Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 15(22)2022 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-36431654

RESUMEN

Gaseous pollutants such as hydrogen gas (H2) are emitted in daily human activities. They have been massively studied owing to their high explosivity and widespread usage in many domains. The current research is designed to analyse optical fiber-based H2 gas sensors by incorporating palladium/graphene oxide (Pd/GO) nanocomposite coating as sensing layers. The fabricated multimode silica fiber (MMF) sensors were used as a transducing platform. The tapering process is essential to improve the sensitivity to the environment through the interaction of the evanescent field over the area of the tapered surface area. Several characterization methods including FESEM, EDX, AFM, and XRD were adopted to examine the structure properties of the materials and achieve more understandable facts about their functional performance of the optical sensor. Characterisation results demonstrated structures with a higher surface for analyte gas reaction to the optical sensor performance. Results indicated an observed increment in the Pd/GO nanocomposite-based sensor responses subjected to the H2 concentrations increased from 0.125% to 2.00%. The achieved sensitivities were 33.22/vol% with a response time of 48 s and recovery time of 7 min. The developed optical fiber sensors achieved excellent selectivity and stability toward H2 gas upon exposure to other gases such as ammonia and methane.

2.
Sensors (Basel) ; 21(2)2021 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-33466822

RESUMEN

Ammonia detection in ambient air is critical, given its implication on the environment and human health. In this work, an optical fiber tapered to a 20 µm diameter and coated with graphene oxide was developed for absorbance response monitoring of ammonia at visible (500-700 nm) and near-infrared wavelength regions (700-900 nm). The morphology, surface characteristics, and chemical composition of the graphene oxide samples were confirmed by a field emission scanning electron microscope, an atomic force microscope, X-ray diffraction, and an energy dispersion X-ray. The sensing performance of the graphene oxide-coated optical microfiber sensor towards ammonia at room temperature revealed better absorbance response at the near-infrared wavelength region compared to the visible region. The sensitivity, response and recovery times at the near-infrared wavelength region were 61.78 AU/%, 385 s, and 288 s, respectively. The sensitivity, response and recovery times at the visible wavelength region were 26.99 AU/%, 497 s, and 192 s, respectively. The selectivity of the sensor towards ammonia was affirmed with no response towards other gases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA