Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Clin Res Cardiol ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046472

RESUMEN

BACKGROUND: To assess the interaction between heart failure (HF) severity and optimal reduction of secondary mitral regurgitation (SMR) on mortality in patients undergoing transcatheter edge-to-edge repair (M-TEER). METHODS AND RESULTS: Among 1656 patients included in the Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) 984 had SMR and complete data on advanced HF. Advanced HF was defined as NYHA class III or IV, left ventricular ejection fraction ≤ 30%, and > 1 HF hospitalization during the last 12 months. Optimal M-TEER was defined as residual SMR ≤ 1 + at discharge. One hundred sixteen patients (11.8%) had advanced HF. Achievement of an optimal SMR reduction was similar in patients with and without advanced HF (65% and 60% respectively). Advanced HF was an independent predictor of 2-year all-cause death (adjusted HR 1.52, 95% CI 1.09-2.10). Optimal M-TEER, as compared to a no-optimal M-TEER, was associated with a reduced risk of death both in patients with advanced (HR 0.55, 95% CI 0.32-0.97; p = 0.039) and no-advanced HF (HR 0.59, 95% CI 0.46-0.78; p < 0.001; p = 0.778 for interaction). CONCLUSIONS: Advanced HF is associated with poor outcome in patients undergoing M-TEER. However, an optimal SMR reduction reduces the risk of 2-year mortality regardless of HF severity.

2.
Int J Cardiol ; 413: 132317, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38986745

RESUMEN

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal M-TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing M-TEER had a Euroscore<4% with a median age of 81. An optimally successful M-TEER was associated with a lower mortality regardless of EuroSCORE.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/mortalidad , Masculino , Femenino , Anciano , Prevalencia , Cateterismo Cardíaco/métodos , Italia/epidemiología , Resultado del Tratamiento , Anciano de 80 o más Años , Estudios Prospectivos , Factores de Riesgo , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/tendencias
3.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38742523

RESUMEN

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Masculino , Femenino , Anciano , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Italia/epidemiología , Anciano de 80 o más Años , Readmisión del Paciente/estadística & datos numéricos , Insuficiencia del Tratamiento , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía
4.
J Thromb Thrombolysis ; 57(5): 757-766, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38615155

RESUMEN

The use of intravenous antiplatelet therapy during primary percutaneous coronary intervention (PPCI) is not fully standardized. The aim is to evaluate the effectiveness and safety of periprocedural intravenous administration of cangrelor or tirofiban in a contemporary ST-segment elevation myocardial infarction (STEMI) population undergoing PPCI. This was a multicenter prospective cohort study including consecutive STEMI patients who received cangrelor or tirofiban during PPCI at seven Italian centers. The primary effectiveness measure was the angiographic evidence of thrombolysis in myocardial infarction (TIMI) flow < 3 after PPCI. The primary safety outcome was the in-hospital occurrence of BARC (Bleeding Academic Research Consortium) 2-5 bleedings. The study included 627 patients (median age 63 years, 79% males): 312 received cangrelor, 315 tirofiban. The percentage of history of bleeding, pulmonary edema and cardiogenic shock at admission was comparable between groups. Patients receiving cangrelor had lower ischemia time compared to tirofiban. TIMI flow before PPCI and TIMI thrombus grade were comparable between groups. At propensity score-weighted regression analysis, the risk of TIMI flow < 3 was significantly lower in patients treated with cangrelor compared to tirofiban (adjusted OR: 0.40; 95% CI: 0.30-0.53). The risk of BARC 2-5 bleeding was comparable between groups (adjusted OR:1.35; 95% CI: 0.92-1.98). These results were consistent across multiple prespecified subgroups, including subjects stratified for different total ischemia time, with no statistical interaction. In this real-world multicenter STEMI population, the use of cangrelor was associated with improved myocardial perfusion assessed by coronary angiography after PPCI without increasing clinically-relevant bleedings compared to tirofiban.


Asunto(s)
Adenosina Monofosfato , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Infarto del Miocardio con Elevación del ST , Tirofibán , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adenosina Monofosfato/análogos & derivados , Adenosina Monofosfato/administración & dosificación , Adenosina Monofosfato/uso terapéutico , Adenosina Monofosfato/efectos adversos , Administración Intravenosa , Hemorragia/inducido químicamente , Italia , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Tirofibán/administración & dosificación , Tirofibán/uso terapéutico , Resultado del Tratamiento
5.
J Invasive Cardiol ; 36(8)2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38598251

RESUMEN

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Femenino , Masculino , Cateterismo Cardíaco/métodos , Anciano , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano de 80 o más Años , Estudios Prospectivos , Sistema de Registros , Ecocardiografía Transesofágica/métodos , Estudios de Seguimiento , Prótesis Valvulares Cardíacas
6.
J Clin Med ; 13(6)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38542052

RESUMEN

The Journal of Clinical Medicine retracts the article "An Admission-to-Discharge BNP Increase Is a Predictor of Six-Month All-Cause Death in ADHF Patients: Inferences from Multivariate Analysis Including Admission BNP and Various Clinical Measures of Congestion" [...].

7.
J Clin Med ; 13(6)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38542053

RESUMEN

The Journal of Clinical Medicine retracts the article "Vasopressin Receptor Antagonists for the Correction of Hyponatremia in Chronic Heart Failure: An Underutilized Therapeutic Option in Current Clinical Practice [...].

8.
J Am Heart Assoc ; 12(17): e029553, 2023 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-37646211

RESUMEN

Background There is little evidence about the prognostic role of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). The aim of this study was to assess the prevalence and outcome implications of MR severity in patients with low-flow, low-gradient aortic stenosis undergoing TAVR, and to evaluate whether MR improvement after TAVR could influence clinical outcome. Methods and Results This study included consecutive patients with low-flow, low-gradient aortic stenosis undergoing TAVR at 2 Italian high-volume centers. The study population was categorized according to the baseline MR severity and to the presence of MR improvement at discharge. The primary outcome was the composite of all-cause death and hospitalization for worsening heart failure up to 1 year. The study included 268 patients; 57 (21%) patients showed MR >2+. Patients with MR >2+ showed a lower 1-year survival free from the primary outcome (P<0.001), all-cause death (P<0.001), and heart failure hospitalization (P<0.001) compared with patients with MR ≤2+. At multivariable analysis, baseline MR >2+ was an independent predictor of the primary outcome (P<0.001). Among patients with baseline MR >2+, MR improvement was reported in 24 (44%) cases after TAVR. The persistence of MR was associated with a significantly reduced survival free from the primary outcome, all-cause death, and heart failure hospitalization up to 1 year. Conclusions In this study, the presence of moderately severe to severe MR in patients with low-flow, low-gradient aortic stenosis undergoing TAVR portends a worse clinical outcome at 1 year. TAVR may improve MR severity in nearly half of the patients, resulting in a potential outcome benefit after discharge.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
9.
Am Heart J ; 265: 153-160, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37572785

RESUMEN

BACKGROUND: Over the past few decades, percutaneous coronary intervention (PCI) has undergone significant advancements as a result of the combination of device-based and drug-based therapies. These iterations have led to the development of polymer-free drug-eluting stents. However, there is a scarcity of data regarding their clinical performance. Furthermore, while various risk scores have been proposed to determine the optimal duration of dual antiplatelet therapy (DAPT), none of them have undergone prospective validation within the context of randomized trials. DESIGN: The PARTHENOPE trial is a phase IV, prospective, randomized, multicenter, investigator-initiated, assessor-blind study being conducted at 14 centers in Italy (NCT04135989). It includes 2,107 all-comers patients with minimal exclusion criteria, randomly assigned in a 2-by-2 design to receive either the Cre8 amphilimus-eluting stent or the SYNERGY everolimus-eluting stent, along with either a personalized or standard duration of DAPT. Personalized DAPT duration is determined by the DAPT score, which accounts for both bleeding and ischemic risks. Patients with a DAPT score <2 (indicating higher bleeding than ischemic risk) receive DAPT for 3 or 6 months for chronic or acute coronary syndrome, respectively, while patients with a DAPT score ≥2 (indicating higher ischemic than bleeding risk) receive DAPT for 24 months. Patients in the standard DAPT group receive DAPT for 12 months. The trial aims to establish the noninferiority between stents with respect to a device-oriented composite end point of cardiovascular death, target-vessel myocardial infarction, or clinically-driven target-lesion revascularization at 12 months after PCI. Additionally, the trial aims to demonstrate the superiority of personalized DAPT compared to a standard approach with respect to a net clinical composite of all-cause death, any myocardial infarction, stroke, urgent target-vessel revascularization, or type 2 to 5 bleeding according to the Bleeding Academic Research Consortium criteria at 24-months after PCI. SUMMARY: The PARTHENOPE trial is the largest randomized trial investigating the efficacy and safety of a polymer-free DES with a reservoir technology for drug-release and the first trial evaluating a personalized duration of DAPT based on the DAPT score. The study results will provide novel insights into the optimizing the use of drug-eluting stents and DAPT in patients undergoing PCI.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/métodos , Polímeros , Hemorragia/inducido químicamente , Infarto del Miocardio/etiología , Resultado del Tratamiento , Quimioterapia Combinada
10.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37259492

RESUMEN

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Asunto(s)
Enfermedad de la Arteria Coronaria , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA