Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; PP2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39146168

RESUMEN

Accelerated MRI protocols routinely involve a predefined sampling pattern that undersamples the k-space. Finding an optimal pattern can enhance the reconstruction quality, however this optimization is a challenging task. To address this challenge, we introduce a novel deep learning framework, AutoSamp, based on variational information maximization that enables joint optimization of sampling pattern and reconstruction of MRI scans. We represent the encoder as a non-uniform Fast Fourier Transform that allows continuous optimization of k-space sample locations on a non-Cartesian plane, and the decoder as a deep reconstruction network. Experiments on public 3D acquired MRI datasets show improved reconstruction quality of the proposed AutoSamp method over the prevailing variable density and variable density Poisson disc sampling for both compressed sensing and deep learning reconstructions. We demonstrate that our data-driven sampling optimization method achieves 4.4dB, 2.0dB, 0.75dB, 0.7dB PSNR improvements over reconstruction with Poisson Disc masks for acceleration factors of R = 5, 10, 15, 25, respectively. Prospectively accelerated acquisitions with 3D FSE sequences using our optimized sampling patterns exhibit improved image quality and sharpness. Furthermore, we analyze the characteristics of the learned sampling patterns with respect to changes in acceleration factor, measurement noise, underlying anatomy, and coil sensitivities. We show that all these factors contribute to the optimization result by affecting the sampling density, k-space coverage and point spread functions of the learned sampling patterns.

2.
Bioengineering (Basel) ; 10(3)2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36978725

RESUMEN

Cardiac magnetic resonance (CMR) is an essential clinical tool for the assessment of cardiovascular disease. Deep learning (DL) has recently revolutionized the field through image reconstruction techniques that allow unprecedented data undersampling rates. These fast acquisitions have the potential to considerably impact the diagnosis and treatment of cardiovascular disease. Herein, we provide a comprehensive review of DL-based reconstruction methods for CMR. We place special emphasis on state-of-the-art unrolled networks, which are heavily based on a conventional image reconstruction framework. We review the main DL-based methods and connect them to the relevant conventional reconstruction theory. Next, we review several methods developed to tackle specific challenges that arise from the characteristics of CMR data. Then, we focus on DL-based methods developed for specific CMR applications, including flow imaging, late gadolinium enhancement, and quantitative tissue characterization. Finally, we discuss the pitfalls and future outlook of DL-based reconstructions in CMR, focusing on the robustness, interpretability, clinical deployment, and potential for new methods.

3.
Magn Reson Med ; 88(3): 1263-1272, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35426470

RESUMEN

PURPOSE: Deep learning (DL) based reconstruction using unrolled neural networks has shown great potential in accelerating MRI. However, one of the major drawbacks is the loss of high-frequency details and textures in the output. The purpose of the study is to propose a novel refinement method that uses null-space kernel to refine k-space and improve blurred image details and textures. METHODS: The proposed method constrains the output of the DL to comply to the linear neighborhood relationship calibrated in the auto-calibration lines. To demonstrate efficacy, we tested our refinement method on the DL reconstruction under a variety of conditions (i.e., dataset, unrolled neural networks, and under-sampling scheme). Specifically, the method was tested on three large-scale public datasets (knee and brain) from fastMRI's multi-coil track. RESULTS: The proposed scheme visually reduces the structural error in the k-space domain, enhance the homogeneity of the k-space intensity. Consequently, reconstructed image shows sharper images with enhanced details and textures. The proposed method is also successful in improving high-frequency image details (SSIM, GMSD) without sacrificing overall image error (PSNR). CONCLUSION: Our findings imply that refining DL output using the proposed method may generally improve DL reconstruction as tested with various large-scale dataset and networks.


Asunto(s)
Aprendizaje Profundo , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación
4.
Radiol Clin North Am ; 59(6): 967-985, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34689881

RESUMEN

Machine learning (ML) and Artificial intelligence (AI) has the potential to dramatically improve radiology practice at multiple stages of the imaging pipeline. Most of the attention has been garnered by applications focused on improving the end of the pipeline: image interpretation. However, this article reviews how AI/ML can be applied to improve upstream components of the imaging pipeline, including exam modality selection, hardware design, exam protocol selection, data acquisition, image reconstruction, and image processing. A breadth of applications and their potential for impact is shown across multiple imaging modalities, including ultrasound, computed tomography, and MRI.


Asunto(s)
Diagnóstico por Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Radiología/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA