Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Eur Radiol ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758252

RESUMEN

INTRODUCTION: This study investigates the performance of a commercially available artificial intelligence (AI) system to identify normal chest radiographs and its potential to reduce radiologist workload. METHODS: Retrospective analysis included consecutive chest radiographs from two medical centers between Oct 1, 2016 and Oct 14, 2016. Exclusions comprised follow-up exams within the inclusion period, bedside radiographs, incomplete images, imported radiographs, and pediatric radiographs. Three chest radiologists categorized findings into normal, clinically irrelevant, clinically relevant, urgent, and critical. A commercial AI system processed all radiographs, scoring 10 chest abnormalities on a 0-100 confidence scale. AI system performance was evaluated using the area under the ROC curve (AUC), assessing the detection of normal radiographs. Sensitivity was calculated for the default and a conservative operating point. the detection of negative predictive value (NPV) for urgent and critical findings, as well as the potential workload reduction, was calculated. RESULTS: A total of 2603 radiographs were acquired in 2141 unique patients. Post-exclusion, 1670 radiographs were analyzed. Categories included 479 normal, 332 clinically irrelevant, 339 clinically relevant, 501 urgent, and 19 critical findings. The AI system achieved an AUC of 0.92. Sensitivity for normal radiographs was 92% at default and 53% at the conservative operating point. At the conservative operating point, NPV was 98% for urgent and critical findings, and could result in a 15% workload reduction. CONCLUSION: A commercially available AI system effectively identifies normal chest radiographs and holds the potential to lessen radiologists' workload by omitting half of the normal exams from reporting. CLINICAL RELEVANCE STATEMENT: The AI system is able to detect half of all normal chest radiographs at a clinically acceptable operating point, thereby potentially reducing the workload for the radiologists by 15%. KEY POINTS: The AI system reached an AUC of 0.92 for the detection of normal chest radiographs. Fifty-three percent of normal chest radiographs were identified with a NPV of 98% for urgent findings. AI can reduce the workload of chest radiography reporting by 15%.

2.
BMC Med Educ ; 24(1): 479, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38693517

RESUMEN

BACKGROUND: Modern medicine becomes more dependent on radiologic imaging techniques. Over the past decade, radiology has also gained more attention in the medical curricula. However, little is known with regard to students' perspectives on this subject. Therefore, this study aims to gain insight into the thoughts and ideas of medical students and junior doctors on radiology education in medical curricula. METHODS: A qualitative, descriptive study was carried out at one medical university in the Netherlands. Participants were recruited on social media and were interviewed following a predefined topic list. The constant comparative method was applied in order to include new questions when unexpected topics arose during the interviews. All interviews were transcribed verbatim and coded. Codes were organized into categories and themes by discussion between researchers. RESULTS: Fifteen participants (nine junior doctors and six students) agreed to join. From the coded interviews, four themes derived from fifteen categories arose: (1) The added value of radiology education in medical curricula, (2) Indispensable knowledge on radiology, (3) Organization of radiology education and (4) Promising educational innovations for the radiology curriculum. CONCLUSION: This study suggests that medical students and junior doctors value radiology education. It provides insights in educational topics and forms for educational improvement for radiology educators.


Asunto(s)
Curriculum , Investigación Cualitativa , Radiología , Estudiantes de Medicina , Humanos , Países Bajos , Radiología/educación , Estudiantes de Medicina/psicología , Masculino , Femenino , Cuerpo Médico de Hospitales/educación , Actitud del Personal de Salud , Educación de Pregrado en Medicina , Entrevistas como Asunto , Adulto , Facultades de Medicina
3.
Acta Radiol ; : 2841851241240446, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38630492

RESUMEN

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel imaging technique that increases the applicability of CT for cardiac imaging; however, the scanning requires a substantial radiation dose. PURPOSE: To investigate the feasibility of dose reduction in dynamic CTP by comparing all-heartbeat acquisitions to periodic skipping of heartbeats. MATERIAL AND METHODS: We retrieved imaging data of 38 dynamic CTP patients and created new datasets with every fourth, third or second beat (Skip1:4, Skip1:3, Skip1:2, respectively) removed. Seven observers evaluated the resulting images and perfusion maps for perfusion deficits. The mean blood flow (MBF) in each of the 16 myocardial segments was compared per skipped-beat level, normalized by the respective MBF for the full dose, and averaged across patients. The number of segments/cases whose MBF was <1.0 mL/g/min were counted. RESULTS: Out of 608 segments in 38 cases, the total additional number of false-negative (FN) segments over those present in the full-dose acquisitions and the number of additional false-positive cases were shown as acquisition (segment [%], case): Skip1:4: 7 (1.2%, 1); Skip1:3: 12 (2%, 3), and Skip1:2: 5 (0.8%, 2). The variability in quantitative MBF analysis in the repeated analysis for the reference condition resulted in 8 (1.3%) additional FN segments. The normalized results show a comparable MBF across all segments and patients, with relative mean MBFs as 1.02 ± 0.16, 1.03 ± 0.25, and 1.06 ± 0.30 for the Skip1:4, Skip1:3, and Skip1:2 protocols, respectively. CONCLUSION: Skipping every second beat acquisition during dynamic myocardial CTP appears feasible and may result in a radiation dose reduction of 50%. Diagnostic performance does not decrease after removing 50% of time points in dynamic sequence.

4.
Acta Radiol ; 64(3): 999-1006, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35765201

RESUMEN

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel technique able to depict cardiac ischemia. PURPOSE: To evaluate the impact of a four-dimensional noise reduction filter (similarity filter [4D-SF]) on image quality in dynamic CTP imaging, allowing for substantial radiation dose reduction. MATERIAL AND METHODS: Dynamic CTP datasets of 30 patients (16 women) with suspected coronary artery disease, acquired with a 320-slice CT system, were retrieved, reconstructed with the deep learning-based algorithm of the system (DLR), and filtered with the 4D-SF. For each case, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in six regions of interest (33-38mm2) were calculated before and after filtering, in four-chamber and short-axis views, and t-tested. Furthermore, six radiologists of different expertise evaluated subjective image preference by answering five visual grading analysis-type questions (regarding acceptable level of noise, absence of artifacts, natural appearance, cardiac contour sharpness, diagnostic acceptability) using a 5-point scale. The results were analyzed using visual grade characteristics (VGC) and intraclass correlation coefficient (ICC). RESULTS: Mean SNR in four-chamber view (unfiltered vs. filtered) were: septum=4.1 ± 2.1 versus 7.6 ± 5.6; lateral wall=4.5 ± 2.0 versus 8.0 ± 4.9; CNRseptum=16.6 ± 8.9 versus 31.7 ± 28; lateral wall=16.2 ± 8.9 versus 31.3 ± 28.9. Similar results were obtained in short-axis view. The perceived filtered image quality indicated decreased noise (VGCAUC=0.96) and artifacts (0.65), improved natural appearance (0.59), cardiac contour sharpness (0.74), and diagnostic acceptability (0.78). The inter-observer variability was excellent (ICC=0.79). All results were statistically significant (P < 0.05). CONCLUSION: Similarity filtering after DLR improves image quality, possibly enabling dose reduction in dynamic CTP imaging in patient with suspected chronic coronary syndrome.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Femenino , Imagen de Perfusión Miocárdica/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Miocardio , Corazón/diagnóstico por imagen , Relación Señal-Ruido , Algoritmos , Tomografía , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosis de Radiación
6.
PLoS One ; 12(11): e0185032, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29121063

RESUMEN

PURPOSE: To compare human observers to a mathematically derived computer model for differentiation between malignant and benign pulmonary nodules detected on baseline screening computed tomography (CT) scans. METHODS: A case-cohort study design was chosen. The study group consisted of 300 chest CT scans from the Danish Lung Cancer Screening Trial (DLCST). It included all scans with proven malignancies (n = 62) and two subsets of randomly selected baseline scans with benign nodules of all sizes (n = 120) and matched in size to the cancers, respectively (n = 118). Eleven observers and the computer model (PanCan) assigned a malignancy probability score to each nodule. Performances were expressed by area under the ROC curve (AUC). Performance differences were tested using the Dorfman, Berbaum and Metz method. Seven observers assessed morphological nodule characteristics using a predefined list. Differences in morphological features between malignant and size-matched benign nodules were analyzed using chi-square analysis with Bonferroni correction. A significant difference was defined at p < 0.004. RESULTS: Performances of the model and observers were equivalent (AUC 0.932 versus 0.910, p = 0.184) for risk-assessment of malignant and benign nodules of all sizes. However, human readers performed superior to the computer model for differentiating malignant nodules from size-matched benign nodules (AUC 0.819 versus 0.706, p < 0.001). Large variations between observers were seen for ROC areas and ranges of risk scores. Morphological findings indicative of malignancy referred to border characteristics (spiculation, p < 0.001) and perinodular architectural deformation (distortion of surrounding lung parenchyma architecture, p < 0.001; pleural retraction, p = 0.002). CONCLUSIONS: Computer model and human observers perform equivalent for differentiating malignant from randomly selected benign nodules, confirming the high potential of computer models for nodule risk estimation in population based screening studies. However, computer models highly rely on size as discriminator. Incorporation of other morphological criteria used by human observers to superiorly discriminate size-matched malignant from benign nodules, will further improve computer performance.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tamizaje Masivo , Interpretación de Imagen Radiográfica Asistida por Computador , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Probabilidad , Factores de Riesgo
7.
Radiology ; 277(3): 863-71, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26020438

RESUMEN

PURPOSE: To examine the factors that affect inter- and intraobserver agreement for pulmonary nodule type classification on low-radiation-dose computed tomographic (CT) images, and their potential effect on patient management. MATERIALS AND METHODS: Nodules (n = 160) were randomly selected from the Dutch-Belgian Lung Cancer Screening Trial cohort, with equal numbers of nodule types and similar sizes. Nodules were scored by eight radiologists by using morphologic categories proposed by the Fleischner Society guidelines for management of pulmonary nodules as solid, part solid with a solid component smaller than 5 mm, part solid with a solid component 5 mm or larger, or pure ground glass. Inter- and intraobserver agreement was analyzed by using Cohen κ statistics. Multivariate analysis of variance was performed to assess the effect of nodule characteristics and image quality on observer disagreement. Effect on nodule management was estimated by differentiating CT follow-up for ground-glass nodules, solid nodules 8 mm or smaller, and part-solid nodules smaller than 5 mm from immediate diagnostic work-up for solid nodules larger than 8 mm and part-solid nodules 5 mm or greater. RESULTS: Pair-wise inter- and intraobserver agreement was moderate (mean κ, 0.51 [95% confidence interval, 0.30, 0.68] and 0.57 [95% confidence interval, 0.47, 0.71]). Categorization as part-solid nodules and location in the upper lobe significantly reduced observer agreement (P = .012 and P < .001, respectively). By considering all possible reading pairs (28 possible combinations of observer pairs × 160 nodules = 4480 possible agreements or disagreements), a discordant nodule classification was found in 36.4% (1630 of 4480), related to presence or size of a solid component in 88.7% (1446 of 1630). Two-thirds of these discrepant readings (1061 of 1630) would have potentially resulted in different nodule management. CONCLUSION: There is moderate inter- and intraobserver agreement for nodule classification by using current recommendations for low-radiation-dose CT examinations of the chest. Discrepancies in nodule categorization were mainly caused by disagreement on the size and presence of a solid component, which may lead to different management in the majority of cases with such discrepancies. (©) RSNA, 2015.


Asunto(s)
Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/terapia , Tomografía Computarizada por Rayos X , Humanos , Variaciones Dependientes del Observador
8.
IEEE Trans Med Imaging ; 34(12): 2429-42, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25706581

RESUMEN

Tuberculosis (TB) is a common disease with high mortality and morbidity rates worldwide. Automatic systems to detect TB on chest radiographs (CXRs) can improve the efficiency of diagnostic algorithms for pulmonary TB. The diverse manifestation of TB on CXRs from different populations requires a system that can be adapted to deal with different types of abnormalities. A computer aided detection (CAD) system was developed which combines several subscores of supervised subsystems detecting textural, shape, and focal abnormalities into one TB score. A general framework was developed to combine an arbitrary number of subscores: subscores were normalized, collected in a feature vector and then combined using a supervised classifier into one combined score. The method was evaluated on two databases, both consisting of 200 digital CXRs, from: (A) Western high-risk group screening, (B) TB suspect screening in Africa. The subscores and combined score were compared to (1) an external, non-radiological, reference and (2) a radiological reference determined by a human expert. Performance was measured using Receiver Operator Characteristic (ROC) analysis. Different subscores performed best in the two databases. The combined TB score performed better than the individual subscores, except for the external reference in database B. The performances of the independent observer were slightly higher than the combined TB score. Compared to the external reference, differences in performance between the combined TB score and the independent observer were not significant in both databases. Supervised combination to compute an overall TB score allows for a necessary adaptation of the CAD system to different settings or different operational requirements.


Asunto(s)
Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tuberculosis Pulmonar/diagnóstico por imagen , Algoritmos , Humanos , Curva ROC
9.
Med Phys ; 41(7): 071912, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24989390

RESUMEN

PURPOSE: Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation in chest radiographs. METHODS: A two stage method is proposed to segment the cavity borders, given a user defined seed point close to the center of the cavity. First, a supervised learning approach is employed to train a pixel classifier using texture and radial features to identify the border pixels of the cavity. A likelihood value of belonging to the cavity border is assigned to each pixel by the classifier. The authors experimented with four different classifiers:k-nearest neighbor (kNN), linear discriminant analysis (LDA), GentleBoost (GB), and random forest (RF). Next, the constructed likelihood map was used as an input cost image in the polar transformed image space for dynamic programming to trace the optimal maximum cost path. This constructed path corresponds to the segmented cavity contour in image space. RESULTS: The method was evaluated on 100 chest radiographs (CXRs) containing 126 cavities. The reference segmentation was manually delineated by an experienced chest radiologist. An independent observer (a chest radiologist) also delineated all cavities to estimate interobserver variability. Jaccard overlap measure Ω was computed between the reference segmentation and the automatic segmentation; and between the reference segmentation and the independent observer's segmentation for all cavities. A median overlap Ω of 0.81 (0.76 ± 0.16), and 0.85 (0.82 ± 0.11) was achieved between the reference segmentation and the automatic segmentation, and between the segmentations by the two radiologists, respectively. The best reported mean contour distance and Hausdorff distance between the reference and the automatic segmentation were, respectively, 2.48 ± 2.19 and 8.32 ± 5.66 mm, whereas these distances were 1.66 ± 1.29 and 5.75 ± 4.88 mm between the segmentations by the reference reader and the independent observer, respectively. The automatic segmentations were also visually assessed by two trained CXR readers as "excellent," "adequate," or "insufficient." The readers had good agreement in assessing the cavity outlines and 84% of the segmentations were rated as "excellent" or "adequate" by both readers. CONCLUSIONS: The proposed cavity segmentation technique produced results with a good degree of overlap with manual expert segmentations. The evaluation measures demonstrated that the results approached the results of the experienced chest radiologists, in terms of overlap measure and contour distance measures. Automatic cavity segmentation can be employed in TB clinics for treatment monitoring, especially in resource limited settings where radiologists are not available.


Asunto(s)
Algoritmos , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tuberculosis/diagnóstico por imagen , Bases de Datos Factuales , Análisis Discriminante , Humanos , Funciones de Verosimilitud , Modelos Lineales
10.
Respiration ; 87(1): 32-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-23595051

RESUMEN

BACKGROUND: The diagnostic evaluation of patients presenting with possible lung cancer is often complex and time consuming. A rapid outpatient diagnostic program (RODP) including (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) and contrast-enhanced computed tomography (CT) as a routine diagnostic tool may improve timeliness, however the diagnostic performance of such a combined approach of RODP remains unclear. OBJECTIVES: We evaluated timeliness of care and diagnostic performance of FDG-PET and contrast-enhanced CT (FDG-PET/CT) in an RODP for all patients referred with a chest X-ray suspicious of lung cancer. METHODS: Charts of patients referred to the 2-day RODP of our tertiary care university clinic after an abnormal chest X-ray between 1999 and 2009 were reviewed. Between 1999 and 2005 co-registered FDG-PET and CT imaging took place; from September 2005 onwards, a hybrid system was used. We analyzed timeliness of care and diagnostic performance of FDG-PET/CT to differentiate malignant from benign lesions. RESULTS: In 386 patients available for analysis, 260 were diagnosed with lung cancer and 23 had another type of malignancy; in 78 patients benign disease was confirmed, and in another 45 the diagnosis was not pathologically confirmed but a median 24.5-month follow-up confirmed a benign outcome. Sensitivity, specificity, negative and positive predictive values and accuracy of FDG-PET/CT to differentiate lung cancer from benign disease were 97.7, 60.2, 92.5, 84.0 and 85.8%, respectively. Lung cancer patients had a median referral, diagnostic and therapeutic delay of 7, 2 and 19 days, respectively. CONCLUSIONS: FDG-PET/CT in an RODP setting for suspected lung cancer has high performance in detecting cancer and facilitates timely care.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Mesotelioma/diagnóstico , Imagen Multimodal , Tomografía de Emisión de Positrones , Carcinoma Pulmonar de Células Pequeñas/diagnóstico , Tomografía Computarizada por Rayos X , Anciano , Atención Ambulatoria , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Estudios de Cohortes , Medios de Contraste , Femenino , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Mesotelioma/diagnóstico por imagen , Mesotelioma Maligno , Persona de Mediana Edad , Radiofármacos , Estudios Retrospectivos , Sensibilidad y Especificidad , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen
11.
Eur J Radiol ; 82(12): 2399-405, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24113431

RESUMEN

OBJECTIVES: To assess the effect of bone suppression imaging on observer performance in detecting lung nodules in chest radiographs. MATERIALS AND METHODS: Posteroanterior (PA) and lateral digital chest radiographs of 111 (average age 65) patients with a CT proven solitary nodule (median diameter 15 mm), and 189 (average age 63) controls were read by 5 radiologists and 3 residents. Conspicuity of nodules on the radiographs was classified in obvious (n = 32), moderate (n = 32), subtle (n = 29) and very subtle (n = 18). Observers read the PA and lateral chest radiographs without and with an additional PA bone suppressed image (BSI) (ClearRead Bone Suppression 2.4, Riverain Technologies, Ohio) within one reading session. Multi reader multi case (MRMC) receiver operating characteristics (ROC) were used for statistical analysis. RESULTS: ROC analysis showed improved detection with use of BSI compared to chest radiographs alone (AUC = 0.883 versus 0.855; p = 0.004). Performance also increased at high specificities exceeding 80% (pAUC = 0.136 versus 0.124; p = 0.0007). Operating at a specificity of 90%, sensitivity increased with BSI from 66% to 71% (p = 0.0004). Increase of detection performance was highest for nodules with moderate and subtle conspicuity (p = 0.02; p = 0.03). CONCLUSION: Bone suppressed images improve radiologists' detection performance for pulmonary nodules, especially for those of moderate and subtle conspicuity.


Asunto(s)
Huesos/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Técnica de Sustracción , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Radiografía Torácica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
J Nucl Med ; 54(9): 1528-34, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23864719

RESUMEN

UNLABELLED: The potential of (18)F-FDG PET changes was evaluated for prediction of response to concomitant chemoradiotherapy in patients with locally advanced non-small cell lung cancer (NSCLC). METHODS: For 28 patients, (18)F-FDG PET was performed before treatment, at the end of the second week of treatment, and at 2 wk and 3 mo after the completion of treatment. Standardized uptake value (SUV), maximum SUV, metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Early metabolic changes were defined as fractional change (ΔTLG) when (18)F-FDG PET at the end of the second week was compared with pretreatment (18)F-FDG PET. In-treatment metabolic changes, as measured by serial (18)F-FDG PET, were correlated with standard criteria of response evaluation of solid tumors by means of CT imaging (Response Evaluation Criteria In Solid Tumors 1.1). Parameters were analyzed for stratification in progression-free survival (PFS). RESULTS: When compared with early metabolic nonresponders, a ΔTLG decrease of 38% or more was associated with a significantly longer PFS (1-y PFS 80% vs. 36%, P = 0.02). Pretreatment TLG was found to be a prognostic factor for PFS. CONCLUSION: The degree of change in TLG was predictive for response to concomitant chemoradiotherapy as early as the end of the second week into treatment for patients with locally advanced NSCLC. Pretreatment TLG was prognostic for PFS.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/terapia , Quimioradioterapia/métodos , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
13.
Lung Cancer ; 75(3): 336-41, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21943652

RESUMEN

INTRODUCTION: Delays in the diagnosis of lung cancer are under debate and may affect outcome. The objectives of this study were to compare various delays in a rapid outpatient diagnostic program (RODP) for suspected lung cancer patients with those described in literature and with guideline recommendations, to investigate the effects of referral route and symptoms on delays, and to establish whether delays were related to disease stage and outcome. METHODS: A retrospective chart study was conducted of all patients with suspected lung cancer, referred to the RODP of our tertiary care university clinic between 1999 and 2009. Patient characteristics, tumor stage and different delays were analyzed. RESULTS: Medical charts of 565 patients were retrieved. 290 patients (51.3%) were diagnosed with lung cancer, 48 (8.5%) with another type of malignancy, and in 111 patients (19.6%) the radiological anomaly was diagnosed as non-malignant. In 112 (19.8%) no immediate definite diagnosis was obtained, however in 82 of these cases (73.2%) the proposed follow-up strategy confirmed a benign outcome. The median first line delay was 54 days, IQR (interquartile range) 20-104 days, median patient delay 19 days (IQR 4-52 days), median referral delay was 7 days (IQR 5-9 days), median diagnostic delay 2 days (IQR 1-19 days). In 87% a diagnosis was obtained within 3 weeks after visiting a chest physician and 52.5% started curative therapy within 2 weeks after diagnosis. Patients presenting with hemoptysis had shorter first line delays. The RODP care was generally far more timely compared to literature and published guidelines, except for both referral and palliative therapeutic delay. No specific delay was significantly related to disease stage or survival. CONCLUSIONS: An RODP results in a timely diagnosis well within guideline recommendations. Patient and first line delay account for most of total patient delay. Within the limitations of this retrospective study, we found no association with disease stage or survival.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Anciano , Atención Ambulatoria , Broncoscopía , Femenino , Fluorodesoxiglucosa F18 , Directrices para la Planificación en Salud , Compuestos Heterocíclicos , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/terapia , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Estadificación de Neoplasias , Países Bajos , Compuestos Organometálicos , Tomografía de Emisión de Positrones , Derivación y Consulta , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
14.
Nat Rev Nephrol ; 6(3): 151-9, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20101256

RESUMEN

A reduction in the diameter of the renal arteries can lead to hypertension, renal dysfunction and/or pulmonary edema. About 90% of patients with renal artery stenosis have atherosclerosis, and 10% have fibromuscular dysplasia. Atherosclerotic renal artery stenosis is a common condition that typically occurs in patients at high risk of cardiovascular disease with coexistent vascular disease at nonrenal sites. Patients who undergo revascularization to treat hypertension associated with atherosclerotic stenosis need to continue medication with statins, antiplatelet agents and renin-angiotensin antagonists after the procedure to prevent renal and cardiovascular events. Two recent trials compared renal outcomes in patients with atherosclerotic stenosis who were treated with antihypertensive medication plus stenting with those in patients who were treated with medication alone. Available results favor a conservative approach (medication only) for most patients with atherosclerotic renal artery stenosis. These results, however, concern patients with stable clinical conditions and, in many cases, only moderate renal artery lesions. Blood pressure outcome after angioplasty is more favorable in patients with fibromuscular renal artery disease, who usually do not have renal failure, than in those with atherosclerosis.


Asunto(s)
Cateterismo/métodos , Diagnóstico por Imagen/métodos , Obstrucción de la Arteria Renal/diagnóstico , Obstrucción de la Arteria Renal/terapia , Angioplastia/efectos adversos , Angioplastia/métodos , Antihipertensivos/uso terapéutico , Progresión de la Enfermedad , Femenino , Humanos , Hipolipemiantes/uso terapéutico , Angiografía por Resonancia Magnética , Masculino , Selección de Paciente , Pronóstico , Obstrucción de la Arteria Renal/mortalidad , Medición de Riesgo , Índice de Severidad de la Enfermedad , Stents , Tasa de Supervivencia , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Vasodilatadores/uso terapéutico
15.
Ann Intern Med ; 150(12): 840-8, W150-1, 2009 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-19414832

RESUMEN

BACKGROUND: Little is known about the efficacy and safety of renal artery stenting in patients with atherosclerotic renal artery stenosis (ARAS) and impaired renal function. OBJECTIVE: To determine the efficacy and safety of stent placement in patients with ARAS and impaired renal function. DESIGN: Randomized clinical trial. Randomization was centralized and computer generated, and allocation was assigned by e-mail. Patients, providers, and persons who assessed outcomes were not blinded to treatment assignment. SETTING: 10 European medical centers. PARTICIPANTS: 140 patients with creatinine clearance less than 80 mL/min per 1.73 m(2) and ARAS of 50% or greater. INTERVENTION: Stent placement and medical treatment (64 patients) or medical treatment only (76 patients). Medical treatment consisted of antihypertensive treatment, a statin, and aspirin. MEASUREMENTS: The primary end point was a 20% or greater decrease in creatinine clearance. Secondary end points included safety and cardiovascular morbidity and mortality. RESULTS: Forty-six of 64 patients assigned to stent placement had the procedure. Ten of the 64 patients (16%) in the stent placement group and 16 patients (22%) in the medication group reached the primary end point (hazard ratio, 0.73 [95% CI, 0.33 to 1.61]). Serious complications occurred in the stent group, including 2 procedure-related deaths (3%), 1 late death secondary to an infected hematoma, and 1 patient who required dialysis secondary to cholesterol embolism. The groups did not differ for other secondary end points. LIMITATION: Many patients were falsely identified as having renal artery stenosis greater than 50% by noninvasive imaging and did not ultimately require stenting. CONCLUSION: Stent placement with medical treatment had no clear effect on progression of impaired renal function but led to a small number of significant procedure-related complications. The study findings favor a conservative approach to patients with ARAS, focused on cardiovascular risk factor management and avoiding stenting.


Asunto(s)
Aterosclerosis/complicaciones , Riñón/fisiopatología , Obstrucción de la Arteria Renal/fisiopatología , Obstrucción de la Arteria Renal/terapia , Stents , Anciano , Antihipertensivos/uso terapéutico , Aspirina/uso terapéutico , Atorvastatina , Terapia Combinada , Femenino , Ácidos Heptanoicos/uso terapéutico , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Masculino , Persona de Mediana Edad , Pirroles/uso terapéutico , Arteria Renal , Obstrucción de la Arteria Renal/etiología , Stents/efectos adversos
16.
Atherosclerosis ; 200(1): 184-90, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18241872

RESUMEN

AIM: To establish whether impaired renal function is an independent predictor of cardiovascular disease (CVD) and death in an unselected high-risk population with CVD. METHODS AND RESULTS: In 3216 patients with CVD, the estimated glomerular filtration rate (GFR) was assessed with the Modification of Diet in Renal Disease (MDRD)-equation. Primary outcomes were all vascular events (including stroke, myocardial infarction, end-stage renal disease and vascular death) and all cause death. During a median follow-up of 39 months, 378 patients had a vascular event (11.7%) and 337 patients died (10.5%). The adjusted hazard ratio (HR) of an estimated GFR90 ml/min per 1.73 m(2) was 1.8 (95% CI, 1.2-2.6) for vascular events and 1.4 (95% CI 0.9-2.0) for all cause death. For stroke and cardiac events as separate outcomes, similar HR's were found. Subgroup analysis according to localization of vascular disease at presentation or presence of the risk factors hypertension, diabetes and albuminuria had no influence on the hazard ratios. CONCLUSIONS: The presence of moderate to severe renal insufficiency is an independent risk factor for adverse CVD events in high-risk patients with a history of vascular disease. Localization of vascular disease or presence of other risk factors had no influence on the impact of renal function alone.


Asunto(s)
Enfermedad de la Arteria Coronaria/complicaciones , Insuficiencia Renal Crónica/complicaciones , Adulto , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Tasa de Filtración Glomerular , Encuestas Epidemiológicas , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Países Bajos/epidemiología , Estudios Prospectivos , Factores de Riesgo
17.
J Vasc Interv Radiol ; 16(6): 807-14, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15947044

RESUMEN

PURPOSE: To assess the validity and the direct, short-term, and long-term reproducibility of renal blood flow (RBF) measurements with phase-contrast (PC) magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 20 healthy volunteers, RBF measurements were repeated with and without repositioning. Internal validity was assessed by comparing the total RBF with the difference in aortic flow above and below the renal arteries. In 19 healthy volunteers, RBF measurements were performed at two different occasions. In 40 healthy volunteers, RBF measurements were performed to assess normal values as a function of age. Analyses were performed according to Bland and Altman. RESULTS: The technical success rate ranged from 78% to 85%. Total RBF and the difference in aortic flow rates showed good agreement (Pearson correlation coefficient, 0.72; P = .002). Directly repeated measurements had a mean difference of 54 mL/min in total RBF with a coefficient of variation (CV) of 17%. For repeated measurements with repositioning, the mean difference in total RBF was 74 mL/min (CV, 23%). Repeated measurements on different occasions showed a CV of 20%. The mean total RBF of the 40 healthy volunteers was 838 mL/min +/- 244 (SD). CONCLUSIONS: RBF measurement with PC MR has a success rate greater than 75%. The demonstrated internal reliability of this method and fair reproducibility of the flow parameters is crucial for further studies of the renal artery with MR imaging.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Circulación Renal/fisiología , Adulto , Anciano , Aorta/fisiología , Humanos , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados
18.
J Vasc Surg ; 38(5): 1060-6, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14603218

RESUMEN

OBJECTIVE: Peripheral arterial disease results in insufficient blood supply to the leg. Assessment of blood flow may provide information about severity of the disease. Magnetic resonance imaging (MRI) has potential use for simple, fast quantitative blood flow measurement. We investigated normal blood flow values for age and sex in the common femoral artery and popliteal artery in 50 healthy volunteers. In addition, we examined reproducibility and determinants of blood flow. METHODS: We performed cardiac-triggered phase-contrast quantitative flow measurements in the common femoral artery and popliteal artery, and MRI of the calves in 50 healthy volunteers (age, 26-80 years). Ten persons underwent MRI three times, to analyze reproducibility. RESULTS: All measurements were technically successful. Mean blood flow was 353 mL/min in the femoral artery and 61.9 mL/min in the popliteal artery. Coefficient of variation of femoral measurements was 16%, and of popliteal measurements was 19%. Femoral blood flow was significantly related to age and sex. Popliteal blood flow was significantly related to calf muscle volume, adjusted for age and sex. CONCLUSION: Normal values for blood flow to the legs are presented. The measurements have reasonable reproducibility. Blood flow to the legs depends on age, sex, and calf muscle volume.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Arteria Femoral/fisiología , Imagen por Resonancia Magnética/métodos , Arteria Poplítea/fisiología , Flujo Sanguíneo Regional/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pierna/irrigación sanguínea , Masculino , Reproducibilidad de los Resultados
19.
J Nephrol ; 16(6): 807-12, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14736007

RESUMEN

BACKGROUND: Atherosclerotic renal artery stenosis (ARAS) is associated with progressive loss of renal function and is one of the most important causes of renal failure in the elderly. Current treatment includes restoration of the renal arterial lumen by endovascular stent placement. However, this treatment only affects damage caused by ARAS due to the stenosis and ensuing post-stenotic ischemia. ARAS patients have severe general vascular disease. Atherosclerosis and hypertension can also damage the kidney parenchyma causing renal failure. Medical treatment focuses on the latter. Lipid-lowering drugs (statins) could reduce renal failure progression and could reduce the overall high cardiovascular risk. The additional effect on preserving renal function of stent placement as compared to medical therapy alone is unknown. Therefore, the STAR-study aims to compare the effects of renal artery stent placement together with medication vs. medication alone on renal function in ARAS patients. METHOD: Patients with an ARAS of > or = 50% and renal failure (creatinine (Cr) clearance < 80 mL/min/1.73 m2) are randomly assigned to stent placement with medication or to medication alone. Medication consists of statins, anti-hypertensive drugs and antiplatelet therapy. Patients are followed for 2 yrs with extended follow-up to 5 yrs. The primary outcome of this study is a reduction in Cr clearance > 20% compared to baseline. This trial will include 140 patients.


Asunto(s)
Antihipertensivos/uso terapéutico , Arteriosclerosis/terapia , Ácidos Heptanoicos/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Pirroles/uso terapéutico , Obstrucción de la Arteria Renal/terapia , Arteria Renal , Stents , Angioplastia de Balón , Arteriosclerosis/complicaciones , Arteriosclerosis/fisiopatología , Atorvastatina , Terapia Combinada , Progresión de la Enfermedad , Humanos , Riñón/fisiopatología , Obstrucción de la Arteria Renal/etiología , Obstrucción de la Arteria Renal/fisiopatología , Proyectos de Investigación
20.
J Vasc Interv Radiol ; 13(12): 1219-24, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12471185

RESUMEN

PURPOSE: To assess the long-term technical success of repeated endovascular intervention in stenosed renal artery stents. MATERIALS AND METHODS: Fifteen patients with stenoses >or=50% in a renal stent placed because of an ostial atherosclerotic renal artery stenosis were included in this study. In the presence of increased blood pressure or decreased renal function, the in-stent restenosis was treated with percutaneous transluminal angioplasty (PTA) in the stent or placement of a second stent if the stenosis was located too distally in the stent. The results of these repeat interventions were evaluated by angiography. RESULTS: The 15 patients had a total of 20 stenosed stents. Eighteen of these in-stent stenoses were treated with PTA and two were treated with placement of a second stent. Angiographic follow-up was available in 16 arteries, showing in-stent restenosis in four (25%; mean follow-up, 11 mo). The cumulative patency rates after repeat endoluminal intervention were 93% (95% CI: 80%-106%) and 76% (95% CI: 52%-101%) after 6 and 12 months, respectively. Renal function remained stable or improved in most patients (80%) after repeated intervention in the stent, and hypertension was classified as improved or cured in 47% of patients after 1 year. CONCLUSION: Patients with stenosed renal artery stents can be treated successfully with PTA in a majority of cases, with a long-term success rate of 75% and stable renal function 1 year after repeated intervention.


Asunto(s)
Angioplastia de Balón , Obstrucción de la Arteria Renal/terapia , Stents , Falla de Equipo , Femenino , Humanos , Riñón/irrigación sanguínea , Riñón/fisiopatología , Riñón/cirugía , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Recurrencia , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...