1.
J Pharm Biomed Anal ; 246: 116215, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759319

RESUMEN

Peripherally inserted central catheters (PICC-lines) used in neonatology are made of thermoplastic polyurethane (TPU) or silicone. These materials usually contain substances that may leach into drug vehicles or blood. In this extractables study, we determined the optimal extraction conditions using TPU films containing defined amounts of butylhydroxytoluene (BHT) and then applied them on unused and explanted PICC-lines. Maceration and sonication tests were carried out with hexane, acetone and water as the extraction solvents. The analyses were performed using gas and liquid chromatography coupled with mass spectrometry detectors, as well as inductive coupled plasma optical emission spectroscopy to detect a wide range of extractables. We selected a limited list of substances to be sought from the usual adjuvants and monomers, related to their carcinogenic, mutagenic or reprotoxic properties and/or existence in endocrine disruptors lists. The TPU-film experiments showed that acetone was slightly better than hexane, and maceration better than sonication. When applied to PICC-lines, the extraction methods were almost similar but acetone was clearly better than hexane for TPU. From the 48 peaks initially observed in GC-MS, we ended up with 37 peaks to follow in TPU PICC-lines, among which were those of BHT and 4,4'-Methylenebis(cyclohexyl isocyanate) isomers. For silicone PICC-lines, out of 41 peaks initially observed in GC-MS, we followed 20 peaks, most of them being identified as cyclosiloxanes. Barium was the main inorganic element extracted for both PICC-lines. For TPU PICC-lines, the inter-batch variability was higher than for intra-batch, but in silicone devices both were similar. When compared to new PICC-lines, explanted TPU PICC-lines extracted peaks had a lower area under the curve (AUC), while the AUCs of the peaks were higher for the majority of silicone PICC-lines extract compounds. No identified substances were detected above their toxicological threshold, but isocyanates and cyclosiloxanes toxicity was mostly studied for other exposition routes than intravenous. The methods defined in this study were efficient in producing extractable profiles from both PICC-lines.


Asunto(s)
Catéteres Venosos Centrales , Cromatografía de Gases y Espectrometría de Masas , Poliuretanos , Poliuretanos/química , Humanos , Recién Nacido , Cromatografía de Gases y Espectrometría de Masas/métodos , Siliconas/química , Solventes/química , Cateterismo Periférico/métodos , Sonicación/métodos
2.
Int J Pharm ; 643: 123254, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37473975

RESUMEN

Medical devices (MD) are often made of plasticized polyvinylchloride (PVC). However, plasticizers may leach out into infused solutions and expose the patients to a toxic risk. The aim of the present work is to fluorinate plasticized PVC tubular MDs to create a barrier layer on their internal surface, and to study the impact of such a chemical treatment on the migration of the plasticizers. Following fluorination by pure molecular fluorine, the physico-chemical characterization of these modified MDs was carried out using various spectroscopic and microscopic techniques or tensile tests, evidencing the formation of covalent C-F bonds on the surface of the treated samples without modification of their mechanical and optical properties. The migration of plasticizers from fluorinated MDs was assessed using gas chromatography coupled with mass spectrometry and was found considerably decreased in comparison with the pristine MDs. After 24 h, the amount of tri-octyltrimellitate plasticizer (TOTM) detected in migrates from fluorinated MDs was even lower than the limit of quantification. Complementary cytotoxicity assays were performed according to the ISO EN 10993-5 standard, showing that the new fluorinated material does not cause a cytotoxic effect on L929 cells.


Asunto(s)
Dietilhexil Ftalato , Plastificantes , Humanos , Plastificantes/química , Halogenación , Cromatografía de Gases y Espectrometría de Masas/métodos , Cloruro de Polivinilo/química , Espectrometría de Masas , Dietilhexil Ftalato/toxicidad , Dietilhexil Ftalato/análisis , Dietilhexil Ftalato/química
3.
Pharmaceutics ; 15(3)2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36986615

RESUMEN

Pentobarbital is a drug of choice to limit motion in children during paediatric procedural sedations (PPSs). However, despite the rectal route being preferred for infants and children, no pentobarbital suppositories are marketed, and therefore they must be prepared by compounding pharmacies. In this study, two suppository formulations of 30, 40, 50, and 60 mg of pentobarbital sodium were developed using hard-fat Witepsol® W25 either alone (formulation F1) or with oleic acid (formulation F2). The two formulations were subjected to the following tests described in the European Pharmacopoeia: uniformity of dosage units, softening time, resistance to rupture, and disintegration time. The stability of both formulations was also investigated for 41 weeks of storage at 5 ± 3 °C using a stability-indicating liquid chromatography method to quantify pentobarbital sodium and research breakdown product (BP). Although both formulae were compliant to uniformity of dosage, the results were in favour of a faster disintegration of F2 compared to F1 (-63%). On the other hand, F1 was found to be stable after 41 weeks of storage unlike F2 for which several new peaks were detected during the chromatographic analysis, suggesting a shorter stability of only 28 weeks. Both formulae still need to be clinically investigated to confirm their safety and efficiency for PPS.

4.
Sci Rep ; 12(1): 8959, 2022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35624232

RESUMEN

Stability studies are essential to be able to assign an expiration date to medications. Color variation is one of the organoleptic characteristics of actives substances or medications which can indicate the presence of contaminations, impurities or degradations products. However there is no data available comparing the often used visual examination with spectrophotometric measurements during stability studies. The aim of this study was therefore to evaluate precisely how different the two methods are, by comparing the change of color of two drug formulations chosen as models, assessed by visual examination versus a spectrophotometric colorimetric analysis. Paracetamol and parenteral nutrition solutions were stored in stress conditions for up to 46 days, and were subjected to a visual examination using color reference solutions and to lightness and chromaticity measurement to determine their specific color by UV-Vis spectrophotometry. The color of paracetamol solutions changed faster when exposed to stress condition (light), as did the PNS when exposed to heat. In both cases, color variations were detected earlier and more precisely by UV-Vis spectrophotometry than by visual examination. Color measurement using an UV-Vis spectrophotometry should advantageously replace visual examination when assessing colors changes during drug stability studies.


Asunto(s)
Acetaminofén , Estabilidad de Medicamentos , Color , Colorimetría , Espectrofotometría
5.
Front Bioeng Biotechnol ; 10: 818201, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35419353

RESUMEN

There is a growing body of evidences that brain surrogates will be of great interest for researchers and physicians in the medical field. They are currently mainly used for education and training purposes or to verify the appropriate functionality of medical devices. Depending on the purpose, a variety of materials have been used with specific and accurate mechanical and biophysical properties, More recently they have been used to assess the biocompatibility of implantable devices, but they are still not validated to study the migration of leaching components from devices. This minireview shows the large diversity of approaches and uses of brain phantoms, which converge punctually. All these phantoms are complementary to numeric models, which benefit, reciprocally, of their respective advances. It also suggests avenues of research for the analysis of leaching components from implantable devices.

6.
Pharmaceutics ; 14(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35057013

RESUMEN

Tacrolimus is an immunosuppressant used to treat a large variety of inflammatory or immunity-mediated ophthalmic diseases. However, there are currently no commercial industrial forms available that can provide relief to patients. Various ophthalmic formulations have been reported in the literature, but their stability has only been tested over short periods. The objective of this study was to evaluate the physicochemical stability of a preservative-free tacrolimus formulation (0.2 and 1 mg/mL) at three storage temperatures (5 °C, 25 °C and 35 °C) for up to nine months in a multidose eyedropper. Analyses performed were the following: visual inspection and chromaticity, turbidity, viscosity, size of micelles, osmolality and pH measurements, tacrolimus quantification by a stability-indicating liquid chromatography method, breakdown product research, and sterility assay. In an in-use study, tacrolimus quantification was also performed on the drops emitted from the eyedroppers. All tested parameters remained stable during the nine month period when the eyedrops were stored at 5 °C. However, during storage at 25 °C and 35 °C, several signs of chemical instability were detected. Furthermore, a leachable compound originating from a silicone part of the eyedropper was detected during the in-use assay. Overall, the 0.2 mg/mL and 1 mg/mL tacrolimus ophthalmic solutions were physicochemically stable for up to nine months when stored at 5 °C.

7.
Int J Mol Sci ; 22(19)2021 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-34638878

RESUMEN

Ceftazidime (CZ) and vancomycin (VA) are two antibiotics used to treat bacterial keratitis. Due to their physical incompatibility (formation of a precipitate), it is not currently possible to associate both molecules in a single container for ophthalmic administration. We firstly characterized the incompatibility then investigated if 2-hydroxypropyl-beta (HPßCD) and 2-hydroxypropyl-gamma cyclodextrins (HPγCD) could prevent this incompatibility. The impact of pH on the precipitation phenomena was investigated by analysing the supernatant solution of the mixture using high performance liquid chromatography. A characterization of the inclusion of CZ with HPγCD using 1H nuclear magnetic resonance (NMR), and VA with HPßCD using 1H-NMR and a solubility diagram was performed. A design of experiment was built to determine the optimal conditions to obtain a formulation that had the lowest turbidity and particle count. Our results showed that VA and CZ form an equimolar precipitate below pH 7.3. The best formulation obtained underwent an in-vitro evaluation of its antibacterial activity. The impact of HPCDs on incompatibility has been demonstrated through the inclusion of antibiotics and especially VA. The formulation has been shown to be able to inhibit the incompatibility for pH higher than 7.3 and to possess unaltered antibacterial activity.


Asunto(s)
Antibacterianos/química , Ceftazidima/química , Composición de Medicamentos , Infecciones Bacterianas del Ojo/tratamiento farmacológico , Queratitis/tratamiento farmacológico , Vancomicina/química , gamma-Ciclodextrinas/química , Antibacterianos/farmacología , Ceftazidima/farmacología , Humanos , Queratitis/microbiología , Vancomicina/farmacología
9.
Front Bioeng Biotechnol ; 9: 657875, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34178958

RESUMEN

INTRODUCTION: Although deep brain stimulation is nowadays performed worldwide, the biomechanical aspects of electrode implantation received little attention, mainly as physicians focused on the medical aspects, such as the optimal indication of the surgical procedure, the positive and adverse effects, and the long-term follow-up. We aimed to describe electrode deformations and brain shift immediately after implantation, as it may highlight our comprehension of intracranial and intracerebral mechanics. MATERIALS AND METHODS: Sixty electrodes of 30 patients suffering from severe symptoms of Parkinson's disease and essential tremor were studied. They consisted of 30 non-directional electrodes and 30 directional electrodes, implanted 42 times in the subthalamus and 18 times in the ventrolateral thalamus. We computed the x (transversal), y (anteroposterior), z (depth), torsion, and curvature deformations, along the electrodes from the entrance point in the braincase. The electrodes were modelized from the immediate postoperative CT scan using automatic voxel thresholding segmentation, manual subtraction of artifacts, and automatic skeletonization. The deformation parameters were computed from the curve of electrodes using a third-order polynomial regression. We studied these deformations according to the type of electrodes, the clinical parameters, the surgical-related accuracy, the brain shift, the hemisphere and three tissue layers, the gyration layer, the white matter stem layer, and the deep brain layer (type I error set at 5%). RESULTS: We found that the implanted first hemisphere coupled to the brain shift and the stiffness of the type of electrode impacted on the electrode deformations. The deformations were also different according to the tissue layers, to the electrode type, and to the first-hemisphere-brain-shift effect. CONCLUSION: Our findings provide information on the intracranial and brain biomechanics and should help further developments on intracerebral electrode design and surgical issues.

10.
Metabolites ; 11(4)2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-33921860

RESUMEN

Care management of newborns in the neonatal intensive care unit (NICU) requires numerous PVC (PolyVinyl Chloride) medical devices (MD) containing plasticizers that can migrate and contaminate the patient. We measured the magnitude of neonates' exposure to plasticizers (di-ethylhexylphthalate (DEHP) and alternatives) in relation to urinary concentrations of their metabolites. Plasticizers' exposure was evaluated (1) by calculating the amounts of plasticizers prone to be released from each MD used for care management, and (2) by measuring the patients' urinary levels of each plasticizers' metabolites. 104 neonates were enrolled. They were exposed to di-isononylphthalate (DINP), especially via transfusion and infusion MD, and to DEHP via ECMO (Extra Corporeal Membrane Oxygenation) and respiratory assistance MD. Mean exposure doses exceeded the derived no-effect level of DINP and DEHP by a 10-fold and a 1000-fold factor. No PVC MD were plasticized with di-isononylcyclohexane-1,2-dicarboxylate (DINCH). High urinary concentrations of DEHP metabolites were directly correlated with DEHP exposure through ECMO MD. Urinary concentrations of DINP metabolites in transfused patients were also high. DINCH metabolites were found in urine, suggesting another route of exposure. Neonates in NICU are considerably exposed to plasticizers, with magnitudes varying with the type of MD used. The high exposure to DEHP and DINP leads to a risk of their metabolites' toxicity.

11.
Pharmaceutics ; 12(9)2020 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-32825121

RESUMEN

Fungal keratitis is a sight-threatening disease for which amphotericin B eye drops is one of the front-line treatments. Unfortunately, there are currently no commercial forms available, and there is little data concerning the long-term stability of compounded formulations based on intravenous dosages forms. New formulations of amphotericin B ophthalmic solutions solubilised with γ-cyclodextrins have shown promising in-vitro results, but stability data is also lacking. The objective of this study was therefore to investigate the stability of a formulation of ready-to-use amphotericin B solubilised in 2-hydroxypropyl-γ-cyclodextrins (AB-HP-γ-CD), for 350 days. An amphotericin B deoxycholate (ABDC) formulation was used as a comparator. Analyses used were the following: visual inspection, turbidity, osmolality and pH measurements, amphotericin B quantification by a stability-indicating liquid chromatography method, breakdown product research, and sterility assay. AB-HP-γ-CD formulation showed signs of chemical instability (loss of amphotericin B) after 28 and 56 days at 25 °C and 5 °C. Adding an antioxidant (ascorbic acid) to the formulation did not improve stability. ABDC formulation showed signs of physical instability (increased turbidy and amphotericin B precipitation) after 28 days and 168 days at 25 °C and 5 °C. As such, AB-HP-γ-CD formulation does not provide long-term stability for ophthalmic amphotericin B solutions.

12.
Pharmaceutics ; 12(8)2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32824572

RESUMEN

Myopia is an ophthalmic condition affecting more than 1/5th of the world population, especially children. Low-dose atropine eyedrops have been shown to limit myopia evolution during treatment. However, there are currently no commercial industrial forms available and there is little data published concerning the stability of medications prepared by compounding pharmacies. The objective of this study was to evaluate the stability of two 0.1 mg/mL atropine formulations (with and without antimicrobiobial preservatives) for 6 months in two different low-density polyethylene (LDPE) multidose eyedroppers. Analyses used were the following: visual inspection, turbidity, chromaticity measurements, osmolality and pH measurements, atropine quantification by a stability-indicating liquid chromatography method, breakdown product research, and sterility assay. In an in-use study, atropine quantification was also performed on the drops emitted from the multidose eyedroppers. All tested parameters remained stable during the 6 months period, with atropine concentrations above 94.7% of initial concentration. A breakdown product (tropic acid) did increase slowly over time but remained well below usually admitted concentrations. Atropine concentrations remained stable during the in-use study. Both formulations of 0.1 mg/mL of atropine (with and without antimicrobial preservative) were proved to be physicochemically stable for 6 months at 25 °C when stored in LDPE bottles, with an identical microbial shelf-life.

13.
Chemosphere ; 255: 126978, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32417514

RESUMEN

Bis(2-ethylhexyl) phthalate (DEHP) migration from polyvinyl chloride (PVC) has been studied with infusion, transfusion and extracorporeal oxygenation devices, but no study has been conducted to estimate its migration via respiratory medical devices (MDs). This work aims to develop an ex vivo model to quantify DEHP released doses by these MDs, which will then be used to estimate newborns DEHP exposure from respiratory assistance MDs. We followed the Frensh National Research and Safety Institute (INRS) recommendations for the validation of a collecting and analysing method of DEHP in air, which will be used to quantify DEHP in air passing through PVC respiratory assistance MDs. The developed method met all the validation criteria for DEHP determination in air. DEHP in air passing through MDs on the sixth day reached a cumulative quantity of 122.86 µg when using a flow rate of 4 L min-1 of non-humidified air while it was of 49.22 µg; 58.12 µg and 29.61 µg with flow rates of 2 L min-1 of humidified air, 2 L min-1 of dry air and 4 L min-1 of humidified air, respectively. Model application to two patients undergoing two different respiratory procedure demonstrated that noninvasive ventilation patient received higher dose of inhaled DEHP, confirmed by DEHP metabolites quantification in urine. Although the protective effect of air humidifiers on DEHP exposure was demonstrated, the effect of flow rate is difficult to be established. This developed method should be tested to verify its capacity to collect and quantify other plasticizers used in PVC MDs.


Asunto(s)
Dietilhexil Ftalato/análisis , Exposición a Riesgos Ambientales/análisis , Equipos y Suministros/efectos adversos , Ventiladores Mecánicos/efectos adversos , Dietilhexil Ftalato/metabolismo , Humanos , Recién Nacido , Plastificantes/análisis , Cloruro de Polivinilo/análisis , Cloruro de Polivinilo/química , Dispositivos de Autoayuda/efectos adversos
14.
PeerJ ; 6: e4549, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29682408

RESUMEN

BACKGROUND: Polyhexamethylene biguanide (PHMB) eye drops are a frequently used medication to treat Acanthamoeba keratitis. In the absence of marketed PHMB eye drops, pharmacy-compounding units are needed to prepare this much needed treatment, but the lack of validated PHMB stability data severely limits their conservation by imposing short expiration dates after preparation. In this study we aim to assess the physicochemical and microbiological stability of a 0.2 mg/mL PHMB eye drop formulation stored in two kinds of polyethylene bottles at two different temperatures. METHODS: A liquid chromatography coupled with diode array detector stability-indicating method was validated to quantify PHMB, using a cyanopropyl bonded phase (Agilent Zorbax Eclipse XDB-CN column 4.6 × 75 mm with particle size of 3.5 µm) and isocratic elution consisting of acetonitrile/deionized water (3/97 v/v) at a flow rate of 1.3 mL/min. PHMB eye drops stability was assessed for 90 days of storage at 5 and 25 °C in ethylene oxide sterilized low density polyethylene (EOS-LDPE) and gamma sterilized low density polyethylene (GS-LDPE) bottles. The following analyses were performed: visual inspection, PHMB quantification and breakdown products (BPs) screening, osmolality and pH measurements, and sterility assessment. PHMB quantification and BP screening was also performed on the drops emitted from the multidose eyedroppers to simulate in-use condition. RESULTS: The analytical method developed meets all the qualitative and quantitative criteria for validation with an acceptable accuracy and good linearity, and is stability indicating. During 90 days of storage, no significant decrease of PHMB concentration was found compared to initial concentration in all stored PHMB eye drops. However, BP were found at day 30 and at day 90 of monitoring in both kind of bottles, stored at 5 and 25 °C, respectively. Although no significant variation of osmolality was found and sterility was maintained during 90 days of monitoring, a significant decrease of pH in GS-LDPE PHMB eye drops was noticed reaching 4 and 4.6 at 25 °C and 5 °C respectively, compared to initial pH of 6.16. DISCUSSION: Although no significant decrease in PHMB concentration was found during 90 days of monitoring in all conditions, the appearance of BPs and their unknown toxicities let us believe that 0.2 mg/mL PHMB solution should be conserved for no longer than 60 days in EOS-LDPE bottles at 25 °C.

15.
PLoS One ; 13(2): e0192369, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29474357

RESUMEN

Infusion medical devices (MDs) used in hospitals are often made of plasticized polyvinylchloride (PVC). These plasticizers may leach out into infused solutions during clinical practice, especially during risk-situations, e.g multiple infusions in Intensive Care Units and thus may enter into contact with the patients. The migrability of the plasticizers is dependent of several clinical parameters such as temperature, contact time, nature of the simulant, etc… However, no data is available about the influence of the flow rate at which drug solutions are administrated. In this study, we evaluated the impact of different flow rates on the release of the different plasticizers during an infusion procedure in order to assess if they could expose the patients to more toxic amounts of plasticizers. Migration assays with different PVC infusion sets and extension lines were performed with different flow rates that are used in clinical practice during 1h, 2h, 4h, 8h and 24h, using a lipophilic drug simulant. From a clinical point of view, the results showed that, regardless of the plasticizer, the faster the flow rate, the higher the infused volume and the higher the quantities of plasticizers released, both from infusion sets and extension lines, leading to higher patient exposure. However, physically, there was no significant difference of the migration kinetics linked to the flow rate for a same medical device, reflecting complex interactions between the PVC matrix and the simulant. The migration was especially dependent on the nature and the composition of the medical device.


Asunto(s)
Equipos y Suministros , Plastificantes/química , Cloruro de Polivinilo/química , Humanos , Unidades de Cuidados Intensivos