Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Rev Sci Instrum ; 92(1): 013104, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33514227

RESUMEN

This paper details the development of a lab-made experimental setup for surface photovoltage spectroscopy (SPS) measurements using an open-source and Arduino® microcontroller to control a monochromator and some off-the-shelf electronic components. The experimental setup is interfaced to a computer, where LabVIEW® based software manages system control and data acquisition. We also report the design of a compact sample holder, simple and easy to manufacture and handle. Results of the application of SPS to the characterization of MoO3 thin films and semiconductor laser structures are presented to validate the performance of the setup, highlighting the effectiveness of SPS for the characterization of semiconductor materials and devices.

2.
Lasers Med Sci ; 31(7): 1309-16, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27365109

RESUMEN

The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.


Asunto(s)
Implantes Dentales , Láseres de Semiconductores/uso terapéutico , Periimplantitis/radioterapia , Temperatura , Animales , Descontaminación/métodos , Porcinos , Titanio/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...