Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Technol ; 58(25): 11084-11095, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38860676

RESUMEN

Ethylene oxide ("EtO") is an industrially made volatile organic compound and a known human carcinogen. There are few reliable reports of ambient EtO concentrations around production and end-use facilities, however, despite major exposure concerns. We present in situ, fast (1 Hz), sensitive EtO measurements made during February 2023 across the southeastern Louisiana industrial corridor. We aggregated mobile data at 500 m spatial resolution and reported average mixing ratios for 75 km of the corridor. Mean and median aggregated values were 31.4 and 23.3 ppt, respectively, and a majority (75%) of 500 m grid cells were above 10.9 ppt, the lifetime exposure concentration corresponding to 100-in-one million excess cancer risk (1 × 10-4). A small subset (3.3%) were above 109 ppt (1000-in-one million cancer risk, 1 × 10-3); these tended to be near EtO-emitting facilities, though we observed plumes over 10 km from the nearest facilities. Many plumes were highly correlated with other measured gases, indicating potential emission sources, and a subset was measured simultaneously with a second commercial analyzer, showing good agreement. We estimated EtO for 13 census tracts, all of which were higher than EPA estimates (median difference of 21.3 ppt). Our findings provide important information about EtO concentrations and potential exposure risks in a key industrial region and advance the application of EtO analytical methods for ambient sampling and mobile monitoring for air toxics.


Asunto(s)
Monitoreo del Ambiente , Óxido de Etileno , Louisiana , Monitoreo del Ambiente/métodos , Humanos , Contaminantes Atmosféricos/análisis
2.
Indoor Air ; 32(7): e13075, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35904391

RESUMEN

Outdoor aerosols can transform and have their composition altered upon transport indoors. Herein, IMAGES, a platform that simulates indoor organic aerosol with the 2-dimensional volatility basis set (2D-VBS), was extended to incorporate the inorganic aerosol thermodynamic equilibrium model, ISORROPIA. The model performance was evaluated by comparing aerosol component predictions to indoor measurements from an aerosol mass spectrometer taken during the summer and winter seasons. Since ammonia was not measured in the validation dataset, outdoor ammonia was estimated from aerosol measurements using a novel pH-based algorithm, while nitric acid was held constant. Modeled indoor ammonia sources included temperature-based occupant and surface emissions. Sensitivity to the nitric acid indoor surface deposition rate ß g , HNO 3 , g was explored by varying it in model runs, which did not affect modeled sulfate due to its non-volatile nature, though the fitting of a filter efficiency was required for good correlations of modeled sulfate with measurements in both seasons. Modeled summertime nitrate well-matched measured observations when ß g , HNO 3 , g = 2.75 h - 1 , but wintertime comparisons were poor, possibly due to missing thermodynamic processes within the heating, ventilating, and air-conditioning (HVAC) system. Ammonium was consistently overpredicted, potentially due to neglecting thirdhand smoke impacts observed in the field campaign, as well as HVAC impacts.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Amoníaco , Monitoreo del Ambiente/métodos , Ácido Nítrico , Material Particulado , Sulfatos , Termodinámica
3.
Environ Sci Technol ; 55(13): 9000-9011, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34106692

RESUMEN

Outdoor aerosols experience environmental changes as they are transported indoors, including outdoor-to-indoor temperature and mass-loading gradients, which can reduce or enhance their indoor concentrations due to repartitioning driven by changes in thermodynamic equilibrium states. However, the complexity required to model repartitioning typically hinders its inclusion in studies predicting indoor exposure to ambient aerosols. To facilitate exposure predictions, this work used an explicit thermodynamic indoor aerosol model to simulate outdoor-to-indoor aerosol repartitioning typical for residential and office buildings across the 16 U.S. climate zones over an annual time horizon. Results demonstrate that neglecting repartitioning when predicting indoor concentrations can produce errors of up to 80-100% for hydrocarbon-like organic aerosol, 40-60% for total organic aerosol, 400% for ammonium nitrate, and 60% (typically 3 µg/m3) for the total PM2.5 aerosol. Underpredictions were more likely for buildings in hotter than colder regions, and for residences than offices, since both cooler indoor air and more meaningful residential organic aerosol concentrations encourage condensation of semivolatile organics. Furthermore, a method for computing correction factors to more easily account for thermodynamic repartitioning is provided. Applying these correction factors to mechanical-only aerosol predictions significantly reduced errors to <0.5 µg/m3 for the total indoor PM2.5 while bypassing explicit thermodynamic simulations.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Tamaño de la Partícula , Material Particulado/análisis , Temperatura
4.
Chemosphere ; 263: 128304, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33155548

RESUMEN

Gap junction intercellular communication (GJIC) is necessary for ovarian function, and it is temporospatially regulated during follicular development and ovulation. At outermost layer of the antral follicle, theca cells provide structural, steroidogenic, and vascular support. Inter- and extra-thecal GJIC is required for intrafollicular trafficking of signaling molecules. Because GJIC can be altered by hormones and endocrine disrupting chemicals (EDCs), we tested if any of five common EDCs (bisphenol A (BPA), bisphenol S (BPS), bisphenol F (BPF), perfluorooctanesulfonic acid (PFOS), and triphenyltin chloride (TPT)) can interfere with theca cell GJIC. Since most chemicals are reported to repress GJIC, we hypothesized that all chemicals tested, within environmentally relevant human exposure concentrations, will inhibit theca cell GJICs. To evaluate this hypothesis, we used a scrape loading/dye transfer assay. BPS, but no other chemical tested, enhanced GJIC in a dose- and time-dependent manner in ovine primary theca cells. A signal-protein inhibitor approach was used to explore the GJIC-modulatory pathways involved. Phospholipase C and mitogen-activated protein kinase (MAPK) inhibitors significantly attenuated BPS-induced enhanced GJIC. Human theca cells were used to evaluate translational relevance of these findings. Human primary theca cells had a ∼40% increase in GJIC in response to BPS, which was attenuated with a MAPK inhibitor, suggestive of a conserved mechanism. Upregulation of GJIC could result in hyperplasia of the theca cell layer or prevent ovulation by holding the oocyte in meiotic arrest. Further studies are necessary to understand in vitro to in vivo translatability of these findings on follicle development and fertility outcomes.


Asunto(s)
Sustancias Peligrosas/toxicidad , Fenoles/toxicidad , Sulfonas/toxicidad , Células Tecales/fisiología , Animales , Compuestos de Bencidrilo , Comunicación Celular , Comunicación , Conexina 43/metabolismo , Femenino , Uniones Comunicantes/metabolismo , Humanos , Oocitos/metabolismo , Ovinos , Transducción de Señal , Células Tecales/efectos de los fármacos , Células Tecales/metabolismo
5.
Environ Sci Process Impacts ; 22(1): 227, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31848558

RESUMEN

Correction for 'Seasonal variation in aerosol composition and concentration upon transport from the outdoor to indoor environment' by Anita M. Avery et al., Environ. Sci.: Processes Impacts, 2019, 21, 528-547.

6.
Environ Sci Process Impacts ; 21(8): 1301-1312, 2019 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-30997458

RESUMEN

Humans impact indoor air quality directly via emissions from skin, breath, or personal care products, and indirectly via reactions of oxidants with skin constituents, or with skin that has been shed. However, separating the influence of the many emissions and their oxidation products from the influence of outdoor-originated aerosols has been a challenge. Indoor and outdoor aerosols were alternatively sampled at 4 minute time resolution with a high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) in a classroom with student occupants at regular intervals per university class schedule. Mass spectral analysis showed aerosol enhancements of oxidized and unoxidized hydrocarbon ion families during occupied periods, especially at ion fragments larger than m/z 100 and double bond equivalents consistent with squalene (C30H50) and its oxidized products from reaction with ozone, indicative of the secondary nature of the aerosol mass. Individual hydrocarbon mass fragments consistent with squalene fragmentation, including C5H9+, and C6H9+ were especially enhanced with room occupancy. Emissions of individual organic fragment ions were estimated using a model accounting for outdoor aerosols and air exchange. This showed occupancy related emissions at smaller fragments (C3H5+, C4H9+) that despite reflecting mostly outdoor-originated aerosols transported indoors, also show enhancements from occupant emissions indoors. Total emission of all fragments was 17.6 µg ß-1 h-1 above unoccupied levels, translating to approximately 25% increase in organic aerosol mass concentration in the classroom during an occupied hour with a median occupied ozone loss (ß). Human occupants, therefore, represent an additional mass burden of organic aerosol, especially in poorly ventilated or highly occupied indoor spaces.


Asunto(s)
Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Vivienda/normas , Humanos , Hidrocarburos/análisis , Espectrometría de Masas , Ozono/química , Ventilación
7.
Environ Sci Process Impacts ; 21(3): 528-547, 2019 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-30698188

RESUMEN

Outdoor-originated aerosols are an important component impacting indoor air quality. Since outdoor aerosols vary over short (diurnal) and long (seasonal) timescales, we examined how the variation in outdoor aerosol concentration and composition impact indoor aerosol. Measurements of both indoor and outdoor aerosol composition in real time in an urban classroom in winter and summer seasons were performed using an aerosol mass spectrometer (AMS), aethalometer, and a suite of gas phase instruments. Factor analysis of the organic aerosol components identified three factors in common between seasons, including hydrocarbon-like, cooking, and oxidized organic aerosol (HOA, COA, and OOA). Since sulfate is non-volatile, we report a sulfate-normalized indoor-outdoor ratio (I/O)i/SO4 for measured aerosol i components, allowing us to estimate aerosol component-based effects of seasonal and other variations in ventilation and HVAC operation, indoor emission sources, and chemically-based loss processes between outdoor and indoor environments. These chemical loss processes are interpreted in terms of changes in temperature and relative humidity (RH) between environments, which fluctuate on a daily and seasonal basis. The degree to which any effect is observed depends on the particular outdoor aerosol population and the magnitude of temperature or RH change. In wintertime, when aerosols were warmed upon transport indoors and loss of volatile components is favored, median (I/O)i/SO4 values for nitrate, total organics, HOA, and BC were smaller (0.35, 1.00, 1.24, and 1.18, respectively) than summertime values (0.75, 1.17, 1.96, and 1.80). For COA and OOA, however, (I/O)i/SO4 values were higher in the winter than in summer. Calculated aerosol liquid water (ALW), which is a function of temperature and RH and the relative contribution of hygroscopic components, varied significantly by season. Summertime ALW indoors provides a medium for aqueous processing, which is necessary for some hydrophilic gas phase reaction products that are important to indoor air quality and occupant exposure. This work describes the linkages between seasonal variability in aerosol composition outdoors and the subsequent chemically-specific variation observed when that aerosol is brought indoors.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Compuestos Orgánicos Volátiles/análisis , Aerosoles , Philadelphia , Estaciones del Año , Temperatura
8.
Sci Adv ; 4(5): eaap8368, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29750194

RESUMEN

Aerosol composition measurements made in an indoor classroom indicate the uptake of thirdhand smoke (THS) species to indoor particles, a novel exposure route for THS to humans indoors. Chemical speciation of the organic aerosol fraction using mass spectrometric data and factor analysis identified a reduced nitrogen component, predominantly found in the indoor environment, contributing 29% of the indoor submicron aerosol mass. We identify this factor as THS compounds partitioning from interior surfaces to gas phase and then aerosol phase. Partitioning of THS vapors to aerosols requires an aqueous phase for reactive uptake of the reduced nitrogen species (RdNS), leading to seasonal differences in THS concentration indoors. RdNS protonate under the acidic conditions expected for indoor aerosols of outdoor origin. Controlled laboratory measurements performed using cigarette smoke deposited into a Pyrex vessel showed a similar partitioning behavior to aerosol of outdoor origin and mass spectral features comparable to the measured indoor THS factor after 1 week of residence time in the closed vessel. This study reports a new, potentially large THS exposure route from partitioning of surface volatile organic compounds into the aerosol phase and subsequent dispersion in a mechanically ventilated building.


Asunto(s)
Aerosoles , Contaminación del Aire Interior , Contaminación por Humo de Tabaco/efectos adversos , Aerosoles/análisis , Aerosoles/química , Contaminación del Aire Interior/análisis , Humanos , Nitrógeno , Tamaño de la Partícula , Fumar
9.
Spine (Phila Pa 1976) ; 27(1): E1-8, 2002 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-11805650

RESUMEN

STUDY DESIGN: An experimental study of respiratory function and kinematics of the diaphragm and pelvic floor in subjects with a clinical diagnosis of sacroiliac joint pain and in a comparable pain-free subject group was conducted. OBJECTIVE: To gain insight into the motor control strategies of subjects with sacroiliac joint pain and the resultant effect on breathing pattern. SUMMARY OF BACKGROUND DATA: The active straight-leg-raise test has been proposed as a clinical test for the assessment of load transfer through the pelvis. Clinical observations show that patients with sacroiliac joint pain have suboptimal motor control strategies and alterations in respiratory function when performing low-load tasks such as an active straight leg raise. METHODS: In this study, 13 participants with a clinical diagnosis of sacroiliac joint pain and 13 matched control subjects in the supine resting position were tested with the active straight leg raise and the active straight leg raise with manual compression through the ilia. Respiratory patterns were recorded using spirometry, and minute ventilation was calculated. Diaphragmatic excursion and pelvic floor descent were measured using ultrasonography. RESULTS: The participants with sacroiliac joint pain exhibited increased minute ventilation, decreased diaphragmatic excursion, and increased pelvic floor descent, as compared with pain-free subjects. Considerable variation was observed in respiratory patterns. Enhancement of pelvis stability via manual compression through the ilia reversed these differences. CONCLUSIONS: The study findings formally identified altered motor control strategies and alterations of respiratory function in subjects with sacroiliac joint pain. The changes observed appear to represent a compensatory strategy of the neuromuscular system to enhance force closure of the pelvis where stability has been compromised by injury.


Asunto(s)
Artralgia/fisiopatología , Diafragma/fisiopatología , Prueba de Esfuerzo , Desempeño Psicomotor , Articulación Sacroiliaca/fisiopatología , Adulto , Fenómenos Biomecánicos , Demografía , Diafragma/diagnóstico por imagen , Femenino , Humanos , Dolor de la Región Lumbar , Masculino , Diafragma Pélvico/diagnóstico por imagen , Pruebas de Función Respiratoria , Articulación Sacroiliaca/diagnóstico por imagen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA