Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Asunto principal
Intervalo de año de publicación
1.
J Clin Diagn Res ; 10(1): ZC37-41, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26894173

RESUMEN

AIM: To compare the retentive ability and deformation of Acetal resin with Cobalt-Chromium clasps via Insertion Removal apparatus after subjecting them to stimulate clinical use. MATERIALS AND METHODS: Materials used for this study are commercially available Cobalt-Chromium alloy namely Wironit, Bego, Germany and Acetal resin namely Biodentaplast, Bredent, Germany. The test samples were divided into two major groups based on the type of materials used in the study. Each major group is further subdivided into two sub groups based on the retentive undercut depths used to engage the clasps. So a total of 20 specimens were prepared, comprising of 5 specimens in each sub group. Then the specimens were tested for retention force and deformation. RESULTS: The results of this study indicate that acetal resin clasps are resistant to deformation and may offer a clinical advantage over the conventional metal clasps. The retentive force of acetal resin clasps did not decrease over the cycling periods. This would be attributed to the resilient nature of acetal resin. Under the conditions of the present study cobalt chromium clasps lost retentive force within 730 cycles of placement and removal and continued to lose retentive force during the remaining test period. CONCLUSION: This invitro study demonstrated that retentive force of cobalt chromium clasp is superior to that of Acetal resin for removable partial dentures. As acetal resin clasps exhibits greater flexibility and long term retentive resiliency, it can be used for removable partial dentures where aesthetics or periodontal health is a primary concern.

2.
Indian J Ophthalmol ; 56(1): 67-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18158408

RESUMEN

Congenital anomalies of the lens include a wide range from lens coloboma to primary aphakia and doubling of lens. There have been few case reports of double lens; the etiology suggested is metaplastic changes in the surface ectoderm that leads to formation of two lens vesicles and hence resulting in double lens. We report a case with bilobed lens, which raises the possibility of explaining the etiology of double lens.


Asunto(s)
Cristalino/anomalías , Adolescente , Coloboma/complicaciones , Humanos , Iris/anomalías , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA