Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Public Health ; 12: 1388783, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38903588

RESUMEN

Background: Although data on outdoor gamma radiation are available for many countries, they have generally been obtained with measurements performed in undisturbed environments instead of in urban areas where most of the population lives. Only one large national survey, with on-site measurements in urban areas, has been identified worldwide, probably due to high costs (e.g., personnel and instrumentation) and difficulties in selecting measuring points. Methods: A campaign of outdoor gamma radiation measurements has been carried out in the entire Italian territory. All measurement points were selected at the infrastructures of an Italian telecommunications company as representatives of all the possible situations of outdoor exposure to gamma radiation for population in urban areas. Ten replicates of portable gamma (X) detectors carried out all the measurements. Results: Approximately 4,000 measurements have been performed. They are distributed across 2,901 Italian municipalities, accounting for 75% of the Italian population. The national population-weighted mean of the gamma ambient dose equivalent rate (ADER) is 117 nSv h-1, and it ranges from 62 to 208 nSv h-1 and from 40 to 227 nSv h-1 for 21 regions and 107 provinces, respectively. The average variability at the municipal level, in terms of the coefficient of variation (CV) is 21%, ranging from 3 to 84%. The impact of land coverage and the distance from a building on the outdoor gamma radiation level was assessed with complementary measurements, leading to differences ranging from -40 to 50% and to 50%, respectively. Conclusion: A representative campaign of outdoor gamma dose rate measurements has been performed in Italy, only in urban areas, to assess the exposure effect due to outdoor gamma radiation on the population. It is the largest national campaign in urban areas worldwide, with a total of 3,876 on-site measurements. The land coverage and the distance from surrounding buildings were recognized to strongly affect outdoor gamma radiation levels, leading to high variability within small areas. The collaboration with a company that owns a network of facilities on a national territory as dense as the residing population made this survey feasible and affordable. Other countries might adopt this methodology to conduct national surveys in urban environments.


Asunto(s)
Rayos gamma , Italia , Humanos , Población Urbana/estadística & datos numéricos , Exposición a la Radiación/estadística & datos numéricos , Monitoreo de Radiación , Exposición a Riesgos Ambientales/estadística & datos numéricos
2.
Artículo en Inglés | MEDLINE | ID: mdl-35206618

RESUMEN

The performance of continuous radon monitors (CRMs) is usually evaluated under controlled conditions in a radon chamber during calibrations or intercomparison exercises. The impact of thoron on CRMs response is rarely evaluated; in case the evaluation is performed, it is carried out in a controlled atmosphere with relatively constant, homogeneous, and generally high thoron concentrations and very low radon levels. In a real indoor environment, both radon and thoron concentrations are extremely variable, so the thoron interference evaluations reported in the literature are generally not applicable to CRMs used to measure radon concentration indoors. For this reason, an experimental study was carried out with four different CRMs in an indoor environment (an office room) where medium-to-high concentrations of both radon and thoron were expected. Thoron concentration has been separately evaluated throughout two different active monitors. Three CRMs resulted in overestimations of radon concentration by about 10% due to thoron interference, whereas such interference results were negligible for the fourth CRM. However, the thoron interference can also be used to assess thoron concentration by using CRM not specifically designed to do so. Based on the results of this study, an indirect method to assess thoron concentration is indeed proposed, relying on the combination of two identical monitors (one placed right close to the wall and the other one far enough from there).


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Monitoreo de Radiación , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Vivienda , Monitoreo de Radiación/métodos , Radón/análisis , Hijas del Radón/análisis
3.
Foods ; 10(7)2021 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-34199014

RESUMEN

A comprehensive study into the potential of bioprocessing techniques (sprouting and sourdough fermentation) for improving the technological and nutritional properties of wheat breads produced using barley and lentil grains was undertaken. Dextran biosynthesis in situ during fermentation of native or sprouted barley flour (B or SB) alone or by mixing SB flour with native or sprouted lentil flour (SB-L or SB-SL) by Weissella paramesenteroides SLA5, Weissella confusa SLA4, Leuconostoc pseudomesenteroides DSM 20193 or Weissella confusa DSM 20194 was assessed. The acidification and the viscosity increase during 24 h of fermentation with and without 16% sucrose (on flour weight), to promote the dextran synthesis, were followed. After the selection of the fermentation parameters, the bioprocessing was carried out by using Leuconostoc pseudomesenteroides DSM 20193 (the best LAB dextran producer, up to 2.7% of flour weight) and a mixture of SB-SL (30:70% w/w) grains, enabling also the decrease in the raffinose family oligosaccharides. Then, the SB-SL sourdoughs containing dextran or control were mixed with the wheat flour (30% of the final dough) and leavened with baker's yeast before baking. The use of dextran-containing sourdough allowed the production of bread with structural improvements, compared to the control sourdough bread. Compared to a baker's yeast bread, it also markedly reduced the predicted glycemic index, increased the soluble (1.26% of dry matter) and total fibers (3.76% of dry matter) content, giving peculiar and appreciable sensory attributes.

