Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
ASAIO J ; 47(6): 686-91, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11730212

RESUMEN

This study presents an automatic monitoring system for artificial hearts. The self organizing map (SOM) was applied to monitoring and analysis of an aortic pressure (AoP) signal measured from an adult goat equipped with a total artificial heart. In the proposed system, two different SOMs were used to detect and classify abnormalities in the measured AoP signal. In the first stage, an ordinary SOM, taught with only normal AoP data, was used for detection of abnormalities on the basis of the quantization error in the real-time monitoring task. In the second stage, a supervised SOM was used for classification of abnormalities. The supervised SOM can be regarded as an ordinary SOM with an extra class vector for solving the classification problem. The class vector is assigned to every node in the second SOM as an output weight learned according to Kohonen's learning rule. The effectiveness of detection and classification of abnormalities using these two SOMs was confirmed.


Asunto(s)
Corazón Artificial , Monitoreo Fisiológico/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Animales , Aorta/fisiología , Inteligencia Artificial , Presión Sanguínea/fisiología , Monitores de Presión Sanguínea , Sistemas de Computación , Cabras , Diseño de Software
2.
Artif Organs ; 24(8): 644-7, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10971254

RESUMEN

In the clinical usage of the ventricular assist device (VAD), multiple organ failure becomes an important problem. To improve the clinical record of the VAD, another organ function may be vitally important. For that reason, we have been developing a VAD system aiming at improving another organ's function. Development of the vibrating flow pump (VFP), which can generate a very unique flow pattern from 10 Hz to 50 Hz, was ongoing in our Institute. In order to evaluate brain blood flow and oxygen consumption, HbO2 was measured with a NIRO monitoring device in healthy adult goats. Four goats were anesthetized with halothane inhalation; then left thoracotomy was performed for the left heart bypass. HbO2 of the brain was measured by recording of the hemodynamic variables during left heart assistance with the VFP system. During left heart bypass with the VFP system, hemodynamic parameters stayed within normal range, and satisfactory pump output was easily obtained. Pump output stayed within 20-40% bypass to evaluate the effect of high frequency oscillated assist flow on brain blood flow during the same cardiac output. Interesting results were observed during the experiments. During 30 Hz drive of the VFP left heart assistance, HbO2 suggested that brain blood flow significantly increased compared with another drive frequency assistance during the same total cardiac output. These results suggest that we can control the brain blood flow with a totally implantable VAD system such as the VFP system.


Asunto(s)
Circulación Cerebrovascular/fisiología , Corazón Auxiliar , Animales , Encéfalo/metabolismo , Diseño de Equipo , Cabras , Oxígeno/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA