1.
Curr Cardiol Rep ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995505

RESUMEN

PURPOSE OF THE REVIEW: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF). RECENT FINDINGS: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation. ICE-guided catheter ablation is associated with reduced procedural duration and fluoroscopy use. Recent studies have examined the role of ICE in guiding novel ablation techniques, such as pulsed field ablation. Finally, the use of ICE allows for early detection and timely management of potentially serious procedural complications. Intracardiac echocardiography offers significant advantages during AF ablation procedures and its use should be encouraged to improve procedural safety and efficacy.

2.
Hellenic J Cardiol ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38729347

RESUMEN

AIMS: Implantable loop recorders (ILRs) are increasingly being used for long-term cardiac monitoring in different clinical settings. The aim of this study was to investigate the real-world performance of ILRs-including the time to diagnosis- in unselected patients with different ILR indications. METHODS AND RESULTS: In this multicenter, observational study, 871 patients with an indication of pre-syncope/syncope (61.9%), unexplained palpitations (10.4%), and atrial fibrillation (AF) detection with a history of cryptogenic stroke (CS) (27.7%) underwent ILR implantation. The median follow-up was 28.8 ± 12.9 months. In the presyncope/syncope group, 167 (31%) received a diagnosis established by the device. Kaplan-Meier estimates indicated that 16.9% of patients had a diagnosis at 6 months, and the proportion increased to 22.5% at 1 year. Of 91 patients with palpitations, 20 (22%) received a diagnosis based on the device. The diagnosis established at 12.2% of patients at 6 months, and the proportion increased to 13.3% at 1 year. Among 241 patients with CS, 47 (19.5%) were diagnosed with AF. The diagnostic yield of the device was 10.4% at 6 months and 12.4% at 1 year. In all cases, oral anticoagulation was initiated. Overall, ILR diagnosis altered the therapeutic strategy in 26.1% in presyncope/syncope group, 2.2% in palpitations group, and 3.7% in CS group in addition to oral anticoagulation initiation. CONCLUSIONS: In this real-world patient population, ILR determines diagnosis and initiates a new therapeutic management in nearly one fourth of patients. ILR implantation is valuable in the evaluation of patients with unexplained presyncope/syncope, CS and palpitations.

3.
Hellenic J Cardiol ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38777086

RESUMEN

BACKGROUND: Left atrial (LA) fibrosis has been shown to be associated with atrial fibrillation (AF) recurrence. Beat-to-beat (B2B) index is a non-invasive classifier, based on B2B P-wave morphological and wavelet analysis, shown to be associated with AF incidence and recurrence. In this study, we tested the hypothesis that the B2B index is associated with the extent of LA low-voltage areas (LVAs) on electroanatomical mapping. METHODS: Patients with paroxysmal AF scheduled for pulmonary vein isolation, without evident structural remodeling, were included. Pre-ablation electroanatomical voltage maps were used to calculate the surface of LVAs (<0.5 mV). B2B index was compared between patients with small versus large LVAs. RESULTS: 35 patients were included (87% male, median age 62). The median surface area of LVAs was 7.7 (4.4-15.8) cm2 corresponding to 5.6 (3.3-12.1) % of LA endocardial surface. B2B index was 0.57 (0.52-0.59) in patients with small LVAs (below the median) compared to 0.65 (0.56-0.77) in those with large LVAs (above the median) (p = 0.009). In the receiver operator characteristic curve analysis for predicting large LVAs, the c-statistic was 0.75 (p = 0.006) for B2B index and 0.81 for the multivariable model including B2B index (multivariable p = 0.04) and P-wave duration. CONCLUSION: In patients with paroxysmal AF without overt atrial myopathy, B2B P-wave analysis appears to be a useful non-invasive correlate of low-voltage areas-and thus fibrosis-in the LA. This finding establishes a pathophysiological basis for B2B index and its potential usefulness in the selection process of patients who are likely to benefit most from further invasive treatment.

4.
Hellenic J Cardiol ; 72: 1-8, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36907510

RESUMEN

INTRODUCTION: Acute pulmonary vein (PV) reconnection is frequently encountered in patients undergoing PV isolation (PVI) procedure for the treatment of atrial fibrillation. In this study, we investigated whether the identification and ablation of residual potentials (RPs), after the initial achievement of PVI, reduces acute PV reconnection rate. METHODS: Following PVI in 160 patients, mapping along the ablation line was performed to identify RPs, defined as bipolar amplitude ≥0.2 mV or 0.1-0.19 mV combined with a negative component of the unipolar electrogram. Ipsilateral PV sets with RPs were randomized to either no further ablation (Group B) or to additional ablation of the identified RPs (Group C). The primary study endpoint was spontaneous or adenosine-mediated acute PV reconnection after a 30-min waiting period and was also evaluated in ipsilateral PV sets without RPs (Group A). RESULTS: After isolation of 287 PV pairs, 135 had no RPs (Group A), whereas the remaining PV pairs were randomized to either Group B (n = 75) or Group C (n = 77). Ablation of RPs resulted in a reduction of spontaneous or adenosine-mediated PV reconnection rate (16.9% in Group C vs 48.0% in Group B; p < 0.001). Group A was associated with a significantly lower percentage of acute PV reconnection as compared to Group B (5.9% vs 48.0%; p < 0.001) and Group C (5.9% vs 16.9%; p = 0.016). CONCLUSION: After PVI achievement, the absence of RPs along the circumferential line is associated with a low likelihood of acute PV reconnection rate. Ablation of RPs significantly reduces spontaneous or adenosine-mediated acute PV reconnection rate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/métodos , Adenosina , Recurrencia
5.
Diagnostics (Basel) ; 12(4)2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35453877

RESUMEN

The identification of patients prone to atrial fibrillation (AF) relapse after catheter ablation is essential for better patient selection and risk stratification. The current prospective cohort study aims to validate a novel P-wave index based on beat-to-beat (B2B) P-wave morphological and wavelet analysis designed to detect patients with low burden AF as a predictor of AF recurrence within a year after successful catheter ablation. From a total of 138 consecutive patients scheduled for AF ablation, 12-lead ECG and 10 min vectorcardiogram (VCG) recordings were obtained. Univariate analysis revealed that patients with higher B2B P-wave index had a two-fold risk for AF recurrence (HR: 2.35, 95% CI: 1.24-4.44, p: 0.010), along with prolonged P-wave, interatrial block, early AF recurrence, female gender, heart failure history, previous stroke, and CHA2DS2-VASc score. Multivariate analysis of assessable predictors before ablation revealed that B2B P-wave index, along with heart failure history and a history of previous stroke or transient ischemic attack, are independent predicting factors of atrial fibrillation recurrence. Further studies are needed to assess the predictive value of the B2B index with greater accuracy and evaluate a possible relationship with atrial substrate analysis.

6.
J Innov Card Rhythm Manag ; 13(2): 4884-4888, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35251757

RESUMEN

Catheter ablation is currently the therapeutic approach of choice for many patients with accessory pathways. Despite the high success rate of radiofrequency ablation of the left lateral accessory pathways, a rather uncommon manifestation is intra-atrial conduction block at the level of the mitral isthmus. We report 2 cases of orthodromic atrioventricular reentrant tachycardia using a concealed left-sided accessory pathway with an abrupt change in the activation of the coronary sinus from an eccentric to concentric sequence after ablation delivery. The electrophysiological characteristics and the underlying mechanism of the intra-atrial conduction block are commented on. Careful mapping and assessment of relative conduction are helpful to document the diagnosis of intra-atrial conduction block. Familiarity with the likelihood of intra-atrial block during left lateral accessory pathway ablation is needed to avoid the erroneous elucidation that a second accessory pathway is present and to identify correctly the ablation site of interest.

7.
Front Cardiovasc Med ; 9: 853614, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35299975

RESUMEN

Remote monitoring and control of heart function are of primary importance for patient evaluation and management, especially in the modern era of precision medicine and personalized approach. Breaking technological developments have brought to the frontline a variety of smart wearable devices, such as smartwatches, chest patches/straps, or sensors integrated into clothing and footwear, which allow continuous and real-time recording of heart rate, facilitating the detection of cardiac arrhythmias. However, there is great diversity and significant differences in the type and quality of the information they provide, thus impairing their integration into daily clinical practice and the relevant familiarization of practicing physicians. This review will summarize the different types and dominant functions of cardiac smart wearables available in the market. Furthermore, we report the devices certified by official American and/or European authorities and the respective sources of evidence. Finally, we comment pertinent limitations and caveats as well as the potential answers that flow from the latest technological achievements and future perspectives.

8.
Clin Cardiol ; 45(5): 503-508, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35301726

RESUMEN

BACKGROUND: Force-time integral (FTI) is an ablation marker of lesion quality and transmurality. A target FTI of 400 gram-seconds (gs) has been shown to improve durability of pulmonary vein isolation, following atrial fibrillation ablation. However, relevant targets for cavotricuspid isthmus (CTI) ablation are lacking. HYPOTHESIS: We sought to investigate whether CTI ablation with 600 gs FTI lesions is associated with reduced rate of transisthmus conduction recovery compared to 400 gs lesions. METHODS: Fifty patients with CTI-dependent flutter were randomized to ablation using 400 gs (FTI400 group, n = 26) or 600 gs FTI lesions (FTI600 group, n = 24). The study endpoint was spontaneous or adenosine-mediated recovery of transisthmus conduction, after a 20-min waiting period. RESULTS: The study endpoint occurred in five patients (19.2%) in group FTI400 and in four patients (16.7%) in group FTI600, p = .81. First-pass CTI block was similar in both groups (50% in FTI400 vs. 54.2% in FTI600, p = .77). There were no differences in the total number of lesions, total ablation time, procedure time and fluoroscopy duration between the two groups. There were no major complications in any group. In the total population, patients not achieving first-pass CTI block had significantly higher rate of acute CTI conduction recovery, compared to those with first-pass block (29.2% vs. 7.7% respectively, p = .048). CONCLUSIONS: CTI ablation using 600 gs FTI lesions is not associated with reduced spontaneous or adenosine-mediated recurrence of transisthmus conduction, compared to 400 gs lesions.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Adenosina , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
9.
Rev Cardiovasc Med ; 23(1): 25, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35092217

RESUMEN

Catheter ablation is a well-established treatment option for patients with ventricular arrhythmias. Recent advances in various imaging modalities, including three-dimensional electroanatomic mapping systems, magnetic resonance imaging, transesophageal and intracardiac echocardiography (ICE) have been adopted in catheter ablation of ventricular arrhythmias improving procedural outcome and safety. ICE is an imaging tool which provides real-time visualization of anatomical structures of the heart, facilitating catheter manipulation and navigation during ablation procedures. In this review we aim to highlight the benefits of ICE use in catheter ablation of ventricular arrhythmias and to describe practical techniques for visualization of cardiac structures with ICE during ventricular tachycardia ablations.


Asunto(s)
Ablación por Catéter , Ecocardiografía , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ecocardiografía/métodos , Corazón , Humanos
11.
J Electrocardiol ; 69: 87-92, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34619440

RESUMEN

INTRODUCTION: Data regarding the left atrial (LA) electroanatomical substrate in patients with hypertrophic cardiomyopathy (HCM) and atrial fibrillation (AF) are missing. In this electroanatomical mapping (EAM) study, we evaluated the extent of LA fibrosis and its impact on catheter ablation outcomes in patients with HCM and AF. MATERIALS AND METHODS: High-density LA EAM was performed during AF in 28 consecutive patients with obstructive HCM and AF (42.9% displayed paroxysmal AF and 57.1% persistent AF). Propensity score (PS) matching analysis was performed to reduce the impact of potential confounding factors. PS were derived to match patients at a 1:1 ratio. Patients were matched according to age, sex and LA diameter. After PS, 28 non-HCM patients with AF were selected, and served as controls. Two different cut-off values of bipolar signal amplitude were investigated for fibrosis characterization (≤0.25 mV and ≤ 0.4 mV). HCM patients underwent pulmonary vein antral isolation (PVAI) and roof line, while non-HCM patients PVAI only. RESULTS: After the 3-month blanking period, 10 HCM patients (35.7%) displayed atrial arrhythmia recurrence. HCM patients with arrhythmia recurrence showed significantly greater low voltage areas defined as either bipolar voltage ≤0.25 mV (22.5 ± 10% vs. 5.5 ± 6.4%, p = 0.001) or ≤ 0.4 mV (32 ± 13.9% vs. 5.9 ± 5.1%, p < 0.001). The presence of low voltage areas ≤0.4 mV greater than 14.1% of the total LA area also predicted arrhythmia recurrence with excellent sensitivity (100%) and specificity (100%). Univariate analysis revealed that the extent of LA fibrosis was the only predictor of AF recurrence. After PS matching with non-HCM patients, patients with HCM exhibited wider fibrotic regions ≤0.25 mV compared to non-HCM patients (p = 0.016). CONCLUSIONS: High-density EAM reveals extensive LA fibrotic disease in patients with HCM, an event with certain implications in catheter ablation outcomes.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Ablación por Catéter , Fibrilación Atrial/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Electrocardiografía , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Humanos , Recurrencia , Resultado del Tratamiento
13.
Europace ; 23(1): 99-103, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33038213

RESUMEN

AIMS: Cardiac implantable electronic devices (CIEDs) are susceptible to electromagnetic interference (EMI). Smartwatches and their chargers could be a possible source of EMI. We sought to assess whether the latest generation smartwatches and their chargers interfere with proper CIED function. METHODS AND RESULTS: We included consecutive CIED recipients in two centres. We tested two latest generation smartwatches (Apple Watch and Samsung Galaxy Watch) and their charging cables for potential EMI. The testing was performed under continuous electrocardiogram recording and real-time device telemetry, with nominal and 'worst-case' settings. In vitro magnetic field measurements were performed to assess the emissions from the tested devices, initially in contact with the probe and then at a distance of 10 cm and 20 cm. In total, 171 patients with CIEDs (71.3% pacemakers-28.7% implantable cardioverter-defibrillators) from five manufacturers were enrolled (63.2% males, 74.8 ± 11.4 years), resulting in 684 EMI tests. No EMI was identified in any patient either under nominal or 'worst-case scenario' programming. The peak magnetic flux density emitted by the smartwatches was similar to the background noise level (0.81 µT) even when in contact with the measuring probe. The respective values for the chargers were 4.696 µΤ and 4.299 µΤ for the Samsung and Apple chargers, respectively, which fell at the background noise level when placed at 20 cm and 10 cm, respectively. CONCLUSION: Two latest generation smartwatches and their chargers resulted in no EMI in CIED recipients. The absence of EMI in conjunction with the extremely low intensity of magnetic fields emitted by these devices support the safety of their use by CIED patients.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Suministros de Energía Eléctrica , Campos Electromagnéticos/efectos adversos , Electrónica , Femenino , Humanos , Campos Magnéticos , Masculino
14.
J Arrhythm ; 36(4): 785-788, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32782657

RESUMEN

BACKGROUND: The pathophysiological mechanism of focal atrial tachycardias (AT) remains obscure. METHODS: Fifteen patients (6 males, age 45 ± 18) with focal AT underwent high-density activation mapping using a new software called extended early-meets-late (EEML). RESULTS: Irrespective of the arrhythmia mechanism, low bipolar voltage fractionated signals (0.14 ± 0.10 mV) were seen at the earliest activation site. The mean low-voltage area (LVA) at the earliest activation site was 3.2 ± 1.0 cm2. EEML mapping revealed zones of conduction delay at the borders of LVAs. CONCLUSIONS: LVAs protected by zones of slow conduction appears to play an important role in the initiation and maintenance of focal ATs.

15.
J Arrhythm ; 36(3): 537-541, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32528586

RESUMEN

Fasciculoventricular accessory pathways are rare variants of preexcitation. The differential diagnosis of fasciculoventricular accessory pathways from other preexcitation variants can be challenging. Based on two cases, we discuss the specific electrocardiographic and electrophysiologic features of fasciculoventricular bypass tracts.

16.
J Electrocardiol ; 61: 63-65, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32535059

RESUMEN

BACKGROUND: Data regarding the successful ablation site of idiopathic outflow tract (OT) ventricular arrhythmias (VAs) in the modern era of mapping and ablation are limited. METHODS AND RESULTS: Over a 4-year period, a total of 309 patients underwent detailed activation mapping of OT VAs including the right ventricular outflow tract (RVOT), the left ventricular outflow tract (LVOT) and the aortic cusps (AC), and the coronary venous system. 244 cases were successfully ablated at the index procedure (78.9%). The successful ablation site was more frequently located at the LVOT/ACs (51.6%) followed by RVOT (36.2%). In particular, the ACs was the predominant successful ablation site of idiopathic OT VAs (46.7%). An epicardial site of origin was predictor of ablation failure (p < 0.05). CONCLUSIONS: The ACs is the predominant successful ablation site of idiopathic OT VAs. TAKE-HOME MESSAGE: The aortic cusps are the predominant successful ablation site of idiopathic idiopathic outflow tract ventricular arrhythmias.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/cirugía , Electrocardiografía , Ventrículos Cardíacos/cirugía , Humanos , Taquicardia Ventricular/cirugía
18.
Cardiovasc Drugs Ther ; 34(3): 383-389, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32236859

RESUMEN

PURPOSE: Atrial fibrillation (AF) is the most common cardiac arrhythmia with a considerable impact on patients' quality of life (QoL). METHODS: This prospective, multicenter, observational study aimed to evaluate the effect of oral treatment with controlled-release (CR) flecainide on AF patients' QoL and treatment compliance during a 12-week period. A total of 70 sites enrolled consecutive patients with paroxysmal (PAF) or persistent AF (PerAF), treated with flecainide CR in the context of a rhythm control strategy. The effect on QoL was assessed by the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale (CCS-SAF). RESULTS: In total, 679 patients (53.2% females, 66 ± 11.7 years, 86.9% PAF) were included. Prior antiarrhythmic medication had been administered in 43.8% of patients. A daily dose of 200 mg was administered to 66.4% of patients by the end of study. Flecainide CR resulted in a significant reduction in the CCS-SAF score (mean (SD)) at the end of the study as compared with baseline (1.32 (0.57) vs 1.64 (0.73), p < 0.0001). Flecainide CR significantly reduced the CCS-SAF score both in PAF (1.27 (0.52) vs 1.61 (0.72), p < 0.0001) as well as in PerAF (1.63(0.77) vs 1.84(0.81), p = 0.017). Overall, 4 (0.6%) patients experienced a total of 6 adverse events during the study period. The compliance to flecainide CR treatment was very high with 93.6% of patients responding that they had not missed any dose during the study period. CONCLUSION: Treatment with flecainide CR significantly improves QoL in both paroxysmal as well as persistent AF patients, with an excellent safety profile and associated patient compliance.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Flecainida/uso terapéutico , Frecuencia Cardíaca/efectos de los fármacos , Calidad de Vida , Anciano , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/psicología , Preparaciones de Acción Retardada , Femenino , Flecainida/efectos adversos , Humanos , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
19.
Clin Case Rep ; 8(3): 582-583, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32185068

RESUMEN

Reel syndrome occurs due to the rotation of the implantable device on its transverse axis with subsequent coiling of the leads around the pulse generator. Device interrogation and chest X-ray should be performed in any case of device malfunction.

20.
Europace ; 22(3): 342-351, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31998939

RESUMEN

Atrial fibrillation (AF), the most commonly diagnosed arrhythmia, affects a notable percentage of the population and constitutes a major risk factor for thromboembolic events and other heart-related conditions. Fibrosis plays an important role in the onset and perpetuation of AF through structural and electrical remodelling processes. Multiple molecular pathways are involved in atrial substrate modification and the subsequent maintenance of AF. In this review, we aim to recapitulate underlying molecular pathways leading to atrial fibrosis and to indicate existing gaps in the complex interplay of atrial fibrosis and AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/patología , Fibrosis , Atrios Cardíacos/patología , Humanos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...