Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Neurosurg ; : 1-10, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39213673

RESUMEN

OBJECTIVE: Certain patients must undergo frequent postoperative digital subtraction angiography (DSA) after flow diversion (FD) therapy. No imaging modality with an efficacy comparable to that of DSA has been established. This study was conducted to determine the efficacy of contrast-enhanced delay alternating with nutation for tailored excitation (DANTE) T1-sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE), a high-resolution vessel wall magnetic resonance imaging technique for evaluating the occlusion status of intracranial aneurysms after FD treatment, with DSA serving as the reference standard. METHODS: This retrospective study included 23 patients with 26 aneurysms who had undergone FD treatment between April 2016 and May 2022. Contrast-enhanced DANTE T1-SPACE and DSA were performed as postoperative follow-up imaging studies at 45 time points, both in the same period. The agreement rates for aneurysm occlusion status in the 45 imaging studies were examined. RESULTS: Contrast-enhanced DANTE T1-SPACE had a sensitivity and specificity of 96.3% (26/27) and 83.3% (15/18), respectively, for detecting aneurysm remnants. Overall, 91.1% (41/45) of findings detected on contrast-enhanced DANTE T1-SPACE were consistent with those on DSA. The findings detected on contrast-enhanced DANTE T1-SPACE were completely consistent with those of intraaneurysmal residual blood flow identified on DSA or high-resolution cone-beam computed tomography images in 74.1% (20/27) of the examinations that showed incomplete occlusion on DSA. Furthermore, parent artery status after FD treatment on contrast-enhanced DANTE T1-SPACE was consistent with that observed on DSA in 97.8% (44/45) of examinations. CONCLUSIONS: Contrast-enhanced DANTE T1-SPACE is a very useful option in the follow-up of aneurysms after FD treatment.

2.
J Neurosurg Case Lessons ; 8(8)2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39159493

RESUMEN

BACKGROUND: Spinal epidural arteriovenous fistulas (SEAVFs) with intraosseous shunts are rare, and their underlying pathophysiological mechanisms remain unclear. OBSERVATIONS: A female in her 70s presented with rapidly progressive weakness in both lower extremities and urinary retention. Lumbar spine magnetic resonance imaging revealed spinal cord edema and flow voids due to venous dilation and compression fractures of the L1 and L2 vertebral bodies. Spinal angiography revealed ventral and dorsal somatic branches of the lumbar arteries at L1 and L2 flowing into the shunt. High-resolution cone-beam computed tomography revealed a shunt within the compression-fractured vertebral body bone of L2. The intravertebral shunt blood flowed into the ventral epidural venous plexus (VEVP) and returned into the perimedullary vein (PMV). Transarterial embolization was performed using N-butyl cyanoacrylate and Onyx-18 for feeder L1 and feeder L2, respectively. Onyx-18 was injected from the VEVP into the PMV, and complete occlusion of the shunt was achieved. The patient showed symptomatic improvement postoperatively. LESSONS: Vertebral compression fractures are common but rarely associated with SEAVFs. https://thejns.org/doi/10.3171/CASE2457.

3.
BMC Cancer ; 24(1): 128, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267924

RESUMEN

BACKGROUND: Sarcopenia has been identified as a potential negative prognostic factor in cancer patients. In this study, our objective was to investigate the relationship between the assessment method for sarcopenia using the masseter muscle volume measured on computed tomography (CT) images and the life expectancy of patients with oral cancer. We also developed a learning model using deep learning to automatically extract the masseter muscle volume and investigated its association with the life expectancy of oral cancer patients. METHODS: To develop the learning model for masseter muscle volume, we used manually extracted data from CT images of 277 patients. We established the association between manually extracted masseter muscle volume and the life expectancy of oral cancer patients. Additionally, we compared the correlation between the groups of manual and automatic extraction in the masseter muscle volume learning model. RESULTS: Our findings revealed a significant association between manually extracted masseter muscle volume on CT images and the life expectancy of patients with oral cancer. Notably, the manual and automatic extraction groups in the masseter muscle volume learning model showed a high correlation. Furthermore, the masseter muscle volume automatically extracted using the developed learning model exhibited a strong association with life expectancy. CONCLUSIONS: The sarcopenia assessment method is useful for predicting the life expectancy of patients with oral cancer. In the future, it is crucial to validate and analyze various factors within the oral surgery field, extending beyond cancer patients.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Boca , Sarcopenia , Humanos , Pronóstico , Músculo Masetero/diagnóstico por imagen , Sarcopenia/diagnóstico por imagen , Neoplasias de la Boca/diagnóstico por imagen
4.
Neuroradiol J ; : 19714009231224420, 2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38148669

RESUMEN

The safety and feasibility of using staged flow diverter (FD) for ruptured cerebral aneurysms, in which coil embolization is performed in the acute phase and FD is deployed in the subacute phase, has recently been reported. This strategy requires assuming the rupture point and performing coil embolization. Although vessel wall magnetic resonance imaging (VW-MRI) has been reported to be useful in predicting the rupture point of aneurysms, its use with staged FD has not yet been reported. We report the first case of staged FD with preoperative contrast-enhanced VW-MRI to predict the rupture point for partially thrombosed vertebral artery dissecting large aneurysm involving posterior inferior cerebellar artery (PICA) origin. This approach achieved a very good outcome, not only completely occluding the aneurysm, but also reconstructing the parent artery while maintaining the patency of the PICA.

5.
J Neurosurg Case Lessons ; 6(14)2023 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-37782963

RESUMEN

BACKGROUND: The effect of vessel wall magnetic resonance imaging (VW-MRI) enhancement in partially thrombosed aneurysms has previously indicated aneurysmal instability and a rupture risk. However, whether the contrast effect of the wall changes before or after flow diversion treatment is still under investigation. OBSERVATIONS: The authors report a case of a partially thrombosed basilar artery aneurysm that increased in size over a short period, worsened brainstem compression symptoms, and was treated with a flow diverter stent with good results. In this case, VW-MRI after surgery showed a reduced contrast effect on the intraluminal thrombus within the aneurysm. The aneurysm thrombosed and markedly regressed over the next 5 months, with remarkable improvement in the brainstem compression symptoms. LESSONS: This finding on VW-MRI may indicate an attenuation of neovascularization in the thrombus wall and be a sign of aneurysm stabilization.

6.
Stroke ; 54(6): 1627-1635, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37139818

RESUMEN

BACKGROUND: Permanent metallic flow diverter (FD) implantation for treatment of intracranial aneurysms requires antiplatelet therapy for an unclear duration and restricts postprocedural endovascular access. Bioresorbable FDs are being developed as a solution to these issues, but the biological reactions and phenomena induced by bioresorbable FDs have not been compared with those of metallic FDs. METHODS: We have developed a bioresorbable poly (L-lactic acid) FD (PLLA-FD) and compared it with an FD composed of cobalt-chromium and platinum-tungsten (CoCr-FD). FD mechanical performance and in vitro degradation of the PLLA-FD were evaluated. For in vivo testing in a rabbit aneurysm model, FDs were implanted at the aneurysm site and the abdominal aorta in the PLLA-FD group (n=21) and CoCr-FD group (n=15). Aneurysm occlusion rate, branch patency, and thrombus formation within the FD were evaluated at 3, 6, and 12 months. Local inflammation and neointima structure were also evaluated. RESULTS: Mean strut, porosity, and pore density for the PLLA-FD were 41.7 µm, 60%, and 20 pores per mm2, respectively. The proportion of aneurysms exhibiting a neck remnant or complete occlusion did not significantly differ between the groups; however, the complete occlusion rate was significantly higher in the PLLA-FD group (48% versus 13%; P=0.0399). Branch occlusion and thrombus formation within the FD were not observed in either group. In the PLLA-FD group, CD68 immunoreactivity was significantly higher, but neointimal thickness decreased over time and did not significantly differ from that of the CoCr-FD at 12 months. Collagen fibers significantly predominated over elastic fibers in the neointima in the PLLA-FD group. The opposite was observed in the CoCr-FD group. CONCLUSIONS: The PLLA-FD was as effective as the CoCr-FD in this study and is feasible for aneurysm treatment. No morphological or pathological problems were observed with PLLA-FD over a 1-year period.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal , Enfermedades Vasculares , Animales , Conejos , Implantes Absorbibles , Cromo , Cobalto , Neointima , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Ácido Láctico , Stents , Resultado del Tratamiento
7.
J Neurointerv Surg ; 15(9): 886-891, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35853697

RESUMEN

BACKGROUND: Although flow diversion plays a pivotal role in treating internal carotid artery aneurysms presenting with cranial neuropathy, predictors of symptom improvement have not been established. OBJECTIVE: To investigate improvement of symptoms after flow diversion treatment in patients with internal carotid artery aneurysms causing cranial neuropathy, with sufficient follow-up period. Additionally, to examine factors associated with improvement of symptoms. METHODS: This retrospective multicenter study examined patients with unruptured internal carotid artery aneurysms presenting with cranial neuropathy who were treated using flow diversion and followed up for at least 12 months. Study outcomes were transient worsening of symptoms and symptom status 12 months after treatment. Patient and aneurysm characteristics were statistically analyzed. RESULTS: Seventy-seven patients were included. Data needed for outcome analysis were available for 66 patients. At the 1-, 3-, 6-, 12-month, and last follow-ups, the proportion of patients with resolved or improved symptoms was 26% (20/77), 51% (39/77), 74% (57/77), 83% (64/77), and 79%(62/77), respectively. Symptom onset-to-treatment time <6 months (OR=24.2; 95% CI 3.09 to 188.84; p=0.002) and aneurysmal regression (OR=23.1; 95% CI 1.97 to 271.75; p=0.012) were significantly associated with symptom improvement. Transient symptom worsening and worse symptoms at 12 months occurred in 19/77 (25%) and 2/77 (3%) patients, respectively. CONCLUSIONS: The rate of cranial neuropathy symptom improvement after flow diversion increased over the first 12 months after treatment, but not thereafter. Treatment within 6 months of symptom onset and aneurysmal regression were predictors of symptom improvement.


Asunto(s)
Enfermedades de las Arterias Carótidas , Enfermedades de los Nervios Craneales , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Resultado del Tratamiento , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/cirugía , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Embolización Terapéutica/efectos adversos , Enfermedades de los Nervios Craneales/etiología , Enfermedades de las Arterias Carótidas/complicaciones , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Stents/efectos adversos
8.
J Clin Med ; 13(1)2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38202143

RESUMEN

The diagnosis of oral mucosal diseases is a significant challenge due to their diverse differential characteristics. Risk assessment of lesions by visual examination is a complex process due to the lack of definitive guidelines. This study aimed to improve this process by creating a diagnostic algorithm using gaze data acquired during oral mucosal disease examinations. A total of 78 dentists were included in this study. Tobii Pro Nano® (Tobii Technology) was used to acquire gaze data during clinical photographic visual examinations. Advanced analysis tools such as support vector machines and heatmaps were used to visualize the gazing tendencies of a group of skilled oral surgeons, focusing on the number of gazes per region and the gazing time ratios. The preliminary findings showed the possibility of visualizing gazing tendencies and identifying areas of importance for diagnosis. The classification of intraoral photographs based on gross features revealed the existence of an optimal examination method for each category and diagnostically significant areas. This novel approach to analyzing gaze data has the potential to refine diagnostic techniques and increase both accuracy and efficiency.

9.
Front Neurol ; 14: 1266460, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38187156

RESUMEN

Background and purpose: Although aneurysm shrinkage often occurs after flow diversion treatment for intracranial aneurysms, no reports have addressed the factors associated with aneurysm shrinkage. Materials and methods: This retrospective single-center study was performed to examine patients with unruptured internal carotid artery aneurysms who were treated using flow diversion and followed up by imaging for at least 12 months. The study outcome was aneurysm shrinkage (volume reduction of ≥10%) 12 months after treatment. Aneurysm volume was quantitatively assessed using the MRIcroGL software. Patient and aneurysm characteristics were statistically analyzed. Results: This study involved 81 patients with 88 aneurysms. At the 6 months, 12 months, and last follow-ups, the proportion of aneurysms that had shrunk was 50, 64, and 65%, respectively. No adjunctive coiling (odds ratio, 56.7; 95% confidence interval, 7.03-457.21; p < 0.001) and aneurysm occlusion (odds ratio, 90.7; 95% confidence interval, 8.32-988.66; p < 0.001) were significantly associated with aneurysm shrinkage. In patients treated by flow diversion with adjunctive coiling, only the volume embolization rate was a factor significantly associated with aneurysm shrinkage (p < 0.001). Its cutoff value was 15.5% according to the receiver operating characteristic curve analysis (area under the curve, 0.87; sensitivity, 0.87; specificity, 0.83). Conclusion: The rate of aneurysm shrinkage after flow diversion increased during the first 12 months after treatment, but not thereafter. No adjunctive coiling and aneurysm occlusion were predictors of aneurysm shrinkage, respectively. If adjunctive coiling is required, a volume embolization rate of ≤15.5% may be suggested for aneurysm regression.

10.
Phys Chem Chem Phys ; 24(47): 28782-28787, 2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36382471

RESUMEN

Controlling the patterns formed by self-propelled particles through dynamic self-organization is a challenging task. Although varieties of patterns associated with chiral self-propelled particles have been reported, essential factors that determine the morphology of the patterns have remained unclear. Here, we explore theoretically how torque formed upon collision of the particles affects the dynamic self-organization of the particles and determine the patterns. Based on a particle-based model with collision-induced torque and torque associated with self-propulsion, we find that introducing collision-induced torque turns the homogeneous bi-directionally aligned particles into rotating mono-polar flocks, which helps resolve a discrepancy in the earlier observations in microfilament gliding assays.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA