Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 120(9): 097201, 2018 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-29547324

RESUMEN

We report the discovery of a field driven transition from a single-q to multi-q spin density wave (SDW) in the tetragonal heavy fermion compound CeAuSb_{2}. Polarized along c, the sinusoidal SDW amplitude is 1.8(2)µ_{B}/Ce for T≪T_{N}=6.25(10) K with a wave vector q_{1}=(η,η,1/2) [η=0.136(2)]. For H∥c, harmonics appearing at 2q_{1} evidence a striped magnetic texture below µ_{∘}H_{1}=2.78(1) T. Above H_{1}, these are replaced by coupled harmonics at q_{1}+q_{2}=(2η,0,0)+c^{*} until µ_{∘}H_{2}=5.42(5) T, where satellites vanish and magnetization nonlinearly approaches saturation at 1.64(2)µ_{B}/Ce for µ_{∘}H≈7 T.

2.
Rev Sci Instrum ; 89(1): 015105, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29390677

RESUMEN

The continuous angle multiple energy analysis concept is a backend for both time-of-flight and analyzer-based neutron spectrometers optimized for neutron spectroscopy with highly efficient mapping in the horizontal scattering plane. The design employs a series of several upward scattering analyzer arcs placed behind each other, which are set to different final energies allowing a wide angular coverage with multiple energies recorded simultaneously. For validation of the concept and the model calculations, a prototype was installed at the Swiss neutron source SINQ, Paul Scherrer Institut. The design of the prototype, alignment and calibration procedures, experimental results of background measurements, and proof-of-concept inelastic measurements on LiHoF4 and h-YMnO3 are presented here.

3.
Sci Adv ; 3(5): e1602055, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28560326

RESUMEN

The application of magnetic fields, chemical substitution, or hydrostatic pressure to strongly correlated electron materials can stabilize electronic phases with different organizational principles. We present evidence for a field-induced quantum phase transition, in superconducting Nd0.05Ce0.95CoIn5, that separates two antiferromagnetic phases with identical magnetic symmetry. At zero field, we find a spin-density wave that is suppressed at the critical field µ0H* = 8 T. For H > H*, a spin-density phase emerges and shares many properties with the Q phase in CeCoIn5. These results suggest that the magnetic instability is not magnetically driven, and we propose that it is driven by a modification of superconducting condensate at H*.


Asunto(s)
Campos Magnéticos , Modelos Teóricos , Superconductividad
4.
Rev Sci Instrum ; 87(3): 035109, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27036821

RESUMEN

The analyzer detector system continuous angle multiple energy analysis will be installed on the cold-neutron triple-axis spectrometer RITA-2 at SINQ, PSI. CAMEA is optimized for efficiency in the horizontal scattering plane enabling rapid and detailed mapping of excitations. As a novelty the design employs a series of several sequential upward scattering analyzer arcs. Each arc is set to a different, fixed, final energy and scatters neutrons towards position sensitive detectors. Thus, neutrons with different final energies are recorded simultaneously over a large angular range. In a single data-acquisition many entire constant-energy lines in the horizontal scattering plane are recorded for a quasi-continuous angular coverage of about 60°. With a large combined coverage in energy and momentum, this will result in a very efficient spectrometer, which will be particularly suited for parametric studies under extreme conditions with restrictive sample environments (high field magnets or pressure cells) and for small samples of novel materials. In this paper we outline the concept and the specifications of the instrument currently under construction.

5.
Rev Sci Instrum ; 84(5): 055106, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23742588

RESUMEN

We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3-5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA