Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Med Sci Monit ; 30: e943353, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38825814

RESUMEN

BACKGROUND Dentin contamination with hemostatic agents before bonding indirect restorations negatively affects the bond strength. However, the consensus on which materials could be used to clean contamination of hemostatic agents has not been explored. The aim of this study was to assess the effect of Katana Cleaner applied on the surface of dentin contaminated with hemostatic agents on the shear bond strength (SBS) of self-adhesive resin cement by comparing it with three other surface cleaners. MATERIAL AND METHODS Ninety dentin specimens were divided into a no contamination group (control) (n=10), 4 groups contaminated with 25% aluminum chloride (Viscostat Clear) (n=40), and 4 groups contaminated with 20% ferric sulfate (Viscostat) (n=40). Subsequently, 4 different cleaners were used for each contamination group (water rinse, phosphoric acid, chlorhexidine, and Katana Cleaner). Then, self-adhesive resin cement was directly bonded to the treated surfaces. All specimens were subjected to 5000 thermal cycles of artificial aging. The shear bond strength was measured using a universal testing machine. RESULTS Two-way analysis of variance showed that the contaminant type as the main factor was statistically non-significant (p=0.655), cleaner type as the main factor was highly significant (p<0.001), and interaction between the contaminant and cleaner was non-significant (p=0.51). The cleaner type was the main factor influencing the bond strength. Phosphoric acid and chlorhexidine showed better performance than Katana Cleaner. CONCLUSIONS Cleaning dentin surface contamination with phosphoric acid and chlorhexidine had better performance than with Katana Cleaner.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Hemostáticos , Cementos de Resina , Resistencia al Corte , Humanos , Dentina/efectos de los fármacos , Hemostáticos/farmacología , Recubrimiento Dental Adhesivo/métodos , Clorhexidina/análogos & derivados , Clorhexidina/farmacología , Ensayo de Materiales/métodos , Propiedades de Superficie/efectos de los fármacos , Recubrimientos Dentinarios , Compuestos Férricos/química
2.
J Funct Biomater ; 15(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38248684

RESUMEN

Despite considerable improvements in oral health, dental caries remains a public health issue. The most frequently used technique to remove caries is through rotating drills. New minimally invasive strategies were introduced into dental practice, such as the use of lasers to perform highly controlled tissue ablation while limiting pain and discomfort, as well as overcoming drill phobia. The objective was to assess and compare treatment with Er:YAG laser versus a conventional rotary treatment during cavity preparation in children with regard to bond interface quality. In a randomized trial using a split-mouth design, 40 (9-12 year-old) children with 80 carious primary molars were included. The cavity in one quadrant was treated conventionally using a bur, while the cavity in the other quadrant was prepared using an Er:YAG laser. Twenty restored teeth were extracted after one year. The SEM histological evaluation of bond interface results demonstrated no statistically significant differences between restorations placed following bur preparation and those placed following the Er:YAG laser preparation, and both treatments demonstrated promising results. Over a one-year period, no statistically significant differences in the bond interface quality were observed following class I cavity preparation in primary teeth with either Er:YAG laser or a conventional rotary bur.

3.
Orthod Craniofac Res ; 27(3): 447-454, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38153199

RESUMEN

OBJECTIVES: This study aimed to compare the surface roughness and friction of different orthodontic archwires after exposure to salbutamol sulphate inhalation, an anti-asthmatic medication. METHODS: Orthodontic archwires (stainless-steel [StSt], nickel-titanium [NiTi], beta-titanium [ß-Ti], and copper-NiTi [Cu-NiTi]) were equally divided into two groups. The exposed groups were subjected to 20 mg salbutamol sulphate for 21 days and kept in artificial saliva. The control groups were only kept in artificial saliva. Surface changes were visualized using scanning electron microscopy (SEM). The average surface roughness (Ra) was evaluated using atomic force microscopy (AFM), and friction resistance forces were assessed using a universal testing machine. Statistical analyses were performed using t-tests and ANOVA followed by post hoc tests. RESULTS: Salbutamol sulphate did not change the surface roughness of StSt and NiTi archwires (p > .05). However, the change in the surfaces of ß-Ti and Cu-NiTi archwires was significant (p < .001). The frictional forces of exposed StSt, NiTi, and Cu-NiTi archwires did not change (p > .05). However, the frictional forces of ß-Ti archwires increased significantly after exposure to salbutamol sulphate (p = .021). Brushing with fluoride after exposure to salbutamol sulphate increased the frictional forces of ß-Ti only (p = .002). CONCLUSIONS: Salbutamol sulphate inhalation significantly affected the surface texture of ß-Ti and Cu-NiTi orthodontic archwires and increased the friction of ß-Ti archwires. These deteriorating effects were not detected on the surface of StSt and NiTi archwires. Therefore, we suggest that ß-Ti and copper titanium archwires should be used cautiously in individuals under salbutamol sulphate inhalation treatment.


Asunto(s)
Albuterol , Cobre , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Níquel , Alambres para Ortodoncia , Propiedades de Superficie , Titanio , Albuterol/administración & dosificación , Níquel/química , Cobre/química , Titanio/química , Humanos , Antiasmáticos/administración & dosificación , Acero Inoxidable/química , Fricción/efectos de los fármacos , Administración por Inhalación , Ensayo de Materiales , Saliva Artificial/química , Aleaciones Dentales/química
4.
Saudi Dent J ; 35(7): 834-840, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38025604

RESUMEN

Background: Self-adhering composites are claimed to bond to teeth without prior acid etching and bonding steps. This study aimed to evaluate the cyclic shear fatigue (CSF) of metal orthodontic brackets bonded to enamel using self-adhering flowable composites (Constic and VertiseTM Flow) in comparison with that of total-etch and self-etch adhesives. Materials and methods: Twenty-five human premolars comprising 100 surfaces were randomly divided into four groups (n = 25): total-etch, self-etch, Constic, and VertiseTM Flow. A total of 10 surfaces were used per group for baseline static shear bond strength (SSBS) evaluation and 15 surfaces for CSF evaluation. Each tooth was treated with the four bonding agents. Both SSBS and CSF were evaluated using a universal testing machine. For CSF, the staircase method was used with an initial pulling load equivalent to 60% of the SSBS of each group for 1000 cycles or until failure. The adhesive remaining index (ARI) was evaluated for surviving samples using a stereomicroscope. Statistical analysis: A one-way ANOVA with Tukey's post hoc test was used to analyze the CSF data, and a chi-square test was used to analyze the ARI. Results: The total-etch adhesive showed significantly higher CSF values than that of the other groups (p < 0.001). Both total-etch (10.78 ± 0.31 MPa) and self-etch (6.75 ± 0.91 MPa) adhesives showed significantly higher CSF than did Constic (1.94 ± 0.31 MPa) and VertiseTM Flow (2.01 ± 0.25 MPa), (p < 0.001). The ARI indicated that more resin remnants were observed with the total-etch and self-etch adhesives than those with the self-adhering flowable composites. However, no significant differences were observed among groups (p > 0.05). Conclusions: Total-etch and self-etch adhesives showed satisfactory bond strengths for orthodontic treatment. However, Constic and VertiseTM Flow self-adhering flowable composites may not be clinically sufficient for bonding metallic orthodontic brackets to enamel.

5.
Materials (Basel) ; 16(18)2023 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-37763425

RESUMEN

The aim of this study was to investigate the effect of repeated pressing of lithium disilicate ceramic on the shear bond strength (SBS) of three types of resin cement. METHODOLOGY: A lithium disilicate ceramic (IPS e.max® Press) was first heat-pressed to form rectangular disk specimens. Then, leftovers were used for the second and third presses. A total of 90 specimens were prepared and separated, according to the number of pressing cycles, into three groups: 1st, 2nd, and 3rd presses (n = 30). Each group was further subdivided into three groups (n = 10) according to the type of resin cement used, as follows: Multilink N (MN), Variolink Esthetic DC (VDC), and Variolink Esthetic LC (VLC). All the cement was bonded to the ceramic surface, which was etched with hydrofluoric acid and primed with Monobond Plus. All samples were light-cured and stored for 24 h. Shear bond strength was tested on a universal testing machine. RESULTS: A two-way ANOVA was used to evaluate the influence of repeated pressing cycles and cement type as well as their interaction. The results indicated that cement type has a significant impact (p < 0.001) but not the number of pressing cycles (p = 0.970) or their interaction (p = 0.836). The Bonferroni post-hoc test showed that the SBS of MN was significantly higher than that of VDC and VLC in the first press and second press cycles, respectively. The SBS of MN was significantly higher than that of VDC and VLC cements in the third pressing cycle. There was no significant difference in the SBS between VLC and VDC in all three pressing cycles. CONCLUSION: The results of the current study did not report a detrimental effect of repeated pressing up to three cycles on the shear bond strength of the IPS e.max® Press. Multilink resin cement showed the highest SBS to IPS e.max® Press at the third pressing cycle. For all types of cement and heat pressing cycles, the majority of cement failures were adhesive. No cohesive failures occurred in any of the tested resin cements, regardless of the cement type or the number of heat pressing cycles tested.

6.
Materials (Basel) ; 15(4)2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-35207914

RESUMEN

This study aimed to test the biocompatibility and antibacterial properties of Salvadora persica (S. persica) extract, a natural product, as an intracanal medication in comparison with calcium hydroxide (Metapaste, META BIOMED, Cheongju, Korea). The pH values of both materials were tested. The biocompatibility of S. persica extract and Metapaste was determined using light microscopy and MTT assays. The antibacterial action was tested using the zone of bacterial inhibition on four common bacterial species. In addition, intracanal medication was administered using 68 extracted single-rooted teeth contaminated with Enterococcus faecalis (E. faecalis), and the percentage reduction in colony count (% RCC) at 1, 3, and 7 days was measured. The extension of activity for both materials was assessed using histological sections and scanning electron microscopy. S. persica was found to be acidic in nature. Both materials showed significantly lower cell viability than the positive control cells on days 1 and 3 but not on day 7. S. persica showed better antibacterial effects against E. faecalis and S. mutans. S. persica extract showed 97.6%, 98.9%, and 99.3% RCC values at 1, 3, and 7 days, respectively, which are comparable to those of Metapaste. S. persica herbal extract is a promising material that can be utilized as an intracanal medication, but its use requires further research.

7.
BMC Oral Health ; 18(1): 178, 2018 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-30373571

RESUMEN

BACKGROUND: Previous studies had reported that bond strength deteriorate over time following the dentin surface pretreatment with chlorhexidine. Therefore, further investigations are needed to evaluate the effect of other materials such as povidone iodine. The purpose of this study was to investigate the effects of 10% povidone-iodine pretreatment on the resin-dentin micro-tensile bond strength of a single bond adhesive system in permanent teeth over time, and compare it with 2% chlorhexidine. METHODS: Flat dentin surfaces were prepared in 63 extracted permanent teeth. Teeth were randomly assigned to a 10% povidone-iodine pretreatment, a 2% chlorhexidine pretreatment, or a control group. Composite resin blocks were built up over treated surfaces under pulp pressure simulation. The prepared specimens were assigned to three storage time, 24 h, 1 week, and 2 months. Samples were vertically sectioned to obtain specimens of 0.7 to 1.2 mm2 cross-sectional area. RESULTS: No significant reduction of bond strength of povidone iodine group was found among the three storage times (p = 0.477). A significant reduction of bond strength for both chlorhexidine and control groups was found in the three storage times (p <  0.001). CONCLUSION: Povidone iodine pretreatment of etched dentin was effective in reducing the loss of bond strength over time, while the chlorhexidine pretreatment and negative control showed significant deterioration in micro-tensile bond strength over time in permanent teeth.


