1.
Cancer Radiother ; 23(4): 281-289, 2019 Jul.
Artículo en Francés | MEDLINE | ID: mdl-31151816

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) plays an increasing role in radiotherapy dose planning. Indeed, MRI offers superior soft tissue contrast compared to computerized tomography (CT) and therefore could provide a better delineation of target volumes and organs at risk than CT for radiotherapy. Furthermore, an MRI-only radiotherapy workflow would suppress registration errors inherent to the registration of MRI with CT. However, the estimation of the electronic density of tissues using MRI images is still a challenging issue. The purpose of this work was to design and evaluate a pseudo-CT generation method for prostate cancer treatments. MATERIALS AND METHODS: A pseudo-CT was generated for ten prostate cancer patients using an elastic deformation based method. For each patient, dose delivered to the patient was calculated using both the planning CT and the pseudo-CT. Dose differences between CT and pseudo-CT were investigated. RESULTS: Mean dose relative difference in the planning target volume is 0.9% on average and ranges from 0.1% to 1.7%. In organs at risks, this value is 1.8%, 0.8%, 0.8% and 1% on average in the rectum, the right and left femoral heads, and the bladder respectively. CONCLUSION: The dose calculated using the pseudo-CT is very close to the dose calculated using the CT for both organs at risk and PTV. These results confirm that pseudo-CT images generated using the proposed method could be used to calculate radiotherapy treatment doses on MRI images.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X
2.
Phys Med ; 42: 332-338, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28526235

RESUMEN

Using magnetic resonance imaging (MRI) as the sole imaging modality for patient modeling in radiation therapy (RT) is a challenging task due to the need to derive electron density information from MRI and construct a so-called pseudo-computed tomography (pCT) image. We have previously published a new method to derive pCT images from head T1-weighted (T1-w) MR images using a single-atlas propagation scheme followed by a post hoc correction of the mapped CT numbers using local intensity information. The purpose of this study was to investigate the performance of our method with head zero echo time (ZTE) MR images. To evaluate results, the mean absolute error in bins of 20 HU was calculated with respect to the true planning CT scan of the patient. We demonstrated that applying our method using ZTE MR images instead of T1-w improved the correctness of the pCT in case of bone resection surgery prior to RT (that is, an example of large anatomical difference between the atlas and the patient).


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos , Algoritmos , Atlas como Asunto , Encéfalo/diagnóstico por imagen , Encéfalo/efectos de la radiación , Encéfalo/cirugía , Neoplasias Encefálicas/cirugía , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X
3.
Phys Med ; 32(10): 1225-1237, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27659008

RESUMEN

PURPOSE: The main focus of the current paper is the clinical implementation of a Monte Carlo based platform for treatment plan validation for Tomotherapy and Cyberknife, without adding additional tasks to the dosimetry department. METHODS: The Monte Carlo platform consists of C++ classes for the actual functionality and a web based GUI that allows accessing the system using a web browser. Calculations are based on BEAMnrc/DOSXYZnrc and/or GATE and are performed automatically after exporting the dicom data from the treatment planning system. For Cyberknife treatments of moving targets, the log files saved during the treatment (position of robot, internal fiducials and external markers) can be used in combination with the 4D planning CT to reconstruct the actually delivered dose. The Monte Carlo platform is also used for calculation on MRI images, using pseudo-CT conversion. RESULTS: For Tomotherapy treatments we obtain an excellent agreement (within 2%) for almost all cases. However, we have been able to detect a problem regarding the CT Hounsfield units definition of the Toshiba Large Bore CT when using a large reconstruction diameter. For Cyberknife treatments we obtain an excellent agreement with the Monte Carlo algorithm of the treatment planning system. For some extreme cases, when treating small lung lesions in low density lung tissue, small differences are obtained due to the different cut-off energy of the secondary electrons. CONCLUSIONS: A Monte Carlo based treatment plan validation tool has successfully been implemented in clinical routine and is used to systematically validate all Cyberknife and Tomotherapy plans.


Asunto(s)
Radiocirugia/estadística & datos numéricos , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/estadística & datos numéricos , Radioterapia de Intensidad Modulada/normas , Algoritmos , Fenómenos Biofísicos , Simulación por Computador , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Imagen por Resonancia Magnética , Masculino , Método de Montecarlo , Control de Calidad , Dosificación Radioterapéutica , Programas Informáticos
4.
Cancer Radiother ; 19(5): 303-7, 2015 Aug.
Artículo en Francés | MEDLINE | ID: mdl-26206733

RESUMEN

PURPOSE: This work evaluated the interobserver variability in cone beam computed tomography (CBCT) registration for prostate cancers treated with intensity-modulated radiotherapy. MATERIAL AND METHODS: Twelve technologists realized 286 CBCT/CT registrations (bone registration followed by prostate to prostate registration). The registration results were compared to those obtained by two radiation oncologists (reference). Each technologist reported the shifts calculated by the software in all three axes. A statistical analysis allowed us to calculate the minimum threshold under which 95% of the observers found similar values. A variance analysis followed by the post hoc test were used to find differences in interobserver registration variability and determine whether any individual users performed registrations which differed significantly from those of the other users. RESULTS: The registration differences compared to the reference in the three directions in terms of 95th percentile are: 2.1mm left-right, 3.5mm target-gun, 7.3mm anterior-posterior. In the posterior direction, 4% of the observers have found differences superior to 8mm, margin used in routine without the use of a daily CBCT. The variance test revealed a P-value <0.05 only for target-gun and for all observers there was no significant difference compared to the reference. CONCLUSION: This study confirmed the interest of a 3D tissue registration for prostate treatments. The registration study showed a good interobserver reproducibility. This showed the importance of a daily CBCT/CT registration in prostate treatment with the possibility of a planning target volume margin reduction in the three directions. An evaluation of a partial delegation of registration to technologists should be done by the radiation oncologists.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/radioterapia , Fraccionamiento de la Dosis de Radiación , Humanos , Imagenología Tridimensional , Masculino , Variaciones Dependientes del Observador , Radioterapia de Intensidad Modulada/métodos