1.
J Clin Microbiol ; 56(8)2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29875193

RESUMEN

The accuracy and robustness of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid-medium systems using patient samples. This is the first report to demonstrate that proteins within the liquid medium, its supplements, and decontamination reagents for nonsterile patient samples do not generate misidentification or false-positive results by use of the Vitek MS v3.0 system. Prior to testing with patient samples, a seeded-culture study was conducted to challenge the accuracy of the Vitek MS system at identifying mycobacteria from liquid medium by mimicking a clinical workflow. Seventy-seven Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated, inoculated into BacT/Alert MP liquid culture medium, incubated until positivity, and identified using the Vitek MS system. A total of 383 liquid cultures were tested, of which 379 (99%) were identified correctly to the species/complex/group level, 4 (1%) gave a "no-identification" result, and no misidentifications were observed. Following the simulated-sputum study, a total of 73 smear-positive liquid-medium cultures detected using BD BBL MGIT and VersaTREK Myco liquid media were identified by the Vitek MS system. Sixty-four cultures (87.7%) were correctly identified to the species/complex/group level; 7 (9.6%) resulted in no identification; and 2 (2.7%) were misidentified at the species level. These results indicate that the Vitek MS v3.0 system is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures.


Asunto(s)
Técnicas Bacteriológicas/métodos , Infecciones por Mycobacterium no Tuberculosas/diagnóstico , Mycobacterium/clasificación , Mycobacterium/aislamiento & purificación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Técnicas Bacteriológicas/instrumentación , Medios de Cultivo , Pruebas Diagnósticas de Rutina , Humanos , Mycobacterium/química , Esputo/microbiología
2.
J Clin Microbiol ; 56(6)2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29643203

RESUMEN

This multicenter study was designed to assess the accuracy and reproducibility of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry system for identification of Mycobacterium and Nocardia species compared to DNA sequencing. A total of 963 clinical isolates representing 51 taxa were evaluated. In all, 663 isolates were correctly identified to the species level (69%), with another 231 (24%) correctly identified to the complex or group level. Fifty-five isolates (6%) could not be identified despite repeat testing. All of the tuberculous mycobacteria (45/45; 100%) and most of the nontuberculous mycobacteria (569/606; 94%) were correctly identified at least to the group or complex level. However, not all species or subspecies within the M. tuberculosis, M. abscessus, and M. avium complexes and within the M. fortuitum and M. mucogenicum groups could be differentiated. Among the 312 Nocardia isolates tested, 236 (76%) were correctly identified to the species level, with an additional 44 (14%) correctly identified to the complex level. Species within the N. nova and N. transvalensis complexes could not always be differentiated. Eleven percent of the isolates (103/963) underwent repeat testing in order to get a final result. Identification of a representative set of Mycobacterium and Nocardia species was highly reproducible, with 297 of 300 (99%) replicates correctly identified using multiple kit lots, instruments, analysts, and sites. These findings demonstrate that the system is robust and has utility for the routine identification of mycobacteria and Nocardia in clinical practice.


Asunto(s)
Mycobacterium tuberculosis/aislamiento & purificación , Nocardia/aislamiento & purificación , Micobacterias no Tuberculosas/aislamiento & purificación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Mycobacterium tuberculosis/genética , Nocardia/genética , Nocardiosis/diagnóstico , Nocardiosis/microbiología , ARN Ribosómico 16S/genética , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Tuberculosis/diagnóstico , Tuberculosis/microbiología
3.
Infect Control Hosp Epidemiol ; 34(6): 625-30, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23651895

RESUMEN

On June 13, 2012, a group of key stakeholders, leaders, and national experts on tuberculosis (TB), occupational health, and laboratory science met in Atlanta, Georgia, to focus national discussion on the higher than expected positive results occurring among low-risk, unexposed healthcare workers undergoing serial testing with interferon-γ release assays (IGRAs). The objectives of the meeting were to present the latest clinical and operational research findings on the topic, to discuss evaluation and treatment algorithms that are emerging in the absence of national guidance, and to develop a consensus on the action steps needed to assist programs and physicians in the interpretation of serial testing IGRA results. This report summarizes its proceedings.


Asunto(s)
Ensayos de Liberación de Interferón gamma/normas , Salud Laboral , Guías de Práctica Clínica como Asunto , Tuberculosis/diagnóstico , Sector de Atención de Salud , Humanos , Curva ROC , Tuberculosis/tratamiento farmacológico , Tuberculosis/prevención & control , Estados Unidos