Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Clin. transl. oncol. (Print) ; 17(2): 113-120, feb. 2015. tab, ilus
Artículo en Inglés | IBECS | ID: ibc-132881

RESUMEN

Purpose. To evaluate an institute-specific CTV–PTV margin for head and neck (HN) patients according to a 3-mm action level protocol. Methods/patients. Twenty-three HN patients were prospectively analysed. Patients were immobilized with a thermoplastic mask. Inter- and intrafractional set-up errors (in the three dimensions) were assessed from portal images (PI) registration. Digitally reconstructed radiographs (DRRs) were compared with two orthogonal PI by matching bone anatomy landmarks. The isocenter was verified during the first five consecutive days of treatment: if the mean error detected was greater than 2 mm the isocenter position was corrected for the rest of the treatment. Isocenter was checked weekly thereafter. Set-up images were obtained before and after treatment administration on 10, 20 and 30 fractions to quantify the intrafractional displacement. For the set-up errors, systematic (Σ), random (σ), overall standard deviations, and the overall mean displacement (M), were determined. CTV to PTV margin was calculated considering both inter- and intrafractional errors. Results. A total of 396 portal images was analysed in 23 patients. Systematic interfractional (Σinter) set-up errors ranged between 0.77 and 1.42 mm in the three directions, whereas the random (σ inter) errors were around 1–1.31 mm. Systematic intrafractional (Σintra) errors ranged between 0.65 and 1.11 mm, whereas the random (σ intra) errors were around 1.13–1.16 mm. Conclusions. A verification protocol (3-mm action level) provided by EPIDs improves the set-up accuracy. Intrafractional error is not negligible and contributes to create a larger CTV–PTV margin. The appropriate CTV–PTV margin for our institute is between 3 and 4.5 mm considering both inter- and intrafractional errors (AU)


No disponible


Asunto(s)
Humanos , Masculino , Femenino , Neoplasias de Cabeza y Cuello/radioterapia , Errores Diagnósticos/prevención & control , Radiografía , Diagnóstico por Imagen/métodos , Diagnóstico por Imagen , Radioterapia/instrumentación , Radioterapia/métodos , Radioterapia Guiada por Imagen/instrumentación , Radioterapia Guiada por Imagen/métodos , Radioterapia Guiada por Imagen , Estudios Prospectivos , Tecnología Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Intensificación de Imagen Radiográfica/instrumentación , Radioterapia Guiada por Imagen/normas , Radioterapia Guiada por Imagen/tendencias
2.
Clin Transl Oncol ; 17(2): 113-20, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25037850

RESUMEN

PURPOSE: To evaluate an institute-specific CTV-PTV margin for head and neck (HN) patients according to a 3-mm action level protocol. METHODS/PATIENTS: Twenty-three HN patients were prospectively analysed. Patients were immobilized with a thermoplastic mask. Inter- and intrafractional set-up errors (in the three dimensions) were assessed from portal images (PI) registration. Digitally reconstructed radiographs (DRRs) were compared with two orthogonal PI by matching bone anatomy landmarks. The isocenter was verified during the first five consecutive days of treatment: if the mean error detected was greater than 2 mm the isocenter position was corrected for the rest of the treatment. Isocenter was checked weekly thereafter. Set-up images were obtained before and after treatment administration on 10, 20 and 30 fractions to quantify the intrafractional displacement. For the set-up errors, systematic (Σ), random (σ), overall standard deviations, and the overall mean displacement (M), were determined. CTV to PTV margin was calculated considering both inter- and intrafractional errors. RESULTS: A total of 396 portal images was analysed in 23 patients. Systematic interfractional (Σ(inter)) set-up errors ranged between 0.77 and 1.42 mm in the three directions, whereas the random (σ (inter)) errors were around 1-1.31 mm. Systematic intrafractional (Σ(intra)) errors ranged between 0.65 and 1.11 mm, whereas the random (σ (intra)) errors were around 1.13-1.16 mm. CONCLUSIONS: A verification protocol (3-mm action level) provided by EPIDs improves the set-up accuracy. Intrafractional error is not negligible and contributes to create a larger CTV-PTV margin. The appropriate CTV-PTV margin for our institute is between 3 and 4.5 mm considering both inter- and intrafractional errors.


Asunto(s)
Fraccionamiento de la Dosis de Radiación , Neoplasias de Cabeza y Cuello/radioterapia , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Radioterapia Conformacional/métodos , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...