation was observed in the superior-superotemporal disc sector in patients with worst eye SAP MD < -12 dB: r = 0.93 for the mfPOP LumBal test (p < 0.001). Correlations across all disc-sectors were strongest in these same patients in both SAP and mfPOP: SAP r = 0.54, mfPOP LumBal r = 0.55 (p < 0.001). In patients with SAP MD ≥ -6 dB in both eyes, SAP correlations across all sectors were higher than mfPOP; mfPOP correlations however, were higher than SAP in more advanced disease, and in normal subjects. CONCLUSIONS: For both methods the largest correlations with pRNFL thickness corresponded to the inferior nasal field of more severely damaged eyes. Head-to-head comparison of mfPOP and SAP showed similar structure-function relationships. This agrees with our recent reports that mfPOP primarily stimulates the cortical drive to the pupils.


Subject(s)
Glaucoma , Visual Field Tests , Humans , Visual Field Tests/methods , Retina , Tomography, Optical Coherence/methods , Nerve Fibers , Structure-Activity Relationship
17.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38643220

ABSTRACT

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Subject(s)
Glaucoma , Visual Fields , Humans , Reproducibility of Results , Glaucoma/diagnosis , Visual Field Tests/methods , Vision Disorders/diagnosis , Sensitivity and Specificity
18.
PLoS One ; 19(4): e0301419, 2024.
Article in English | MEDLINE | ID: mdl-38573981

ABSTRACT

Perimetry, or visual field test, estimates differential light sensitivity thresholds across many locations in the visual field (e.g., 54 locations in the 24-2 grid). Recent developments have shown that an entire visual field may be relatively accurately reconstructed from measurements of a subset of these locations using a linear regression model. Here, we show that incorporating a dimensionality reduction layer can improve the robustness of this reconstruction. Specifically, we propose to use principal component analysis to transform the training dataset to a lower dimensional representation and then use this representation to reconstruct the visual field. We named our new reconstruction method the transformed-target principal component regression (TTPCR). When trained on a large dataset, our new method yielded results comparable with the original linear regression method, demonstrating that there is no underfitting associated with parameter reduction. However, when trained on a small dataset, our new method used on average 22% fewer trials to reach the same error. Our results suggest that dimensionality reduction techniques can improve the robustness of visual field testing reconstruction algorithms.


Subject(s)
Visual Field Tests , Visual Fields , Visual Field Tests/methods , Sensory Thresholds , Algorithms , Regression Analysis
19.
Arch. Soc. Esp. Oftalmol ; 99(3): 91-97, Mar. 2024. tab, ilus
Article in Spanish | IBECS | ID: ibc-231135

ABSTRACT

Detectar y caracterizar los defectos del campo visual (CV) mediante perimetría Octopus en pacientes con glaucoma congénito primario (GCP) y determinar la calidad y duración del CV. Material y métodos: Se incluyeron 88 ojos de 70 pacientes diagnosticados de GCP. Las evaluaciones se realizaron con un Octopus 900 y cada ojo se evaluó con el algoritmo de perimetría orientada por tendencias (G-TOP). Se recogieron datos cuantitativos de CV: datos de calidad (respuestas falsa positiva y negativa, y duración del tiempo) y resultados de desviación media (DM) y raíz cuadrada de la varianza de pérdida (sLV). También se recogieron datos cualitativos: presencia de defectos difusos y localizados, hemicampo afectado y grado de defectos utilizando la clasificación de Aulhorn y Karmeyer. Se analizaron las correlaciones entre los resultados perimétricos y las variables clínicas. Resultados: La mediana de edad fue de 11 (8-17) años. El 65,9% (58/88) de los ojos con GCP presentaban defectos de CV. Se observaron defectos difusos en 10/58 ojos (16,94%) (DM media=23,92 [DE: 2,52]) dB) y defectos localizados en 48/58 ojos (82,75%). El defecto más frecuente fue el escotoma incipiente paracentral (n=15), el escalón nasal (n=8), el defecto arciforme añadido (n=2), el semianular (n=13) y el defecto concéntrico con isla central (n=9). El hemicampo visual afectado con mayor frecuencia fue el inferior. La duración media de la prueba fue de 2min 12s (DE: 21,6s). Los valores MD y sLV se correlacionaron con la agudeza visual mejor corregida, la relación excavación/disco y el número de cirugías de glaucoma (todas p<0,001). Conclusión: Se identificó un alto número de defectos difusos y localizados utilizando la perimetría Octopus en pacientes con GCP. El defecto más frecuente fue el escotoma paracentral, y el hemicampo inferior fue el más afectado.(AU)


Purpose: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. Material and methods: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. ResultsMedian age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD=23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n=15), nasal step (n=8), adding arcuate defect (n=2), half ring-shaped (n=13) and concentric defect with a central island (n=9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2min 12s (SD: 21.6s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P<.001). Conclusion: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.(AU)


Subject(s)
Humans , Male , Female , Child , Glaucoma , Visual Field Tests/methods , Blindness , Eye Abnormalities , Ophthalmology , Pediatrics , Vision, Ocular
20.
Transl Vis Sci Technol ; 13(3): 10, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38488433

ABSTRACT

Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.


Subject(s)
Glaucoma , Virtual Reality , Wearable Electronic Devices , Aged , United States , Adult , Humans , Visual Fields , Vision Disorders , Reproducibility of Results , Medicare , Glaucoma/diagnosis , Visual Field Tests/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...