4.
Food Chem ; 355: 129638, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33799242

RESUMEN

Exopolysaccharides produced in situ by lactic acid bacteria during sourdough fermentation are recognized as bread texture improvers. In this study, the suitability of whole and sprouted lentil flours, added with 25% on flour weight sucrose for dextran formation by selected strains during sourdough fermentation, was evaluated. The dextran synthesized in situ by Weissella confusa SLA4 was 9.2 and 9.7% w/w flour weight in lentil and sprouted lentil sourdoughs, respectively. Wheat bread supplemented with 30% w/w sourdough showed increased specific volume and decreased crumb hardness and staling rate, compared to the control wheat bread. Incorporation of sourdoughs improved the nutritional value of wheat bread, leading to increased total and soluble fibers content, and the aroma profile. The integrated biotechnological approach, based on sourdough fermentation and germination, is a potential clean-label strategy to obtain high-fibers content foods with tailored texture, and it can further enhance the use of legumes in novel foods.


Asunto(s)
Pan/microbiología , Dextranos/metabolismo , Fermentación , Harina/microbiología , Lens (Planta)/química , Weissella/metabolismo , Pan/análisis , Harina/análisis , Microbiología de Alimentos , Lens (Planta)/microbiología , Valor Nutritivo , Sacarosa/metabolismo
5.
Sci Total Environ ; 762: 144150, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33418274

RESUMEN

Uncertainty on long-term average radon concentration has a large impact on lung cancer risk assessment in epidemiological studies. The uncertainty can be estimated by year-to-year radon concentration variability, however few data are available. In Italy a study has been planned and conducted to evaluate year-to-year radon variability over several years in normally inhabited dwellings, mainly located in Rome. This is the longest study of this kind in Europe; repeat radon measurements are carried out for 10 years using LR-115 radon detectors in the same home in consecutive years. The study includes 84 dwellings with long-term average radon concentration ranging from 28 to 636 Bq/m3. The result shows that year-to-year variability of repeated measurements made in the same home in different years is low, with an overall coefficient of variation of 17%. This is smaller than most of those observed in studies from other European countries and USA, ranging from 15% to 62%. Influencing factors that may explain the differences between this study and other studies have been discussed. Due to the low yearly variability estimated in the present 10-year study, a negligible impact on lung cancer risk estimate for the Italian epidemiological study is expected.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Neoplasias Pulmonares , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Europa (Continente)/epidemiología , Estudios de Seguimiento , Vivienda , Humanos , Italia/epidemiología , Neoplasias Pulmonares/epidemiología , Radón/análisis , Ciudad de Roma
6.
Front Public Health ; 8: 611146, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33365298

RESUMEN

Scientific community and institutions (e. g., ICRP) consider that the Linear No-Threshold (LNT) model, which extrapolates stochastic risk at low dose/low dose rate from the risk at moderate/high doses, provides a prudent basis for practical purposes of radiological protection. However, biological low dose/dose rate responses that challenge the LNT model have been highlighted and important dowels came from radiobiology studies conducted in Deep Underground Laboratories (DULs). These extreme ultra-low radiation environments are ideal locations to conduct below-background radiobiology experiments, interesting from basic and applied science. The INFN Gran Sasso National Laboratory (LNGS) (Italy) is the site where most of the underground radiobiological data has been collected so far and where the first in vivo underground experiment was carried out using Drosophila melanogaster as model organism. Presently, many DULs around the world have implemented dedicated programs, meetings and proposals. The general message coming from studies conducted in DULs using protozoan, bacteria, mammalian cells and organisms (flies, worms, fishes) is that environmental radiation may trigger biological mechanisms that can increase the capability to cope against stress. However, several issues are still open, among them: the role of the quality of the radiation spectrum in modulating the biological response, the dependence on the biological endpoint and on the model system considered, the overall effect at organism level (detrimental or beneficial). At LNGS, we recently launched the RENOIR experiment aimed at improving knowledge on the environmental radiation spectrum and to investigate the specific role of the gamma component on the biological response of Drosophila melanogaster.


Asunto(s)
Laboratorios , Protección Radiológica , Animales , Drosophila melanogaster , Italia , Radiobiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...