Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 193
Filter
1.
Sci Rep ; 14(1): 12899, 2024 06 05.
Article in English | MEDLINE | ID: mdl-38839853

ABSTRACT

While volatile organic compounds (VOCs) impair various organs, their influence on hearing loss (HL) has not been extensively researched. We aimed to identify the association between VOCs and HL or high-frequency hearing loss (HFHL). We extracted data on age, sex, pure tone audiometry, hypertension, occupational noise exposure, and creatinine-corrected urine VOC metabolite concentrations from the eighth Korea National Health and Nutrition Survey. Among the VOC metabolites, N-acetyl-S-(benzyl)-L-cysteine (BMA, P = 0.004), N-acetyl-S-(phenyl)-L-cysteine (SPMA, P = 0.027), and N-acetyl-S-(3,4-dihydroxybutyl)-L-cysteine (DHBMA, P < 0.001) showed associations with HL. Additionally, HFHL exhibited significant associations with BMA (P = 0.005), 3- and 4-methylhippuric acid (3, 4 MHA, P = 0.049), mandelic acid (MA, P = 0.015), SPMA (P < 0.001), N-acetyl-S-(3-hydroxypropyl)-L-cysteine (3-HPMA, P < 0.001), and DHBMA (P < 0.001). After controlling other factors, DHBMA were associated with HL (P = 0.021) and HFHL (P = 0.014) and exhibited a linear association with the mean hearing level (ß = 0.054, P = 0.024) and high-frequency hearing level (ß = 0.045, P = 0.037). Since 1,3-butadiene may act as an ototoxic material, early screening for workers exposed to 1,3-butadiene and reducing exposure to 1,3-butadiene in everyday life may be helpful to prevent further HL.


Subject(s)
Butadienes , Hearing Loss , Volatile Organic Compounds , Humans , Female , Male , Middle Aged , Hearing Loss/chemically induced , Hearing Loss/etiology , Volatile Organic Compounds/urine , Volatile Organic Compounds/adverse effects , Republic of Korea/epidemiology , Adult , Occupational Exposure/adverse effects , Occupational Exposure/analysis , Aged , Nutrition Surveys , Audiometry, Pure-Tone
2.
Environ Health ; 23(1): 45, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702703

ABSTRACT

BACKGROUND: Volatile organic compounds (VOCs) encompass hundreds of high production volume chemicals and have been reported to be associated with adverse respiratory outcomes such as chronic obstructive pulmonary disease (COPD). However, research on the combined toxic effects of exposure to various VOCs on COPD is lacking. We aimed to assess the effect of VOC metabolite mixture on COPD risk in a large population sample. METHODS: We assessed the effect of VOC metabolite mixture on COPD risk in 5997 adults from the National Health and Nutrition Examination Survey (NHANES) from 2011 to 2020 (pre-pandemic) using multivariate logistic regression, Bayesian weighted quantile sum regression (BWQS), quantile-based g-Computation method (Qgcomp), and Bayesian kernel machine regression (BKMR). We explored whether these associations were mediated by white blood cell (WBC) count and total bilirubin. RESULTS: In the logistic regression model, we observed a significantly increased risk of COPD associated with 9 VOC metabolites. Conversely, N-acetyl-S-(benzyl)-L-cysteine (BMA) and N-acetyl-S-(n-propyl)-L-cysteine (BPMA) showed insignificant negative correlations with COPD risk. The overall mixture exposure demonstrated a significant positive relationship with COPD in both the BWQS model (adjusted odds ratio (OR) = 1.30, 95% confidence interval (CI): 1.06, 1.58) and BKMR model, and with marginal significance in the Qgcomp model (adjusted OR = 1.22, 95% CI: 0.98, 1.52). All three models indicated a significant effect of the VOC metabolite mixture on COPD in non-current smokers. WBC count mediated 7.1% of the VOC mixture associated-COPD in non-current smokers. CONCLUSIONS: Our findings provide novel evidence suggesting that VOCs may have adverse associations with COPD in the general population, with N, N- Dimethylformamide and 1,3-Butadiene contributing most. These findings underscore the significance of understanding the potential health risks associated with VOC mixture and emphasize the need for targeted interventions to mitigate the adverse effects on COPD risk.


Subject(s)
Nutrition Surveys , Pulmonary Disease, Chronic Obstructive , Volatile Organic Compounds , Humans , Pulmonary Disease, Chronic Obstructive/epidemiology , Pulmonary Disease, Chronic Obstructive/chemically induced , Volatile Organic Compounds/urine , Male , Middle Aged , Female , United States/epidemiology , Adult , Aged , Mediation Analysis , Air Pollutants/analysis , Logistic Models
3.
J Physiol Pharmacol ; 75(2): 215-222, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38736268

ABSTRACT

The analysis of volatile organic compounds (VOCs) present in various biological samples holds immense potential for non-invasive disease diagnostics and metabolic profiling. One of the biological fluids that are suitable for use in clinical practice is urine. Given the limited quantity of VOCs in the urine headspace, it's imperative to enhance their extraction into the gaseous phase and prevent any degradation of VOCs during the thawing process. The study aimed to test several key parameters (incubation time, temperature, and thawing) that can influence urine volatilome and monitor selected VOCs for their stability. The analysis in this study was performed using a BreathSpec® (G.A.S., Dortmund, Germany) device consisting of a gas chromatograph (GC) coupled with an ion mobility spectrometer (IMS). Testing three different temperatures and incubation times yielded a low number of VOCs (9 out of 34) that exhibited statistically significant differences. However, examining three thawing conditions revealed no VOCs with statistically significant changes. Thus, we conclude that urine composition remains relatively stable despite exposure to various thermal stresses.


Subject(s)
Ion Mobility Spectrometry , Volatile Organic Compounds , Volatile Organic Compounds/urine , Volatile Organic Compounds/analysis , Humans , Pilot Projects , Ion Mobility Spectrometry/methods , Male , Adult , Gas Chromatography-Mass Spectrometry/methods , Female , Temperature , Young Adult , Middle Aged
4.
World J Urol ; 42(1): 353, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38795133

ABSTRACT

PURPOSE: Despite many efforts, no reliable urinary marker system has so far shown the potential to substitute cystoscopy. Measuring volatile organic compounds (VOCs) from urine is a promising alternative. VOCs are metabolic products which can be measured from the headspace of urine samples. Previous studies confirmed that the urine of bladder tumor patients has a different VOC profile than healthy controls. In this pilot study, the feasibility of discriminating VOCs from urine of bladder cancer patients from that of healthy control subjects was investigated. Aim of this study was to investigate whether VOC-based diagnosis of bladder cancer from urine samples is feasible using multicapillary column ion mobility spectrometry (MCC/IMS) and to identify potential molecular correlates to the relevant analytes. METHODS: Headspace measurements of urine samples of 30 patients with confirmed transitional cell carcinoma (TCC) and 30 healthy controls were performed using MCC/IMS. In the results of the measurements, peaks showing significant differences between both groups were identified and implemented into a decision tree with respect to achieve group separation. Molecular correlates were predicted using a pre-defined dataset. RESULTS: Eight peaks with significantly differing intensity were identified, 5 of which were highly significant. Using a six-step decision tree, MCC/IMS showed a sensitivity of 90% and specificity of 100% in group separation. CONCLUSION: VOC-based detection of bladder cancer is feasible. MCC/IMS is a suitable method for urine-based diagnosis and should be further validated. The molecular characteristics and metabolic background of the analytes require further workup.


Subject(s)
Carcinoma, Transitional Cell , Ion Mobility Spectrometry , Urinary Bladder Neoplasms , Volatile Organic Compounds , Humans , Urinary Bladder Neoplasms/urine , Urinary Bladder Neoplasms/diagnosis , Volatile Organic Compounds/urine , Pilot Projects , Ion Mobility Spectrometry/methods , Male , Female , Aged , Middle Aged , Carcinoma, Transitional Cell/urine , Carcinoma, Transitional Cell/diagnosis , Feasibility Studies , Aged, 80 and over , Biomarkers, Tumor/urine
5.
Front Public Health ; 12: 1385628, 2024.
Article in English | MEDLINE | ID: mdl-38716244

ABSTRACT

Background: During the use of electronic cigarettes (e-cigarettes), users are still exposed to carcinogens similar to those found in tobacco products. Since these carcinogens are metabolized and excreted in urine, they may have carcinogenic effects on the bladder urinary tract epithelium. This meta-analysis aimed to compare bladder cancer carcinogens in the urine of tobacco users and e-cigarette users using a large number of samples. Methods: A systematic meta-analysis was performed using data obtained from several scientific databases (up to November 2023). This cumulative analysis was performed following the Preferred Reporting Items for Systematic Evaluation and Meta-Analysis (PRISMA) and Assessing the Methodological Quality of Systematic Evaluations (AMSTAR) guidelines, according to a protocol registered with PROSPERO. This study was registered on PROSPERO and obtained the unique number: CRD42023455600. Results: The analysis included 10 high-quality studies that considered polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs) and tobacco-specific nitrosamines (TSNAs). Statistical indicators show that there is a difference between the tobacco user group and the e-cigarette user group in terms of 1-Hydroxynaphthalene (1-NAP) [weighted mean difference (WMD)10.14, 95% confidence interval (CI) (8.41 to 11.88), p < 0.05], 1-Hydroxyphenanthrene (1-PHE) [WMD 0.08, 95% CI (-0.14 to 0.31), p > 0.05], 1-Hydroxypyrene (1-PYR) [WMD 0.16, 95% CI (0.12 to 0.20), p < 0.05], 2-Hydroxyfluorene (2-FLU) [WMD 0.69, 95% CI (0.58 to 0.80), p < 0.05], 2-Hydroxynaphthalene (2-NAP) [WMD 7.48, 95% CI (4.15 to 10.80), p < 0.05], 3-Hydroxyfluorene (3-FLU) [WMD 0.57, 95% CI (0.48 to 0.66), p < 0.05], 2-Carbamoylethylmercapturic acid (AAMA) [WMD 66.47, 95% CI (27.49 to 105.46), p < 0.05], 4-Hydroxy-2-buten-1-yl-mercapturic acid (MHBMA) [WMD 287.79, 95% CI (-54.47 to 630.04), p > 0.05], 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNAL) [WMD 189.37, 95% CI (78.45 to 300.29), p < 0.05], or N0-nitrosonornicotine (NNN) [WMD 11.66, 95% CI (7.32 to 16.00), p < 0.05]. Conclusion: Urinary bladder cancer markers were significantly higher in traditional tobacco users than in e-cigarette users.Systematic review registration: PROSPERO (CRD42023455600: https://www.crd.york.ac.uk/PROSPERO/).


Subject(s)
Urinary Bladder Neoplasms , Humans , Urinary Bladder Neoplasms/urine , Electronic Nicotine Delivery Systems/statistics & numerical data , Carcinogens/analysis , Volatile Organic Compounds/urine , Carcinogenesis , Polycyclic Aromatic Hydrocarbons/urine , Biomarkers/urine , Nitrosamines/urine , Tobacco Products
6.
J Chromatogr A ; 1722: 464863, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38626538

ABSTRACT

Volatile organic compounds (VOCs) are a group of ubiquitous environment pollutants especially released into the workplace. Assessment of VOCs exposure in occupational populations is therefore a crucial issue for occupational health. However, simultaneous biomonitoring of a variety of VOCs is less studied. In this study, a simple and sensitive method was developed for the simultaneous determination of 51 prototype VOCs in urine by headspace-thermal desorption coupled to gas chromatography-mass spectrometry (HS-TD-GC-MS). The urinary sample was pretreated with only adding 0.50 g of sodium chloride to 2 mL of urine and 51 VOCs should be determined with limits of detection (LODs) between 13.6 ng/L and 24.5 ng/L. The method linearity ranged from 0.005 to 10 µg/L with correlation coefficients (r) of 0.991 to 0.999. The precision for intraday and inter-day, measured by the variation coefficient (CV) at three levels of concentration, was below 15 %, except for 4-isopropyl toluene, dichloromethane, and trichloromethane at low concentration. For medium and high levels, recoveries of all target VOCs were within the standard range, but 1,1-dichloropropene and styrene, which were slightly under 80 % at low levels. In addition, the proposed method has been used to determine urine samples collected in three times (before, during and after working) from 152 workers at four different factories. 41 types of prototype VOCs were detected in workers urine. Significant differences (Kruskal-Wallis chi-squared = 117.18, df = 1, P < 0.05) in the concentration levels of VOCs between the exposed and unexposed groups were observed, but not between the three sampling times (Kruskal-Wallis chi-squared = 3.39, df = 2, P = 0.183). The present study provides an alternative method for biomonitoring and assessing mixed exposures to VOCs in occupational populations.


Subject(s)
Gas Chromatography-Mass Spectrometry , Limit of Detection , Occupational Exposure , Volatile Organic Compounds , Humans , Volatile Organic Compounds/urine , Gas Chromatography-Mass Spectrometry/methods , Occupational Exposure/analysis , Reproducibility of Results , Adult , Biological Monitoring/methods , Male
7.
Int J Hyg Environ Health ; 259: 114381, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38652941

ABSTRACT

Health risks to humans after "fume and smell events", short-term incidents on aircrafts that are accompanied by unpleasant odour or visible smoke, remain a subject of controversy. We assessed exposure to volatile organic compounds (VOC) and organophosphorus compounds (OPC) by biomonitoring in 375 aircrew members after self-reported "fume and smell events" and in 88 persons of the general population. A total of 20 parameters were analysed in blood and urine by gas chromatography and mass spectrometry. Median levels of acetone in blood and urine and 2-propanol in blood were elevated in aircrews compared to controls (p < 0.0001). Additionally, elevated peak exposures, best estimated by the 95th percentiles, were observed in aircrews for n-heptane and n-octane in blood, and acetone, 2,5-hexanedione and o-cresol in urine. Only the maximum observed levels of 2,5-hexandione in urine (768 µg/L) and toluene in blood (77 µg/L) in aircrew members were higher than the current biological exposure indices (BEI® levels) (500 and 20 µg/L, respectively) of the American Conference of Governmental Industrial Hygienists (US-ACGIH) for workers occupationally exposed to n-hexane and toluene, two well-accepted human neurotoxicants. Low-level exposures to n-hexane and toluene could be also observed in controls. The majority of OPC parameters in urine, including those of neurotoxic ortho-isomers of tricresylphosphate, were below the limit of quantitation in both aircrews and controls. Our comparative VOC and OPC analyses in biological samples of a large number of aircrew members and controls suggest that exposures are similar in both groups and generally low.


Subject(s)
Biological Monitoring , Flame Retardants , Occupational Exposure , Organophosphorus Compounds , Volatile Organic Compounds , Humans , Volatile Organic Compounds/urine , Volatile Organic Compounds/blood , Flame Retardants/analysis , Adult , Organophosphorus Compounds/urine , Organophosphorus Compounds/blood , Male , Occupational Exposure/analysis , Female , Middle Aged , Aircraft , Air Pollutants, Occupational/analysis , Air Pollutants, Occupational/urine , Acetone/urine , Acetone/blood , Acetone/analysis , Environmental Monitoring/methods , Young Adult , Toluene/analysis
8.
Prostate ; 84(8): 756-762, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38497426

ABSTRACT

BACKGROUND: Many diseases leave behind specific metabolites which can be detected from breath and urine as volatile organic compounds (VOC). Our group previously described VOC-based methods for the detection of bladder cancer and urinary tract infections. This study investigated whether prostate cancer can be diagnosed from VOCs in urine headspace. METHODS: For this pilot study, mid-stream urine samples were collected from 56 patients with histologically confirmed prostate cancer. A control group was formed with 53 healthy male volunteers matched for age who had recently undergone a negative screening by prostate-specific antigen (PSA) and digital rectal exam. Headspace measurements were performed with the electronic nose Cyranose 320TM. Statistical comparison was performed using principal component analysis, calculating Mahalanobis distance, and linear discriminant analysis. Further measurements were carried out with ion mobility spectrometry (IMS) to compare detection accuracy and to identify potential individual analytes. Bonferroni correction was applied for multiple testing. RESULTS: The electronic nose yielded a sensitivity of 77% and specificity of 62%. Mahalanobis distance was 0.964, which is indicative of limited group separation. IMS identified a total of 38 individual analytical peaks, two of which showed significant differences between groups (p < 0.05). To discriminate between tumor and controls, a decision tree with nine steps was generated. This model led to a sensitivity of 98% and specificity of 100%. CONCLUSIONS: VOC-based detection of prostate cancer seems feasible in principle. While the first results with an electronic nose show some limitations, the approach can compete with other urine-based marker systems. However, it seems less reliable than PSA testing. IMS is more accurate than the electronic nose with promising sensitivity and specificity, which warrants further research. The individual relevant metabolites identified by IMS should further be characterized using gas chromatography/mass spectrometry to facilitate potential targeted rapid testing.


Subject(s)
Electronic Nose , Ion Mobility Spectrometry , Prostatic Neoplasms , Volatile Organic Compounds , Humans , Male , Volatile Organic Compounds/urine , Volatile Organic Compounds/analysis , Prostatic Neoplasms/urine , Prostatic Neoplasms/diagnosis , Ion Mobility Spectrometry/methods , Aged , Middle Aged , Pilot Projects , Sensitivity and Specificity , Aged, 80 and over
9.
Pediatr Pulmonol ; 59(5): 1339-1345, 2024 May.
Article in English | MEDLINE | ID: mdl-38376005

ABSTRACT

BACKGROUND: Markers of airway inflammation can be helpful in the management of childhood asthma. Residential activities, such as intensive asthma camps at alpine altitude climate (AAC), can help reduce bronchial inflammation in patients who fail to achieve optimal control of the disease. Analysis of volatile organic compounds (VOCs) can be obtained using electronic devices such as e-Noses. We aimed to identify alterations in urinary e-Nose sensors among children with asthma participating in an intensive camp at AAC and to investigate associations between urinary e-Nose analysis and airway inflammation. METHODS: We analyzed data collected in children with asthma recruited between July and September 2020. All children were born and resided at altitudes below 600 m asl. Urinary VOCs (measured using the Cyranose 320® VOC analyzer), Fractional exhaled Nitric Oxide (FeNO) and spirometry were evaluated upon children's arrival at the Istituto Pio XII, Misurina (BL), Italy, at 1756 m asl (T0), and after 7 (T1) and 15 days (T2) of stay. RESULTS: Twenty-two patients (68.2% males; median age: 14.5 years) were enrolled. From T0 to T1 and T2, the negative trend for FeNO was significant (p < .001). Significant associations were observed between e-Nose sensors S7 (p = .002), S12 (p = .013), S16 (p = .027), S17 (p = .017), S22 (p = .029), S29 (p = .021), S31 (p = .009) and ΔFeNO at T0-T1. ΔFeNO at T0-T2 was significantly associated with S17 (p = .015), S19 (p = .004), S21 (p = .020), S24 (p = .012), S25 (p = .018), S26 (p = .008), S27 (p = .002), S29 (p = .007), S30 (p = .013). CONCLUSIONS: We showed that a decrease in FeNO levels after a short sojourn at AAC is associated with behaviors of individual urinary e-Nose sensors in children with asthma.


Subject(s)
Altitude , Asthma , Electronic Nose , Volatile Organic Compounds , Humans , Asthma/physiopathology , Male , Female , Pilot Projects , Adolescent , Child , Volatile Organic Compounds/analysis , Volatile Organic Compounds/urine , Spirometry , Italy , Biomarkers/urine , Biomarkers/analysis , Inflammation/physiopathology , Nitric Oxide/analysis , Fractional Exhaled Nitric Oxide Testing
10.
Environ Sci Technol ; 57(49): 20501-20509, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38033144

ABSTRACT

Volatile organic compounds (VOCs) are ubiquitous environmental pollutants and have been implicated in adverse health outcomes. In this study, concentrations of 11 VOC metabolites (mVOCs) and three oxidative stress biomarkers (8-oxo-7,8-dihydro-2'-deoxyguanosine, 8-oxo-7,8-dihydro-guanosine, and dityrosine) were determined in 205 urine samples collected from 12 cities across mainland China. Urinary ∑11mVOC concentrations ranged from 498 to 1660 ng/mL, with a geometric mean (GM) value of 1070 ng/mL. The factorial analysis revealed that cooking, solvents, and vehicle emissions were the three primary sources of VOC exposure. A significant regional variation was clearly found in ∑11mVOC concentrations across four regions in China, with high urine VOC concentrations found in North and South China (GM: 1450 and 1340 ng/mL). The multiple linear regression model revealed that most mVOCs were significantly positively correlated with three oxidative stress markers (ß range: 0.06-0.22). Mixture effect regression showed that isoprene, crotonaldehyde, acrolein, and benzene were the strongest contributors to oxidative stress. Approximately 80% of the participants have HQ values greater than 1.0 for 1,3-butadiene and benzene, suggesting that their exposure doses were close to potential adverse health effects. Our findings provide comprehensive information on human exposure and potential health risks of VOCs in China.


Subject(s)
Air Pollutants , Volatile Organic Compounds , Humans , Air Pollutants/analysis , Volatile Organic Compounds/urine , Environmental Monitoring , Benzene/analysis , Oxidative Stress , China , Environmental Exposure/analysis
11.
Curr Opin Urol ; 33(6): 437-444, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37678152

ABSTRACT

PURPOSE OF REVIEW: Urine volatile organic compound (VOC) testing for early detection of urological cancers is a minimally invasive and promising method. The objective of this review was to present the results of recently published work on this subject. RECENT FINDINGS: Organic volatile compounds are produced through oxidative stress and peroxidation of cell membranes, and they are eliminated through feces, urine, and sweat. Studies looking for VOCs in urine for the diagnosis of urological cancers have mostly focused on bladder and prostate cancers. However, the number of patients included in the studies was small. The electronic nose was the most widely used means of detecting VOCs in urine for the detection of urological cancers. MOS sensors and pattern recognition machine learning were more used for the composition of electronic noses. Early detection of urological cancers by detection of VOCs in urine is a method with encouraging results with sensitivities ranging from 27 to 100% and specificities ranging from 72 to 94%. SUMMARY: The olfactory signature of urine from patients with urological cancers is a promising biomarker for the early diagnosis of urological cancers. The electronic nose with its ability to recognize complex odors is an excellent alterative to canine diagnosis and analytical techniques. Nevertheless, additional research improving the technology of Enoses and the methodology of the studies is necessary for its implementation in daily clinical practice.


Subject(s)
Urologic Neoplasms , Volatile Organic Compounds , Humans , Male , Dogs , Animals , Electronic Nose , Biomarkers , Urologic Neoplasms/diagnosis , Volatile Organic Compounds/urine
12.
Biosensors (Basel) ; 13(6)2023 Jun 06.
Article in English | MEDLINE | ID: mdl-37366992

ABSTRACT

Lung cancer is the leading cause of cancer-related mortality worldwide. Early detection is essential to achieving a better outcome and prognosis. Volatile organic compounds (VOCs) reflect alterations in the pathophysiology and body metabolism processes, as shown in various types of cancers. The biosensor platform (BSP) urine test uses animals' unique, proficient, and accurate ability to scent lung cancer VOCs. The BSP is a testing platform for the binary (negative/positive) recognition of the signature VOCs of lung cancer by trained and qualified Long-Evans rats as biosensors (BSs). The results of the current double-blind study show high accuracy in lung cancer VOC recognition, with 93% sensitivity and 91% specificity. The BSP test is safe, rapid, objective and can be performed repetitively, enabling periodic cancer monitoring as well as an aid to existing diagnostic methods. The future implementation of such urine tests as routine screening and monitoring tools has the potential to significantly increase detection rate as well as curability rates with lower healthcare expenditure. This paper offers a first instructive clinical platform utilizing VOC's in urine for detection of lung cancer using the innovative BSP to deal with the pressing need for an early lung cancer detection test tool.


Subject(s)
Biosensing Techniques , Lung Neoplasms , Volatile Organic Compounds , Animals , Rats , Biosensing Techniques/methods , Early Detection of Cancer/methods , Lung Neoplasms/diagnosis , Rats, Long-Evans , Volatile Organic Compounds/urine , Double-Blind Method
13.
Environ Int ; 173: 107816, 2023 03.
Article in English | MEDLINE | ID: mdl-36805810

ABSTRACT

Volatile organic compounds (VOCs) are a group of pollutants pervasive in daily life with identified adverse health effects. However, no study has investigated the variability in VOC metabolites during pregnancy and their relationships with oxidative stress biomarkers in pregnant women. In the present study, the variability of 21 selected VOC metabolites was examined and their relationships with three selected oxidative stress biomarkers measured in spot urine samples at three trimesters of 1094 pregnant women were analyzed. Nineteen VOC metabolites were ubiquitous in the urine samples with detection rates ranging from 75.9% to 100%. Monohydroxybutenyl mercapturic acid (MHBMA) and s-phenyl mercapturic acid (PMA) had detection rates lower than 1.00%. Intraclass correlation coefficients (ICCs) of the detected analytes at three trimesters ranged 0.07-0.24, and the concentrations were highest in the first trimester. Higher concentrations of some VOC metabolites were related with participant characteristics including higher pre-pregnancy body mass index (BMI), lower education level, unemployment during pregnancy, multiparity, and sampling season of summer or winter. In repeated cross-sectional analyses, interquartile range (IQR) increases in the 19 detected VOC metabolites were positively related with 8-hydroxy-2'-deoxyguanosine (8-OHdG), 8-hydroxyguanosine (8-OHG), and 4-hydroxy nonenal mercapturic acid (HNEMA) with the estimates ranging from 9.00% to 204%. The mixture effect of the VOC metabolites on the oxidative stress biomarkers was further assessed using weighted quantile sum regression (WQS) models and the results showed that the WQS index of VOC metabolite mixture was significantly associated with 8-OHdG (ß: 0.37, 0,32, and 0.39 at the 1st, 2nd, and 3rd trimester, respectively), 8-OHG (0.38, 0.32, and 0.39) and HNEMA (1.21, 1.08, and 1.10). Glycidamide mercapturic acid (GAMA), and trans,trans-muconic acid (MU) were the strongest contributors of the mixture effect on 8-OHdG, 8-OHG, and HNEMA, respectively. Overall, urinary concentrations of the VOC metabolites during pregnancy were strongly associated with the oxidative stress biomarkers.


Subject(s)
Drug-Related Side Effects and Adverse Reactions , Volatile Organic Compounds , Humans , Female , Pregnancy , Pregnant Women , Volatile Organic Compounds/urine , Acetylcysteine , Cross-Sectional Studies , 8-Hydroxy-2'-Deoxyguanosine , Parity , Biomarkers/urine , Oxidative Stress
14.
Clin Chim Acta ; 540: 117236, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36716910

ABSTRACT

BACKGROUND AND AIM: Breast cancer (BC) is the leading cause of cancer-related death in females. The development of non-invasive methods for the early diagnosis of BC still remains challenge. Here, we aimed to discover the urinary volatile organic compounds (VOCs) pattern of BC patients and identify potential VOC biomarkers for BC diagnosis. METHODS: Urine samples were analyzed by headspace-solid phase microextraction (HS-SPME) combined with gas chromatography-high resolution mass spectrometry (GC-HRMS). To assure reliable analysis, the factors influencing HS-SPME extraction efficiency were comprehensively investigated and optimized by combing the Plackett-Burman design (PBD) with the central composite design (CCD). The established HS-SPME/GC-HRMS method was validated and applied to analyze urine samples from BC patients (n = 80) and healthy controls (n = 88). RESULTS: A total number of 134 VOCs belonging to distinct chemical classes were identified by GC-HRMS. BC patients demonstrated unique urinary VOCs pattern. Orthogonal partial least squares-discriminant analysis (OPLS-DA) showed a clear separation between BC patients and healthy controls. Eight potential VOC biomarkers were identified using multivariate and univariate statistical analysis. The predictive ability of candidate VOC biomarkers was further investigated by the random forest (RF) algorithm. The candidate VOC biomarkers yielded 76.3% sensitivity and 85.4% specificity on the training set, and achieved 76.0% sensitivity and 92.3% specificity on the validation set. CONCLUSIONS: Overall, this work not only established a standardized HS-SPME/GC-HRMS approach for urinary VOCs analysis, but also highlighted the value of urinary VOCs for BC diagnosis. The knowledge gained from this study paves the way for early diagnosis of BC using urine in a non-invasive manner.


Subject(s)
Breast Neoplasms , Volatile Organic Compounds , Female , Humans , Breast Neoplasms/diagnosis , Biomarkers, Tumor/urine , Volatile Organic Compounds/urine , Solid Phase Microextraction/methods , Gas Chromatography-Mass Spectrometry/methods
15.
Ecotoxicol Environ Saf ; 251: 114508, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36621033

ABSTRACT

Non-alcoholic fatty liver disease (NAFLD) is one of the most frequent liver diseases among adolescents. Several animal studies have suggested that volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) increase NAFLD risk. However, few epidemiological studies have confirmed the association between VOCs, PAHs and NAFLD in the general adolescent population. Therefore, we analyzed 798 adolescents from the Korean National Environmental Health Survey (KoNEHS), 2015-2017, to examine the associations of urinary metabolites of VOCs and PAHs with serum alanine aminotransferase (ALT) activity and NAFLD prevalence. We performed linear regression, logistic regression, and Bayesian kernel machine regression (BKMR) to evaluate the association of urinary VOCs and PAHs metabolites with ALT levels and NAFLD prevalence. After adjusting for all covariates, urinary benzylmercapturic acid and 2-hydroxyfluorene levels were found to increase ALT activity and NAFLD prevalence. Additionally, the BKMR analyses showed a significantly positive overall effect on ALT activity and NAFLD prevalence with urinary concentrations of VOCs and PAHs metabolites, with 2-hydroxyfluorene as the biggest contributor. Our study suggests that exposure to low-level VOCs and PAHs may have a detrimental effect on NAFLD risk in adolescents. Given the increasing prevalence of NAFLD in adolescents, future cohort studies are confirmed to comprehend the effect of these chemicals on NAFLD risk.


Subject(s)
Non-alcoholic Fatty Liver Disease , Polycyclic Aromatic Hydrocarbons , Volatile Organic Compounds , Humans , Non-alcoholic Fatty Liver Disease/chemically induced , Non-alcoholic Fatty Liver Disease/epidemiology , Polycyclic Aromatic Hydrocarbons/toxicity , Polycyclic Aromatic Hydrocarbons/urine , Volatile Organic Compounds/urine , Bayes Theorem , Environmental Health , Republic of Korea/epidemiology , Biomarkers/urine
16.
Eur J Clin Invest ; 53(1): e13868, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36062918

ABSTRACT

BACKGROUND: As neonates are susceptible for many diseases, establishing noninvasive diagnostic methods is desirable. We hypothesized that volatile organic compounds (VOCs) could be successfully measured in diaper samples. METHODS: We performed a feasibility study to investigate whether ambient air-independent headspace measurements of the VOC profiles of diapers from premature infants can be conducted using ion mobility spectrometer coupled with multi-capillary columns (B & S Analytik GmbH). RESULTS: We analysed 39 diapers filled with stool (n = 10) or urine (n = 20) respectively, using empty diapers as a control (n = 9). A total of 158 different VOCs were identified, and we classified the content of the diapers (urine or stool) according to their VOC profiles with a significance level of p < 0.05. CONCLUSIONS: We have developed a novel method to study headspace VOC profiles of biosamples using ion mobility spectrometry coupled with multi-capillary columns. Using this method, we have characterized the VOC profiles of stool and urine of preterm neonates. Future studies are warranted to characterize specific VOC profiles in infections and other diseases of the preterm neonate, thus establishing quick and noninvasive diagnostics in the routine care of the highly vulnerable preterm and term neonates.


Subject(s)
Volatile Organic Compounds , Infant, Newborn , Humans , Volatile Organic Compounds/urine , Feces/chemistry
17.
Sci Rep ; 12(1): 7774, 2022 05 11.
Article in English | MEDLINE | ID: mdl-35546342

ABSTRACT

Trained detection dogs distinguish between urine samples from healthy organisms and organisms with malignant tumors, suggesting that the volatile urine metabolome contains information about tumor progression. The aim of this study was to determine whether the stage of tumor growth affects the chemical differences in the urine of mice and to what extent the "olfactory image of disease" perceived by dogs coincides with the "image of disease" recorded by the mass spectrometer. We used a novel laser ionization mass spectrometry method and propose a mass spectrometric analysis without detailed interpretation of the spectrum of volatile metabolomes in urine. The mass spectrometer we use works without sample preparation and registers volatile organic compounds in air at room temperature without changing the pH of the sample, i.e. under conditions similar to those in which dogs solve the same problem. The experimental cancer models were male BDF-f1 hybrid mice transplanted with hepatocarcinoma tissue, and similar mice transplanted with healthy liver tissue were used as controls. Our data show that both dogs and our proposed laser mass spectrometry method are able to detect both the entire spectrum of volatile organic compounds associated with the disease and minor changes in this spectrum during its course.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Volatile Organic Compounds , Animals , Dogs , Female , Male , Metabolome , Smell , Volatile Organic Compounds/urine
18.
Br J Cancer ; 127(2): 329-336, 2022 07.
Article in English | MEDLINE | ID: mdl-35352020

ABSTRACT

BACKGROUND: The diagnosis and surveillance of urothelial bladder cancer (UBC) require cystoscopy. There is a need for biomarkers to reduce the frequency of cystoscopy in surveillance; urinary volatile organic compound (VOC) analysis could fulfil this role. This cross-sectional study compared the VOC profiles of patients with and without UBC, to investigate metabolomic signatures as biomarkers. METHODS: Urine samples were collected from haematuria clinic patients undergoing diagnostic cystoscopy and UBC patients undergoing surveillance. Urinary headspace sampling utilised solid-phase microextraction and VOC analysis applied gas chromatography-mass spectrometry; the output underwent metabolomic analysis. RESULTS: The median participant age was 70 years, 66.2% were male. Of the haematuria patients, 21 had a new UBC diagnosis, 125 had no cancer. In the surveillance group, 75 had recurrent UBC, 84 were recurrence-free. A distinctive VOC profile was observed in UBC patients compared with controls. Ten VOCs had statistically significant abundances useful to classify patients (false discovery rate range 1.9 × 10-7-2.8 × 10-2). Two prediction models were evaluated using internal validation. An eight-VOC diagnostic biomarker panel achieved AUROC 0.77 (sensitivity 0.71, specificity 0.72). A six-VOC surveillance biomarker panel obtained AUROC 0.80 (sensitivity 0.71 and specificity 0.80). CONCLUSIONS: Urinary VOC analysis could aid the diagnosis and surveillance of UBC.


Subject(s)
Carcinoma, Transitional Cell , Urinary Bladder Neoplasms , Volatile Organic Compounds , Aged , Biomarkers , Biomarkers, Tumor/urine , Carcinoma, Transitional Cell/diagnosis , Carcinoma, Transitional Cell/urine , Cross-Sectional Studies , Female , Hematuria , Humans , Male , Neoplasm Recurrence, Local , Urinary Bladder Neoplasms/diagnosis , Urinary Bladder Neoplasms/urine , Volatile Organic Compounds/urine
19.
Sci Rep ; 11(1): 20898, 2021 10 22.
Article in English | MEDLINE | ID: mdl-34686703

ABSTRACT

More than one million new cases of prostate cancer (PCa) were reported worldwide in 2020, and a significant increase of PCa incidence up to 2040 is estimated. Despite potential treatability in early stages, PCa diagnosis is challenging because of late symptoms' onset and limits of current screening procedures. It has been now accepted that cell transformation leads to release of volatile organic compounds in biologic fluids, including urine. Thus, several studies proposed the possibility to develop new diagnostic tools based on urine analysis. Among these, electronic noses (eNoses) represent one of the most promising devices, because of their potential to provide a non-invasive diagnosis. Here we describe the approach aimed at defining the experimental protocol for eNose application for PCa diagnosis. Our research investigates effects of sample preparation and analysis on eNose responses and repeatability. The dependence of eNose diagnostic performance on urine portion analysed, techniques involved for extracting urine volatiles and conditioning temperature were analysed. 192 subjects (132 PCa patients and 60 controls) were involved. The developed experimental protocol has resulted in accuracy, sensitivity and specificity of 83% (CI95% 77-89), 82% (CI95% 73-88) and 87% (CI95% 75-94), respectively. Our findings define eNoses as valuable diagnostic tool allowing rapid and non-invasive PCa diagnosis.


Subject(s)
Prostate/pathology , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/urine , Urine/chemistry , Aged , Aged, 80 and over , Electronic Nose , Humans , Male , Middle Aged , Sensitivity and Specificity , Volatile Organic Compounds/urine
20.
Sci Rep ; 11(1): 19801, 2021 10 05.
Article in English | MEDLINE | ID: mdl-34611278

ABSTRACT

Safe and noninvasive methods for breast cancer screening with improved accuracy are urgently needed. Volatile organic compounds (VOCs) in biological samples such as breath and blood have been investigated as noninvasive novel markers of cancer. We investigated volatile organic compounds in urine to assess their potential for the detection of breast cancer. One hundred and ten women with biopsy-proven breast cancer and 177 healthy volunteers were enrolled. The subjects were divided into two groups: a training set and an external validation set. Urine samples were collected and analyzed by gas chromatography and mass spectrometry. A predictive model was constructed by multivariate analysis, and the sensitivity and specificity of the model were confirmed using both a training set and an external set with reproducibility tests. The training set included 60 breast cancer patients (age 34-88 years, mean 60.3) and 60 healthy controls (age 34-81 years, mean 58.7). The external validation set included 50 breast cancer patients (age 35-85 years, mean 58.8) and 117 healthy controls (age 18-84 years, mean 51.2). One hundred and ninety-one compounds detected in at least 80% of the samples from the training set were used for further analysis. The predictive model that best-detected breast cancer at various clinical stages was constructed using a combination of two of the compounds, 2-propanol and 2-butanone. The sensitivity and specificity in the training set were 93.3% and 83.3%, respectively. Triplicated reproducibility tests were performed by randomly choosing ten samples from each group, and the results showed a matching rate of 100% for the breast cancer patient group and 90% for the healthy control group. Our prediction model using two VOCs is a useful complement to the current diagnostic tools. Further studies inclusive of benign tumors and non-breast malignancies are warranted.


Subject(s)
2-Propanol/urine , Biomarkers, Tumor , Breast Neoplasms/diagnosis , Breast Neoplasms/urine , Butanones/urine , Volatile Organic Compounds/urine , Adolescent , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Gas Chromatography-Mass Spectrometry , Humans , Liquid Biopsy , Middle Aged , Neoplasm Grading , Neoplasm Staging , Prognosis , ROC Curve , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...