Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.361
Filter
1.
Sci Rep ; 14(1): 10136, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38698049

ABSTRACT

Exocrine and endocrine pancreas are interconnected anatomically and functionally, with vasculature facilitating bidirectional communication. Our understanding of this network remains limited, largely due to two-dimensional histology and missing combination with three-dimensional imaging. In this study, a multiscale 3D-imaging process was used to analyze a porcine pancreas. Clinical computed tomography, digital volume tomography, micro-computed tomography and Synchrotron-based propagation-based imaging were applied consecutively. Fields of view correlated inversely with attainable resolution from a whole organism level down to capillary structures with a voxel edge length of 2.0 µm. Segmented vascular networks from 3D-imaging data were correlated with tissue sections stained by immunohistochemistry and revealed highly vascularized regions to be intra-islet capillaries of islets of Langerhans. Generated 3D-datasets allowed for three-dimensional qualitative and quantitative organ and vessel structure analysis. Beyond this study, the method shows potential for application across a wide range of patho-morphology analyses and might possibly provide microstructural blueprints for biotissue engineering.


Subject(s)
Imaging, Three-Dimensional , Multimodal Imaging , Pancreas , Animals , Imaging, Three-Dimensional/methods , Pancreas/diagnostic imaging , Pancreas/blood supply , Swine , Multimodal Imaging/methods , X-Ray Microtomography/methods , Islets of Langerhans/diagnostic imaging , Islets of Langerhans/blood supply , Tomography, X-Ray Computed/methods
2.
J Clin Pediatr Dent ; 48(3): 139-145, 2024 May.
Article in English | MEDLINE | ID: mdl-38755992

ABSTRACT

The endodontic treatment of immature permanent teeth with necrotic pulp is a significant clinical challenge. The success of regenerative endodontic procedure is highly dependent on disinfection of the root canal and an accurate anatomical knowledge of the root canal. The aim of this study was to use micro-computed tomography (micro-CT) analysis to investigate the configuration of root canals in the upper permanent third maxillary molars with incomplete root development in their coronal, apical and middle third portions. Thirty immature third permanent maxillary molars were scanned using a micro-CT system. Then, we measured the diameters and areas of the root canal in the coronal, middle and apical third of the roots. The ratio between the long and short diameter of each root canal was then calculated and the canals were divided into several groups: round, oval, long oval, flat and irregular. The round configuration was not observed in the distobuccal and mesiobuccal roots in any of their anatomical regions. Oval and long oval canals predominated in the distobuccal root. The greatest variations were observed in the mesiobuccal root, with the ribbon-shaped canal predominating in the middle region and an irregular shape in the apical region. In the coronal region of the palatal canal, the round configuration predominated; in the middle third, we observed an almost equivalent distribution between round and oval configurations; apically, the oval shape predominated. In conclusion, we observed significant complexity and variation in the morphology and configuration of root canals in immature permanent molars, thus generating additional obstacles for the success of regenerative endodontics.


Subject(s)
Dental Pulp Cavity , Maxilla , Molar, Third , X-Ray Microtomography , Humans , X-Ray Microtomography/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Maxilla/diagnostic imaging , Maxilla/anatomy & histology , Molar, Third/diagnostic imaging , Molar, Third/anatomy & histology , Child , Tooth Root/diagnostic imaging , Tooth Root/anatomy & histology
3.
Eur Radiol Exp ; 8(1): 58, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735899

ABSTRACT

BACKGROUND: Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment. METHODS: We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation. RESULTS: We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (p = 0.806) (Pearson correlation coefficient r = 0.92, p = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, p = 0.002). CONCLUSIONS: Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible. RELEVANCE STATEMENT: 3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics. KEY POINTS: • Matrix calcifications are a relevant diagnostic feature of bone tumors. • Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma. • Micro-CT has the potential to be an integrative part of clinical diagnostics.


Subject(s)
Bone Neoplasms , Chondrosarcoma , Feasibility Studies , Imaging, Three-Dimensional , X-Ray Microtomography , Humans , Chondrosarcoma/diagnostic imaging , Chondrosarcoma/pathology , X-Ray Microtomography/methods , Aged , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/pathology , Middle Aged , Retrospective Studies , Imaging, Three-Dimensional/methods , Male , Female , Staining and Labeling/methods
4.
J Appl Oral Sci ; 32: e20230440, 2024.
Article in English | MEDLINE | ID: mdl-38775557

ABSTRACT

This study aimed to compare the quality of root canal obturation (ratio of area occupied by gutta-percha (G), sealer (S), and presence of voids (V)) in different anatomical irregularities (intercanal communications, lateral irregularities, and accessory canals) located at different thirds of the root canal system of mandibular molar replicas. Sixty-seven 3D printed replicas of an accessed mandibular molar were prepared using ProGlider and ProTaper Gold rotatory systems. Three specimens were randomly selected to be used as controls and did not receive further treatment. The rest were randomly distributed in 4 experimental groups to be obturated using either cold lateral compaction (LC), continuous wave of condensation (CW), and core-carrier obturation (ThermafilPlus (TH) or GuttaCore (GC)) (n=16 per group). AHPlus® sealer was used in all groups. The three controls and a specimen from each experimental group were scanned using micro-computed tomography. The rest of the replicas were sectioned at the sites of anatomical irregularities and examined at 30× magnification. The G, S, and V ratios were calculated dividing the area occupied with each element by the total root canal area and then compared among groups using the Kruskal-Wallis test. Voids were present in all obturation techniques with ratios from 0.01 to 0.15. CW obtained a significantly higher G ratio in the irregularity located in the coronal third (0.882) than LC (0.681), TH (0.773), and GC (0.801) (p<0.05). TH and GC achieved significantly higher G ratios in those located in the apical third (p<0.05). The worst quality of obturation was observed in the loop accessory canal with all obturation techniques. Whitin the limitations of this study, it can be concluded that CW and core-carrier obturation are respectively the most effective techniques for obturating anatomical irregularities located in the coronal and the apical third.


Subject(s)
Dental Pulp Cavity , Gutta-Percha , Materials Testing , Root Canal Filling Materials , Root Canal Obturation , X-Ray Microtomography , Root Canal Obturation/methods , Root Canal Filling Materials/chemistry , X-Ray Microtomography/methods , Gutta-Percha/chemistry , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/diagnostic imaging , Humans , Reproducibility of Results , Reference Values , Molar/anatomy & histology , Epoxy Resins/chemistry , Printing, Three-Dimensional , Surface Properties , Statistics, Nonparametric , Random Allocation
5.
PLoS One ; 19(5): e0303288, 2024.
Article in English | MEDLINE | ID: mdl-38781243

ABSTRACT

BACKGROUND: Brain region segmentation and morphometry in humanized apolipoprotein E (APOE) mouse models with a human NOS2 background (HN) contribute to Alzheimer's disease (AD) research by demonstrating how various risk factors affect the brain. Photon-counting detector (PCD) micro-CT provides faster scan times than MRI, with superior contrast and spatial resolution to energy-integrating detector (EID) micro-CT. This paper presents a pipeline for mouse brain imaging, segmentation, and morphometry from PCD micro-CT. METHODS: We used brains of 26 mice from 3 genotypes (APOE22HN, APOE33HN, APOE44HN). The pipeline included PCD and EID micro-CT scanning, hybrid (PCD and EID) iterative reconstruction, and brain region segmentation using the Small Animal Multivariate Brain Analysis (SAMBA) tool. We applied SAMBA to transfer brain region labels from our new PCD CT atlas to individual PCD brains via diffeomorphic registration. Region-based and voxel-based analyses were used for comparisons by genotype and sex. RESULTS: Together, PCD and EID scanning take ~5 hours to produce images with a voxel size of 22 µm, which is faster than MRI protocols for mouse brain morphometry with voxel size above 40 µm. Hybrid iterative reconstruction generates PCD images with minimal artifacts and higher spatial resolution and contrast than EID images. Our PCD atlas is qualitatively and quantitatively similar to the prior MRI atlas and successfully transfers labels to PCD brains in SAMBA. Male and female mice had significant volume differences in 26 regions, including parts of the entorhinal cortex and cingulate cortex. APOE22HN brains were larger than APOE44HN brains in clusters from the hippocampus, a region where atrophy is associated with AD. CONCLUSIONS: This work establishes a pipeline for mouse brain analysis using PCD CT, from staining to imaging and labeling brain images. Our results validate the effectiveness of the approach, setting a foundation for research on AD mouse models while reducing scanning durations.


Subject(s)
Brain , X-Ray Microtomography , Animals , Brain/diagnostic imaging , Mice , X-Ray Microtomography/methods , Female , Male , Humans , Alzheimer Disease/diagnostic imaging , Alzheimer Disease/genetics , Alzheimer Disease/pathology , Image Processing, Computer-Assisted/methods , Apolipoproteins E/genetics , Mice, Transgenic
6.
J Vis Exp ; (206)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38738893

ABSTRACT

The mechanical property, microhardness, is evaluated in dental enamel, dentin, and bone in oral disease models, including dental fluorosis and periodontitis. Micro-CT (µCT) provides 3D imaging information (volume and mineral density) and scanning electron microscopy (SEM) produces microstructure images (enamel prism and bone lacuna-canalicular). Complementarily to structural analysis by µCT and SEM, microhardness is one of the informative parameters to evaluate how structural changes alter mechanical properties. Despite being a useful parameter, studies on microhardness of alveolar bone in oral diseases are limited. To date, divergent microhardness measurement methods have been reported. Since microhardness values vary depending on the sample preparation (polishing and flat surface) and indentation sites, diverse protocols can cause discrepancies among studies. Standardization of the microhardness protocol is essential for consistent and accurate evaluation in oral disease models. In the present study, we demonstrate a standardized protocol for microhardness analysis in tooth and alveolar bone. Specimens used are as follows: for the dental fluorosis model, incisors were collected from mice treated with/without fluoride-containing water for 6 weeks; for ligature-induced periodontal bone resorption (L-PBR) model, alveolar bones with periodontal bone resorption were collected from mice ligated on the maxillary 2nd molar. At 2 weeks after the ligation, the maxilla was collected. Vickers hardness was analyzed in these specimens according to the standardized protocol. The protocol provides detailed materials and methods for resin embedding, serial polishing, and indentation sites for incisors and alveolar. To the best of our knowledge, this is the first standardized microhardness protocol to evaluate the mechanical properties of tooth and alveolar bone in rodent oral disease models.


Subject(s)
Alveolar Process , Disease Models, Animal , X-Ray Microtomography , Animals , Mice , Alveolar Process/diagnostic imaging , X-Ray Microtomography/methods , Fluorosis, Dental/diagnostic imaging , Fluorosis, Dental/pathology , Hardness , Incisor/diagnostic imaging , Tooth/diagnostic imaging
7.
Sci Rep ; 14(1): 10875, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38740845

ABSTRACT

Three-dimensional information is essential for a proper understanding of the healing potential of the menisci and their overall role in the knee joint. However, to date, the study of meniscal vascularity has relied primarily on two-dimensional imaging techniques. Here we present a method to elucidate the intricate 3D meniscal vascular network, revealing its spatial arrangement, connectivity and density. A polymerizing contrast agent was injected into the femoral artery of human cadaver legs, and the meniscal microvasculature was examined using micro-computed tomography at different levels of detail and resolution. The 3D vascular network was quantitatively assessed in a zone-base analysis using parameters such as diameter, length, tortuosity, and branching patterns. The results of this study revealed distinct vascular patterns within the meniscus, with the highest vascular volume found in the outer perimeniscal zone. Variations in vascular parameters were found between the different circumferential and radial meniscal zones. Moreover, through state-of-the-art 3D visualization using micro-CT, this study highlighted the importance of spatial resolution in accurately characterizing the vascular network. These findings, both from this study and from future research using this technique, improve our understanding of microvascular distribution, which may lead to improved therapeutic strategies.


Subject(s)
Imaging, Three-Dimensional , Microvessels , X-Ray Microtomography , Humans , Imaging, Three-Dimensional/methods , Microvessels/diagnostic imaging , X-Ray Microtomography/methods , Menisci, Tibial/diagnostic imaging , Menisci, Tibial/blood supply , Meniscus/diagnostic imaging , Male , Cadaver , Female
8.
Radiology ; 311(2): e231921, 2024 May.
Article in English | MEDLINE | ID: mdl-38805732

ABSTRACT

Background Many clinically relevant fractures are occult on conventional radiographs and therefore challenging to diagnose reliably. X-ray dark-field radiography is a developing method that uses x-ray scattering as an additional signal source. Purpose To investigate whether x-ray dark-field radiography enhances the depiction of radiographically occult fractures in an experimental model compared with attenuation-based radiography alone and whether the directional dependence of dark-field signal impacts observer ratings. Materials and Methods Four porcine loin ribs had nondisplaced fractures experimentally introduced. Microstructural changes were visually verified using high-spatial-resolution three-dimensional micro-CT. X-ray dark-field radiographs were obtained before and after fracture, with the before-fracture scans serving as control images. The presence of a fracture was scored by three observers using a six-point scale (6, surely; 5, very likely; 4, likely; 3, unlikely; 2, very unlikely; and 1, certainly not). Differences between scores based on attenuation radiographs alone (n = 96) and based on combined attenuation and dark-field radiographs (n = 96) were evaluated by using the DeLong method to compare areas under the receiver operating characteristic curve. The impact of the dark-field signal directional sensitivity on observer ratings was evaluated using the Wilcoxon test. The dark-field data were split into four groups (24 images per group) according to their sensitivity orientation and tested against each other. Musculoskeletal dark-field radiography was further demonstrated on human finger and foot specimens. Results The addition of dark-field radiographs was found to increase the area under the receiver operating characteristic curve to 1 compared with an area under the receiver operating characteristic curve of 0.87 (95% CI: 0.80, 0.94) using attenuation-based radiographs alone (P < .001). There were similar observer ratings for the four different dark-field sensitivity orientations (P = .16-.65 between the groups). Conclusion These results suggested that the inclusion of dark-field radiography has the potential to help enhance the detection of nondisplaced fractures compared with attenuation-based radiography alone. © RSNA, 2024 See also the editorial by Rubin in this issue.


Subject(s)
Feasibility Studies , Animals , Swine , X-Ray Microtomography/methods , Rib Fractures/diagnostic imaging , Fractures, Closed/diagnostic imaging , Radiographic Image Enhancement/methods
9.
J Vis Exp ; (207)2024 May 10.
Article in English | MEDLINE | ID: mdl-38801271

ABSTRACT

Large-scale calvarial defects often coincide with cranial suture disruption, leading to impairments in calvarial defect restoration and skull development (the latter occurs in the developing cranium). However, the lack of a standardized model hinders progress in investigating suture-regenerative therapies and poses challenges for conducting comparative analyses across distinct studies. To address this issue, the current protocol describes the detailed modeling process of calvarial suture-bony composite defects in rats. The model was generated by drilling full-thickness rectangular holes measuring 4.5 mm × 2 mm across the coronal sutures. The rats were euthanized, and the cranium samples were harvested postoperatively at day 0, week 2, week 6, and week 12. µCT results from samples collected immediately post-surgery confirmed the successful establishment of the suture-bony composite defect, involving the removal of the coronal suture and the adjacent bone tissues. Data from the 6th and 12th postoperative weeks demonstrated a natural healing tendency for the defect to close. Histological staining further validated this trend by showing increased mineralized fibers and new bone at the defect center. These findings indicate progressive suture fusion over time following calvarial defects, underscoring the significance of therapeutic interventions for suture regeneration. We anticipate that this protocol will facilitate the development of suture-regenerative therapies, offering fresh insights into the functional restoration of calvarial defects and reducing adverse outcomes associated with suture loss.


Subject(s)
Cranial Sutures , Skull , Animals , Rats , Skull/surgery , Cranial Sutures/surgery , Disease Models, Animal , X-Ray Microtomography/methods , Male , Rats, Sprague-Dawley , Bone Regeneration/physiology
10.
Cell ; 187(10): 2502-2520.e17, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38729110

ABSTRACT

Human tissue, which is inherently three-dimensional (3D), is traditionally examined through standard-of-care histopathology as limited two-dimensional (2D) cross-sections that can insufficiently represent the tissue due to sampling bias. To holistically characterize histomorphology, 3D imaging modalities have been developed, but clinical translation is hampered by complex manual evaluation and lack of computational platforms to distill clinical insights from large, high-resolution datasets. We present TriPath, a deep-learning platform for processing tissue volumes and efficiently predicting clinical outcomes based on 3D morphological features. Recurrence risk-stratification models were trained on prostate cancer specimens imaged with open-top light-sheet microscopy or microcomputed tomography. By comprehensively capturing 3D morphologies, 3D volume-based prognostication achieves superior performance to traditional 2D slice-based approaches, including clinical/histopathological baselines from six certified genitourinary pathologists. Incorporating greater tissue volume improves prognostic performance and mitigates risk prediction variability from sampling bias, further emphasizing the value of capturing larger extents of heterogeneous morphology.


Subject(s)
Imaging, Three-Dimensional , Prostatic Neoplasms , Supervised Machine Learning , Humans , Male , Deep Learning , Imaging, Three-Dimensional/methods , Prognosis , Prostatic Neoplasms/pathology , Prostatic Neoplasms/diagnostic imaging , X-Ray Microtomography/methods
11.
J Dent ; 145: 105024, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38670332

ABSTRACT

OBJECTIVE: Rapid maxillary expansion is a common orthodontic procedure to correct maxillary constriction. Assessing the midpalatal suture (MPS) expansion plays a crucial role in treatment planning to determine its effectiveness. The objectives of this preliminary investigation are to demonstrate a proof of concept that the palatal bone underlying the rugae can be clearly imaged by ultrasound (US) and the reconstructed axial view of the US image accurately maps the MPS patency. METHODS: An ex-vivo US scanning was conducted on the upper jawbones of two piglet's carcasses before and after the creation of bone defects, which simulated the suture opening. The planar images were processed to enhance bone intensity distribution before being orderly stacked to fuse into a volume. Graph-cut segmentation was applied to delineate the palatal bone to generate a bone volume. The accuracy of the reconstructed bone volume and the suture opening was validated by the micro-computed tomography (µCT) data used as the ground truth and compared with cone beam computed tomography (CBCT) data as the clinical standard. Also included in the comparison is the rugae thickness. Correlation and Bland-Altman plots were used to test the agreement between the two methods: US versus µCT/CBCT. RESULTS: The reconstruction of the US palatal bone volumes was accurate based on surface topography comparison with a mean error of 0.19 mm for pre-defect and 0.15 mm and 0.09 mm for post-defect models of the two samples, respectively when compared with µCT volumes. A strong correlation (R2 ≥ 0.99) in measuring MPS expansion was found between US and µCT/CBCT with MADs of less than 0.05 mm, 0.11 mm and 0.23 mm for US, µCT and CBCT, respectively. CONCLUSIONS: It was possible to axially image the MPS opening and rugae thickness accurately using high-frequency ultrasound. CLINICAL SIGNIFICANCE: This study introduces an ionizing radiation-free, low-cost, and portable technique to accurately image a difficult part of oral cavity anatomy. The advantages of conceivable visualization could promise a successful clinical examination of MPS to support the predictable treatment outcome of maxillary transverse deficiency.


Subject(s)
Cone-Beam Computed Tomography , Palatal Expansion Technique , Ultrasonography , X-Ray Microtomography , Animals , Swine , X-Ray Microtomography/methods , Cone-Beam Computed Tomography/methods , Palatal Expansion Technique/instrumentation , Ultrasonography/methods , Palate/diagnostic imaging , Palate/anatomy & histology , Cranial Sutures/diagnostic imaging , Cranial Sutures/anatomy & histology , Maxilla/diagnostic imaging , Palate, Hard/diagnostic imaging , Palate, Hard/anatomy & histology , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods
12.
J Indian Prosthodont Soc ; 24(2): 201-207, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38650346

ABSTRACT

AIMS: The objectives of the study were to compare the adaptation of presintered zirconia and cobalt- chromium prostheses using microcomputed tomography (µCT), scanning electron microscopy (SEM), and stereomicroscope (SM). MATERIALS AND METHODS: Twenty-four fixed dental prostheses (FDPs) were fabricated on metal abutments, duplicated from maxillary first premolar and first molar prepared on a typodont model. Teeth were reduced to obtain chamfer of 1.2 mm and reduction occlusaly of 2 mm occlusal. Scanning of the abutments was done with random assignment to two groups receiving the FDPs made from soft-milled Co-Cr (n = 12) and zirconia (n = 12). Marginal and internal gaps were assessed using three evaluation techniques (X-ray microcomputer tomography, SEM, and stereomicroscopy). STATISTICAL ANALYSIS USED: Comparison of the results was made using Levene and analysis of variance tests (α =0.05). RESULTS: Irrespective of the material tested, statistical differences were found between the measuring techniques (P = 0.001 overall); the obtained mean gaps were for CT scan (92.60 ± 13.31), for SEM (101.92 ± 23.03), and for SM (113.44 ± 14.68): the multiple comparisons between techniques found a significant difference between CT and SM (P < 0.001), and SEM and SM (P = 0.025). When materials were compared within each measuring technique, Co-Cr showed lower values compared to zirconia in SEM (P < 0.001) and Stereo (P = 0.049); similar results were found in CT. CONCLUSIONS: Results values differed with the chosen measuring technique. Co-Cr prostheses had a better fit than zirconia prostheses in SEM and Stereo. µCT showed comparable results to SEM, smaller than SM results.


Subject(s)
Chromium Alloys , Microscopy, Electron, Scanning , X-Ray Microtomography , Zirconium , Zirconium/chemistry , X-Ray Microtomography/methods , Chromium Alloys/chemistry , Humans , Dental Prosthesis Design/methods
13.
PLoS One ; 19(4): e0299896, 2024.
Article in English | MEDLINE | ID: mdl-38568900

ABSTRACT

The objective was to evaluate the effect of glide path and coronal flaring on the dentin volume removal and percentage of touched walls in curved canals using two heat-treated rotary files. The mesiobuccal canal of forty-eight, randomly selected, extracted mandibular molars was divided into two groups of 24 each, according to the type of instrument used (RACE EVO and EdgeSequel rotary files). Each group was further divided into three subgroups; Group (A): Control using one file shaped to 04/30, Group (B) with a glide path (EdgeGlidePath (EGP)), and Group (C): with a glide path and coronal flaring (EGP and EdgeTaper Platinum (ETP) SX file respectively). The root canals were then instrumented using the assigned instruments. The assessment was carried out using micro-CT. The comparison of the mean values of the tested groups about dentin volume removal and percentage of untouched walls did not reach statistical significance (p<0.05). Glide path and coronal flaring had an insignificant effect on the dentin volume removal and percentage of untouched walls in curved canals.


Subject(s)
Hot Temperature , Nickel , Root Canal Preparation , X-Ray Microtomography/methods , Root Canal Preparation/methods , Alloys , Titanium , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/surgery , Equipment Design
14.
Am J Physiol Cell Physiol ; 326(6): C1637-C1647, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38646782

ABSTRACT

Bleomycin (BLM)-induced lung injury in mice is a valuable model for investigating the molecular mechanisms that drive inflammation and fibrosis and for evaluating potential therapeutic approaches to treat the disease. Given high variability in the BLM model, it is critical to accurately phenotype the animals in the course of an experiment. In the present study, we aimed to demonstrate the utility of microscopic computed tomography (µCT) imaging combined with an artificial intelligence (AI)-convolutional neural network (CNN)-powered lung segmentation for rapid phenotyping of BLM mice. µCT was performed in freely breathing C57BL/6J mice under isoflurane anesthesia on days 7 and 21 after BLM administration. Terminal invasive lung function measurement and histological assessment of the left lung collagen content were conducted as well. µCT image analysis demonstrated gradual and time-dependent development of lung injury as evident by alterations in the lung density, air-to-tissue volume ratio, and lung aeration in mice treated with BLM. The right and left lung were unequally affected. µCT-derived parameters such as lung density, air-to-tissue volume ratio, and nonaerated lung volume correlated well with the invasive lung function measurement and left lung collagen content. Our study demonstrates the utility of AI-CNN-powered µCT image analysis for rapid and accurate phenotyping of BLM mice in the course of disease development and progression.NEW & NOTEWORTHY Microscopic computed tomography (µCT) imaging combined with an artificial intelligence (AI)-convolutional neural network (CNN)-powered lung segmentation is a rapid and powerful tool for noninvasive phenotyping of bleomycin mice over the course of the disease. This, in turn, allows earlier and more reliable identification of therapeutic effects of new drug candidates, ultimately leading to the reduction of unnecessary procedures in animals in pharmacological research.


Subject(s)
Bleomycin , Lung Injury , Lung , Mice, Inbred C57BL , Neural Networks, Computer , Phenotype , Animals , Bleomycin/toxicity , Lung Injury/chemically induced , Lung Injury/diagnostic imaging , Lung Injury/pathology , Lung Injury/metabolism , Lung/diagnostic imaging , Lung/drug effects , Lung/pathology , Lung/metabolism , Mice , X-Ray Microtomography/methods , Disease Models, Animal , Artificial Intelligence , Male , Pulmonary Fibrosis/chemically induced , Pulmonary Fibrosis/diagnostic imaging , Pulmonary Fibrosis/pathology , Pulmonary Fibrosis/metabolism , Collagen/metabolism
15.
Int J Comput Assist Radiol Surg ; 19(5): 917-927, 2024 May.
Article in English | MEDLINE | ID: mdl-38436923

ABSTRACT

PURPOSE: The small size of the cochlea, and its location deeply embedded in thick temporal bone, poses a challenge for intra-cochlear guidance and diagnostics. Current radiological imaging techniques are not able to visualize the cochlear microstructures in detail. Rotational optical coherence tomography (OCT) fibers show great potential for intra-cochlear guidance. The generated images could be used to map, and study, the tiny cochlear microstructures relevant for hearing. METHODS: This work describes the design of a rotational OCT probe with an outer diameter of 0.9 mm. It further discusses a robotic system, which features a remote center of motion mechanism, dedicated to the probe's positioning, fine manipulation and stable insertion into the cochlear micro-spaces. Furthermore, the necessary calibration steps for 3D reconstruction are described, followed by a detailed quantitative analysis, comparing the 3D reconstructions using a synthetic, 2:1 scaled scala tympani model with a reconstruction from micro-CT, serving as the ground truth. Finally, the potential of the system is demonstrated by scanning a single ex vivo cadaveric human cochlea. RESULTS: The study investigates five insertions in the same 2:1 scaled tympani model, along with their corresponding 3D reconstruction. The comparison with micro-CT results in an average root-mean-square error of 74.2 µm, a signed distance error of 38.1 µm and a standard deviation of 63.6 µm. The average F-score of the reconstructions, using a distance threshold of 100 and 74.2 µm, resulted in 83.0% and 71.8%, respectively. Insertion in the cadaveric human cochlea showed the challenges for straight insertion, i.e., navigating the hook region. CONCLUSION: Overall, the system shows great potential for intra-cochlear guidance and diagnostics, due to the system's capability for precise and stable insertion into the basal turn in the scala tympani. The system, combined with the calibration procedure, results in detailed and precise 3D reconstructions.


Subject(s)
Cochlea , Imaging, Three-Dimensional , Tomography, Optical Coherence , Humans , Imaging, Three-Dimensional/methods , Tomography, Optical Coherence/methods , Cochlea/diagnostic imaging , Cadaver , Robotic Surgical Procedures/methods , Cochlear Implantation/methods , X-Ray Microtomography/methods
16.
Osteoporos Int ; 35(6): 1069-1075, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38520505

ABSTRACT

The aim of this study was to determine whether the Bone Strain Index (BSI), a recent DXA-based bone index, is related to bone mechanical behavior, microarchitecture and finally, to determine whether BSI improves the prediction of bone strength and the predictive role of BMD in clinical practice. PURPOSE: Bone Strain Index (BSI) is a new DXA-based bone index that represents the finite element analysis of the bone deformation under load. The current study aimed to assess whether the BSI is associated with 3D microarchitecture and the mechanical behavior of human lumbar vertebrae. METHODS: Lumbar vertebrae (L3) were harvested fresh from 31 human donors. The anteroposterior BMC (g) and aBMD (g/cm2) of the vertebral body were measured using DXA, and then the BSI was automatically derived. The trabecular bone volume (Tb.BV/TV), trabecular thickness (Tb.Th), degree of anisotropy (DA), and structure model index (SMI) were measured using µCT with a 35-µm isotropic voxel size. Quasi-static uniaxial compressive testing was performed on L3 vertebral bodies under displacement control to assess failure load and stiffness. RESULTS: The BSI was significantly correlated with failure load and stiffness (r = -0.60 and -0.59; p < 0.0001), aBMD and BMC (r = -0.93 and -0.86; p < 0.0001); Tb.BV/TV and SMI (r = -0.58 and 0.51; p = 0.001 and 0.004 respectively). After adjustment for aBMD, the association between BSI and stiffness, BSI and SMI remained significant (r = -0.51; p = 0.004 and r = -0.39; p = 0.03 respectively, partial correlations) and the relation between BSI and failure load was close to significance (r = -0.35; p = 0.06). CONCLUSION: The BSI was significantly correlated with the microarchitecture and mechanical behavior of L3 vertebrae, and these associations remained statistically significant regardless of aBMD.


