RESUMEN
OBJECTIVES: Obtaining a definitive pathological diagnosis from brain tissue sampling was challenging due to the small, non-representative sample. This study introduced a novel syringe technique for brain biopsy aimed at enhancing diagnostic accuracy by obtaining core tissue samples that better represent the targeted tissue. METHODS: The ten patients with atypical brain lesions underwent the syringe biopsy. After meticulous preoperative planning with neuronavigation, a minimally invasive approach was used: a 3 cm skin incision and a 14 mm burr hole were created. A modified 3-cc syringe was used to create negative pressure and cannulate the brain tissue. The desired sample size (24 cm³) was obtained by controlling the syringe depth and withdrawal. Medical records were reviewed to assess sample analysis results and any complications RESULTS: The syringe technique successfully yielded adequate tissue samples in 9 out of 10 patients. In one case, the desired tissue could not be retrieved and required a microsurgical approach for removal. In all ten cases, a correct diagnosis was made without significant complications. CONCLUSION: The preliminary findings suggest that the syringe technique is both safe and effective for obtaining substantial volumes of brain tissue, facilitating accurate pathological evaluation in cases of complex neurological disorders.