Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Blood Rev ; 31(6): 400-405, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28755795

RESUMEN

As the main iron transporter, transferrin delivers iron to target tissues like the bone marrow for erythropoiesis. Also, by binding free iron, transferrin prevents formation of reactive oxygen species. Transferrin deficiency due to congenital hypotransferrinemia is characterized by anemia as well as oxidative stress related to toxic free iron. Transferrin supplementation may be beneficial in two ways. First, transferrin can correct anemia by modulating the amount of iron that is available for erythropoiesis. This is obvious for patients that suffer from hypotransferrinemia, but may also have beneficial effects for ß-thalassemia patients. Second, under conditions of iron overload, transferrin reduces oxidative stress by binding free iron in the circulation and in tissues. Hereby, transferrin protects the host against the reactive oxygen species that can be formed as a consequence of free iron. This beneficial effect is shown in hematological patients undergoing chemotherapy and stem cell transplantation. Transferrin may also be beneficial in lung injury, ischemia-reperfusion injury and hypomyelination. This review summarizes the preclinical and clinical data on the efficacy of exogenous transferrin administration to modulate certain forms of anemia and to prevent the toxic effects of free iron. Thereby, we show that transferrin has promising therapeutic potential in a wide variety of conditions.


Asunto(s)
Anemia/tratamiento farmacológico , Transferrina/uso terapéutico , Anemia/metabolismo , Animales , Enfermedades Desmielinizantes/tratamiento farmacológico , Enfermedades Desmielinizantes/metabolismo , Humanos , Hiperoxia/tratamiento farmacológico , Hiperoxia/metabolismo , Sobrecarga de Hierro/tratamiento farmacológico , Sobrecarga de Hierro/metabolismo , Lesión Pulmonar/tratamiento farmacológico , Lesión Pulmonar/metabolismo , Degeneración Macular/tratamiento farmacológico , Degeneración Macular/metabolismo , Estrés Oxidativo/efectos de los fármacos , Daño por Reperfusión/tratamiento farmacológico , Daño por Reperfusión/metabolismo , Trasplante de Células Madre/métodos , Talasemia beta/tratamiento farmacológico , Talasemia beta/metabolismo
3.
Ann Intensive Care ; 6(1): 68, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27436191

RESUMEN

BACKGROUND: Microdialysis is a well-established technology that can be used for continuous blood glucose monitoring. We determined point and trend accuracy, and reliability of a microdialysis-based continuous blood glucose-monitoring device (EIRUS(®)) in critically ill patients. METHODS: Prospective study involving patients with an expected intensive care unit stay of ≥48 h. Every 15 min, device readings were compared with blood glucose values measured in arterial blood during blocks of 8 h per day for a maximum of 3 days. The Clarke error grid, Bland-Altman plot, mean absolute relative difference and glucose prediction error analysis were used to express point accuracy and the rate error grid to express trend accuracy. Reliability testing included aspects of the device and the external sensor, and the special central venous catheter (CVC) with a semipermeable membrane for use with this device. RESULTS: We collected 594 paired values in 12 patients (65 [26-80; 8-97] (median [IQR; total range]) paired values per patient). Point accuracy: 93.6 % of paired values were in zone A of the Clarke error grid, 6.4 % were in zone B; bias was 4.1 mg/dL with an upper limit of agreement of 28.6 mg/dL and a lower level of agreement of -20.5 mg/dL in the Bland-Altman analysis; 93.6 % of the values ≥75 mg/dL were within 20 % of the reference values in the glucose prediction error analysis; the mean absolute relative difference was 7.5 %. Trend accuracy: 96.4 % of the paired values were in zone A, and 3.3 and 0.3 % were in zone B and zone C of the rate error grid. Reliability: out of 16 sensors, 4 had to be replaced prematurely; out of 12 CVCs, two malfunctioned (one after unintentional flushing by unsupervised nurses of the ports connected to the internal microdialysis chamber, causing rupture of the semipermeable membrane; one for an unknown reason). Device start-up time was 58 [56-67] min; availability of real-time data was 100 % of the connection time. CONCLUSIONS: In this study in critically ill patients who had no hypoglycemic episodes and a limited number of hyperglycemic excursions, point accuracy of the device was moderate to good. Trend accuracy was very good. The device had no downtimes, but 4 out of 16 external sensors and 2 out of 12 CVCs had practical problems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...