Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.932
Filter
1.
ACS Appl Mater Interfaces ; 16(21): 27952-27960, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38808703

ABSTRACT

Capable of directly capturing various physiological signals from human skin, skin-interfaced bioelectronics has emerged as a promising option for human health monitoring. However, the accuracy and reliability of the measured signals can be greatly affected by body movements or skin deformations (e.g., stretching, wrinkling, and compression). This study presents an ultraconformal, motion artifact-free, and multifunctional skin bioelectronic sensing platform fabricated by a simple and user-friendly laser patterning approach for sensing high-quality human physiological data. The highly conductive membrane based on the room-temperature coalesced Ag/Cu@Cu core-shell nanoparticles in a mixed solution of polymers can partially dissolve and locally deform in the presence of water to form conformal contact with the skin. The resulting sensors to capture improved electrophysiological signals upon various skin deformations and other biophysical signals provide an effective means to monitor health conditions and create human-machine interfaces. The highly conductive and stretchable membrane can also be used as interconnects to connect commercial off-the-shelf chips to allow extended functionalities, and the proof-of-concept demonstration is highlighted in an integrated pulse oximeter. The easy-to-remove feature of the resulting device with water further allows the device to be applied on delicate skin, such as the infant and elderly.


Subject(s)
Wearable Electronic Devices , Humans , Skin/chemistry , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Silver/chemistry , Copper/chemistry , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Artifacts , Metal Nanoparticles/chemistry , Motion , Electric Conductivity
2.
J Med Syst ; 48(1): 57, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801649

ABSTRACT

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Subject(s)
Electrocardiography, Ambulatory , Electrocardiography , Humans , Female , Male , Middle Aged , Aged , Adult , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Aged, 80 and over , Electrocardiography/instrumentation , Electrocardiography/methods , Wearable Electronic Devices , Young Adult , Clothing , Signal Processing, Computer-Assisted/instrumentation
3.
BMJ Open ; 14(5): e081416, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802273

ABSTRACT

INTRODUCTION: Fatigue is prevalent across a wide range of medical conditions and can be debilitating and distressing. It is likely that fatigue is experienced differently according to the underlying aetiology, but this is poorly understood. Digital health technologies present a promising approach to give new insights into fatigue.The aim of this study is to use digital health technologies, real-time self-reports and qualitative interview data to investigate how fatigue is experienced over time in participants with myeloma, long COVID, heart failure and in controls without problematic fatigue. Objectives are to understand which sensed parameters add value to the characterisation of fatigue and to determine whether study processes are feasible, acceptable and scalable. METHODS AND ANALYSIS: An ecological momentary assessment study will be carried out over 2 or 4 weeks (participant defined). Individuals with fatigue relating to myeloma (n=10), heart failure (n=10), long COVID (n=10) and controls without problematic fatigue or a study condition (n=10) will be recruited. ECG patches will measure heart rate variability, respiratory rate, body temperature, activity and posture. A wearable bracelet accompanied by environment beacons will measure physical activity, sleep and room location within the home. Self-reports of mental and physical fatigue will be collected via smartphone app four times daily and on-demand. Validated fatigue and affect questionnaires will be completed at baseline and at 2 weeks. End-of-study interviews will investigate experiences of fatigue and study participation. A feedback session will be offered to participants to discuss their data.Data will be analysed using multilevel modelling and machine learning. Interviews and feedback sessions will be analysed using content or thematic analyses. ETHICS AND DISSEMINATION: This study was approved by the East of England-Cambridge East Research Ethics Committee (22/EE/0261). The results will be disseminated in peer-reviewed journals and at international conferences. TRIAL REGISTRATION NUMBER: NCT05622669.


Subject(s)
COVID-19 , Ecological Momentary Assessment , Fatigue , Humans , Fatigue/etiology , Heart Failure/physiopathology , Digital Technology , Multiple Myeloma/complications , SARS-CoV-2 , Self Report , Research Design , Wearable Electronic Devices
4.
Sci Rep ; 14(1): 12418, 2024 05 30.
Article in English | MEDLINE | ID: mdl-38816453

ABSTRACT

Body core temperature (Tc) monitoring is crucial for minimizing heat injury risk. However, validated strategies are invasive and expensive. Although promising, aural canal temperature (Tac) is susceptible to environmental influences. This study investigated whether incorporation of external auricle temperature (Tea) into an ear-based Tc algorithm enhances its accuracy during multiple heat stress conditions. Twenty males (mean ± SD; age = 25 ± 3 years, BMI = 21.7 ± 1.8, body fat = 12 ± 3%, maximal aerobic capacity (VO2max) = 64 ± 7 ml/kg/min) donned an ear-based wearable and performed a passive heating (PAH), running (RUN) and brisk walking trial (WALK). PAH comprised of immersion in hot water (42.0 ± 0.3 °C). RUN (70 ± 3%VO2max) and WALK (50 ± 10%VO2max) were conducted in an environmental chamber (Tdb = 30.0 ± 0.2 °C, RH = 71 ± 2%). Several Tc models, developed using Tac, Tea and heart rate, were validated against gastrointestinal temperature. Inclusion of Tea as a model input improved the accuracy of the ear-based Tc algorithm. Our best performing model (Trf3) displayed good group prediction errors (mean bias error = - 0.02 ± 0.26 °C) but exhibited individual prediction errors (percentage target attainment ± 0.40 °C = 88%) that marginally exceeded our validity criterion. Therefore, Trf3 demonstrates potential utility for group-based Tc monitoring, with additional refinement needed to extend its applicability to personalized heat strain monitoring.


Subject(s)
Body Temperature , Ear Auricle , Hot Temperature , Wearable Electronic Devices , Humans , Male , Adult , Body Temperature/physiology , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Ear Auricle/physiology , Young Adult , Heart Rate/physiology , Algorithms
5.
J Neuroeng Rehabil ; 21(1): 85, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807117

ABSTRACT

BACKGROUND: Sensor-based interventions (SI) have been suggested as an alternative rehabilitation treatment to improve older adults' functional performance. However, the effectiveness of different sensor technologies in improving gait and balance remains unclear and requires further investigation. METHODS: Ten databases (Academic Search Premier; Cumulative Index to Nursing and Allied Health Literature, Complete; Cochrane Central Register of Controlled Trials; MEDLINE; PubMed; Web of Science; OpenDissertations; Open grey; ProQuest; and Grey literature report) were searched for relevant articles published up to December 20, 2022. Conventional functional assessments, including the Timed Up and Go (TUG) test, normal gait speed, Berg Balance Scale (BBS), 6-Minute Walk Test (6MWT), and Falling Efficacy Scale-International (FES-I), were used as the evaluation outcomes reflecting gait and balance performance. We first meta-analyzed the effectiveness of SI, which included optical sensors (OPTS), perception sensors (PCPS), and wearable sensors (WS), compared with control groups, which included non-treatment intervention (NTI) and traditional physical exercise intervention (TPEI). We further conducted sub-group analysis to compare the effectiveness of SI (OPTS, PCPS, and WS) with TPEI groups and compared each SI subtype with control (NTI and TPEI) and TPEI groups. RESULTS: We scanned 6255 articles and performed meta-analyses of 58 selected trials (sample size = 2713). The results showed that SI groups were significantly more effective than control or TPEI groups (p < 0.000) in improving gait and balance performance. The subgroup meta-analyses between OPTS groups and TPEI groups revealed clear statistically significant differences in effectiveness for TUG test (mean difference (MD) = - 0.681 s; p < 0.000), normal gait speed (MD = 4.244 cm/s; p < 0.000), BBS (MD = 2.325; p = 0.001), 6MWT (MD = 25.166 m; p < 0.000), and FES-I scores (MD = - 2.036; p = 0.036). PCPS groups also presented statistically significant differences with TPEI groups in gait and balance assessments for normal gait speed (MD = 4.382 cm/s; p = 0.034), BBS (MD = 1.874; p < 0.000), 6MWT (MD = 21.904 m; p < 0.000), and FES-I scores (MD = - 1.161; p < 0.000), except for the TUG test (MD = - 0.226 s; p = 0.106). There were no statistically significant differences in TUG test (MD = - 1.255 s; p = 0.101) or normal gait speed (MD = 6.682 cm/s; p = 0.109) between WS groups and control groups. CONCLUSIONS: SI with biofeedback has a positive effect on gait and balance improvement among a mixed population of older adults. Specifically, OPTS and PCPS groups were statistically better than TPEI groups at improving gait and balance performance, whereas only the group comparison in BBS and 6MWT can reach the minimal clinically important difference. Moreover, WS groups showed no statistically or clinically significant positive effect on gait and balance improvement compared with control groups. More studies are recommended to verify the effectiveness of specific SI. Research registration PROSPERO platform: CRD42022362817. Registered on 7/10/2022.


Subject(s)
Gait , Postural Balance , Randomized Controlled Trials as Topic , Humans , Postural Balance/physiology , Aged , Gait/physiology , Wearable Electronic Devices
6.
Nature ; 629(8014): 1047-1054, 2024 May.
Article in English | MEDLINE | ID: mdl-38778108

ABSTRACT

Wireless modules that provide telecommunications and power-harvesting capabilities enabled by radio-frequency (RF) electronics are vital components of skin-interfaced stretchable electronics1-7. However, recent studies on stretchable RF components have demonstrated that substantial changes in electrical properties, such as a shift in the antenna resonance frequency, occur even under relatively low elastic strains8-15. Such changes lead directly to greatly reduced wireless signal strength or power-transfer efficiency in stretchable systems, particularly in physically dynamic environments such as the surface of the skin. Here we present strain-invariant stretchable RF electronics capable of completely maintaining the original RF properties under various elastic strains using a 'dielectro-elastic' material as the substrate. Dielectro-elastic materials have physically tunable dielectric properties that effectively avert frequency shifts arising in interfacing RF electronics. Compared with conventional stretchable substrate materials, our material has superior electrical, mechanical and thermal properties that are suitable for high-performance stretchable RF electronics. In this paper, we describe the materials, fabrication and design strategies that serve as the foundation for enabling the strain-invariant behaviour of key RF components based on experimental and computational studies. Finally, we present a set of skin-interfaced wireless healthcare monitors based on strain-invariant stretchable RF electronics with a wireless operational distance of up to 30 m under strain.


Subject(s)
Elasticity , Electronics , Equipment Design , Radio Waves , Skin , Stress, Mechanical , Wearable Electronic Devices , Wireless Technology , Humans , Electronics/instrumentation , Wireless Technology/instrumentation , Monitoring, Physiologic/instrumentation
7.
JMIR Ment Health ; 11: e46895, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38819909

ABSTRACT

BACKGROUND: Cognitive symptoms are an underrecognized aspect of depression that are often untreated. High-frequency cognitive assessment holds promise for improving disease and treatment monitoring. Although we have previously found it feasible to remotely assess cognition and mood in this capacity, further work is needed to ascertain the optimal methodology to implement and synthesize these techniques. OBJECTIVE: The objective of this study was to examine (1) longitudinal changes in mood, cognition, activity levels, and heart rate over 6 weeks; (2) diurnal and weekday-related changes; and (3) co-occurrence of fluctuations between mood, cognitive function, and activity. METHODS: A total of 30 adults with current mild-moderate depression stabilized on antidepressant monotherapy responded to testing delivered through an Apple Watch (Apple Inc) for 6 weeks. Outcome measures included cognitive function, assessed with 3 brief n-back tasks daily; self-reported depressed mood, assessed once daily; daily total step count; and average heart rate. Change over a 6-week duration, diurnal and day-of-week variations, and covariation between outcome measures were examined using nonlinear and multilevel models. RESULTS: Participants showed initial improvement in the Cognition Kit N-Back performance, followed by a learning plateau. Performance reached 90% of individual learning levels on average 10 days after study onset. N-back performance was typically better earlier and later in the day, and step counts were lower at the beginning and end of each week. Higher step counts overall were associated with faster n-back learning, and an increased daily step count was associated with better mood on the same (P<.001) and following day (P=.02). Daily n-back performance covaried with self-reported mood after participants reached their learning plateau (P=.01). CONCLUSIONS: The current results support the feasibility and sensitivity of high-frequency cognitive assessments for disease and treatment monitoring in patients with depression. Methods to model the individual plateau in task learning can be used as a sensitive approach to better characterize changes in behavior and improve the clinical relevance of cognitive data. Wearable technology allows assessment of activity levels, which may influence both cognition and mood.


Subject(s)
Affect , Wearable Electronic Devices , Humans , Male , Female , Affect/physiology , Middle Aged , Adult , Longitudinal Studies , Cognition/physiology , Depression/diagnosis , Depression/physiopathology , Heart Rate/physiology
8.
Sci Robot ; 9(90): eadj8812, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38776377

ABSTRACT

To enhance wearable robots, understanding user intent and environmental perception with novel vision approaches is needed.


Subject(s)
Robotics , Wearable Electronic Devices , Robotics/instrumentation , Robotics/trends , Robotics/statistics & numerical data , Humans , Equipment Design , Artificial Intelligence , Intention
9.
Nephrol Nurs J ; 51(2): 153-163, 2024.
Article in English | MEDLINE | ID: mdl-38727591

ABSTRACT

Adults with chronic kidney disease (CKD) tend to be extremely sedentary. We investigated the feasibility and acceptability of a sedentary-reducing intervention for adults with CKD. The intervention utilized telephone-delivered coaching and a consumer wearable device to support participants to reduce their sedentary time. The mean age of participants in the sample was 60.5 years; 72% were women, and 83% had CKD Stage 3. At baseline, participants spent 73% of their waking time sedentary. Inter vention phone call attendance was 100%, study retention was 82%, and the intervention was rated as enjoyable (9.1/10). A telephone-delivered, sedentary-reducing intervention is feasible and acceptable in adults with CKD. Future work is needed investigating the efficacy of sedentary-reducing interventions for adults with CKD.


Subject(s)
Feasibility Studies , Renal Insufficiency, Chronic , Sedentary Behavior , Humans , Female , Renal Insufficiency, Chronic/therapy , Middle Aged , Male , Aged , Wearable Electronic Devices
10.
Mikrochim Acta ; 191(6): 301, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38709350

ABSTRACT

In the era of wearable electronic devices, which are quite popular nowadays, our research is focused on flexible as well as stretchable strain sensors, which are gaining humongous popularity because of recent advances in nanocomposites and their microstructures. Sensors that are stretchable and flexible based on graphene can be a prospective 'gateway' over the considerable biomedical speciality. The scientific community still faces a great problem in developing versatile and user-friendly graphene-based wearable strain sensors that satisfy the prerequisites of susceptible, ample range of sensing, and recoverable structural deformations. In this paper, we report the fabrication, development, detailed experimental analysis and electronic interfacing of a robust but simple PDMS/graphene/PDMS (PGP) multilayer strain sensor by drop casting conductive graphene ink as the sensing material onto a PDMS substrate. Electrochemical exfoliation of graphite leads to the production of abundant, fast and economical graphene. The PGP sensor selective to strain has a broad strain range of ⁓60%, with a maximum gauge factor of 850, detection of human physiological motion and personalized health monitoring, and the versatility to detect stretching with great sensitivity, recovery and repeatability. Additionally, recoverable structural deformation is demonstrated by the PGP strain sensors, and the sensor response is quite rapid for various ranges of frequency disturbances. The structural designation of graphene's overlap and crack structure is responsible for the resistance variations that give rise to the remarkable strain detection properties of this sensor. The comprehensive detection of resistance change resulting from different human body joints and physiological movements demonstrates that the PGP strain sensor is an effective choice for advanced biomedical and therapeutic electronic device utility.


Subject(s)
Dimethylpolysiloxanes , Graphite , Wearable Electronic Devices , Graphite/chemistry , Humans , Dimethylpolysiloxanes/chemistry , Movement
11.
Chem Rev ; 124(10): 6145-6147, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38773952
12.
Sci Rep ; 14(1): 10779, 2024 05 11.
Article in English | MEDLINE | ID: mdl-38734824

ABSTRACT

Health apps and wearables are touted to improve physical health and mental well-being. However, it is unclear from existing research the extent to which these health technologies are efficacious in improving physical and mental well-being at a population level, particularly for the underserved groups from the perspective of health equity and social determinants. Also, it is unclear if the relationship between health apps and wearables use and physical and mental well-being differs across individualistic, collectivistic, and a mix of individual-collectivistic cultures. A large-scale online survey was conducted in the U.S. (individualist culture), China (collectivist culture), and Singapore (mix of individual-collectivist culture) using quota sampling after obtaining ethical approval from the Institutional Review Board (IRB-2021-262) of Nanyang Technological University (NTU), Singapore. There was a total of 1004 respondents from the U.S., 1072 from China, and 1017 from Singapore. Data were analyzed using multiple regression and negative binomial regression. The study found that income consistently had the strongest relationship with physical and mental well-being measures in all three countries, while the use of health apps and wearables only had a moderate association with psychological well-being only in the US. Health apps and wearables were associated with the number of times people spent exercising and some mental health outcomes in China and Singapore, but they were only positively associated with psychological well-being in the US. The study emphasizes the importance of considering the social determinants, social-cultural context of the population, and the facilitating conditions for the effective use of digital health technologies. The study suggests that the combined use of both health apps and wearables is most strongly associated with better physical and mental health, though this association is less pronounced when individuals use only apps or wearables.


Subject(s)
Mental Health , Mobile Applications , Wearable Electronic Devices , Humans , Singapore , Male , China , Female , United States , Adult , Middle Aged , Surveys and Questionnaires , Young Adult , Adolescent , Aged
13.
J Biomed Opt ; 29(6): 065001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38737791

ABSTRACT

Significance: Type 2 diabetes mellitus (T2DM) is a global health concern with significant implications for vascular health. The current evaluation methods cannot achieve effective, portable, and quantitative evaluation of foot microcirculation. Aim: We aim to use a wearable device laser Doppler flowmetry (LDF) to evaluate the foot microcirculation of T2DM patients at rest. Approach: Eleven T2DM patients and twelve healthy subjects participated in this study. The wearable LDF was used to measure the blood flows (BFs) for regions of the first metatarsal head (M1), fifth metatarsal head (M5), heel, and dorsal foot. Typical wavelet analysis was used to decompose the five individual control mechanisms: endothelial, neurogenic, myogenic, respiratory, and heart components. The mean BF and sample entropy (SE) were calculated, and the differences between diabetic patients and healthy adults and among the four regions were compared. Results: Diabetic patients showed significantly reduced mean BF in the neurogenic (p=0.044) and heart (p=0.001) components at the M1 and M5 regions (p=0.025) compared with healthy adults. Diabetic patients had significantly lower SE in the neurogenic (p=0.049) and myogenic (p=0.032) components at the M1 region, as well as in the endothelial (p<0.001) component at the M5 region and in the myogenic component at the dorsal foot (p=0.007), compared with healthy adults. The SE in the myogenic component at the dorsal foot was lower than at the M5 region (p=0.050) and heel area (p=0.041). Similarly, the SE in the heart component at the dorsal foot was lower than at the M5 region (p=0.017) and heel area (p=0.028) in diabetic patients. Conclusions: This study indicated the potential of using the novel wearable LDF device for tracking vascular complications and implementing targeted interventions in T2DM patients.


Subject(s)
Diabetes Mellitus, Type 2 , Diabetic Foot , Foot , Laser-Doppler Flowmetry , Microcirculation , Wearable Electronic Devices , Humans , Diabetic Foot/physiopathology , Diabetic Foot/diagnostic imaging , Male , Microcirculation/physiology , Female , Laser-Doppler Flowmetry/methods , Diabetes Mellitus, Type 2/physiopathology , Middle Aged , Foot/blood supply , Aged , Wavelet Analysis , Adult
14.
ACS Nano ; 18(20): 12808-12819, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38717026

ABSTRACT

Considerable progress has already been made in sweat sensors based on electrochemical methods to realize real-time monitoring of biomarkers. However, realizing long-term monitoring of multiple targets at the atomic level remains extremely challenging, in terms of designing stable solid contact (SC) interfaces and fully integrating multiple modules for large-scale applications of sweat sensors. Herein, a fully integrated wristwatch was designed using mass-manufactured sensor arrays based on hierarchical multilayer-pore cross-linked N-doped porous carbon coated by reduced graphene oxide (NPCs@rGO-950) microspheres with high hydrophobicity as core SC, and highly selective monitoring simultaneously for K+, Na+, and Ca2+ ions in human sweat was achieved, exhibiting near-Nernst responses almost without forming an interfacial water layer. Combined with computed tomography, solid-solid interface potential diffusion simulation results reveal extremely low interface diffusion potential and high interface capacitance (598 µF), ensuring the excellent potential stability, reversibility, repeatability, and selectivity of sensor arrays. The developed highly integrated-multiplexed wristwatch with multiple modules, including SC, sensor array, microfluidic chip, signal transduction, signal processing, and data visualization, achieved reliable real-time monitoring for K+, Na+, and Ca2+ ion concentrations in sweat. Ingenious material design, scalable sensor fabrication, and electrical integration of multimodule wearables lay the foundation for developing reliable sweat-sensing systems for health monitoring.


Subject(s)
Electrolytes , Graphite , Sweat , Wearable Electronic Devices , Sweat/chemistry , Humans , Graphite/chemistry , Electrolytes/chemistry , Ions/analysis , Calcium/analysis , Sodium/analysis , Sodium/chemistry , Biosensing Techniques/instrumentation , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Potassium/analysis
15.
Article in English | MEDLINE | ID: mdl-38723798

ABSTRACT

Wearable and implantable sensing of biomechanical signals such as pressure, strain, shear, and vibration can enable a multitude of human-integrated applications, including on-skin monitoring of vital signs, motion tracking, monitoring of internal organ condition, restoration of lost/impaired mechanoreception, among many others. The mechanical conformability of such sensors to the human skin and tissue is critical to enhancing their biocompatibility and sensing accuracy. As such, in the recent decade, significant efforts have been made in the development of soft mechanical sensors. To satisfy the requirements of different wearable and implantable applications, such sensors have been imparted with various additional properties to make them better suited for the varied contexts of human-integrated applications. In this review, focusing on the four major types of soft mechanical sensors for pressure, strain, shear, and vibration, we discussed the recent material and device design innovations for achieving several important properties, including flexibility and stretchability, bioresorbability and biodegradability, self-healing properties, breathability, transparency, wireless communication capabilities, and high-density integration. We then went on to discuss the current research state of the use of such novel soft mechanical sensors in wearable and implantable applications, based on which future research needs were further discussed. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Implantable Materials and Surgical Technologies > Nanomaterials and Implants.


Subject(s)
Prostheses and Implants , Wearable Electronic Devices , Humans , Equipment Design , Biosensing Techniques/instrumentation , Monitoring, Physiologic/instrumentation
16.
J Neuroeng Rehabil ; 21(1): 82, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769565

ABSTRACT

BACKGROUND: Assessments of arm motor function are usually based on clinical examinations or self-reported rating scales. Wrist-worn accelerometers can be a good complement to measure movement patterns after stroke. Currently there is limited knowledge of how accelerometry correlate to clinically used scales. The purpose of this study was therefore to evaluate the relationship between intermittent measurements of wrist-worn accelerometers and the patient's progression of arm motor function assessed by routine clinical outcome measures during a rehabilitation period. METHODS: Patients enrolled in in-hospital rehabilitation following a stroke were invited. Included patients were asked to wear wrist accelerometers for 24 h at the start (T1) and end (T2) of their rehabilitation period. On both occasions arm motor function was assessed by the modified Motor Assessment Scale (M_MAS) and the Motor Activity Log (MAL). The recorded accelerometry was compared to M_MAS and MAL. RESULTS: 20 patients were included, of which 18 completed all measurements and were therefore included in the final analysis. The resulting Spearman's rank correlation coefficient showed a strong positive correlation between measured wrist acceleration in the affected arm and M-MAS and MAL values at T1, 0.94 (p < 0.05) for M_MAS and 0.74 (p < 0.05) for the MAL values, and a slightly weaker positive correlation at T2, 0.57 (p < 0.05) for M_MAS and 0.46 - 0.45 (p = 0.06) for the MAL values. However, no correlation was seen for the difference between the two sessions. CONCLUSIONS: The results confirm that the wrist acceleration can differentiate between the affected and non-affected arm, and that there is a positive correlation between accelerometry and clinical measures. Many of the patients did not change their M-MAS or MAL scores during the rehabilitation period, which may explain why no correlation was seen for the difference between measurements during the rehabilitation period. Further studies should include continuous accelerometry throughout the rehabilitation period to reduce the impact of day-to-day variability.


Subject(s)
Accelerometry , Arm , Stroke Rehabilitation , Humans , Accelerometry/instrumentation , Male , Female , Middle Aged , Aged , Stroke Rehabilitation/methods , Stroke Rehabilitation/instrumentation , Arm/physiopathology , Arm/physiology , Wrist/physiology , Wearable Electronic Devices , Motor Activity/physiology , Adult , Stroke/physiopathology , Stroke/diagnosis , Aged, 80 and over
17.
ACS Appl Mater Interfaces ; 16(19): 25181-25193, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38698676

ABSTRACT

Supermolecular hydrogel ionic skin (i-skin) linked with smartphones has attracted widespread attention in physiological activity detection due to its good stability in complex scenarios. However, the low ionic conductivity, inferior mechanical properties, poor contact adhesion, and insufficient freeze resistance of most used hydrogels limit their practical application in flexible electronics. Herein, a novel multifunctional poly(vinyl alcohol)-based conductive organohydrogel (PCEL5.0%) with a supermolecular structure was constructed by innovatively employing sodium carboxymethyl cellulose (CMC-Na) as reinforcement material, ethylene glycol as antifreeze, and lithium chloride as a water retaining agent. Thanks to the synergistic effect of these components, the PCEL5.0% organohydrogel shows excellent performance in terms of ionic conductivity (1.61 S m-1), mechanical properties (tensile strength of 70.38 kPa and elongation at break of 537.84%), interfacial adhesion (1.06 kPa to pig skin), frost resistance (-50.4 °C), water retention (67.1% at 22% relative humidity), and remoldability. The resultant PCEL5.0%-based i-skin delivers satisfactory sensitivity (GF = 1.38) with fast response (348 ms) and high precision under different deformations and low temperature (-25 °C). Significantly, the wireless sensor system based on the PCEL5.0% organohydrogel i-skin can transmit signals from physiological activities and sign language to a smartphone by Bluetooth technology and dynamically displays the status of these movements. The organohydrogel i-skin shows great potential in diverse fields of physiological activity detection, human-computer interaction, and rehabilitation medicine.


Subject(s)
Hydrogels , Hydrogels/chemistry , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Animals , Wireless Technology , Wearable Electronic Devices , Electric Conductivity , Humans , Polyvinyl Alcohol/chemistry , Swine , Smartphone , Skin/chemistry , Carboxymethylcellulose Sodium/chemistry
18.
J Neural Eng ; 21(3)2024 May 16.
Article in English | MEDLINE | ID: mdl-38718785

ABSTRACT

Objective.Recently, the demand for wearable devices using electroencephalography (EEG) has increased rapidly in many fields. Due to its volume and computation constraints, wearable devices usually compress and transmit EEG to external devices for analysis. However, current EEG compression algorithms are not tailor-made for wearable devices with limited computing and storage. Firstly, the huge amount of parameters makes it difficult to apply in wearable devices; secondly, it is tricky to learn EEG signals' distribution law due to the low signal-to-noise ratio, which leads to excessive reconstruction error and suboptimal compression performance.Approach.Here, a feature enhanced asymmetric encoding-decoding network is proposed. EEG is encoded with a lightweight model, and subsequently decoded with a multi-level feature fusion network by extracting the encoded features deeply and reconstructing the signal through a two-branch structure.Main results.On public EEG datasets, motor imagery and event-related potentials, experimental results show that the proposed method has achieved the state of the art compression performance. In addition, the neural representation analysis and the classification performance of the reconstructed EEG signals also show that our method tends to retain more task-related information as the compression ratio increases and retains reliable discriminative information after EEG compression.Significance.This paper tailors an asymmetric EEG compression method for wearable devices that achieves state-of-the-art compression performance in a lightweight manner, paving the way for the application of EEG-based wearable devices.


Subject(s)
Data Compression , Electroencephalography , Electroencephalography/methods , Data Compression/methods , Humans , Wearable Electronic Devices , Neural Networks, Computer , Algorithms , Signal Processing, Computer-Assisted , Imagination/physiology
19.
PLoS One ; 19(5): e0301851, 2024.
Article in English | MEDLINE | ID: mdl-38696453

ABSTRACT

This study tested the usability of a home-based self-administration transcranial direct current stimulation (tDCS) device designed specifically for women's health needs. This is a single center triple blinded clinical usability study for a new wireless, Bluetooth-controlled wearable tDCS device for women's health. The study aims to evaluate the usability and effective blinding of a home-based tDCS system. A total of forty-nine women of reproductive age were randomly allocated (1:1) to receive one session of active tDCS (n = 24) or sham tDCS (n = 25) over the motor and dorsolateral prefrontal cortex. Each participant self-administered one 20-minute session without supervision following guidance on a software application alone. The System Usability Scale (SUS) and the Patient Global Impression of Change (PGIC) were used to evaluate the usability of the system. Regardless of sham or active conditions, all users found the system easy to use without the support of researchers. Usability scores were considered to be "excellent" in both groups and no significant difference was found between sham and active groups showing effective blinding of the device (Active group: 93.7 (83.1-97.5); Sham group 90 (86.2-95) p = 0.79) and PGIC (Active group: 2 (1-2.75); Sham group 2 (1-2) p = 0.99) using an unpaired t-test or non-parametric statistical tests accordingly. The new Bluetooth-controlled wearable tDCS device is easy, safe to use and completely controlled by a smartphone app. This device is focused on women's health and will be tested as an alternative treatment for chronic pelvic pain and mood disturbance associated with menstrual cycles in further research.


Subject(s)
Dysmenorrhea , Transcranial Direct Current Stimulation , Humans , Female , Adult , Transcranial Direct Current Stimulation/methods , Transcranial Direct Current Stimulation/instrumentation , Dysmenorrhea/therapy , Young Adult , Self Administration/instrumentation , Wearable Electronic Devices , Prefrontal Cortex/physiology
20.
Sci Rep ; 14(1): 9971, 2024 04 30.
Article in English | MEDLINE | ID: mdl-38693325

ABSTRACT

Sociopositive interactions with conspecifics are essential for equine welfare and quality of life. This study aimed to validate the use of wearable ultra-wideband (UWB) technology to quantify the spatial relationships and dynamics of social behaviour in horses by continuous (1/s) measurement of interindividual distances. After testing the UWB devices' spatiotemporal accuracy in a static environment, the UWB measurement validity, feasibility and utility under dynamic field conditions was assessed in a group of 8 horses. Comparison of the proximity measurements with video surveillance data established the measurement accuracy and validity (r = 0.83, p < 0.0001) of the UWB technology. The utility for social behaviour research was demonstrated by the excellent accordance of affiliative relationships (preferred partners) identified using UWB with video observations. The horses remained a median of 5.82 m (95% CI 5.13-6.41 m) apart from each other and spent 20% (median, 95% CI 14-26%) of their time in a distance ≤ 3 m to their preferred partner. The proximity measurements and corresponding speed calculation allowed the identification of affiliative versus agonistic approaches based on differences in the approach speed and the distance and duration of the resulting proximity. Affiliative approaches were statistically significantly slower (median: 1.57 km/h, 95% CI 1.26-1.92 km/h, p = 0.0394) and resulted in greater proximity (median: 36.75 cm, 95% CI 19.5-62 cm, p = 0.0003) to the approached horse than agonistic approaches (median: 3.04 km/h, 95% CI 2.16-3.74 km/h, median proximity: 243 cm, 95% CI 130-319 cm), which caused an immediate retreat of the approached horse at a significantly greater speed (median: 3.77 km/h, 95% CI 3.52-5.85 km/h, p < 0.0001) than the approach.


Subject(s)
Behavior, Animal , Social Behavior , Animals , Horses , Male , Female , Wearable Electronic Devices , Video Recording
SELECTION OF CITATIONS
SEARCH DETAIL
...