Subject(s)
Absorptiometry, Photon , Bone Density , Finite Element Analysis , Lumbar Vertebrae , Stress, Mechanical , X-Ray Microtomography , Humans , Lumbar Vertebrae/physiology , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Female , Bone Density/physiology , Aged , Male , Middle Aged , Absorptiometry, Photon/methods , Biomechanical Phenomena/physiology , X-Ray Microtomography/methods , Cancellous Bone/diagnostic imaging , Cancellous Bone/physiology , Weight-Bearing/physiology , Aged, 80 and over , Compressive Strength/physiology , Adult , Anisotropy
17.
Sci Rep ; 14(1): 5831, 2024 03 09.
Article in English | MEDLINE | ID: mdl-38461221

ABSTRACT

Detecting breast tissue alterations is essential for cancer diagnosis. However, inherent bidimensionality limits histological procedures' effectiveness in identifying these changes. Our study applies a 3D virtual histology method based on X-ray phase-contrast microtomography (PhC µ CT), performed at a synchrotron facility, to investigate breast tissue samples including different types of lesions, namely intraductal papilloma, micropapillary intracystic carcinoma, and invasive lobular carcinoma. One-to-one comparisons of X-ray and histological images explore the clinical potential of 3D X-ray virtual histology. Results show that PhC µ CT technique provides high spatial resolution and soft tissue sensitivity, while being non-destructive, not requiring a dedicated sample processing and being compatible with conventional histology. PhC µ CT can enhance the visualization of morphological characteristics such as stromal tissue, fibrovascular core, terminal duct lobular unit, stromal/epithelium interface, basement membrane, and adipocytes. Despite not reaching the (sub) cellular level, the three-dimensionality of PhC µ CT images allows to depict in-depth alterations of the breast tissues, potentially revealing pathologically relevant details missed by a single histological section. Compared to serial sectioning, PhC µ CT allows the virtual investigation of the sample volume along any orientation, possibly guiding the pathologist in the choice of the most suitable cutting plane. Overall, PhC µ CT virtual histology holds great promise as a tool adding to conventional histology for improving efficiency, accessibility, and diagnostic accuracy of pathological evaluation.


Subject(s)
Breast Neoplasms , Humans , Female , X-Rays , Breast Neoplasms/diagnostic imaging , X-Ray Microtomography/methods , Microscopy, Phase-Contrast/methods , Histological Techniques , Imaging, Three-Dimensional/methods
18.
BMC Oral Health ; 24(1): 294, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38431556

ABSTRACT

BACKGROUND: The preparation of the middle mesial (MM) canal of mandibular molars represents a challenge because it is often curved, narrow, and close to the root concave. The purpose of this study was to evaluate the ex vivo shaping ability of 3 nickel-titanium (NiTi) rotary systems in the MM canal using 3D printed resin tooth replicas. METHODS: A permanent mandibular first molar with a MM canal was acquired from a pool of extracted teeth and reproduced by a 3D printer. The resin tooth replicas (n = 18) were equally assigned to 3 groups for the evaluation of the shaping abilities of 3 NiTi rotary systems (OneShape [OS], Twisted Files [TF], and ProTaper Gold [PTG]) according to the manufacturer's recommendations. The tooth replicas were scanned by micro-computed tomography (micro-CT) twice before and after instrumentation of the mesiobuccal (MB), mesiolingual (ML), and MM root canals. After 3D reconstruction, the canal straightening, change of root canal volume and surface area, the mesial and distal canal wall thickness and canal transportation at the levels of 1, 2, and 3 mm below furcation were assessed. One-way variance analysis and Turkey's post hoc test were used for comparisons of the means among different groups, and paired-t test was used to compare the mesial and distal sides of the mesial roots. RESULTS: As compared with OS and TF, the use of PTG in preparation of MM canals resulted in significantly more straightening of canal curvature (p < 0.05), greater post-instrumentation canal volume and surface area, and thinner mesial and distal remaining canal wall thickness at 1, 2 and 3 mm below furcation (all p < 0.05). Regarding the root canal transportation in the mesiodistal direction, there was no significant difference among the 3 instruments (all p > 0.05) after the preparation of the MB and ML canals. However, in the MM canal, more pronounced transportation was detected in the PTG group at 2 mm below furcation, and in the TF group at 3 mm below furcation as compared with the other 2 systems (both p < 0.05). CONCLUSIONS: 3D printed tooth replicas have the advantages of consistency and can be an ideal model to evaluate the shaping ability of different instruments in the MM canal. OS and TF files performed similarly and both are appropriate for shaping the MM canal, while PTG may cause excessive and uneven resin removal, especially near the furcation, and may lead to root fragility and procedural errors.


Subject(s)
Alloys , Dental Pulp Cavity , Nickel , Humans , Dental Pulp Cavity/diagnostic imaging , X-Ray Microtomography/methods , Titanium , Root Canal Preparation , Molar/diagnostic imaging , Molar/surgery , Printing, Three-Dimensional , Equipment Design
19.
Prenat Diagn ; 44(5): 572-579, 2024 May.
Article in English | MEDLINE | ID: mdl-38367004

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of postmortem ultrasound (PMUS), 9.4 T magnetic resonance imaging (MRI) and microfocus computed tomography (micro-CT) for the examination of early gestation fetuses. METHOD: Eight unselected fetuses (10-15 weeks gestational age) underwent at least 2 of the 3 listed imaging examinations. Six fetuses underwent 9.4 T MRI, four underwent micro-CT and six underwent PMUS. All operators were blinded to clinical history. All imaging was reported according to a prespecified template assessing 36 anatomical structures, later grouped into five regions: brain, thorax, heart, abdomen and genito-urinary. RESULTS: More anatomical structures were seen on 9.4 T MRI and micro-CT than with PMUS, with a combined frequency of identified structures of 91.9% and 69.7% versus 54.5% and 59.6 (p < 0.001; p < 0.05) respectively according to comparison groups. In comparison with 9.4 T MRI, more structures were seen on micro-CT (90.2% vs. 83.3%, p < 0.05). Anatomical structures were described as abnormal on PMUS in 2.7%, 9.4 T MRI in 6.1% and micro-CT 7.7% of all structures observed. However, the accuracy test could not be calculated because conventional autopsy was performed on 6 fetuses of that only one structure was abnormal. CONCLUSION: Micro-CT appears to offer the greatest potential as an imaging adjunct or non-invasive alternative for conventional autopsies in early gestation fetuses.


Subject(s)
Autopsy , Fetus , Gestational Age , Magnetic Resonance Imaging , Humans , Female , Pregnancy , Magnetic Resonance Imaging/methods , Autopsy/methods , Fetus/diagnostic imaging , X-Ray Microtomography/methods , Ultrasonography, Prenatal/methods , Adult , Postmortem Imaging
20.
Int Endod J ; 57(6): 700-712, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38404175

ABSTRACT

AIM: To evaluate the influence of different preparation tapers on the reduction in planktonic bacteria and biofilms of Enterococcus faecalis and Candida albicans in the apical third (4 mm) of the mesial roots of mandibular molars, correlating decontamination with canal shape. METHODOLOGY: After microtomography analysis for morphological standardization of the canals, 48 mandibular molar roots, each containing two canals (96 canals), were contaminated with E. faecalis and C. albicans and divided into four groups (n = 11) for canal instrumentation using ProDesign Logic 2 files with different tapers G (.03): # 25.03; G (.04): # 25.04; G (.05): # 25.05; and G (.06): # 25.06 and irrigation with 2.5% sodium hypochlorite. Four roots were examined under a scanning electron microscope (SEM) to qualitatively assess biofilm formation. Eight roots were used as the negative control group (samples were not contaminated). Bacteriological samples were taken exclusively from the apical third of the roots before and after chemical-mechanical preparation and bacterial counts were determined (CFU/mL). The final micro-CT scan was used to quantify the volume variation and unprepared canal area in the apical third. Statistical analysis was performed using the Kruskal-Wallis, Student-Newman-Keuls and Wilcoxon tests for analysis of microbiological data. anova and the Tukey or Games-Howell test were used for analysis of micro-CT data and Spearman's test for correlations (α = 5%). RESULTS: All groups showed a significant reduction in bacteria (p < .05), with no statistically significant difference between groups. There was no significant difference in per cent volume increase between groups. The unprepared area (Δ%) was affected by the file used (p = .026) and was significantly lower for G (.06) compared to G (.03). There was no statistically significant correlation among bacterial reduction, volume and unprepared area (p > .05). CONCLUSION: The different preparation tapers influenced root canal shaping in the apical third but did not improve decontamination in this region.


Subject(s)
Biofilms , Candida albicans , Dental Pulp Cavity , Enterococcus faecalis , Root Canal Preparation , X-Ray Microtomography , X-Ray Microtomography/methods , Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Candida albicans/isolation & purification , Candida albicans/physiology , Dental Pulp Cavity/microbiology , Dental Pulp Cavity/diagnostic imaging , Sodium Hypochlorite/therapeutic use , Sodium Hypochlorite/pharmacology , Microscopy, Electron, Scanning , Molar/microbiology , Plankton , Root Canal Irrigants/administration & dosage , Root Canal Irrigants/therapeutic use , In Vitro Techniques , Tooth Apex/microbiology , Tooth Apex/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...