Asunto(s)
Antiinfecciosos Locales/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Povidona Yodada/química , Grabado Ácido Dental , Bisfenol A Glicidil Metacrilato , Clorhexidina/química , Pulpa Dental/efectos de los fármacos , Fracaso de la Restauración Dental , Dentición Permanente , Humanos , Técnicas In Vitro , Ensayo de Materiales , Arabia Saudita , Propiedades de Superficie , Resistencia a la Tracción
8.
J Dent ; 45: 7-13, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26593780

RESUMEN

OBJECTIVES: The aim of the current study was to evaluate the effect of 2% CHX and 2% CHX-methacrylate compared to the resin-dentin bonds created by a two-step etch-and-rinse adhesive system after 24h, 6min and 12min. METHODS: Microtensile bond strengths and interfacial nanoleakage within resin-dentin interfaces created by Adper Single Bond 2, with or without CHX or CHX-methacrylate pre-treatment for 30s on acid-etched dentin surfaces, were evaluated after 24h, 6min and 12min of storage in distilled water at 37°C. RESULTS: Twelve months of storage resulted in a significant decrease in microtensile bond strength in the control group, and significant increases in silver nanoleakage. In contrast, Single Bond 2+CHX, and to a greater extent CHX-methacrylate, significantly reduced the rate of deterioration of resin-dentin interfaces over the 12min water storage period, in terms of bond strength. CONCLUSIONS: Similar to Single Bond 2+CHX, Single Bond+CHX-methacrylates reduced the degradation of resin-bonded interfaces over a 12 month storage period. Thus it can be concluded that Single Bond 2+CHX-methacrylate may be important to improve durability of bonded interfaces and therefore, prolong the life span of adhesive restorations. CLINICAL SIGNIFICANCE: Although CHX primers have been shown to enhance the durability of etch-and-rinse adhesives, that protection is lost after 2h. The use of CHX-methacrylate should last much longer since it may copolymerize with adhesive monomers, unlike CHX.


Asunto(s)
Antiinfecciosos Locales/farmacología , Clorhexidina/análogos & derivados , Materiales Dentales/química , Metacrilatos/química , Resinas Sintéticas/química , Grabado Ácido Dental/métodos , Bisfenol A Glicidil Metacrilato/química , Clorhexidina/química , Recubrimiento Dental Adhesivo , Cementos Dentales/química , Filtración Dental , Análisis del Estrés Dental , Dentina/efectos de los fármacos , Recubrimientos Dentinarios/química , Humanos , Tercer Molar , Propiedades de Superficie
9.
Dent Mater ; 31(3): 205-16, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25612786

RESUMEN

OBJECTIVE: This work measured the amount of bound versus unbound water in completely-demineralized dentin. METHODS: Dentin beams prepared from extracted human teeth were completely demineralized, rinsed and dried to constant mass. They were rehydrated in 41% relative humidity (RH), while gravimetrically measuring their mass increase until the first plateau was reached at 0.064 (vacuum) or 0.116 gH2O/g dry mass (Drierite). The specimens were then exposed to 60% RH until attaining the second plateau at 0.220 (vacuum) or 0.191 gH2O/g dry mass (Drierite), and subsequently exposed to 99% RH until attaining the third plateau at 0.493 (vacuum) or 0.401 gH2O/g dry mass (Drierite). RESULTS: Exposure of the first layer of bound water to 0% RH for 5 min produced a -0.3% loss of bound water; in the second layer of bound water it caused a -3.3% loss of bound water; in the third layer it caused a -6% loss of bound water. Immersion in 100% ethanol or acetone for 5 min produced a 2.8 and 1.9% loss of bound water from the first layer, respectively; it caused a -4 and -7% loss of bound water in the second layer, respectively; and a -17 and -23% loss of bound water in the third layer. Bound water represented 21-25% of total dentin water. Chemical dehydration of water-saturated dentin with ethanol/acetone for 1 min only removed between 25 and 35% of unbound water, respectively. SIGNIFICANCE: Attempts to remove bound water by evaporation were not very successful. Chemical dehydration with 100% acetone was more successful than 100% ethanol especially the third layer of bound water. Since unbound water represents between 75 and 79% of total matrix water, the more such water can be removed, the more resin can be infiltrated.


Asunto(s)
Dentina/química , Agua/química , Acetona/química , Grabado Ácido Dental , Adsorción , Bisfenol A Glicidil Metacrilato/química , Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios/química , Desecación/métodos , Etanol/química , Humanos , Técnicas In Vitro , Ensayo de Materiales , Tercer Molar , Cementos de Resina/química , Solventes/química , Desmineralización Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA