Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Robot ; 9(87): eadh0298, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38354258

RESUMEN

Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician's skill and the device's ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device's surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.


Asunto(s)
Robótica , Humanos , Animales , Porcinos , Movimiento (Física) , Fenómenos Magnéticos
2.
Anaesthesia ; 75(7): 881-886, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31900928

RESUMEN

Robotic endoscope-automated via laryngeal imaging for tracheal intubation (REALITI) has been developed to enable automated tracheal intubation. This proof-of-concept study using a convenience sample of participants, comprised of trained anaesthetists and lay participants with no medical training, assessed the performance of a robotic device for the insertion of a tracheal tube into a manikin. A prototype robotic endoscope device was inserted into the trachea of an airway manikin by seven anaesthetists and seven participants with no medical training. Each individual performed six device insertions into the trachea in manual mode and six in automated mode. The anaesthetists succeeded with 40/42 (95%) manual insertions (median (IQR [range]) 17 (12-26 [4-132]) s) and 40/42 (95%) automated insertions (15 (13-18 [7-25]) s). The non-trained participants succeeded in 41/42 (98%) manual insertions (median (IQR [range]) 18 (13-21 [8-133]) s) and 42/42 (100%) automated insertions (16 (13-23 [10-58])] s). The duration of insertion did not differ between groups. An effect of increasing experience was observed in both groups in manual mode. A Likert scale for 'ease of use' (0 = very difficult to 10 = very easy) showed similar results within the two groups; the mean (SD) was 5.9 (2.1) for the anaesthetists and 6.9 (1.3) for the non-trained participants. We have successfully performed the first automated tracheal device insertion in a manikin with comparable results in a convenience sample of anaesthetists and lay participants with no medical training.


Asunto(s)
Intubación Intratraqueal/instrumentación , Laringoscopios , Robótica/instrumentación , Adulto , Competencia Clínica , Femenino , Humanos , Intubación Intratraqueal/métodos , Masculino , Maniquíes , Prueba de Estudio Conceptual , Robótica/métodos , Factores de Tiempo , Interfaz Usuario-Computador , Grabación en Video/métodos , Adulto Joven