Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Radiol ; 82(11): 1613-9, 2001 Nov.
Artículo en Francés | MEDLINE | ID: mdl-11894546

RESUMEN

PURPOSE: Retrospective analysis of the morphologic and hemodynamic characteristics of hemangiomas in infants provided by color Doppler sonography. MATERIALS AND METHODS: 94 hemangiomas were studied in 87 children separated into four classes of age (0-3 months, 3-6 months, 6-12 months, > 12 months). Eleven were followed with several examinations. Echogenicity, compared to normal subcutaneous tissues, and degree of vascularization were assessed qualitatively. Resistive index (RI) was measured in 78 cases. RESULTS: All lesions presented as vascularized solid masses: 63% were hypoechoic, 16% hyperechoic and 21% mixed. All hypoechoic and mixed lesions showed higher vascularity than hyperechoic ones. Hyperechoic hemanigomas were more frequent in the fourth class of age. Mean resistive index was significantly higher in the first (0.61 +/- 0.14) and the fourth (0.6 +/- 0.14) classes of age than in the second (0.51 +/- 0.12) (p = 0.01 and < 0.03, respectively), and higher in the hyperechoic group (0.7 +/- 0.13) than in the hypoechoic group (0.53 +/- 0.11), (p < 0.01). Seven of 11 cases moved from hypoechoic to hyperechoic or mixed. Increase of resistive index with age was noted in 9/11 cases. CONCLUSIONS: Superficial hemangiomas have typical but variable gray-scale, spectral and color flow sonographic patterns. These fluctuations are probably related to phases of evolution.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Hemangioma Capilar/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen , Ultrasonografía Doppler en Color , Factores de Edad , Niño , Preescolar , Neoplasias Faciales/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Cuero Cabelludo/diagnóstico por imagen , Factores Sexuales , Factores de Tiempo
3.
J Radiol ; 81(2): 133-9, 2000 Feb.
Artículo en Francés | MEDLINE | ID: mdl-10705143

RESUMEN

PURPOSE: To compare the diagnosis performances of radiologists on screen film versus digital mammography. MATERIAL: and methods: Two sets of 123 mammograms, screen film mammography and storage phosphor digital mammography, are studied comparatively with ROC analysis. RESULTS: Phantom study show that conventional method give better scores for usual tension but the detectability of smaller microcalcification is equivalent. To obtain with digital technic the same conventional score you have to increase the radiation dose. Roc Curves, simulated "detection" mode showed that radiologists performed with higher accuracy with conventional system but this difference is weekly statistically significant. ROC Curves, simulated "diagnostic" mode showed the same results wit no statistically significant difference but when the decision to go to the biopsy is the gold standard, ROC Curves were essentially equivalent for both film screen and digital mammography system. The readers consistently considered the digital mammograms to be less suspicious for cancer findings. The agreement study as proposed by the FDA indicate that probability of a positive digital mammograms given a positive screen film is 75% (threshold value 90%) and the probability of a negative digital mammograms given a negative analog film is 85% (threshold value 85%). CONCLUSION: Analysis of specific discrepancies indicate that spatial resolution is an essential limiting factor for digital method but high resolution phosphor plate are interesting in imaging treated breast, radioluscent lesion, fatty benign tumor, hamartoma, intramammary lymph node, breast with prosthesis.


Asunto(s)
Mamografía/métodos , Intensificación de Imagen Radiográfica , Pantallas Intensificadoras de Rayos X , Biopsia , Enfermedades de la Mama/diagnóstico por imagen , Implantes de Mama , Neoplasias de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Toma de Decisiones , Femenino , Hamartoma/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Ganglios Linfáticos/diagnóstico por imagen , Mamografía/estadística & datos numéricos , Fantasmas de Imagen , Probabilidad , Curva ROC , Dosis de Radiación , Radiología/estadística & datos numéricos , Pantallas Intensificadoras de Rayos X/estadística & datos numéricos
4.
J Mal Vasc ; 24(3): 202-7, 1999 Jun.
Artículo en Francés | MEDLINE | ID: mdl-10467530

RESUMEN

Hemorrhagic complications are the most frequent complications of antivitamin K (AVK) treatments and can be life-threatening. We report 75 patients from a University Hospital. They were 40 males and 35 females (median age 74 years, 20-94), and were classified into 3 grades according to clinical picture: grade 1 (no surgery or transfusion, grade 2: surgery or blood transfusion needed, grade 3: death). 43 patients had grade 1 complications, 27 grade 2, and 5 grade 3 complications. The most frequent complications were muscular hematomas (36 patients), sub-cutaneous hematomas (14 patients), digestive bleeding (13 patients), hematuria (12 subjects). Eight patients had intracerebral bleeding, of whom 3 died. The treatment time was very variable (1 to 988 weeks). Only half patients had a prothrombin rate (PR) below 20% but two thirds had an INR above 5. This study showed that PR was a poor predictor of hemorrhagic complications. INR was a better parameter. For 15 patients, we considered that the indication was unadapted or questionable, among whom 2 died. This work suggests that the promotion of AVK prescription rules should go on.


Asunto(s)
Hemorragia/inducido químicamente , Vitamina K/antagonistas & inhibidores , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hospitalización , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Tiempo de Protrombina , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...