Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Dent Res ; 97(3): 266-274, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29073362

RESUMEN

In aesthetic sites, the integrity of the facial bone wall dimension in the anterior maxilla is jeopardized by physiologic and structural changes postextraction. An effective regenerative protocol is key to reestablish and maintain the hard and soft tissue dimensions over time. The present prospective case series study examined the effectiveness of early implant placement with simultaneous contour augmentation through guided bone regeneration with a 2-layer composite graft in postextraction single-tooth sites over an observation period of 10 y among 20 patients. The median peri-implant bone loss was 0.35 mm between the 1- and 10-y examination. A success rate of 95% was obtained, with pleasing aesthetic outcomes and a high median Pink Esthetic Score (8). Implant crowns (ICs) revealed significant median facial recession between IC10y and IC1y (0.17 mm). The facial bone wall dimensions were assessed by preoperative cone beam computed tomography and 2 subsequent scans taken at 6 and 10 y. The median facial bone wall thickness increased significantly from 0 mm at surgery to 1.67 mm at the 10-y examination. The facial vertical bone wall peak (DIC) was located at a median distance of 0.16 mm coronal to the implant shoulder. The facial vertical bone loss of DIC amounted to 0.02 mm between 6 and 10 y. Equivalence testing was performed for the null hypothesis of a difference of >0.2 mm per year between 2 respective time points, showing stable bone conditions. Modulating factors influencing the regenerative outcomes at 10 y were the preoperative proximal crest width and soft tissue thickness. In conclusion, the present study confirmed the long-term effectiveness of early implant placement with simultaneous contour augmentation through guided bone regeneration with a 2-layer composite graft in postextraction single-tooth sites offering stable bone conditions with low risks of mucosal recessions over an observation period of 10 y ( ClinicalTrials.gov NCT03252106).


Asunto(s)
Aumento de la Cresta Alveolar/métodos , Implantación Dental Endoósea/métodos , Implantes Dentales de Diente Único , Regeneración Tisular Guiada Periodontal , Adulto , Anciano , Regeneración Ósea/fisiología , Sustitutos de Huesos/uso terapéutico , Tomografía Computarizada de Haz Cónico , Estética Dental , Femenino , Humanos , Masculino , Maxilar , Persona de Mediana Edad , Oseointegración/fisiología , Estudios Prospectivos , Extracción Dental , Alveolo Dental/cirugía , Resultado del Tratamiento , Dimensión Vertical
2.
J Dent Res ; 96(2): 163-170, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27927884

RESUMEN

Patients' esthetic expectations are increasing, and the options of the prosthetic pathways are currently evolving. The objective of this randomized multicenter clinical trial was to assess and compare the esthetic outcome and clinical performance of anterior maxillary all-ceramic implant crowns (ICs) based either on prefabricated zirconia abutments veneered with pressed ceramics or on CAD/CAM zirconia abutments veneered with hand buildup technique. The null hypothesis was that there is no statistically significant difference between the 2 groups. Forty implants were inserted in sites 14 to 24 (FDI) in 40 patients in 2 centers, the Universities of Bern and Geneva, Switzerland. After final impression, 20 patients were randomized into group A, restored with a 1-piece screw-retained single crown made of a prefabricated zirconia abutment with pressed ceramic as the veneering material using the cut-back technique, or group B using an individualized CAD/CAM zirconia abutment (CARES abutment; Institut Straumann AG) with a hand buildup technique. At baseline, 6 mo, and 1 y clinical, esthetic and radiographic parameters were assessed. Group A exhibited 1 dropout patient and 1 failure, resulting in a survival rate of 94.7% after 1 y, in comparison to 100% for group B. No other complications occurred. Clinical parameters presented stable and healthy peri-implant soft tissues. Overall, no or only minimal crestal bone changes were observed with a mean DIB (distance from the implant shoulder to the first bone-to-implant contact) of -0.15 mm (group A) and 0.12 mm (group B) at 1 y. There were no significant differences at baseline, 6 mo, and 1 y for DIB values between the 2 groups. Pink esthetic score (PES) and white esthetic score (WES) values at all 3 examinations indicated stability over time for both groups and pleasing esthetic outcomes. Both implant-supported prosthetic pathways represent a valuable treatment option for the restoration of single ICs in the anterior maxilla ( ClinicalTrials.gov NCT02905838).


Asunto(s)
Diseño Asistido por Computadora , Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar/métodos , Prótesis Dental de Soporte Implantado/métodos , Estética Dental , Circonio , Adulto , Fracaso de la Restauración Dental , Femenino , Humanos , Masculino , Resultado del Tratamiento
3.
J Dent Res ; 92(12 Suppl): 176S-82S, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24158332

RESUMEN

In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.


Asunto(s)
Aumento de la Cresta Alveolar/métodos , Implantes Dentales de Diente Único , Adulto , Proceso Alveolar/diagnóstico por imagen , Regeneración Ósea/fisiología , Sustitutos de Huesos/uso terapéutico , Trasplante Óseo/métodos , Tomografía Computarizada de Haz Cónico/métodos , Coronas , Índice de Placa Dental , Diseño de Prótesis Dental , Estética Dental , Estudios de Seguimiento , Encía/patología , Recesión Gingival/clasificación , Regeneración Tisular Guiada Periodontal/métodos , Humanos , Imagenología Tridimensional/métodos , Estudios Longitudinales , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Membranas Artificiales , Oseointegración/fisiología , Bolsa Periodontal/clasificación , Estudios Prospectivos , Radiografía de Mordida Lateral , Resultado del Tratamiento , Adulto Joven
4.
Dentomaxillofac Radiol ; 42(2): 20110429, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23360688

RESUMEN

OBJECTIVES: Conventional panoramic radiography, a widely used radiographic examination tool in implant treatment planning, allows evaluation of the available bone height before inserting posterior mandibular implants. Image distortion and vertical magnification due to projection geometry is well described for rotational panoramic radiographs. To assess the accuracy of vertical height measurements on direct digital panoramic radiographs, implants and metal balls positioned in the posterior mandible were used as radio-opaque reference objects. The reproducibility of the measuring method was assessed by the inter- and intraobserver agreements. METHODS: Direct digital panoramic radiographs, performed using a Kodak 8000C (Eastman Kodak Company, Rochester, NY), of 17 partially edentulous patients (10 females, 7 males, mean age 65 years) were selected from an X-ray database gathered during routine clinical evaluation of implant sites. Proprietary software and a mouse-driven calliper were used to measure the radiological length of 25 implants and 18 metal reference balls, positioned in mandibular posterior segments. The distortion ratio (DR) was calculated by dividing the radiological implant length by the implant's real length and the radiological ball height by the ball's real height. RESULTS: Mean vertical DR was 0.99 for implants and 0.97 for balls, and was unrelated to mandibular sites, side, age, gender or observer. Inter- and intraobserver agreements were acceptable for both reference objects. CONCLUSIONS: Vertical measurements had acceptable accuracy and reproducibility when a software-based calibrated measurement tool was used, confirming that digital panoramic radiography can be reliably utilized to determine the pre-operative implant length in premolar and molar mandibular segments.


Asunto(s)
Cefalometría/estadística & datos numéricos , Implantes Dentales , Marcadores Fiduciales , Mandíbula/diagnóstico por imagen , Radiografía Dental Digital/estadística & datos numéricos , Radiografía Panorámica/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Aleaciones/química , Cefalometría/normas , Medios de Contraste , Arco Dental/diagnóstico por imagen , Diseño de Prótesis Dental , Femenino , Marcadores Fiduciales/clasificación , Humanos , Arcada Parcialmente Edéntula/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Planificación de Atención al Paciente , Intensificación de Imagen Radiográfica/normas , Radiografía Dental Digital/normas , Radiografía Panorámica/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Programas Informáticos
5.
J Dent Res ; 90(2): 251-6, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21149858

RESUMEN

The ability to use autologous dental progenitor cells (DPCs) to form organized periodontal tissues on titanium implants would be a significant improvement over current implant therapies. Based on prior experimental results, we hypothesized that rat periodontal ligament (PDL)-derived DPCs can be used to bioengineer PDL tissues on titanium implants in a novel, in vivo rat maxillary molar implant model. Analyses of recovered implants revealed organized PDL tissues surrounding titanium implant surfaces in PDL-cell-seeded, and not in unseeded control, implants. Rat PDL DPCs also exhibited differentiative potential characteristic of stem cells. These proof-of-principle findings suggest that PDL DPCs can organize periodontal tissues in the jaw, at the site of previously lost teeth, indicating that this method holds potential as an alternative approach to osseointegrated dental implants. Further refinement of this approach will facilitate the development of clinically relevant methods for autologous PDL regeneration on titanium implants in humans.


Asunto(s)
Células Madre Adultas , Implantes Dentales , Ligamento Periodontal/citología , Regeneración , Ingeniería de Tejidos/métodos , Andamios del Tejido , Animales , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Colágeno , Ensayo de Unidades Formadoras de Colonias , Cemento Dental/fisiología , Combinación de Medicamentos , Femenino , Laminina , Osteocalcina/biosíntesis , Ligamento Periodontal/fisiología , Proteoglicanos , Ratas , Ratas Endogámicas Lew , Titanio
6.
Clin Oral Implants Res ; 15(2): 239-48, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15008937

RESUMEN

A number of algorithms have been proposed to model the adaptive behavior of bone under load. However, the predictions of several models have neither been compared nor have they been systematically related to in vivo data. To this end, the stress states of loaded implant-bone interfaces were analyzed before and after osseointegration using finite element (FE) techniques. In a preliminary step, an FE mesh of a cylindrical implant encased in a cancellous core surrounded by a cortical layer was constructed, and the stresses and strains that developed at the interface were determined. The implant was loaded with 100 N vertical and 30 N lateral loads. Using this structure, the peak compressive and tensile stresses were determined. Then bone remodeling predictions were assessed using three different models: von Mises equivalent strain, strain energy density and effective stress. Finally, a systematic search of the literature was conducted to relate the numerical predictions to existing in vivo data. The FE simulations led to the following conclusions: (1) calculated compressive stresses were lower than the ultimate compressive stresses of cortical and cancellous bone. (2) Calculated tensile stresses were generally superior to experimental data on the tensile strength of the bone-implant interface. (3) With one exception, the predictions of all models were homogeneously grouped on the stimulus scales. (4) The predictions of the models as to bone gain or loss were not consistent and at times contradictory. It is hypothesized that this effect is linked to a lazy zone that is too narrow. With respect to the application of the numerical models to in vivo data, peak strains and strain energy densities were consistent with in vivo data. No in vivo data were found that supported effective stress as a stimulus.


Asunto(s)
Proceso Alveolar/fisiología , Remodelación Ósea , Implantación Dental Endoósea , Implantes Dentales , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Adaptación Fisiológica , Animales , Fuerza Compresiva , Análisis del Estrés Dental/métodos , Elasticidad , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Estrés Mecánico , Resistencia a la Tracción , Soporte de Peso
7.
J Periodontal Res ; 37(4): 237-44, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12200965

RESUMEN

This study is part of a research program that aims to develop a constitutive three-dimensional model of the periodontal ligament (PDL) through the identification of pertinent material parameters. As part of this program, bovine PDL was utilized to establish stress-strain responses under tensile and compressive loading conditions. Fresh bovine molars were secured, frozen and prepared to appropriate dimensional specifications. Bar-shaped specimens that comprised portions of dentine, PDL and bone were produced. Push-pull tests were conducted using a specifically constructed loading machine. Full range monotonic stress-strain diagrams were generated. The effect of a rate increase on cyclic S-E diagrams was also determined. The influence of specimen thickness was expressed in terms of modulus of elasticity, strength, uniaxial maximizer strain, and strain energy density. The overall load-response was heavily hysteretic in compression. On the tensile side, after a steep rise, the curve tended to flatten out asymptotically. Variations in rate that spanned four orders of magnitude had no effect on reciprocal load responses. The E-modulus was in the 4-8 MPa range, the strength of the PDL was 1-2 MPa, the maximizer strain was at 45-60% and the strain energy density ranged between 0.3 and 0.4 MPa.


Asunto(s)
Ligamento Periodontal/fisiología , Proceso Alveolar/anatomía & histología , Proceso Alveolar/fisiología , Análisis de Varianza , Animales , Fenómenos Biomecánicos , Bovinos , Fuerza Compresiva , Análisis del Estrés Dental/instrumentación , Dentina/anatomía & histología , Dentina/fisiología , Elasticidad , Microscopía de Polarización , Ligamento Periodontal/anatomía & histología , Estrés Mecánico , Temperatura , Resistencia a la Tracción , Soporte de Peso
8.
Dent Mater ; 18(5): 389-95, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12175578

RESUMEN

OBJECTIVE: The aim of the study was to determine the Weibull distribution parameters S(0) and m of the tensile bond strength of a composite resin sandwiched between a noble metal alloy and a feldspathic porcelain using the Rocatec system. METHODS: Specimens were prepared either as Au-Pt-Pd alloy cylinders alone or as alloy cylinders and a feldspathic porcelain. Surface treatments included 110 microm Al(2)O(3) sandblasting (Rocatec Pre), tribochemical silica coating (Rocatec Plus) and silane application (ESPE-Sil) prior to composite bonding. The tensile bond strengths of ceramic-resin-ceramic and metal-resin-metal specimens were determined before and after thermocycling at 5-60 degrees C for 1000 cycles. Statistical analyses were conducted using two parameter Weibull distributions determined by the characteristic strength (S(0)) at the 63% probability of failure, the Weibull modulus (m) and the 95% confidence intervals. RESULTS: With respect to the control group (no Rocatec) (7.5MPa), the Rocatec system significantly augmented the characteristic tensile bond strength S(0) of metal (17-18MPa) and porcelain (20-28MPa) groups. Thermocycling had no effect on the tensile bond strength of the metal samples and increased (not significant) the bond of the porcelain group. The Weibull modulus m for all groups ranged from 2.8 to 3.7. SIGNIFICANCE: This study confirmed the efficacy of the Rocatec system for bonding composite resin to metal or ceramic substrates. However, the variability of the strength of the bond is shown in the low Weibull modulus values obtained. This reflect the difficulties in controlling flaw formation and warrants research for future improvement.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales , Porcelana Dental , Aleaciones de Cerámica y Metal , Análisis de Falla de Equipo , Aleaciones de Oro , Funciones de Verosimilitud , Modelos Lineales , Ensayo de Materiales , Silanos , Propiedades de Superficie , Análisis de Supervivencia , Resistencia a la Tracción
9.
Am J Dent ; 14(2): 72-80, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11507803

RESUMEN

PURPOSE: To determine Kaplan-Meier survival estimates and Weibull lifetime predictions for four all-ceramic crown systems from long-term data (> 5 yrs). MATERIALS AND METHODS: Single unit crowns of Cerestore (n = 30), Dicor (n = 30), Hi-Ceram (n = 22) and In-Ceram (n = 68) were placed in 95 patients treated in a university clinic. They were cemented using glass-ionomer (GI) for Cerestore, zinc phosphate (ZP) for Dicor, and 75% ZP (n = 51), 20% GI (n = 13) and 5% resin-based cement (n = 4) for In-Ceram crowns. The follow-up times were 8 yrs for Cerestore, 7 yrs for Dicor, 6 yrs for Hi-Ceram and 5 yrs for In-Ceram. The statistical analyses were based on censored data sets. A progressively censored Weibull distribution allowing for lifetime predictions beyond the actual observation time was used as well as the Kaplan-Meier Survival Product Limit Estimate (PLE), which provides survival estimates up to the maximum time of follow-up. RESULTS: Cerestore, Dicor and Hi-Ceram demonstrated molar fractures in the first 2 yrs, whereas for In-Ceram these occurred during the third and fourth year of the study. The Kaplan-Meier Survival PLE was 69% for Cerestore at 8 yrs, 86% for Dicor at 7 yrs, 81% for Hi-Ceram at 6 yrs, 92% for In-Ceram at 5 yrs. The predicted Weibull characteristic time T0 (time at which 63% of the restorations would have failed) was 23 yrs for Cerestore, 34 yrs for Dicor, 31 yrs for Hi-Ceram, and 16 yrs for In-Ceram. However, when using data sets arbitrarily limited to the three first years of follow-up, T0 decreased significantly for Cerestore, Dicor and Hi-Ceram due to the number of early fractures. Such Weibull lifetime data illustrate the risk of predicting long-term (> 5 yrs) survival using short-term (< or = 3 yrs) data on ceramic restorations, which exhibit fracturing in the initial years.


Asunto(s)
Coronas , Porcelana Dental , Fracaso de la Restauración Dental , Óxido de Aluminio , Humanos , Análisis de Supervivencia
10.
Dent Mater ; 17(4): 367-71, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11356215

RESUMEN

OBJECTIVES: The low fusing dental glass (Duceram LFC) has been advertised as presenting a superior chemical resistance and augmented strength after 16h exposure to water or 4% acetic acid. The purpose of this study was to evaluate the effect of prolonged exposure to water on two mechanical properties (fracture toughness and flexure strength) of LFC. METHODS: Disks and bars were mirror polished and annealed prior to aging in: (1) air (control), (2) water for 24h at 80 degrees C and (3) water for 8 weeks at 80 degrees C. Fracture toughness (K(Ic)) was determined by indentation fracture (IF) and indentation strength (IS) using a 19.6N Vickers indentation load. Flexure strength values were obtained from three-point bending at 0.1mm/min. Statistical analysis was performed using the Weibull distribution, Tukey and Bartlett tests (P<0.05). RESULTS: Both techniques (IS and IF) showed a significant improvement in the K of Duceram LFC after 8 weeks in water (0.88 and 1.14MPa m(0.5)) as opposed to the 24-h values both in water and air (0.77-0.78MPa m(0.5)). However, for flexure strength the Weibull characteristic (S(0)) and the m parameter did not change significantly with water storage (S(0)=90-100MPa, Weibull m =7-8). SIGNIFICANCE: The increase in toughness of Duceram LFC after aging in water is an interesting and favorable observation for a restorative material exposed to the oral environment. Nevertheless, in comparison with other contemporary ceramics, the toughness of this LFC remains in the range of soda-lime-glass or classic feldspar porcelains.


Asunto(s)
Materiales Dentales/química , Porcelana Dental/química , Vidrio/química , Agua/química , Ácido Acético/química , Aire , Silicatos de Aluminio/química , Cerámica/química , Pulido Dental , Dureza , Calor , Humanos , Ensayo de Materiales , Docilidad , Compuestos de Potasio/química , Estadística como Asunto , Estrés Mecánico , Propiedades de Superficie , Factores de Tiempo
11.
Int J Prosthodont ; 14(1): 40-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11842903

RESUMEN

PURPOSE: Microstructural analyses of commercially pure titanium (CpTi) are scarce. The present report presents the micrographs, fractographs, elemental characteristics, and hardness profiles of brazed joints and weldments using machined rods of CpTi. MATERIALS AND METHODS: CpTi rods were joined using four techniques: laser welding, electric-arc welding, electron-beam welding, and gold- and Ti-filler brazing. The specimens were then subjected to tensile and fatigue loading. After sectioning and patterning, optical micrographs of intact joints were obtained. Fractured surfaces were investigated using scanning electron microscopy (SEM). The joint's composition was determined by SEM-energy dispersive x-ray analysis. Hardness was determined at specific locations using a microindenter. RESULTS: While laser welding left the parent metal's equiaxed structure fairly intact, electric-arc welding, electron-beam welding, and brazing created a heat-affected zone in the vicinity of the joint. The extent and characteristics of the heat-affected zone depended on the amount of heat transferred to the specimens. In this respect, brazing essentially increased grain size and altered their shape. Electron-beam welding augmented this phenomenon, yielding grains that encompassed the full diameter of the joint. Electric-arc welding disrupted the granular pattern and generated highly lamellar/acicular structures. CONCLUSION: Hardness was not a good indicator of mechanical resistance, nor was the joint's structural continuity with the parent substrate. Still, acicular microstructures were characterized by a peculiar behavior in that such joints were highly resistant to tensile stresses while their fatigue strength ranged among the lowest of the joints tested.


Asunto(s)
Soldadura Dental , Titanio/química , Cobre/química , Soldadura Dental/métodos , Electricidad , Electroquímica , Microanálisis por Sonda Electrónica , Electrones , Aleaciones de Oro/química , Dureza , Calor , Humanos , Rayos Láser , Microscopía Electrónica de Rastreo , Níquel/química , Tamaño de la Partícula , Platino (Metal)/química , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción , Titanio/análisis
12.
J Mater Sci Mater Med ; 12(8): 719-25, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15348244

RESUMEN

This study aimed at determining whether data previously gathered for a laser welds and IR brazings using a Au-Pd alloy were applicable to titanium joints. As to its resistance under fatigue loading, Au-Pd alloy had shown a poor response to pre-ceramic laser welding and post-ceramic brazing. The present study was designed to assess the mechanical resistance, the microstructure and the elemental diffusion of laser welded, electric arch welded and brazed joints using commercially pure titanium as substrate metal. Mechanical resistance was determined by determining the joints' ultimate tensile strength and their resistance to fatigue loading. Elemental diffusion to and from the joints was assessed using microprobe tracings. Optical micrographs of the joints were also obtained and evaluated. Under monotonic tensile stress, three groups emerged: (1) the GTAW and the native (i.e. as received) substrate, (2) the annealed substrate and the laser welds and (3) the brazed joints. Under fatigue stress, the order was: first the native and annealed substrate, second the brazings and laser welds, third the GTAW joints. No Au-filler brazing withstood the applied fatigue loading. The micrographs showed various patterns, an absence of HAZ cracking and several occurrences of Widmanstätten structures. Elemental diffusion to and from the Ti substrate was substantial in the Ti filler brazings and virtually nil in the Au-based brazings. Under fatigue stress application, the titanium-based brazings as well as the laser- and electric arc welds performed equally well if not better than a previously tested AuPd alloy. There was a definite increase in grain size with increased heat application. However, no feature of the microstructures observed or the elemental analysis could be correlated with the specimen's resistance to fatigue stress application.

13.
Int J Oral Maxillofac Implants ; 15(4): 519-26, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10960985

RESUMEN

This paper presents aa comparison between the 8-degree Morse Taper and the butt joint aa connections between an implant and an abutment. Three-dimensional, non-linear finite element models were created to compare the 2 connection principles under equal conditions. The loading configuration was thereby modeled according to a test setup actually used for the dynamic long-term testing of dental implants as required for regulatory purposes. The results give insight into the mechanics involved in each type of connection and are compared to actual findings with the testing machine. The comparison indicates the superior mechanics of conical abutment connections and helps to explain their significantly better long-term stability in the clinical application.


Asunto(s)
Pilares Dentales , Implantes Dentales , Diseño de Prótesis Dental , Retención de Prótesis Dentales/instrumentación , Prótesis Dental de Soporte Implantado , Implantación Dental Endoósea , Análisis del Estrés Dental/métodos , Estudios de Evaluación como Asunto , Análisis de Elementos Finitos , Humanos , Estrés Mecánico
14.
J Biomed Mater Res ; 53(4): 362-70, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10898877

RESUMEN

Resin-based laboratory dental composites for prosthetic restorations have been developed in the past years as a cost-effective alternative to conventional porcelain-fused-to-metal or full ceramic restorations. The fracture toughness at different stress states (K(Ic), K(IIc), and mixed-modes K(I), K(II) ) was assessed for three laboratory dental composite resins used for prosthetic restorations that were aged up to 12 months in a food simulating fluid (10% ethanol) at 37 degrees C. The materials were mainly di- methacrylate based resins reinforced with submicron glass filler particles. The Brazilian disk test was used on precracked chevron-notched specimens, and different stress states were obtained by angulating the precracked chevron notch relative to the diametral compressive loading direction. The stress intensity factors were calculated using Atkinson et al.'s relation. For all three materials, mode I fracture toughness values ranged between 0.48-0.64 MPa. m(0.5) and mode II values ranged between 0.93-1.2 MPa. m(0.5). Overall, aging time and storage media had little effect on toughness. Considering the inherently low toughness of these restorative materials, their use should be limited to low stress masticatory areas.


Asunto(s)
Resinas Compuestas , Óxido de Aluminio , Bario , Cementos de Ionómero Vítreo , Humanos , Metacrilatos , Cemento de Silicato , Dióxido de Silicio , Propiedades de Superficie
15.
Dent Mater ; 16(3): 218-25, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10762683

RESUMEN

OBJECTIVES: To design a novel technique to assess the wear of prosthodontic veneering materials. Further to determine whether accurate transfer between the oral cavity and the measuring device is achievable and assess the reproducibility of the coordinates generated by the measuring system. METHODS: The system is based on the repositioning capacity of an octagonal connector of the ITI implant system. The same type of connector was screwed onto the clinical implants that supported the experimental restorations and secured to the x-y table of the measuring device. The measuring setup also comprised a z-axis LVDT displacement gauge that allowed the entire surface of the restorations to be profiled and digitized. The system was under the control of a PC equipped with custom-made software that set the position of the stepping motors, lifted and lowered the z-axis probe, and registered and wrote the x-, y- and z-axis coordinates. Final numerical adjustments and analyses were performed using a commercial array-oriented software package. Validation procedures were performed using a specially designed calibration surface. RESULTS: On repeated profile tracings, the measurement error was less than 2 microns. When the calibration surface was removed between measurements as during clinical trials, the measurement error increased to ca. 5 microns. SIGNIFICANCE: The measurement error of the testing procedure including transfer to and from the mouth is +/- 5 microns.


Asunto(s)
Coronas , Prótesis Dental de Soporte Implantado , Alisadura de la Restauración Dental , Calibración , Gráficos por Computador , Intervalos de Confianza , Implantes Dentales , Coronas con Frente Estético , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Microcomputadores , Polimetil Metacrilato , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Propiedades de Superficie
16.
Clin Oral Implants Res ; 11 Suppl 1: 126-45, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11168262

RESUMEN

The aim of this chapter is to discuss the current prosthetic management of the partially dentate patient by means of fixed implant restorations in the scope of the ITI(R) Dental Implant System. For that purpose, the related statements defined by the participants of the prosthodontic section of the 1997 ITI Consensus Conference in Vitznau, Switzerland, will be presented, completed by explanatory comments where appropriate. Distinct conceptual differences will be made between the esthetic zone (areas of the dental arches where esthetic considerations are of primary concern) and the non-esthetic zone (regions of the jaws where esthetic aspects do not represent a priority), and between single tooth replacement and multiple unit implant restorations. Furthermore, it is underlined that current clinical concepts should be based on both predictable treatment outcome and cost-effectiveness. In this context, a straightforward surgical and prosthetic protocol is generally preferred in posterior locations of the oral cavity, using a nonsubmerged implant placement comprising an easily accessible implant shoulder location, and subsequently cemented implant restorations, basically according to a traditional prosthodontic approach. In esthetically demanding indications, where normally a distinctly submucosal implant shoulder location is advocated, screw-retained restorations are preferred, based on prefabricated prosthetic components (e.g. machined cast-on copings) to assure optimum surface properties and contour, and to achieve adequate marginal adaptation.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Arcada Parcialmente Edéntula/rehabilitación , Diente Premolar , Implantes Dentales de Diente Único , Diseño de Prótesis Dental , Retención de Prótesis Dentales/instrumentación , Retención de Prótesis Dentales/métodos , Estética Dental , Humanos , Incisivo , Arcada Parcialmente Edéntula/cirugía , Diente Molar
17.
Int J Periodontics Restorative Dent ; 20(5): 440-57, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11203582

RESUMEN

The present study evaluated the clinical performance of bonded porcelain veneers (PV) restoring substantial coronal volume and length in the anterior dentition. Forty-eight PVs were placed in 16 patients, with systematic coverage and reconstitution of the incisal edge, including well-defined anterior guidance. A standardized protocol comprising diagnostic steps that integrate additive waxups and acrylic mockups was used. PVs were fabricated using feldspathic and low-fusing porcelains in a refractory die technique. Incisal overlaps featured freestanding porcelain spans ranging from 1.5 to 5.5 mm. After a mean clinical service of 4.5 years, 13 clinical parameters for each tooth and 4 parameters that applied to persons were recorded. Permutation tests evaluated the effects of margin location, incisal edge span of porcelain, overbite, opposing contact location, and restoration age on ceramic failure and clinical marginal adaptation and seal. At recall, 100% of the veneers were satisfactory with minor interventions. The effect of slight marginal defects and porcelain cracking was negligible. Biologic, periodontal, and esthetic parameters showed excellent results, which were supported by 100% patient-reported satisfaction. All patients felt comfortable with the newly defined anterior guidance. Aging was negligible, and there were no significant effects of margin location (P > 0.08), incisal edge span of the ceramic, or overbite (P > 0.22) on ceramic failure and marginal performance. Minor alterations of the palatal margin, however, tended to be more frequent compared to facial locations, and were found especially when the opposing tooth contact in centric occlusion was located on the palatal margin (P = 0.028). Bonded ceramic restorations represent a reliable, effective procedure to restore extensive coronal volume and length in the anterior dentition.


Asunto(s)
Porcelana Dental , Diseño de Prótesis Dental , Coronas con Frente Estético , Estética Dental , Resinas Acrílicas , Adolescente , Adulto , Silicatos de Aluminio/química , Diente Premolar , Diente Canino , Recubrimiento Dental Adhesivo , Técnica de Colado Dental , Oclusión Dental Céntrica , Porcelana Dental/química , Fracaso de la Restauración Dental , Femenino , Estudios de Seguimiento , Humanos , Incisivo , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Compuestos de Potasio/química , Propiedades de Superficie , Fracturas de los Dientes/terapia
19.
J Prosthet Dent ; 81(3): 327-34, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10050122

RESUMEN

STATEMENT OF PROBLEM: Anterior teeth are especially subject to the thermal variations of ingested food and drinks. Postoperative cracks of porcelain laminates are considered a possible consequence of polymerization shrinkage, function, and thermocycling. PURPOSE: This investigation was conducted to define the parameters associated with the development of cracks in porcelain veneers using cyclic thermal fatigue. MATERIAL AND METHODS: Twenty-seven maxillary incisors were restored with porcelain laminate veneers and subjected to thermocycling (5 degrees C to 50 degrees C) for 1000 cycles. Ceramic cracks were reported for 11 of the 27 specimens. Teeth were sectioned and prepared for SEM analysis. Measurements of the ceramic and the luting composite thicknesses were performed for each specimen at different restoration locations (facial, incisal, and proximal). RESULTS: No significant differences in the ceramic or the luting composite thicknesses were observed between cracked and uncracked specimens. However, significant differences were observed in the ratio of the ceramic and luting composite thicknesses. Most cracked samples exhibited a ratio at the facial location below 3.0 (2.6 +/- 0.35), whereas most noncracked specimens were above this value (3.9 +/- 0.19). Incisal and especially proximal measurements alone were not significantly different between cracked versus uncracked specimens. Ceramic was slightly thinner in the facial aspect than in the proximal aspect, which was also thinner than the incisal aspect. Composite in the facial aspect was thinner in the cervical area than in the incisal third of the tooth. CONCLUSIONS: Significant cyclic temperature changes can induce the development of flaws in porcelain veneers. Control of tooth reduction and the application of die spacers during laboratory procedures undoubtedly represent key elements; a sufficient and even thickness of ceramic combined with a minimal thickness of luting composite will provide the restoration with a favorable configuration with regard to crack propensity, namely, a ceramic and luting composite thickness ratio above 3.


Asunto(s)
Porcelana Dental , Fracaso de la Restauración Dental , Coronas con Frente Estético , Análisis de Varianza , Bebidas , Fenómenos Químicos , Química Física , Resinas Compuestas/química , Porcelana Dental/química , Diseño de Prótesis Dental , Alimentos , Humanos , Incisivo/ultraestructura , Modelos Lineales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Polímeros/química , Cementos de Resina/química , Propiedades de Superficie , Temperatura , Termodinámica
20.
Int J Prosthodont ; 12(3): 255-62, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10635194

RESUMEN

PURPOSE: The aim of the present study was to assess the effect of cement-film thickness and surface texture (roughness) on the resistance of cemented crowns to dynamic lateral loading. MATERIALS AND METHODS: Crown and abutment analogues were cemented using zinc-oxide-eugenol, zinc-phosphate, glass-ionomer, and composite cements. The space left for the cement lute was 0.02, 0.05, 0.1, 0.2, and 0.5 mm. The 3 degrees of surface texture subjected to investigation were (1) polished with up to 4,000-grit paper, (2) sanded using a 1,000-grit paper, and (3) sandblasted with 50-micron aluminum oxide. Testing was conducted according to the staircase procedure. The specimens were subjected to rotational fatigue loading until the cement bond failed or the components reached 1,000,000 stress cycles. RESULTS: The results showed that the relation between cement thickness and resistance to dynamic lateral loading is hyperbolic. For the zinc-oxide-eugenol, the zinc-phosphate, and the glass-ionomer cements increasing surface texture had a moderate effect. For composite cement, sandblasting doubled the resistance to dynamic lateral loading. For both parameters tested (cement thickness and surface texture), the ascending order of resistance was: zinc-oxide-eugenol, zinc-phosphate, and glass-ionomer cements. Crowns cemented with composite cement presented the highest resistance to dynamic lateral loading. CONCLUSION: Within the confines of the present experimental design, it is concluded that (1) decreasing the width of the cement layer increases the resistance to dynamic lateral loading, and (2) texturing the surface of the abutment and the restorations as after sandblasting increases the resistance to dynamic lateral loading.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Análisis del Estrés Dental , Cementación , Coronas , Pilares Dentales , Cementos de Ionómero Vítreo , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Cemento de Óxido de Zinc-Eugenol , Cemento de Fosfato de Zinc
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...